This analysis first checked the 19 existing labels (all reviewed 2026-11-17) and added FLORIDA-79. It was then **requalified** under the new rule (`labeling-rules.md`, section 1): only what stands out from the noise of the corrected curves is labelled, at more than 5 of the target's own noises. Result: **18 labels kept unchanged, 0 rewritten, 2 removed** (FLORIDA-47 and FLORIDA-52). See "## Requalification" below.
Weather: FLORIDA has no `weather/` folder, so no weather is available.
Targets (`inventory.py`): Sellette 3 (33 m, 6.5 mm/px, twin of p1_r), Sellette 4 (48 m, 9.6 mm/px), Sellette 5 (64 m, 12.8 mm/px), Sellette 6 (80 m, 15.9 mm/px, Target issue FLORIDA-1), Massif 2 (99 m, 19.6 mm/px, Target issue FLORIDA-14), Pont Ernen (373 m, 74 mm/px, twin of r1_r). Only two references, p1_r and r1_r. The twins are not labelled for themselves. Their corr sits at zero with a near-zero noise, so a deviation "in noises" means nothing for them. The Target issue targets are read but are not used alone to justify a label. The requalification therefore rests on Sellette 4 and Sellette 5.
## Verdict per old id (first pass, then requalification)
- FLORIDA-46 (22 03:15→03:45, Displacement): **kept**. Sellette 4 corr_x steps up at 03:30 and stays. Against the night before, this is +11.7 noises at the extreme, 22 measurements above 5 noises on the morning, and a jump of 6.8 noises.
- FLORIDA-47 (22 08:45→17:00, Thermal): **removed** at requalification: the thermal movement is compensated (details in section 2).
- FLORIDA-52 (24 01:45→02:15, Visibility, r1_r lost for one measurement): **removed** at requalification: the curves do not move (details in section 2).
- FLORIDA-53 (24 07:00→14:45, Visibility, r1_r lost): **kept**. Against the level outside the episode, Sellette 5 reaches +7.5 noises (12:00–14:30) and Sellette 4 +6.9.
- FLORIDA-56 (26 11:45→19:00, Thermal): **kept**. Sellette 5 corr_y is above its night level by up to +7.9 noises at 14:00, with 15 measurements around the maximum.
- FLORIDA-57 (26 14:30→15:15, No data): **kept**. The two steps at 14:45 and 15:00 are absent for all sensors.
- FLORIDA-58 (27 01:45→11:45, Visibility, r1_r): **kept**. Sellette 5 reaches −7.2 noises at 02:15 and +5.3 noises at 06:15–06:45. Sellette 4 reaches −6.3 noises.
- FLORIDA-59 (27 09:00→09:30, No data): **kept**. The 09:15 step is absent for all sensors.
- FLORIDA-60 (27 11:30→20:00, Thermal): **kept**. Against the night level, Sellette 5 corr_x reaches −8.8 noises at 12:45 and Sellette 4 −6.5.
- FLORIDA-79 (28 10:15→19:45, Thermal, not reviewed): **kept**. Sellette 5 corr_y reaches +6.4 noises over its night level at 11:15, with 17 measurements above 5 noises from 09:15 to 15:00.
- FLORIDA-62, 63, 64 (29, 30, 31, Thermal): **kept**. Sellette 5 corr_y reaches +8.1, +8.8 and +9.1 noises over its night level.
- **Precedents**: FLORIDA-56 and FLORIDA-60 (same station; a thermal label that starts at the last rejection of the morning r1_r loss) and FLORIDA-62 to 64 (same shape). `precedents.py` was not run (usage limit in the first pass).
- **Family**: Thermal displacement. The pose and Sellette 5 corr_y follow the housing temperature (19.7 → 24.3) and come back with it. error_value stays at its level.
- **Measured**: rotation goes from about +0.01 at night to −0.014 at 12:00–14:00, then is back to +0.005 at 19:30. Tilt goes from +0.006 to +0.017. Pan stays flat. Sellette 5 corr_y is above its night level by up to +6.4 noises at 11:15 (`days.py --bounds`), with 17 measurements above 5 noises from 09:15 to 15:00. That is about +0.09 px, or about 1.2 mm.
- **Images**: none (not looked at, usage limit in the first pass).
- **Confidence**: medium. The cycle is clear on the pose, and it clears the threshold, but by a small margin.
- **FLORIDA-47, 2026-10-22T08:45Z → 2026-10-22T17:00Z, Thermal displacement: removed, compensated thermal.** The pan drifts with the housing temperature, but the compensation absorbs it.
- **Sellette 5:** against the night of the 21st, corr_y peaks at +2.9 noises (14:30). Its corr_x exceeds 5 noises only at 13:00–13:15 (+5.3), which is inside FLORIDA-48, the loss of r1_r.
- **Sellette 4:** against its level after the step of FLORIDA-46 (`ranges.py --rolling 1d`), it passes 5 noises only at 06:00 (+5.1, a single point before the cycle) and at 13:00–13:15 (FLORIDA-48).
- **Sellette 6:** its corr_y reaches +8.9 noises (15:00–17:00), but it is under its Target issue (FLORIDA-1). It was rejected from 09:00 to 14:45 that day, so its curve is unreadable and does not carry a label alone.
- The label's own description already said that the corrected curves show almost nothing.
- **FLORIDA-52, 2026-10-24T01:45Z → 2026-10-24T02:15Z, Visibility: removed, missing points only.** r1_r and Pont Ernen are rejected at 02:00 for one measurement. Against the local level (`ranges.py --rolling 8`, 23 20:00 → 24 05:00), nothing exceeds 5 noises around 02:00. At 02:00, Sellette 5 corr_x is 0.110 against a level of 0.110 (0 noises). Sellette 6 is at 0.180 against 0.156 (about +1 noise), and Sellette 4 at 0.190 against 0.190 (0 noises). Nothing moves in corr_y either. The earlier ranges in that window (Sellette 4 at 00:00–01:00, Sellette 5 at 22:45) belong to FLORIDA-51.
### Unchanged from the first pass
- **23rd, 09:15–12:15.** Rotation goes to −0.02 as the temperature rises to 20.5, then the mist starts. This is −3.1 noises, and Sellette 5 corr_y does not move: no thermal label.
- **24th.** No thermal cycle above 5 noises against the night level: Sellette 5 corr_y peaks at +4.8 noises and corr_x at +2.3. The pose is mostly absent.
- **25th.** The cycle is masked by the rain (FLORIDA-54).
- **29th–31st, evenings.** Sellette 5 corr_y goes 6 to 8 noises below the window level from 18:00 to 23:45. This is the lower night level after the warm days (the next night minus the reference night is −1.2 to −2.8 noises), not an event of its own.
- **Sellette 6 and Massif 2.** Both are under their Target issue labels (FLORIDA-1, FLORIDA-14). Their large excursions while accepted (for example Massif 2 corr_y +17 noises on the 26th to 28th) are read as part of these regimes.
- The 5-noise rule removed the two labels whose own description said there was no effect on the curves (FLORIDA-47) or only one missing point (FLORIDA-52).
- For a jump-and-return, the level must be measured outside the episode (`ranges.py --outside`). The window level over ten days hid FLORIDA-53: Sellette 4 at 5.1 and Sellette 5 at nothing against the window, but +6.9 and +7.5 noises locally. For a step (FLORIDA-46), the level must be read against the night before. Against several days before, the step is only about 2.4 noises, because the earlier days sat at another level.
- What is missing: the rules do not say whether a Target issue target (here Sellette 6, rejected half the time) may alone carry a movement label. I did not let it, following the thermal description rule ("without those that a Target issue makes unreadable").
- On a two-reference station, every loss of r1_r gives Sellette 4 and Sellette 5 the same, repeatable offset, close to the threshold (about 5 to 7 noises). The one-measurement loss at 02:00 on the 24th gave none.
## Requalification
Commands (from the repository root, `--out` in `work/rq`):
-`.venv/bin/python tools/scripts/days.py data/FLORIDA --columns corr_x,corr_y --sensors <target> --bounds --start 2026-10-21T00:00Z --end 2026-11-01T00:00Z`, run for Sellette 4, Sellette 5, Sellette 6 and Massif 2 → `work/rq_days_*.txt`. This gives the thermal deviation from the night level.
-`ranges.py --sensors "Sellette 4","Sellette 5" --start 2026-10-21T20:00Z --end 2026-10-22T09:00Z --outside 2026-10-22T03:30Z/2026-10-22T09:00Z` (FLORIDA-46), and with `--rolling 1d` to 23 03:00 (FLORIDA-47).
- First pass: the usage limit was reached, so no images were looked at for FLORIDA-79, no precedents query was run, and no GIF was made.
- Requalification: the rule does not say which level to use for a step or a jump-and-return: the window, outside the episode, or the night before. I used the local level outside the episode, and the night before for the step.