The night end and rise were anchored on the first daily maximum,
which can be the 00:00 tail of the previous evening: 2026-05-05 was
read NO_CHARGE despite a +0.079 V rise, 2026-09-30 showed a wrong
night end, and 2026-09-26 stayed unknown from 04:00 to 11:00 when
evaluated mid-day. The rise now starts from an earlier minimum and
the knee is tested on the daily minimum (min_v). VERMONT: 139 / 31 /
14 / 0.
Docs: sheet 02 page order, battery_state.py in the CLAUDE.md map,
phase C exception to "anomaly = None means UNKNOWN".
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
calcul causal : le point t n'utilise que les données ≤ t ;
anomaly = None signifie UNKNOWN (exception : analyse 03 en phase C, où None = pas de verdict ; l'UNKNOWN est dans facts.state) ;
une analyse seule conclut au plus consistent with.
Code de calcul : bibliothèque standard uniquement, car il doit tourner sur la station. Plotly ne sert qu'aux graphiques, sur le poste de dev (.venv).
Constantes : chacune a sa source, en commentaire dans le code et dans le tableau de la fiche. Aucun seuil sans source.
Graphique :
en haut, l'analyse avec ses courbes superposées ; dessous, un graphique par série temporelle (D-011). Des analyses à comparer partagent une page, un panneau chacune (D-016) ;
zoom horizontal seulement, avec l'ordonnée recalée sur la plage visible (post_script=energy_plot.AUTOSCALE_Y_JS, ordonnées en fixedrange, D-013).
Après modification :
mettre à jour la fiche dans le même changement (résultats, limites, historique) ;
si c'est une décision projet, ajouter une entrée dans docs/decisions.md ;
si c'est un savoir métier nouveau, l'ajouter dans docs/domaine/.
Vérifier à la main avec python3 src/analyse_NN.py sur VERMONT (data/). Pas de tests automatisés en phase prototype (D-008).
Nouvelle analyse : utiliser le skill nouvelle-analyse.