# Instructions to the analyst (support)
## Why this range
The client of NADELHORN received two "vertical shift" alarms, on the targets **m_c7_mon** and **m_c10_mon**, within 2026-11-18T05:39Z → 11:16Z (UTC). The expert asks the support for a short mail to the client that diagnoses the range: did these targets really move vertically, or is it a measurement artefact (visibility, obstruction, camera / reference movement, thermal), and how sure.
Read the range; widen it if needed to see the level before and after (e.g. from the evening before), and say so.
## Your labels
They stay in your output folder (`analyst/`). Never write in `labeling/auto/<STATION>.jsonl` nor anywhere else in `labeling/`.
## What you answer me
In a few lines:
- the facts that answer the question: when (UTC, start / extreme / end), which targets (m_c7_mon, m_c10_mon, and whether others share it), the size of the vertical shift (px and mm if available), whether it comes back, the cause and how sure (confirmed / likely / possible / unknown), what the images show;
- the path of your analysis, and the paths of the **one or two figures** that best show the problem to a client (a curve of the corrected vertical position of m_c7_mon and m_c10_mon with a witness target, and/or an image or thumbnails showing the cause); keep them readable for a non-specialist;
- what you saw outside the question.