23 of the 28 labels stay; 5 are removed because the corrected curves stay within their noise there. The curves cannot be trusted during the jumps of the night of 11–12 October, the poor-visibility episodes of 18–19 and 20–21 October, and the outages. No real movement of the structure is seen.
Kept 23, rewritten 0, removed 5. A label stays when at least one target moves more than 5 times its own noise.
- FLORIDA-30 (15/10, slow level change): removed. The return it described is slow and stays under the threshold: 4.9 times the noise at most (about 1.3 mm).
- FLORIDA-33 (16/10, thermal cycle): removed. The camera moves with the heat, but the correction absorbs it: 4.5 times the noise at most.
- FLORIDA-36 (17/10, thermal cycle): removed. Same reason: 4.0 times the noise at most for Sellette 4 and Sellette 5.
- FLORIDA-38 (18/10, thermal cycle): removed. There is no cycle in the corrected curves. Only two single-point spikes of Sellette 4 at 10:15 and 10:30 cross the threshold (8.7 and 5.2 times the noise). They are not part of the cycle; they are left for a later analysis.
- FLORIDA-43 (20/10, Sellette 5 hidden): removed. Sellette 5 was only rejected (its curve is missing), and no other curve moved (1.3 times the noise at most).
**Reference p1_r measured off at night (12/10).** At 00:45, 02:00, 02:45, 04:00 and 06:30, then at 22:30, the reference p1_r was measured at a slightly wrong position. The corrected curves of Sellette 4 and Sellette 5 then jump by about 1 to 2 mm for one measurement (6 to 10 times their noise). The targets themselves do not move. A small bright point next to p1_r is there on the images at the hours without a jump and gone at the hours with one. The cause is likely, but what the point is remains unknown.
**Daily heat cycle.** On the 11th, 12th, 13th, 14th, 15th, 19th and 20th, the camera turns a little as its housing warms up. The correction does not absorb it entirely: the corrected curve in x of Sellette 5 (about 670 m away) goes down by about 1.5 to 3 mm during the day and comes back in the evening. On the 16th, 17th and 18th, the correction absorbs it, so there is no label. Confirmed. This is normal.
**Poor visibility (18/10 morning, night of 18–19/10, 20/10 afternoon to 21/10 evening).** The spots of the targets and the references get weak, probably from dampness or mist. Several targets and the references are rejected, and the kept measurements of Sellette 4 and Sellette 5 jump by up to 3 to 5 mm. Likely. The 11/10 at 10:00 the reference r1_r was rejected for one measurement and Sellette 5 jumped by about 1 mm (just above the threshold). There is no weather data for this station.
**Outages.** No measurement at all on 14/10 around 01:30, on 15/10 around 02:00 and 02:30, from 15/10 23:00 to 16/10 10:45, on 16/10 at 13:45 and 14:30, on 19/10 from 09:15 to 10:00, and on 19/10 at 21:00. The same gaps hit other stations at the same moments, so the cause is probably outside the station. Not established.