The night end and rise were anchored on the first daily maximum, which can be the 00:00 tail of the previous evening: 2026-05-05 was read NO_CHARGE despite a +0.079 V rise, 2026-09-30 showed a wrong night end, and 2026-09-26 stayed unknown from 04:00 to 11:00 when evaluated mid-day. The rise now starts from an earlier minimum and the knee is tested on the daily minimum (min_v). VERMONT: 139 / 31 / 14 / 0. Docs: sheet 02 page order, battery_state.py in the CLAUDE.md map, phase C exception to "anomaly = None means UNKNOWN". Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
78 lines
3.4 KiB
Python
78 lines
3.4 KiB
Python
"""Analyse 03 DAILY_BATTERY_STATE : état de la batterie jour par jour (phase C : état seul, sans verdict).
|
|
|
|
Documentation : docs/analyses/analyse_03.md
|
|
Bibliothèque standard uniquement (cible : système embarqué de la station).
|
|
"""
|
|
import math
|
|
from collections import defaultdict
|
|
|
|
from energy_check import HOUR
|
|
|
|
# Constantes (fiche analyse_03, « Constantes et sources »).
|
|
FULL_CHARGE_V = 14.0 # VERMONT : maxima journaliers < 13,55 V (35 j) ou 14,02-14,33 V (135 j) ; absorption ~14,2 V
|
|
PLATEAU_FLOOR_V = 12.8 # coude LiFePO4 : table OCV du collecteur (12,8 V = 30 %) ; pente nocturne doublée sous 12,8 V
|
|
MIN_RISE_V = 0.05 # > variations horaires sur le plateau (<= 15 mV/h), < plus faible vraie montée (+0,18 V, VERMONT 04-11)
|
|
MIN_COVERAGE = 0.8 # repris de l'analyse 01 : 20 h mesurées sur 24
|
|
|
|
RULE = {
|
|
"id": "DAILY_BATTERY_STATE",
|
|
"phase": "C : état seul, sans verdict (anomaly = None)",
|
|
"full_charge_v": FULL_CHARGE_V,
|
|
"plateau_floor_v": PLATEAU_FLOOR_V,
|
|
"min_rise_v": MIN_RISE_V,
|
|
"min_coverage": MIN_COVERAGE,
|
|
"doc": "docs/analyses/analyse_03.md",
|
|
}
|
|
|
|
|
|
def day_facts(day):
|
|
"""{heure UTC: tension mesurée} d'un jour -> faits et état (fiche analyse_03, « Principe »)."""
|
|
if not day:
|
|
return {"state": None, "coverage": 0.0}
|
|
max_v, min_v = max(day.values()), min(day.values())
|
|
# Montée du jour : la plus grande hausse depuis un minimum antérieur ; la fin de nuit est ce minimum.
|
|
# (Le maximum du jour peut être la queue de la soirée précédente, à 00:00 : il ne sert pas de repère.)
|
|
low = night_end_h = min(day)
|
|
rise_v = 0.0
|
|
for h in sorted(day):
|
|
if day[h] < day[low]:
|
|
low = h
|
|
if day[h] - day[low] > rise_v:
|
|
rise_v, night_end_h = day[h] - day[low], low
|
|
night_end_v = day[night_end_h] if rise_v else min_v # sans montée : le point le plus bas du jour
|
|
hours_full = sum(v >= FULL_CHARGE_V for v in day.values())
|
|
coverage = len(day) / 24
|
|
# Les états 1 et 2 reposent sur une valeur mesurée : ils passent avant la couverture minimale.
|
|
if hours_full:
|
|
state = "FULL_CHARGE"
|
|
elif min_v < PLATEAU_FLOOR_V:
|
|
state = "BELOW_PLATEAU"
|
|
elif coverage < MIN_COVERAGE:
|
|
state = None # UNKNOWN : trop de trous pour conclure à une absence
|
|
elif rise_v < MIN_RISE_V:
|
|
state = "NO_CHARGE"
|
|
else:
|
|
state = "PARTIAL_CHARGE"
|
|
return {"state": state, "max_v": round(max_v, 3), "min_v": round(min_v, 3), "night_end_v": round(night_end_v, 3),
|
|
"rise_v": round(rise_v, 3), "hours_full": hours_full, "coverage": round(coverage, 3)}
|
|
|
|
|
|
def run(series):
|
|
"""Analyse DAILY_BATTERY_STATE, causale : le jour d n'utilise que les heures de d. Un point par jour UTC."""
|
|
v = series["BusVoltage"]
|
|
if v:
|
|
t0 = min(v)
|
|
if any((t - t0) % HOUR for t in v):
|
|
raise ValueError("BusVoltage : horodatages hors de la grille horaire")
|
|
days, last = defaultdict(dict), {}
|
|
for t in sorted(v):
|
|
last[t.date()] = t
|
|
x = v[t]
|
|
if x is not None and math.isfinite(x): # NaN/inf (ex. export pandas) = pas de mesure
|
|
days[t.date()][t.hour] = x
|
|
points = []
|
|
for d in sorted(last):
|
|
facts = day_facts(days.get(d, {}))
|
|
points.append({"t": last[d], "value": facts.get("max_v"), "anomaly": None, "facts": facts})
|
|
return {"analysis": RULE["id"], "rule": RULE, "points": points}
|