Découpage : page précédée de U+2060, titres coupés sur plusieurs lignes, saut de page dans la table des matières (trois tests). Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
1.2 KiB
Station Guide — Pattern Creation Page
This page allows you to configure image acquisition parameters and image processing, including the definition of the markers tracked by the camera. The Preset bar at the top of the page allows several target configurations, each with its own acquisition settings and processing zones, to be stored in addition to the main or default configuration. Defining a target establishes the reference pattern that the system searches for in each subsequent image to calculate target motion. In the local web interface, the reference pattern is extracted from the image currently displayed when Save Configuration is clicked. That image defines the zero position from which all subsequent relative or differential displacements are calculated. The corresponding date and time are recorded as the Reference date in the measurement-channel definition. Before saving, verify that the displayed image is representative, that all targets are clearly visible, and that no temporary object obscures a tracking zone. Saving the configuration again extracts new reference patterns from the currently displayed image and therefore redefines the displacement zero.
Source : AIMsight Station Guide, rév. 1.5