Add the temperature domain on the GPU manufacturer limit

DAILY_GPU_TEMPERATURE_LIMIT: red when an hourly GPU mean reached 97.5 °C
(T.gpu, Jetson Nano Thermal Design Guide) in the last 24 hours, green
otherwise, gray without measurement. Working sets WEISSHORN and NORDEND;
all measured days are green. D-040 replaces D-036; the exploration note
moves to docs/temperature/domaine/point-de-depart.md.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
maximeandClaude Opus 5.5 committed 2026-10-13 16:07:36 +02:00
1 parent f0990c16e6
commit 276c34ea38
12 files changed
+256 -19

No files matched your search

+1 -1
View File
@@ -18,7 +18,7 @@ La source est le collecteur embarqué `docs/aimsight/collecteur_system_info.py`
| `BusCurrent` | mA | courant consommé par la station |
| `Power` | mW | puissance consommée |
| `ShuntVoltage` | mV | tension aux bornes du shunt (= courant × 0,1 Ω) |
| `sensor_*_deg_c` | °C | températures de la carte de calcul (A0, CPU, GPU, PLL, thermal selon la version du collecteur ; `temperatures-de-la-station.md`) |
| `sensor_*_deg_c` | °C | températures de la carte de calcul (A0, CPU, GPU, PLL, thermal selon la version du collecteur ; `docs/temperature/domaine/point-de-depart.md`) |
- **`Power`, `BusCurrent` et `ShuntVoltage` sont une seule et même mesure.** On le vérifie avec P/(V·I) ≈ 0,99 et Shunt/0,1 Ω ≈ I.
- Ces trois métriques mesurent la **consommation** de la station. Le courant ne devient jamais négatif. Il baisse à midi quand la tension monte, comme une charge à puissance constante.