Add DAILY_MAINS_POWER: on mains, a mains loss turns the day red at once

A station is on mains when its BusVoltage mean over the 3 days before
the day is >= 14.0 V (solar never exceeds 13.50 V on VERMONT; mains
stays >= 14.08 V). On mains, the mains loss decides the day color
instead of the state x trend matrix: red as soon as an hour falls under
13.4 V (top of the OCV plateau; mains-on hours stay >= 13.65 V, mains-off
hours are 13.1-13.3 V). On MISSISSIPPI the day turns red 1-2 h after the
loss instead of 29-40 h with the matrix; WEISSHORN and NORDEND (mains)
raise no false alert, VERMONT (solar) is unchanged (D-043).

The matrix drawio gets the mains case, the site figure a third panel,
and the support notification and the client Energy block header show
"On mains" / "Not on mains" / "Mains unknown".

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
maximeandClaude Opus 5.5 committed 2026-10-13 17:22:16 +02:00
1 parent 28ed86baba
commit 9177982de1
18 files changed
+359 -43

No files matched your search

+2 -1
View File
@@ -4,6 +4,7 @@
Chaque bloc : couleur du dernier jour de la fenêtre et sa phrase (src/<domaine>/day_color.py), deux lignes en mots simples
(Energy : échelle de batterie et tendance ; Storage : échelle de l'espace libre et date de saturation ; Cellular : envois
du jour et échelle du signal ; Temperature : maximum des 24 h et limite), puis historique complet (src/<domaine>/final.py, D-021) et guide (partie 1), repliés.
Energy affiche aussi, dans son en-tête, si la station est sur secteur ou non (DAILY_MAINS_POWER, D-043).
Données réelles : une page par station de data/. Écrit out/maquette_user_<STATION>.html et les ouvre dans le navigateur.
Usage : python3 maquettes/user/summary.py [AAAA-MM-JJ début] [AAAA-MM-JJ fin] (défaut : 2026-09-18 à 2026-09-28)
"""
@@ -38,7 +39,7 @@ DOMAINS = {"energy": (energy, energy_figure, "docs/energy/guide/diagnostic-energ
IDENTIFIERS = ("SIM_CCID", "ip") # préfixes des identifiants de la station : jamais affichés (CLAUDE.md, data/)
RULE = {"full_charge_v": bs.FULL_CHARGE_V, "min_rise_v": bs.MIN_RISE_V, "storage_floors": sts.FREE_PERCENT_FLOORS,
"expected_sends": ls.SAMPLES_PER_HOUR * ls.HOURS_PER_DAY, "signal_classes": sgs.CLASSES,
"gpu_limit_deg_c": gl.GPU_LIMIT_DEG_C}
"gpu_limit_deg_c": gl.GPU_LIMIT_DEG_C, "power_label": energy.POWER_LABEL}
def guide(path):
+4
View File
@@ -55,6 +55,7 @@
.status.GREEN { background: var(--green); } .status.ORANGE { background: var(--orange); color: #1a1a1a; }
.status.RED { background: var(--red); } .status.UNKNOWN { background: var(--unknown); }
.meta { color: var(--muted); font-size: 13px; }
.power { padding: 1px 10px; border: 1px solid var(--line); border-radius: 999px; font-size: 13px; color: var(--text); }
.diag-item > summary .chev { margin-left: auto; width: 13px; height: 13px; transition: transform .15s; }
.diag-item[open] > summary .chev { transform: rotate(180deg); }
.diag-body { border-top: 1px solid var(--line); padding: 14px; }
@@ -266,6 +267,9 @@ for (const [key, dom] of Object.entries(DATA.domains)) {
el.id = key;
el.querySelector(".name").textContent = name;
el.querySelector(".status").outerHTML = chip(c);
// Energy : sur secteur ou non, visible sans ouvrir le bloc (DAILY_MAINS_POWER, D-043) ; null = statut inconnu.
if (key === "energy") el.querySelector(".status").insertAdjacentHTML("afterend",
`<span class="power">${R.power_label[cur.power ?? null]}</span>`);
el.querySelector(".meta").textContent = `${DATA.label} · ${ACTION[c] || "Check data"}`;
el.querySelector(".headline").textContent = dom.headline[c] || `Not enough data to assess the station's ${what}.`;