Add DAILY_MAINS_POWER: on mains, a mains loss turns the day red at once

A station is on mains when its BusVoltage mean over the 3 days before
the day is >= 14.0 V (solar never exceeds 13.50 V on VERMONT; mains
stays >= 14.08 V). On mains, the mains loss decides the day color
instead of the state x trend matrix: red as soon as an hour falls under
13.4 V (top of the OCV plateau; mains-on hours stay >= 13.65 V, mains-off
hours are 13.1-13.3 V). On MISSISSIPPI the day turns red 1-2 h after the
loss instead of 29-40 h with the matrix; WEISSHORN and NORDEND (mains)
raise no false alert, VERMONT (solar) is unchanged (D-043).

The matrix drawio gets the mains case, the site figure a third panel,
and the support notification and the client Energy block header show
"On mains" / "Not on mains" / "Mains unknown".

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
maximeandClaude Opus 5.5 committed 2026-10-13 17:22:16 +02:00
1 parent 28ed86baba
commit 9177982de1
18 files changed
+359 -43

No files matched your search

+1
View File
@@ -52,6 +52,7 @@
.status { padding: 2px 12px; border-radius: 999px; font-size: 13px; font-weight: bold; color: #fff; }
.status.ORANGE { background: var(--orange); color: #1a1a1a; } .status.RED { background: var(--red); }
.meta { color: var(--muted); font-size: 13px; }
.power { padding: 1px 10px; border: 1px solid var(--line); border-radius: 999px; font-size: 13px; } /* Energy : secteur ou non (D-043) */
/* Vignettes des stations, comme sur le site : nom, dernière tension, courbe de la fenêtre. */
.grid { display: grid; grid-template-columns: repeat(auto-fill, minmax(200px, 1fr)); gap: 16px 0; margin-bottom: 20px; }