Station Guide — Charging

CAUTION The system tolerates a maximum input voltage of 26 V on both the power-supply connector and the optional passive PoE input. Never connect a standard IEEE PoE source (802.3af, 802.3at or 802.3bt), as the standard PoE voltages of 48 V and above may damage the charge controller. CAUTION The centre pin of the barrel connector is positive. If you are not using an AIMsight-supplied power solution, always verify the connector polarity before connection, especially when using third-party adapters such solar panels with MC4 connectors or adapters. For mains-powered operation, connect the supplied power supply to an electrical outlet, then connect it to the camera. This operating mode is recommended for charging the battery between mobile deployments or when power is available at the monitoring site. In this configuration, the battery remains connected and acts as an internal backup power source (UPS) in case of a temporary power interruption. For autonomous field operation, the camera can be connected to a solar panel. We recommend using a standard 12 V solar panel; in most cases, a generic 100 W panel provides sufficient charging capacity. Install the panel in a location with good sun exposure and orient it appropriately for the site conditions. The battery charges automatically whenever a suitable external power source is connected. Charging performance depends on the available input power, battery state of charge, and ambient conditions. For reliable operation, ensure that the external power source remains within the specified voltage range and is capable of supplying adequate current. NOTE After a deep discharge (battery voltage below 12 V), the camera may not restart immediately. To prevent repeated restart attempts caused by an insufficient charge level, the system remains off until the battery voltage reaches approximately 12.6 V before powering up again. While charging, verify that the charge-status LED is red. Once the battery has recovered to the required voltage, the system will start automatically, provided that it is switched on.

Source : AIMsight Station Guide, rév. 1.5