# One target is no longer being measured. What should I check?
|
||||
|
|
|
|||
|
|
First inspect the corresponding camera image and the target’s Error Value.
|
|||
|
|
Check:
|
|||
|
|
• whether the target is still visible;
|
|||
|
|
• whether the target is still inside its processing area;
|
|||
|
|
• whether the Error Value has increased above the configured Error Threshold;
|
|||
|
|
• whether the target is partially or completely obstructed;
|
|||
|
|
• whether the target is dirty, damaged, or covered by water, dust, snow, vegetation, or
|
|||
|
|
another object;
|
|||
|
|
• whether a reflective target or prism has changed orientation;
|
|||
|
|
• whether illumination conditions have changed significantly;
|
|||
|
|
• image focus and exposure;
|
|||
|
|
• whether the camera itself has moved significantly;
|
|||
|
|
• whether the physical target has undergone a displacement larger than the configured
|
|||
|
|
processing area.
|
|||
|
|
If several targets become invalid simultaneously, also check:
|
|||
|
|
• camera movement;
|
|||
|
|
• focus or contamination of the camera window;
|
|||
|
|
• illumination conditions;
|
|||
|
|
• communication with the camera;
|
|||
|
|
• the reference-network fit and sigma0.
|
|||
|
|
If the Error Value exceeds the threshold, the measurement is normally rejected rather than
|
|||
|
|
interpreted as a valid displacement.
|
|||
|
|
The current image, the target-recognition metrics, Camera Movement, and sigma0 are generally
|
|||
|
|
the fastest way to distinguish an optical or visibility problem, camera instability, referencenetwork deformation, and an actual displacement. When AIMsight Cloud is included, a
|
|||
|
|
measurement can be opened together with its corresponding archived image, making it easier to
|
|||
|
|
identify the cause of an abnormal value without first retrieving image files separately.
|
|||
|
|
|
|||
|
|
Source : AIMsight FAQ, rév. 1.5
|