# Station Guide — Network Settings
|
|||
|
|
|
||
|
|
This section describes the Network Settings interface of the AIMsight Monitoring software. It
|
||
|
|
allows configuration of how the device communicates with external systems and local networks.
|
||
|
|
The interface is divided into two main sections:
|
||
|
|
• Ethernet (wired network)
|
||
|
|
• Cellular network (mobile connection)
|
||
|
|
The Ethernet section manages the physical connection through an Ethernet cable. Two
|
||
|
|
configuration modes are available:
|
||
|
|
• automatic (DHCP)
|
||
|
|
• manual (static IP)
|
||
|
|
Automatic configuration is recommended whenever possible.
|
||
|
|
• Automatic configuration (DHCP): by default, the camera is configured as a DHCP server
|
||
|
|
and automatically assigns an IP address to the connected computer. The computer must be
|
||
|
|
configured to obtain an IP address automatically, and no external network infrastructure is
|
||
|
|
required.
|
||
|
|
• Manual configuration: the IP address is configured manually.
|
||
|
|
Recommended manual configuration:
|
||
|
|
• IP address: 192.168.1.10
|
||
|
|
• Subnet mask: 255.255.255.0
|
||
|
|
CAUTION
|
||
|
|
The PC must be configured within the same network range as the camera (192.168.1.X) and
|
||
|
|
must use a unique IP address to prevent IP conflicts.
|
||
|
|
|
||
|
|
Source : AIMsight Station Guide, rév. 1.5
|