One analyst checks neighbouring stations together (.claude/skills/review-auto-labels/coherence.md). The month's drift, shared by the three cameras (same step on 08/10, same recoil 13-16/10), is Displacement everywhere, cause not established (the building or its temperature); the 09/10 reference losses and the 15-16/10 gap are tied across stations, a common cause to look for in the building; the 26/10 cold morning added on BREITHORN and NEBRASKA; MICHIGAN 27/10 as Displacement. Proposed per-station files versioned.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
MICHIGAN: 13 labels, 3 kept, 10 corrected (the 05/10 reconfiguration as Target issue, one drift label from 03/10 counting the compensated thermal movement, the housing temperature instead of the factory's). NEBRASKA: 8 labels, 2 kept, 6 corrected, 2 missed added (COLJ19 alone on 17/10, the cold morning of 19/10); cold mornings as Thermal displacement instead of Visibility. All carry "revue": "2026-11-04"; lessons for the labeler not applied yet.