Spec analysis 03 DAILY_BATTERY_STATE, battery voltage report
- docs/analyses/analyse_03.md: design of the daily battery state analysis (phase C, state only): FULL_CHARGE / BELOW_PLATEAU / NO_CHARGE / PARTIAL_CHARGE per UTC day, hardware thresholds (14.0 V end of charge, 12.8 V LiFePO4 knee), status "en conception". - D-018: next analyses give a day-by-day state with hardware thresholds, usable from installation day; phase C then phase B. - docs/domaine: voltage report per battery state (charging, full, discharging) with sources; Power dispersion on VERMONT. - CLAUDE.md: analyses table, state and next step, domain map. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
7b1da6d7cf
commit
e77d3e4b82
5 files changed
+211
-3
No files matched your search
@@ -41,5 +41,6 @@ Ces valeurs ne sont pas exportées dans les CSV actuels :
|
||||
|
||||
- La consommation est d'environ 5,0 W constants d'avril à octobre (~120 Wh/j). Le déficit de fin septembre vient donc d'un apport en baisse, pas d'une consommation en hausse.
|
||||
- Exceptions :
|
||||
- ~3,3 W du 14/09 0 h au 15/09 13 h (essai du mode veille, probablement) ;
|
||||
- ~3,3 W du 13/09 23 h au 15/09 13 h (essai du mode veille, probablement) ;
|
||||
- 2,2 à 3,2 W le 09/10 à partir de 13 h (cohérent avec `mode SLP`).
|
||||
- Dispersion, hors exceptions : heures entre 4,7 et 5,7 W (5e et 95e centiles), pics isolés jusqu'à 7,3 W ; moyennes journalières de 4,9 à 5,5 W ; moyennes mensuelles de 5,03 W (avril) à 5,17 W (juillet). Le profil horaire varie de 4,99 W (04 h UTC) à 5,18 W (14 h UTC). Cause de la légère hausse estivale et diurne non établie.
|
||||
Reference in new issue