Requalification, under the new rules (`labeling-rules.md` section 1: only what stands out from the noise of the corrected curves), of the 4 labels of this analysis (`work/requalify_input.jsonl`, all reviewed by the user on 2026-11-17). The reading was not redone: the verdicts of the previous analysis (kept in `work/analysis.before-requalify.md`) stand. Each label was checked against the 5-noise threshold only. Result: **4 kept unchanged, 0 rewritten, 0 removed**. `labels.jsonl` is the input without the id field, review fields included.
Context. One measurement every 4 h (52 instants in the range, 3 missing). REFCOLH22 is rejected at every measurement, so the compensation runs on REFH22 and REFP''21 only (the long label NEBRASKA-2). The image quality columns are empty on this camera. **Weather**: NEBRASKA has no `weather/` folder, so there is no MeteoSwiss data. The station is indoors anyway. Distances and mm per px (`inventory.py`): POUJ20 7.9 m (3.10 mm/px), COLJ20 8.6 m (3.37), COLJ19 10.9 m (4.21), POUJ19 11.7 m (4.64), POUH19 16.8 m (6.72), POUH20 30.8 m (12.14), POUH21 37.8 m (14.87). COLH19, COLH20 and COLH21 have no sure factor (`?`), so they are given in px only.
- **Phenomenon of the catalogue**: "The camera tilts little by little" (here a pause and a slight backward movement), with "A compensation on two references".
- **Family**: Displacement. It does not come back at equal temperature, and its cause is not established, so it is not Thermal.
- **Measured**: `ranges.py --k 5` over 10-10 → 17-10 20:00 with the level computed outside the label (`--outside 2026-10-13T04:00Z/2026-10-17T04:00Z`). In corr_y: COLJ20 +7.7 noises (14-10 00:00, +0.100 px, about 0.34 mm), COLH19 +7.4 (14-10 00:00), POUJ19 +6.7 (14-10 00:00, +0.071 px, about 0.33 mm), POUH19 +6.4 (14-10 00:00, about 0.42 mm). COLJ20 and COLH19 stay beyond 5 noises at several instants up to 16-10 16:00. COLJ23's ranges come from its quantised corr_y (noise 0.0014 px, values on two levels): they are not part of the event. Previous verdict (bounds, pose, link with BREITHORN and MICHIGAN): unchanged.
- **Images**: 13-10 04:00 and 08:00 (previous analysis). Same scene, nothing in front.
- **Confidence**: high on the threshold and the bounds. The cause stays not established.
- **Family**: No data. The station delivers no measurement at all.
- **Measured**: `inventory.py --start 2026-10-15T12:00Z --end 2026-10-16T16:00Z`: 3 missing instants, between 15-10 20:00 and 16-10 12:00, for all the sensors (no partial curve). This is still a real No data under the new rule.
- **Measured**: the COLJ19 corr_x jump from 16-10 20:00 to 17-10 00:00 is +0.074 px, 6.6 noises with the noise of the whole range and 11.1 noises with the noise outside NEBRASKA-3 (`ranges.py`). Against the level outside NEBRASKA-3, COLJ19 corr_x stays out: +10.5 noises at 17-10 00:00, 8.0 to 10.3 from 04:00 to 16:00, +6.5 at 20:00 (half way back). That is about +0.29 mm at its peak (4.21 mm/px). `ranges.py --rolling 3` does not flag it, because a step that lasts five measurements is followed by a level of ±3 measurements. A lasting jump is measured against its level before, so the outside run is the right one here.
- **Images**: fixed thumbnails (previous analysis). Nothing in front, and the shift is too small to see.
- **Measured**: the corrected curves keep the movement beyond 5 noises.
-`ranges.py --k 5` over the whole range, with no rolling, at 19-10 08:00: POUH20 corr_y +7.0 noises, COLH21 corr_x +6.5, POUJ19 corr_y +5.7, COLJ20 corr_x +5.2. corr_y has no drift over the range that would bias this level. corr_x does: POUH20, COLJ20 and POUJ20 stay above it from 18-10 to the end, which is NEBRASKA-6.
- Against the night level before the cold morning (17-10 20:00 and 18-10 00:00, read in `work/corr_y.txt`, noise of the whole range), at 19-10 08:00: POUH20 corr_y +6.7 noises (+0.083 px, about 1.0 mm), POUJ19 corr_y +6.5 (+0.111 px, about 0.5 mm), COLJ19 corr_y +5.6 (about 0.23 mm).
- Against the daytime level of 18-10 (04:00 to 16:00; `scripts/thermal_dev.py`, `work/requal/n7_dev_preday.txt`): POUH21 corr_x +6.6, POUJ19 corr_y +6.0, POUH20 corr_y +5.6, COLJ19 corr_y +5.5.
- Against a level that brackets the event (18-10 16:00, 19-10 20:00 and 20-10 00:00), which also removes the drift underneath (`n7_dev_bracket.txt`): COLJ19 corr_y +5.0, COLH21 and POUH21 corr_x +4.9. This is at the threshold, because the curves come back a little higher than they left.
-`ranges.py --rolling 3`, `--rolling 6` and `--rolling 1d` flag nothing. The bump lasts about six measurements, as long as the rolling windows, so these windows absorb it. They do not measure this event.
- So the label holds, but only just. I keep it unchanged.
- **Images**: 19-10 00:00 and 08:00 (previous analysis). Indoor scene intact.
- **Confidence**: medium. The label is above the threshold against the levels before the event, and at the threshold against a level that brackets it.
**No label was removed.** None of the four labels rests on missing points, and none is a camera movement that the compensation absorbs:
- NEBRASKA-3: up to 7.7 noises (COLJ20 corr_y). Kept.
- NEBRASKA-4: no measurement at all on the station. Kept.
- NEBRASKA-5: up to 10.5 noises (COLJ19 corr_x). Kept.
- NEBRASKA-7: up to 7.0 noises against the range level, and up to 6.7 against the night before (POUH20 corr_y); 5.0 against a bracketing level. Kept.
What the previous analysis left without a label is still below the threshold, and was not looked at again (no search for new events):
- 20-10 04:00–08:00: a small corr_y dip of the top targets, under 5 noises (median corr_y −2.9).
- 17-10 08:00: a small corr_x peak, below 5 noises.
- 17-10 00:00: a corr_y rise on COLH21 and COLH20, about 4 to 5 noises.
- 18-10: a small step of POUH20 corr_x. In `ranges.py --rolling 3` it reaches 5.3 and −5.4 noises at 18-10 04:00 and 16:00, single points inside the drift of the long label NEBRASKA-6, which describes POUH20 rising with the tilt.
-`labeling-rules.md` section 1 was clear on the threshold. One gap: for a thermal bump that lasts about one day at a 4 h cadence, `--rolling` (named for thermal cycles) absorbs the bump itself. The night level asked for by the rule had to be computed by hand from the per-instant tables. A `ranges.py` option for "level = the night before" (like `days.py --bounds`, but per target) would settle such cases directly. `days.py --bounds` works on the median of the targets, which hides a deviation carried by two or three targets (there: never above 3.7 noises).
- The full-range level of `ranges.py` without rolling is biased in corr_x by the long drift (NEBRASKA-6). It is usable in corr_y here, which has no drift.
- No precedent was looked up again: the families and the bounds are unchanged.
## Requalification
Commands (output in `work/requal/`):
-`python3 tools/scripts/ranges.py data/NEBRASKA --columns corr_x,corr_y --k 5 --start 2026-10-13T00:00Z --end 2026-10-22T00:00Z` → `full.txt`: at 19-10 08:00, POUH20 cy +7.0, COLH21 cx +6.5, POUJ19 cy +5.7, COLJ20 cx +5.2; the COLJ19 cx jump at 17-10 00:00 is 6.6 noises.
| NEBRASKA-7 | 18-10 16:00 → 19-10 16:00 | Thermal displacement | 7.0 (POUH20 cy, range level); 6.7 vs the night before; 5.0 bracketing | kept |
`validate.py`: 0 errors. It reports 1 overlap to look at, NEBRASKA-3 with NEBRASKA-5. These are two distinct events (a camera bump of the top group, and COLJ19's own jump), and the overlap already existed.