Découpage : page précédée de U+2060, titres coupés sur plusieurs lignes, saut de page dans la table des matières (trois tests). Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
4.1 KiB
Station Guide — Working with Conventional Image Features
When reflectors are unavailable or difficult to install, sufficiently contrasted and stable visual features may also be tracked. If the installed software provides the Work on IRON images option, enable it to work with conventional images rather than the contrast-enhanced reflector representation. Verify that the selected texture remains visible and stable under all expected measurement conditions. Once a zone has been drawn, a new row appears in the “Marker Configuration” table. Define the marker parameters in the “Marker Configuration” table: • Name: name of the position marker, that is, the name of the measurement channel • Type: assigns the marker to a group or type. Reference targets are considered fixed points, while markers in “Target Group(s)” are tracked. Proper selection of reference targets is essential because they are used to compensate for camera motion. • Global reference: a point considered fixed in the monitored scene. Global-reference points are used to estimate and compensate for movement of the monitoring station itself. • Local reference: identifies a measurement point as belonging to the local-reference group. This designation is used for classification and display purposes only. Unlike a Global reference, a local reference is not treated as a fixed point and is not used to compensate for movements of the monitoring station. No additional processing is applied; local references are handled in the same way as other measurement-point groups. • Error Threshold (optional): threshold above which a measurement is considered invalid. This is used to detect obstructions, for example when a marker is hidden by a vehicle or vegetation. By default, the error threshold is 0.7. • Pattern Size: adjusts the size of the image-processing area around the marker • Resolution (optional): processing resolution, expressed as a fraction of a pixel. The default value is 100, corresponding to one hundredth of a pixel. Lower values reduce processing time. • Distance: straight-line distance in millimeters between the front of the camera and the marker. This is used to calculate the correct pixel-to-distance conversion factor. An error in the entered distance produces a proportional scale error. For example, a coarse distance error of 1%—such as entering 99 m or 101 m instead of 100 m—produces an error of approximately 0.1 mm on a measured displacement of 10 mm. • Reference date: records the time at which the reference pattern defining the zero position was set To adjust the position of the marker area, first select it by clicking its border. You can then drag its corners to reshape it or drag inside the area to move it. It is generally best to keep the marker centered within the target region. The “Recapture” button allows you to take a new image and verify that the marker zones are correctly defined. Once the settings have been established, save the pattern configuration by clicking “Save Configuration”. The reference patterns are then extracted from the image currently displayed. This image becomes the zero for each channel, and subsequent displacements are calculated relative to the positions saved at that moment. To redefine the zero, display or recapture an appropriate new image, verify all zones and parameters, and save the configuration again. The “Store Locally” toggle must be enabled if the system is to keep measurements in onboard memory. If the system has internet access through either Ethernet or the onboard 4G module, it can also be configured to forward measurements to the AIMsight database by enabling “Send to Server”. The “Send to Monitoring” option must be enabled to transmit measurements in real time to the monitoring platform. When activated, the system continuously sends data to the remote supervision interface, allowing live tracking and analysis. The “Send to FTP Server” option must be enabled to upload the measurements automatically to an external FTP server. This allows the data to be archived and accessed later for analysis or backup purposes. Target Configuration
Source : AIMsight Station Guide, rév. 1.5