You asked to requalify the labels of 23/08 05:15 → 04/09 06:15 (UTC) under the new rules: keep only what stands out from the noise of the corrected curves.
Most labels hold: 35 stay as they were, 3 are reworded, 4 are removed because nothing stood out from the noise there.
The corrected curves can be trusted outside the labelled moments: the cobweb nights (27-28/08, 03-04/09), a few short jumps by day and at night, and the mornings when the camera warms up.
**The camera moves every day with the heat of its housing** (10 of the 12 days). In the morning the housing warms up and the camera turns a little; it comes back in the evening and at night. The correction removes most of this, not all. The targets on the right of the group keep a dip of about 3 to 7 mm in the morning (PR18 most, at 116 m; PR16 and PR15 less), then come back in the afternoon. On 30 and 31/08 the dip is only about 1 mm, just above the noise. On 28/08 and 03/09 the correction absorbed the movement fully: these two days are no longer labelled. Confirmed: the camera follows the housing temperature, and a rock face cannot move like that.
**Cobwebs and a spider in front of the lens** (night of 27-28/08, and 03-04/09 around 23:00). Lit by the infrared, threads cross the bottom of the image. The targets nearby shift by about 2 to 3 mm for a while (PR08, PR06, PR05; PR16, PR15, PR14 on 03/09). On 27/08 at 21:15 the spider itself passes in front of the lens: almost every target is lost or jumps for two measurements. Confirmed on the images. The day when a thread covered only PR07 (24-25/08) is no longer labelled: PR07 was simply missing, and the other curves did not move.
**Short jumps of several targets** (about fifteen moments, 26/08 to 03/09). For one to a few measurements, several targets jump by about 1 to 4 mm, then come back. They come with a weak PR07 that is lost, a noisy night image, the morning sun on a cobweb (26/08), or a whole image less clean in strong afternoon sun (28/08, 31/08, 01/09, when CTR01 is also lost in the sun). On 28/08 at 12:45 one of the three fixed references was lost and every target jumped by up to 12 mm for one measurement. Twice (29/08 12:00, 01/09 15:45) the camera made a small step that the correction did not quite follow. Causes partly seen, partly not established; none is a movement of the face, as the curves come back at once.
**Gaps in the measurements** (7 times: mostly one or two measurements at night around 01:00, and four hours on 28/08 morning). No target has a measurement then. The station kept running (normal voltage); some gaps fall at the same minutes on JUNGFRAU. Cause not established.
- The cause of the short jumps by day when the whole image is less clean for one measurement (28/08, 31/08): strong sun is likely; the image of each instant, compared on more days, would settle it.
- NORDEND-53 (Obstruction, 24/08 11:00 → 25/08 12:30), removed: only missing points of PR07; its loss moves no other curve (the deviations inside, up to 9 noises, belong to the camera's daily movement).
- NORDEND-248 (Thermal, 28/08 07:00 → 29/08 06:00), removed: movement absorbed by the correction; at most 4.4 noises for the camera cycle itself (5.9 only with the tail of another labelled episode).
- NORDEND-253 (Visibility, 31/08 15:45 → 16:15), removed: CTR01 missing for one measurement, no target beyond 5 noises.
- NORDEND-83 (Thermal, 03/09 06:30 → 04/09 06:15), removed: movement absorbed; at most 4.6 noises outside the cobweb labelled apart.
- NORDEND-66 (Visibility, 28/08 14:15 → 14:45), rewritten: now about the jump of PR18, PR09, PR14 (up to 7 noises, 2 mm) at the measurement when the whole image is less clean, not about CTR01's missing curve.
- NORDEND-252 (Visibility, 31/08 14:30 → 15:00), rewritten: same, PR18 and PR03 (up to 7 noises, 2 mm); it pointed to the removed NORDEND-253.
- NORDEND-79 (Visibility, 01/09 14:45 → 15:30), rewritten: about PR01, PR05, PR14 jumping (up to 7 noises, 3 mm) while CTR01 is lost in the sun.