# Station Guide — Error Value
|
|||
|
|
|
||
|
|
The “Error Value” measures how well the current image of the tracked target matches its
|
||
|
|
reference image after compensating for the measured displacement.
|
||
|
|
Values close to 0 indicate good agreement with the reference. Increasing values indicate that the
|
||
|
|
current target image differs increasingly from the image used as its reference.
|
||
|
|
Practical use: This is the main general-purpose registration-quality indicator. An increase can be
|
||
|
|
caused by:
|
||
|
|
• partial or complete obstruction of the target;
|
||
|
|
• poor target visibility;
|
||
|
|
• blur or atmospheric disturbance;
|
||
|
|
• changes in illumination or target appearance;
|
||
|
|
• loss of the target; or
|
||
|
|
• incorrect image registration.
|
||
|
|
Because several different phenomena can increase the Error Value, the other image-quality
|
||
|
|
statistics are useful for identifying the likely cause.
|
||
|
|
The obstruction filters use this indicator to reject measurements exceeding the configured “Error
|
||
|
|
Threshold”.
|
||
|
|
|
||
|
|
Source : AIMsight Station Guide, rév. 1.5
|