All four labels stand out from the noise and stay as they were. None of them is a movement of the structure. Do not trust COLH21' and REFH22' before 5 October 16:00, or any target after 9 October 12:00, when only two references are left.
**A badly placed pair of targets (3 to 5 October, confirmed).** COLH21' and REFH22' both measured the gap between two spots, not their own spots. Their corrected curve in y sat about 2 to 3 mm below their neighbours'. At 16:00 on 5 October they were set back on their own spots, and the curve jumped by about 2.4 mm (COLH21', 40 m away) and 3 mm (REFH22', 51 m away). Their curves from before cannot be compared with those from after.
**The camera moves when its housing cools (5 and 6 October, likely).** Both nights, the temperature in the camera housing dropped by about one degree. The camera nodded a little, and the corrected curves of all the targets moved together for a few hours. They came back when the temperature rose. The deviation is small: about 0.3 mm on the 5th (targets 19 m away), 0.6 to 1 mm on the 6th (targets 30 to 42 m away). That is just above the station's ordinary noise. The targets did not move relative to each other.
**The camera slowly tilts forward (8 to 12 October, likely).** Over these days the camera keeps nodding forward. The cameras of BREITHORN and NEBRASKA, in the same building, do the same. With three references, the correction cancels most of this movement, and from 8 October a small part gets through. On 9 October at 12:00 the reference REFPOU22 is lost. From then on, with only two references left, the corrected curve in x of every target climbs steadily and jumps back and forth from one measurement to the next. At its worst (11 October 12:00), the curves are off by about 0.6 mm for the nearest targets (9 m) and up to about 4.7 mm for the farthest (41 m). The shift in the image is about the same for every target, so the error in mm grows with distance. That is what a turning camera does, not a moving structure. No weather data exist for this station (it is indoors).
- Why the cameras of the building tilt. Temperature does not explain it on its own. Comparing the three cameras over several months would settle it.
## Requalification
Kept: 4. Rewritten: 0. Removed: 0.
Each label has at least one target more than 5 times its own noise away from its usual level. The pair on 5 October: 16 noises. The night of 5 October: 5 to 6. The night of 6 October: 5.5 to 6. The tilt: up to 22 noises after 9 October.