maximeandClaude Opus 5.5 d5bae7a696 Add the loop's end-of-session page and a detector benchmark on the case base
- End-of-session page for /boucle: the session's curves, the analyst's
  labels against the detectors' events per category, a plain score table
  and the benchmark (comparaison.py, D-066)
- Detectors moved to vues-deplacements/detectors/ (D-067)
- Detectors must detect everything; what the client sees is a separate
  layer (D-068)
- Benchmark: each case keeps its labels from creation (etiquettes.json),
  benchmark.py scores the detectors on every case, history in
  vues-deplacements/benchmark/historique.csv; run by /boucle at each lot,
  after each change and at the end, read by the upgrader and validator;
  labels for C-001..C-005 from one analyst pass corrected by their files,
  C-006..C-008 from lot 01 (D-069)
- Fixes from the releveur's notes: /boucle arguments and other sessions,
  branch name in the spec, detector name in categories.py output, learned
  case header, anonymiser.py (camera/, no empty CSVs, --etiquettes),
  ensemble.py (clock-aligned steps, title), plages.py (same-sign merge),
  labeling request written into /nouveau-cas
- Also carries the other session's uncommitted D-065 edits in the same
  files; data/, .gitignore, pomper.py and stations.py are left out

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-26 16:48:13 +01:00

62 lines
7.3 KiB
JSON
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{"station": "C-001", "debut": "2026-10-08T22:00Z", "fin": "2026-10-14T10:00Z", "moments": [
{"debut": "2026-10-08T22:00Z", "fin": "2026-10-14T09:45Z", "capteurs": ["C12"],
"categorie": "aucune", "evenement": null, "preuve": "deduite",
"description": "C12 rejetée à toutes les mesures : error_value 0,41, au-dessus de son seuil de 0,3, avec le même cycle jour/nuit que les autres cibles ; pas de courbe corrigée.", "apres_detecteurs": false},
{"debut": "2026-10-08T22:00Z", "fin": "2026-10-09T07:45Z", "capteurs": ["C1", "C2", "C3", "C4", "C5", "C6", "C7", "C8", "C9", "C10", "C11"],
"categorie": "contraction_thermique", "evenement": "Daily thermal cycle", "preuve": "deduite",
"description": "Fin du retour de nuit de la vague journalière : corr_y remonte lentement jusqu'au matin (C7 +0,37, C1 +0,51).", "apres_detecteurs": false},
{"debut": "2026-10-09T01:00Z", "fin": "2026-10-09T01:00Z", "capteurs": ["R1", "R2", "R3", "C1", "C2", "C4", "C8", "C11"],
"categorie": "saut_bref", "evenement": null, "preuve": "deduite",
"description": "Saut de la compensation d'une seule mesure : corr_x des références (8 à 11 bruits) et de plusieurs cibles (C11 −12 bruits), retour à 01:15.", "apres_detecteurs": false},
{"debut": "2026-10-09T08:00Z", "fin": "2026-10-09T15:30Z", "capteurs": ["C1", "C2", "C3", "C4", "C5", "C6", "C7", "C8", "C9", "C10", "C11"],
"categorie": "dilatation_thermique", "evenement": "Daily thermal cycle", "preuve": "deduite",
"description": "Phase chaude : corr_y descend (C7 −0,60, C11 −0,43), bosse de corr_x (C3 +0,55, C7 +0,49) ; positions brutes en mode commun le jour, error_value ordinaire.", "apres_detecteurs": false},
{"debut": "2026-10-09T12:00Z", "fin": "2026-10-09T12:00Z", "capteurs": [],
"categorie": "trou", "evenement": "No data", "preuve": "deduite",
"description": "Une mesure absente pour tous les capteurs.", "apres_detecteurs": false},
{"debut": "2026-10-09T15:45Z", "fin": "2026-10-10T08:00Z", "capteurs": ["C1", "C2", "C3", "C4", "C5", "C6", "C7", "C8", "C9", "C10", "C11"],
"categorie": "contraction_thermique", "evenement": "Daily thermal cycle", "preuve": "deduite",
"description": "Retour de la vague : corr_y remonte lentement toute la nuit, corr_x revient de sa bosse.", "apres_detecteurs": false},
{"debut": "2026-10-10T08:15Z", "fin": "2026-10-10T16:45Z", "capteurs": ["C1", "C2", "C3", "C4", "C5", "C6", "C7", "C8", "C9", "C10", "C11"],
"categorie": "dilatation_thermique", "evenement": "Daily thermal cycle", "preuve": "deduite",
"description": "Phase chaude plus faible en corr_x ; corr_y C7 −0,46, C1 −0,59 ; à 12:30-12:45 error_value des cibles en hausse deux mesures et pas de corr_y de C1, C3.", "apres_detecteurs": false},
{"debut": "2026-10-10T10:45Z", "fin": "2026-10-10T10:45Z", "capteurs": [],
"categorie": "trou", "evenement": "No data", "preuve": "deduite",
"description": "Une mesure absente pour tous les capteurs.", "apres_detecteurs": false},
{"debut": "2026-10-10T17:00Z", "fin": "2026-10-11T07:45Z", "capteurs": ["C1", "C2", "C3", "C4", "C5", "C6", "C7", "C8", "C9", "C10", "C11"],
"categorie": "contraction_thermique", "evenement": "Daily thermal cycle", "preuve": "deduite",
"description": "Retour de nuit de la vague ; à 18:00 une mesure où l'error_value de nombreuses cibles monte un peu, retour à 18:15.", "apres_detecteurs": false},
{"debut": "2026-10-11T08:00Z", "fin": "2026-10-11T17:30Z", "capteurs": ["C1", "C2", "C3", "C4", "C5", "C6", "C7", "C8", "C9", "C10", "C11"],
"categorie": "dilatation_thermique", "evenement": "Daily thermal cycle", "preuve": "deduite",
"description": "Phase chaude : corr_y C7 −0,43 ; bosse de corr_x moyenne (C3 +0,29, C7 +0,24).", "apres_detecteurs": false},
{"debut": "2026-10-11T17:45Z", "fin": "2026-10-12T07:15Z", "capteurs": ["C1", "C2", "C3", "C4", "C5", "C6", "C7", "C8", "C9", "C10", "C11"],
"categorie": "contraction_thermique", "evenement": "Daily thermal cycle", "preuve": "deduite",
"description": "Retour de nuit ; corr_y au matin le plus haut du lot (C7 +0,70).", "apres_detecteurs": false},
{"debut": "2026-10-12T07:30Z", "fin": "2026-10-12T17:15Z", "capteurs": ["C1", "C2", "C3", "C4", "C5", "C6", "C7", "C8", "C9", "C10", "C11"],
"categorie": "dilatation_thermique", "evenement": "Daily thermal cycle", "preuve": "deduite",
"description": "Phase chaude la plus forte : corr_x C7 +0,73, C1 +0,54, C3 +0,71 vers 14:30-15:45 ; corr_y C7 −0,64, C11 −0,46.", "apres_detecteurs": false},
{"debut": "2026-10-12T16:00Z", "fin": "2026-10-12T16:00Z", "capteurs": ["R1", "R2", "R3", "C3", "C6", "C7"],
"categorie": "saut_bref", "evenement": null, "preuve": "deduite",
"description": "Saut de la compensation d'une mesure (corr_x R1 −8 bruits, C3 −0,13), retour à 16:15 ; error_value de R3 ×2,7 à 16:00, de R1 en pic à 15:30 et 16:15.", "apres_detecteurs": false},
{"debut": "2026-10-12T17:30Z", "fin": "2026-10-13T07:00Z", "capteurs": ["C1", "C2", "C3", "C4", "C5", "C6", "C7", "C8", "C9", "C10", "C11"],
"categorie": "contraction_thermique", "evenement": "Daily thermal cycle", "preuve": "deduite",
"description": "Retour de nuit de la vague (C7 +0,58 au matin).", "apres_detecteurs": false},
{"debut": "2026-10-13T00:00Z", "fin": "2026-10-13T04:00Z", "capteurs": ["R2", "R3"],
"categorie": "visibilite_reduite", "evenement": "Rain or fog", "preuve": "deduite",
"description": "Deux références dehors moins bien vues : R3 jusqu'à 0,55 (+245 bruits), R2 jusqu'à 0,42, sans rejet ; sigma0 ×1,3, corr des références et de C3 décalés ; retour sans palier.", "apres_detecteurs": false},
{"debut": "2026-10-13T07:15Z", "fin": "2026-10-13T16:30Z", "capteurs": ["C1", "C2", "C3", "C4", "C5", "C6", "C7", "C8", "C9", "C10", "C11"],
"categorie": "dilatation_thermique", "evenement": "Daily thermal cycle", "preuve": "deduite",
"description": "Phase chaude : corr_y C7 −0,44 ; corr_x faible malgré la médiane brute x la plus haute.", "apres_detecteurs": false},
{"debut": "2026-10-13T16:45Z", "fin": "2026-10-14T07:30Z", "capteurs": ["C1", "C2", "C3", "C4", "C5", "C6", "C7", "C8", "C9", "C10", "C11"],
"categorie": "contraction_thermique", "evenement": "Daily thermal cycle", "preuve": "deduite",
"description": "Retour de nuit de la vague, mêlé à l'épisode de R2, R3.", "apres_detecteurs": false},
{"debut": "2026-10-13T23:45Z", "fin": "2026-10-14T05:15Z", "capteurs": ["R2", "R3"],
"categorie": "visibilite_reduite", "evenement": "Rain or fog", "preuve": "deduite",
"description": "R3 jusqu'à 0,67, R2 jusqu'à 0,69 (au ras du seuil 0,7), R1 intacte ; sigma0 ×1,5 ; paliers de corr_x des cibles à l'entrée et à la sortie de R3 (C3 −0,35 à 03:45) ; vignettes : taches de R2, R3 réduites à un point, témoins inchangés ; brume ou buée déduite, pas vue (fiche).", "apres_detecteurs": false},
{"debut": "2026-10-14T07:45Z", "fin": "2026-10-14T09:45Z", "capteurs": ["C1", "C2", "C3", "C4", "C5", "C6", "C7", "C8", "C9", "C10", "C11"],
"categorie": "dilatation_thermique", "evenement": "Daily thermal cycle", "preuve": "deduite",
"description": "Début de la phase chaude, jusqu'à la fin du lot.", "apres_detecteurs": false},
{"debut": "2026-10-14T09:30Z", "fin": "2026-10-14T09:30Z", "capteurs": [],
"categorie": "trou", "evenement": "No data", "preuve": "deduite",
"description": "Une mesure absente pour tous les capteurs.", "apres_detecteurs": false}]}