Which diagnostic signals are available in Data Exploration?

In addition to the principal displacement values, Data Exploration provides signals describing target visibility, image quality, registration reliability, and camera movement. These indicators are calculated by the station and are intended to be interpreted together with the corresponding images and as trends over time. The principal signals are: • Relative Horizontal / Vertical: the main target-displacement results in millimetres, after calibration and, when enabled, camera-motion correction. • Raw Horizontal / Vertical: the target position in the image in pixels, before conversion to millimetres and before camera-motion correction. • Error Value: the difference between the current target image and its reference after registration. It is the main general-purpose recognition-quality indicator and is used by the obstruction filters. • Sharpness: indicates how concentrated the target image is. A decreasing trend can suggest defocus, vibration, atmospheric disturbance, or another loss of image quality. • FWHM: estimates the apparent width of the target image in pixels. An increasing trend can indicate image spreading caused by defocus, turbulence, motion blur, or vibration. • Dominance: indicates whether another bright feature is becoming comparable with the tracked reflector. A value approaching 1 indicates an increasing risk of competition between image features. • Peak Intensity: the maximum pixel value in the target image. It helps identify major changes in illumination or target response, as well as possible saturation. • Flux: the total target signal after estimating the image background. It is useful for detecting gradual changes in illumination, reflector condition, alignment, or obstruction. • SNR: compares the target signal with variations in the local background. A decreasing value means that the target is becoming less distinct from its surroundings. • Camera Movement: the global movement estimated from the reference targets and used to compensate for movement of the camera or its support. No single metric should normally be treated as a universal pass/fail criterion. The combination of several trends is generally more informative. The Available Signals and Diagnostic Metrics section of the station manual provides the complete definitions and interpretation guidance.

Source : AIMsight FAQ, rév. 1.5