# Station Guide — Error Value
|
||||
|
||||
The “Error Value” measures how well the current image of the tracked target matches its
|
||||
reference image after compensating for the measured displacement.
|
||||
Values close to 0 indicate good agreement with the reference. Increasing values indicate that the
|
||||
current target image differs increasingly from the image used as its reference.
|
||||
Practical use: This is the main general-purpose registration-quality indicator. An increase can be
|
||||
caused by:
|
||||
• partial or complete obstruction of the target;
|
||||
• poor target visibility;
|
||||
• blur or atmospheric disturbance;
|
||||
• changes in illumination or target appearance;
|
||||
• loss of the target; or
|
||||
• incorrect image registration.
|
||||
Because several different phenomena can increase the Error Value, the other image-quality
|
||||
statistics are useful for identifying the likely cause.
|
||||
The obstruction filters use this indicator to reject measurements exceeding the configured “Error
|
||||
Threshold”.
|
||||
|
||||
Source : AIMsight Station Guide, rév. 1.5
|
||||