You asked to requalify the labels of 10/10 16:15 to 21/10 10:30 (UTC) under the new rules: keep only what stands out from the noise of the corrected curves.
All 33 labels stand out clearly from the noise: they all stay, unchanged.
Do not trust the curves during the two rain episodes, the night of 19 to 20/10 on the three near targets, the nights the references blur (13, 14, 15, 17/10) and the measurement around 16:00 on sunny afternoons.
No real movement of the structure is seen; the rest is the daily thermal movement of the bridge.
**Daily thermal movement of the bridge (every day, confirmed).** The bridge sinks as it warms by day and rises as it cools at night. The corrected curves keep this movement well beyond their noise: about 1.5 to 4 mm per half-day on PM_C and PM_D (21 m from the camera), up to 2 mm on the BL targets (34 m). From 16 to 18/10, as the weather cools, the bridge rises for two nights in a row. This is normal.
**Fixed reference points seen less well at night (13, 14, 15 and 17/10, cause not established).** On these very humid nights without rain, two of the three fixed reference points blur. The whole correction shifts and all targets move a little together: about 1 mm on the far targets. On the night of 14 to 15/10 both references are lost for hours: the targets jump by up to about 3 mm and every point is wrong.
**Sun behind a reference (12, 14, 15, 16/10, confirmed on the images).** Around 16:00 on sunny afternoons, the sun lights the background behind a reference for one measurement. All curves make a small jump, about half a mm on the far targets, and come back.
**Rain (18/10 10:00 to 19/10 10:15, and 20/10 14:15 to 21/10 09:15, confirmed).** The whole scene is seen less well; the curves become agitated, up to about 3 mm on BL_C. Rain was measured all those hours at the MeteoSwiss station of Nyon / Changins, 2 km away, and the road is wet on the camera image.
**Three near targets seen less well on a humid night (19/10 16:15 to 20/10 11:00, likely).** BJ_C, BJ_D and BJ_G, 8 m from the camera, are seen less well the night after the rain. In step with it, BJ_D and BJ_G seem to move apart by about 1 to 2 mm, and all three seem to drop. The temperature and the camera do not move that night: it is not a movement.

**Missing measurements (6 gaps).** On 14 and 15/10, one measurement is missing at this station only, cause not established. On 16/10 (night and 13:45) and 19/10 (morning and evening), the gap falls on the other stations too: a common cause outside the station.
- **Why the references blur on humid nights** (13-17/10): a look at the reference prisms on site would settle it.
- **BJ_D and BJ_G at night**: part of their night spread follows how well they are seen, not a movement; comparing nights with the same error at different temperatures would tell.
Each label was measured against the noise of its targets: the weakest are the one-measurement jumps and the night reference episodes, at 5.6 to 9.4 times the noise; the thermal phases are at 11 to 83 times; the rain and the loss of references at 17 to 58 times. The six missing-measurement labels are moments when the station delivers nothing at all. None of the labels rests on rejected points alone.