# Station Guide — Error Value
The “Error Value” measures how well the current image of the tracked target matches its
reference image after compensating for the measured displacement.
Values close to 0 indicate good agreement with the reference. Increasing values indicate that the
current target image differs increasingly from the image used as its reference.
Practical use: This is the main general-purpose registration-quality indicator. An increase can be
caused by:
• partial or complete obstruction of the target;
• poor target visibility;
• blur or atmospheric disturbance;
• changes in illumination or target appearance;
• loss of the target; or
• incorrect image registration.
Because several different phenomena can increase the Error Value, the other image-quality
statistics are useful for identifying the likely cause.
The obstruction filters use this indicator to reject measurements exceeding the configured “Error
Threshold”.
Source : AIMsight Station Guide, rév. 1.5