Spec analysis 03 DAILY_BATTERY_STATE, battery voltage report

- docs/analyses/analyse_03.md: design of the daily battery state
  analysis (phase C, state only): FULL_CHARGE / BELOW_PLATEAU /
  NO_CHARGE / PARTIAL_CHARGE per UTC day, hardware thresholds
  (14.0 V end of charge, 12.8 V LiFePO4 knee), status "en conception".
- D-018: next analyses give a day-by-day state with hardware
  thresholds, usable from installation day; phase C then phase B.
- docs/domaine: voltage report per battery state (charging, full,
  discharging) with sources; Power dispersion on VERMONT.
- CLAUDE.md: analyses table, state and next step, domain map.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
maximeandClaude Opus 5.5 committed 2026-10-12 10:43:36 +02:00
1 parent 7b1da6d7cf
commit e77d3e4b82
5 files changed
+211 -3

No files matched your search

+2 -1
View File
@@ -41,5 +41,6 @@ Ces valeurs ne sont pas exportées dans les CSV actuels :
- La consommation est d'environ 5,0 W constants d'avril à octobre (~120 Wh/j). Le déficit de fin septembre vient donc d'un apport en baisse, pas d'une consommation en hausse.
- Exceptions :
- ~3,3 W du 14/09 0 h au 15/09 13 h (essai du mode veille, probablement) ;
- ~3,3 W du 13/09 23 h au 15/09 13 h (essai du mode veille, probablement) ;
- 2,2 à 3,2 W le 09/10 à partir de 13 h (cohérent avec `mode SLP`).
- Dispersion, hors exceptions : heures entre 4,7 et 5,7 W (5e et 95e centiles), pics isolés jusqu'à 7,3 W ; moyennes journalières de 4,9 à 5,5 W ; moyennes mensuelles de 5,03 W (avril) à 5,17 W (juillet). Le profil horaire varie de 4,99 W (04 h UTC) à 5,18 W (14 h UTC). Cause de la légère hausse estivale et diurne non établie.