Station Guide — Error Value

The “Error Value” measures how well the current image of the tracked target matches its reference image after compensating for the measured displacement. Values close to 0 indicate good agreement with the reference. Increasing values indicate that the current target image differs increasingly from the image used as its reference. Practical use: This is the main general-purpose registration-quality indicator. An increase can be caused by: • partial or complete obstruction of the target; • poor target visibility; • blur or atmospheric disturbance; • changes in illumination or target appearance; • loss of the target; or • incorrect image registration. Because several different phenomena can increase the Error Value, the other image-quality statistics are useful for identifying the likely cause. The obstruction filters use this indicator to reject measurements exceeding the configured “Error Threshold”.

Source : AIMsight Station Guide, rév. 1.5