auto: the analysts verified the labels of 32 periods (11 stations, up to 14 days each): 710 labels -> 835, 587 unchanged; one analysis folder per period with its report (section Verification)
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
df979301b5
commit
2a5d87659b
279 files changed
+10758
-710
No files matched your search
@@ -0,0 +1,111 @@
|
||||
# Labels: CLARIDEN, 2026-10-20T04:00Z → 2026-11-01T00:10Z (UTC)
|
||||
|
||||
The task was to verify the 21 labels already on the range (`work/existing.jsonl`, all reviewed 2026-11-17) and the one spanning label (CLARIDEN-1).
|
||||
|
||||
Result: 12 kept unchanged, 9 corrected, 0 removed, 3 added; 24 labels in `labels.jsonl`. Labels are built from `existing.jsonl` by `scripts/build_labels.py`, so the kept ones are byte-identical apart from the dropped `id`. `validate.py` reports 0 errors. Its 8 "overlaps to look at" are distinct events on different target rows (row C drift, row B moves, row A jolts and returns). A script checked that every bound is a measurement instant of the station (10 min rate, minutes :00 to :50).
|
||||
|
||||
## Verdict per existing id
|
||||
|
||||
| id | verdict | evidence |
|
||||
|---|---|---|
|
||||
| CLARIDEN-23 | kept | Residuals: D-301-C corr_x rises over 20→24/10. D-304-C and D-303-C corr_y rise from 22/10 to 25/10 (6 h medians: D-304-C from about −0.42 to −0.36). Rigid dx of D-301-C goes up to +0.13, so these targets move in the image relative to the others. Temperature flat (39.6 to 40.6 °C over the range). |
|
||||
| CLARIDEN-24 | kept | Inventory: one step missing between 06:10 and 06:30. |
|
||||
| CLARIDEN-25 | corrected | Bounds were 20:45 → 21:45, which are not measurement instants. The present instants are 20:40 and 21:40 (inventory: 5 missing). Now 20:40 → 21:40; description unchanged. |
|
||||
| CLARIDEN-26 | corrected | End was 08:45, not an instant. The last touched points are at 08:40 (D-303-B corr_y −0.042 against a level near +0.03; D-301-C corr_x −0.025). At 08:50 D-301-C is back and D-303-B is merging into the row B rise of CLARIDEN-28. End now 08:50. |
|
||||
| CLARIDEN-27 | kept | The scale reaches its minimum at 08:30–08:40 with the temperature dip of the 22nd (hourly 39.58 °C at 06:00). With days.py smoothing 5 the deviation is −4.5 noises, just under the rule of 5 noises. It is kept because it matches the reviewed precedents CLARIDEN-5 and CLARIDEN-13 (sharp housing drops in the tunnel) and individual points exceed the threshold. |
|
||||
| CLARIDEN-28 | corrected | Start was 08:45, not an instant. The row B rise is first seen after the visibility episode (D-306-B and D-303-B corr_y from 09:00). Start now 08:50. |
|
||||
| CLARIDEN-29 | kept | D-306-B corr_y drops on the evening of the 22nd and the morning of the 23rd: rolling ranges, residual chart, rigid dy −0.166 at 23/10 16:10. |
|
||||
| CLARIDEN-30 | kept | D-306-B and D-304-B corr_y partly rise again during the night of the 24th (6 h medians, residual chart). |
|
||||
| CLARIDEN-31 | kept | Pose jolts at 24/10 19:20 and 25/10 06:30–07:20 (days.py: pan −5.1 and −7.5 noises). Row A corr_y +0.06 to +0.1, corr_x −0.04 to −0.05 (6 h medians). The corr_x of row A stays shifted until the end of the range (D-301-A about −0.14 → −0.18). Row A corr_y also drifts up a little on the morning of the 24th; this is not enough to move the start. |
|
||||
| CLARIDEN-32 | kept | D-304-C corr_y goes from −0.36 (25/10) to −0.43 (29/10), D-303-C from −0.04 to −0.09, then flat. |
|
||||
| CLARIDEN-33 | corrected | End was 15:15, not an instant. Instants present at 14:30 and 15:10, 3 missing. Now 14:30 → 15:10. |
|
||||
| CLARIDEN-34 | kept | 09:00 and 09:30 present, 2 missing. |
|
||||
| CLARIDEN-35 | kept | PR-284 corr_x jumps +15.3 (570 noises) and corr_y +11.9 at 12:10 only. Bounds 12:00 → 12:20 are right. |
|
||||
| CLARIDEN-36 | kept | Hourly corr_y: D-306-B goes from +0.045 to −0.015 and D-304-B from −0.047 to −0.07 between 18:00 and 20:00 on 28/10. D-303-B corr_x steps down (residual chart). |
|
||||
| CLARIDEN-37 | kept | 14:50 and 15:10 present, 1 missing. |
|
||||
| CLARIDEN-38 | corrected | Bounds were 23:45 → 00:15, not instants. At 10 min the jump is between 23:50 (old level: D-302-B corr_y 0.050, PR_BG 0.050) and 00:00 (D-302-B 0.247, PR_BG −0.033). Raw y does not change; relative_y jumps (D-302-B −0.15 → +0.06). Now 23:50 → 00:10; description unchanged. |
|
||||
| CLARIDEN-39 | corrected | End was 17:45, not an instant. Present at 17:00 and 17:50, 4 missing → 17:00 → 17:50. The description only said "cause not established", against rule 5 ("A No data states the metrics and the image…"). Now it states that the gap is CLARIDEN's own: ALASKA, FLORIDA, JUNGFRAU, LENZSPITZE, NADELHORN, NORDEND, SNCF01 and WYOMING all measured. `last_sync` has no entries from 17:09 to 17:40, so the station itself stops recording. The 17:00 image exists. BusVoltage stays at 14.35–14.36 V. |
|
||||
| CLARIDEN-40 | corrected | Start was 13:45, not an instant. First touched point at 14:00 (D-301-C corr_x −0.093 against +0.01 at 13:50; D-302-B corr_y 0.315 against 0.262). Start now 13:50. End 15:10 holds: at 15:00 D-302-B corr_y is still 0.30, halfway; at 15:10 it is back at 0.265. |
|
||||
| CLARIDEN-41 | corrected | Start was 18:45. First touched point at 18:50 (D-301-C corr_x −0.070, D-302-B corr_y 0.33, PR-295 corr_x 0.054). Start now 18:40. End 20:00 is right: PR-295 is rejected at 19:50. |
|
||||
| CLARIDEN-42 | corrected | Start was 22:15. PR-295 is rejected from 22:30 (a touched reference) and is not rejected at 22:20. Start now 22:20; end 00:00 holds (P-301-B −5 noises at 23:40, curves crossing until 23:50). |
|
||||
| CLARIDEN-43 | kept | Scale min at 23:30 (0.999787) with the housing drop (hourly 38.4 °C at 23:00). Pattern of the reviewed CLARIDEN-5 and -13. |
|
||||
| CLARIDEN-1 (spanning) | holds | P-300-B is rejected at all 1690 instants of the range (inventory). Nothing to say. |
|
||||
|
||||
## 1. My labels
|
||||
|
||||
Kept and corrected labels are justified in the table above. Below are the three added labels.
|
||||
|
||||
### 2026-10-25T19:10Z → 2026-10-29T04:00Z
|
||||
- **Phenomenon of the catalogue**: "Targets move slowly, alone, then come back" (the return leg).
|
||||
- **Precedents**: CLARIDEN-15 (return of the row C drift of 6–11/10, labelled separately and naming the outward label) and CLARIDEN-32 (same dates, row C). Both guided the wording and the "return labelled apart" structure.
|
||||
- **Family**: Displacement. The cause is not established. Temperature is flat (39.6 to 40.6 °C), so this is not Thermal displacement. The image is good and nothing hides the targets, so it is not Visibility.
|
||||
- **Measured**: 6 h medians of corr_y.
|
||||
- D-304-A goes from −0.03 (23/10) to +0.09 (25/10 12:00), +0.058 (26/10 06:00), +0.022 (28/10 00:00), −0.020 (29/10 00:00), then fluctuates between −0.045 and +0.007.
|
||||
- D-303-A goes 0.05 → 0.13 → 0.05.
|
||||
- D-301-A goes −0.09 → −0.02 → −0.09.
|
||||
- D-302_A goes 0.03 → 0.09 → 0.02.
|
||||
- P-299-A and P-298-A follow less.
|
||||
- corr_x of row A stays shifted, as CLARIDEN-31 says.
|
||||
- Rigid residual dy: D-304-A max +0.126 at 25/10 19:50 and +0.037 at the end; D-303-A +0.084 → +0.014; D-301-A +0.072 → +0.026. The targets come back in the image with their curves.
|
||||
- No pose step on these days.
|
||||
- The end is aligned on CLARIDEN-32. At 29/10 04:00 the hourly values are within the later fluctuation.
|
||||
- **Images**: none looked at specifically for these days; the 28/10 19:00 and 20:00 images were described in CLARIDEN-32.
|
||||
- **Confidence**: medium. The return is clear on the 6 h medians, but it is gradual and the end is fuzzy within a few hours.
|
||||
|
||||
### 2026-10-30T18:10Z → 2026-10-30T18:30Z
|
||||
- **Phenomenon of the catalogue**: "A reference dropped: the base changes", in a variant where the reference is not dropped but shifts under its threshold.
|
||||
- **Precedents**: WYOMING-17 (reviewed): references jump alone for one measurement, the targets' raw positions do not move, the compensation passes the jump into the targets; Displacement, cause not established. NIEDERHORN-126: same family and wording for a reference rejected once.
|
||||
- **Family**: Displacement. No object is seen or deduced, so not Obstruction. The scene is not degraded (error_value of the targets flat), so not Visibility.
|
||||
- **Measured**:
|
||||
- At 18:20, corr_x jumps against 18:10: D-300-A −0.117 → −0.211, D-301-A −0.167 → −0.236, D-302_A −0.266 → −0.340, D-303-A −0.036 → −0.126, D-304-A −0.105 → −0.200, P-298-A −0.045 → −0.093, P-299-A −0.098 → −0.140, PR-283 and PR-284 about −0.06. D-303-C and D-304-C move about +0.03.
|
||||
- Everything is back at 18:30.
|
||||
- Raw x of the targets does not change (D-301-A 531.43; D-303-A 294.6).
|
||||
- Reference PR-291: raw x 991.53 → 991.63 → 991.57; rigid dx +0.0845, its maximum of the range. Its error_value is 0.089 → 0.142 → 0.121, under the 0.7 threshold. The other references are unchanged.
|
||||
- corr_y is not visibly affected.
|
||||
- **Images**: 18:00 (whole image) shows the targets and the frame at the top, nothing in front. 19:00 exists. No image at 18:20.
|
||||
- **Confidence**: medium-high on the mechanism (PR-291 alone), low on the cause.
|
||||
|
||||
### 2026-10-31T09:20Z → 2026-10-31T15:00Z
|
||||
- **Phenomenon of the catalogue**: "The camera moves through a thermal effect". It is labelled even when compensated (D-117).
|
||||
- **Precedents**: CLARIDEN-5, -13, -27, -43 (reviewed): scale against housing temperature, always on drops. This one is a warming, so the direction is opposite.
|
||||
- **Family**: Thermal displacement. The pose follows the housing temperature both ways, and the error_value does not rise during the warming. The return coincides with the Visibility episode CLARIDEN-40: two labels, as on the 22nd.
|
||||
- **Measured**:
|
||||
- Housing temperature, hourly: 07:00 40.05, 09:00 40.43, 11:00 40.63, 13:00 40.78, 14:00 40.30, 15:00 40.20 °C.
|
||||
- Camera scale at 10 min: 0.999857 at 09:40, 0.999881 at 09:50, about 0.99989–0.99991 until 13:50, 0.999878 at 14:10, 0.999847 at 15:00.
|
||||
- Pan, hourly: 0.0042 (09:00), 0.0027 (10:00–13:00), back to 0.0044 at 15:00.
|
||||
- days.py --bounds --smoothing 5: pose_scale 31/10 exceeds 5 noises from 10:50 to 12:50, max +6.0 at 10:50. It is the only day of the range where the pose exceeds 5 noises.
|
||||
- Rigid scale of the targets: 1.000012 → 1.000033 over the same hours.
|
||||
- Corrected curves, 30 min medians:
|
||||
- D-301-C corr_x from about 0.00 to +0.04 from 09:30;
|
||||
- D-304-C corr_y from −0.42 to −0.39 from 09:40;
|
||||
- D-303-C corr_y from −0.088 to −0.07;
|
||||
- D-304-B corr_y from −0.06 to −0.04 from 09:30;
|
||||
- all back by 15:00–15:10.
|
||||
- Start: 09:20, the measurement before the first lasting deviation (09:30). The 09:10 point of D-301-C is isolated and within the noise.
|
||||
- End: 15:00, pose back.
|
||||
- **Images**: 12:00 (whole image) shows a lit object at the far end of the tunnel between the target rows, nothing in front of the targets. 09:00 and 14:00 also exist.
|
||||
- **Confidence**: medium. The co-movement of scale, pan and temperature is clear, but small (the housing temperature varies by less than a degree).
|
||||
|
||||
## 2. What I left without a label
|
||||
- **20→22/10: row B in x drifts slowly** (6 h medians). D-306-B goes from +0.042 to +0.003, about 3.5 noises; P-301-B from −0.02 to −0.04; D-303-B a little; P-299-B goes up and back. In the image (rigid dx), D-306-B barely moves against the other targets (−0.006 → −0.018), so most of it comes from the base. It is small, without dates of its own, and overlaps the reviewed row B labels. If the expert wants it, it would continue the D-306-B horizontal decline already named in CLARIDEN-14.
|
||||
- **20/10 18:40 and 21/10 03:20: row A corr_y minima** (overview window minima of −5.6 to −7 noises). They do not exceed 5 noises against a rolling level of ±6 measurements; they are a slow wander.
|
||||
- **Single-sensor points**: P-298-B corr_y at 31/10 02:40 (+5.3 noises), PR-284 corr_y at 25/10 02:50 (+5.5). They are single points on the two noisiest sensors, with no other sensor and no reference moving.
|
||||
- **ranges --k 4 --instants 4**: every group instant falls inside a labelled moment. The 30/10 18:20 group stays under 4 noises per sensor there but was found by its coherence; it is labelled.
|
||||
- **Weather**: CLARIDEN has no `weather/` folder (a tunnel with no Swiss position), so no weather is available. The instruction in effect (re-read after it changed during the session) reads the weather from `data/<STATION>/weather/`.
|
||||
|
||||
## 3. The documentation
|
||||
- **What helped**:
|
||||
- Rule 2 ("bounds are measurement instants, at the minute") drove 8 of the 9 corrections. The existing labels carried 15-minute-grid minutes (:15, :45) on a 10-minute station.
|
||||
- Rule 5 ("A No data states the metrics and the image") drove the rewrite of CLARIDEN-39.
|
||||
- The `last_sync` metric (one entry per minute) was decisive in showing that the station itself went silent from 17:09 to 17:40.
|
||||
- `overview.py --rigid` separated "the reference PR-291 moves" from "the targets move" on 30/10 18:20.
|
||||
- `days.py --bounds` gave the only thermal day above 5 noises.
|
||||
- **Contradiction to flag**: CLARIDEN-27 and CLARIDEN-43 (reviewed) stay at −4.5 and −3.5 noises on the smoothed scale. Strictly, the rule "no thermal label under 5 noises" would remove them. I kept them because the user validated them and individual points do exceed it. Should the rule be read on smoothed or raw points?
|
||||
- **Precedents**: WYOMING-17 was the right model for the reference-shift jump. The CLARIDEN thermal precedents only cover housing drops; the 31st is the first warming case. Nothing contradicted by the data.
|
||||
- **validate.py** does not check that bounds fall on the station's measurement instants; this is how the :15/:45 bounds passed. A check against the station's instants would catch them.
|
||||
|
||||
## Difficulties
|
||||
- The instructions file and `tools/GUIDE.md` changed on disk during the session. The weather moved from a fetch command to `data/<STATION>/weather/`; CLARIDEN has neither a stations.txt place nor a weather folder, so the outcome is the same.
|
||||
|
||||
## Sources read
|
||||
`instructions/analyst.md` (twice), `tools/GUIDE.md`, `tools/DATA.md`, `labeling/families.md`, `labeling/labeling-rules.md`, `labeling/reading-rules.md`, `labeling/stations.md`, `labeling/auto/CLARIDEN.jsonl` (labels at and around the range: CLARIDEN-1, 5, 11–15, 20–22), `work/existing.jsonl`, `work/spanning.jsonl`, `request.json`, `~/aimsight-data/extraction/stations.txt` (CLARIDEN line, no place). Precedents: `precedents.py` (WYOMING-17, NIEDERHORN-126, CLARIDEN-11, NORDEND-65/89, SNCF01-42). Tools: inventory, overview (common, residuals, rigid at 10 min and 6 h, with --follow), ranges (--rolling 6, --instants 3 and 4), days --bounds --smoothing 5, metrics (3 h and 1 h), summary (10 min, 30 min, 1 h, 6 h), plot. Raw: displacement CSVs (instants of all stations around the gaps), `metrics/` BusVoltage, last_sync, link, GPU on 30/10. Images: 20261030T1800Z, 20261031T1200Z (whole). No quality metrics on this camera (empty columns).
|
||||
@@ -0,0 +1,24 @@
|
||||
{"start": "2026-10-20T04:00Z", "end": "2026-10-25T18:00Z", "family": "Displacement", "description": "Slow drift of targets of row C, then stabilization at a new level: D-301-C rises horizontally from the 20th, D-304-C and D-303-C rise vertically mostly from the 22nd. No camera movement, ordinary recognition error. The rise of D-301-C starts before the work seen around the station on the 22nd (workers and a frame): no link established. The position in the image of D-301-C, D-304-C and D-303-C moves clearly away from that of the other targets, in the direction of their curves. The camera housing temperature stays almost constant over these days: no link with it. Partial return from the 26th to the 29th, labeled separately. Cause not established, in a tunnel under construction: a movement of these targets is not excluded. To be checked against the other measurements of the site; monitor this row.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-20T06:10Z", "end": "2026-10-20T06:30Z", "family": "No data", "description": "One measurement is missing, for all sensors: the curves have a short gap; the station nevertheless synchronizes at that moment, normal voltage. The same moment is also missing at LENZSPITZE, and at no other station: a common cause outside the station is possible, not established. Nothing to do.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-20T20:40Z", "end": "2026-10-20T21:40Z", "family": "No data", "description": "Five measurements are missing within one hour, for all sensors: the curves have a gap. The station is nevertheless running (continuous synchronizations, 21:00 image, normal voltage): the measurement is not made or not recorded. The 21:00 measurement is also missing at NIEDERHORN, and at no other station: a common cause is possible, not established. Nothing to do."}
|
||||
{"start": "2026-10-22T06:30Z", "end": "2026-10-22T08:50Z", "family": "Visibility", "description": "In two phases, from 06:40 to 06:50 then from 07:50 to 08:30, the recognition error of several targets and of the references D-302-C and PR-293 rises, and the corrected curves of the usual group make a bump that comes back: D-301-C horizontally, D-302-B and PR_BG vertically, P-301-B, D-304-B, D-304-C, and at the start D-302_A, P-298-A, D-304-A, D-303-A; between the two, D-302-B and PR_BG move once more. The camera housing temperature drops during these hours. The 08:00 image shows lights at the far end of the tunnel (machine or vehicle), nothing in front of the targets. Diffuse view obstruction of cause not established, the same as in the other episodes at the station. Curves to ignore over the range; the structure does not move."}
|
||||
{"start": "2026-10-22T08:00Z", "end": "2026-10-22T09:20Z", "family": "Thermal displacement", "description": "The camera housing temperature drops clearly on the morning of the 22nd, and the camera scale deviates with it, mostly after the curves have returned from the view obstruction of the same hour, then returns when the housing warms up. The corrected curves do not follow this deviation: the compensation absorbs it. Camera movement by thermal effect, deduced from its pose against the housing temperature; normal, nothing to do.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-22T08:50Z", "end": "2026-10-22T17:00Z", "family": "Displacement", "description": "The low targets of row B rise vertically during the day: D-306-B above all, D-302-B and PR_BG, D-304-B, D-303-B; the recognition error of a few of them rises a little. Workers are visible in the tunnel on the 12:00 image, and a frame appears very close to the camera at the top of the image at 13:00 (it stays there until the end of the batch): work around the station. The position in the image of D-306-B rises a little relative to the other targets, in the direction of its curve. The link between this work and the rise is not established. Evening descent, labeled separately. Cause not established, in a tunnel under construction: a movement of these targets is not excluded. To be checked against the other measurements of the site; monitor this row."}
|
||||
{"start": "2026-10-22T17:00Z", "end": "2026-10-23T10:30Z", "family": "Displacement", "description": "The low targets of row B go back down vertically, all at once on the evening of the 22nd then more slowly on the morning of the 23rd, to below their level from before their rise of the day: D-306-B above all, D-304-B, D-303-B, D-302-B and PR_BG. No camera movement; the frame installed on the 22nd stays at the top of the image (19:00 image), nothing else. The position in the image of D-306-B also goes down relative to the other targets. This is the return of the rise of the day, labeled separately, and it goes beyond it. Cause not established, in a tunnel under construction: a movement of these targets is not excluded. To be checked against the other measurements of the site; monitor this row.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-24T01:00Z", "end": "2026-10-24T05:00Z", "family": "Displacement", "description": "The low targets of row B (D-306-B above all, D-304-B, D-303-B) partly rise again vertically in the night of the 24th, toward their level from before the descent of the evening of the 22nd, without reaching it. No camera movement. Cause not established, in a tunnel under construction: a movement of these targets is not excluded. To be checked against the other measurements of the site; monitor this row.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-24T18:20Z", "end": "2026-10-25T19:10Z", "family": "Displacement", "description": "The left targets of row A (D-302_A, D-303-A, D-304-A, D-301-A, P-299-A) and D-304-B, D-306-B, P-301-B fidget in jolts (around 18:30 and 21:30 on the 24th, 07:00 and 15:30 on the 25th): the vertical rises, the horizontal goes down; the recognition error of these targets and of the reference D-302-C rises during the first jolts, and the references PR-291 and PR-293 move slightly away from the targets in the image. Everything calms down on the evening of the 25th. After the agitation, the horizontal of the A targets stays shifted until the end of the batch. Workers are visible on the image of the 24th at 15:00 and the frame is still at the top of the image. Cause not established: shift to be checked.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-25T18:00Z", "end": "2026-10-29T04:00Z", "family": "Displacement", "description": "After their rise of the 20th to the 25th, D-304-C and D-303-C slowly go back down vertically from the 26th to the 29th, without returning to their level from before the rise, then stabilize. No camera movement, nothing in front of the targets on the images of the 28th at 19:00 and 20:00. Their position in the image also partly returns toward that of the other targets. This is the partial return of the rise of the 20th to the 25th, labeled separately. Cause not established, in a tunnel under construction: a movement of these targets is not excluded. To be checked against the other measurements of the site; monitor this row.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-25T19:10Z", "end": "2026-10-29T04:00Z", "family": "Displacement", "description": "After their rise in jolts of the 24th and 25th, the left targets of row A slowly go back down vertically from the 26th to the 29th, back to about their level from before the jolts: D-304-A, D-303-A, D-302_A and D-301-A above all, P-299-A and P-298-A less; their horizontal stays shifted. Their position in the image comes back with their curves, relative to the other targets; no camera step, ordinary recognition error. Same dates as the partial return of D-304-C and D-303-C, labeled separately. This is the return of the agitation of the 24th and 25th, labeled separately. Cause not established, in a tunnel under construction: a movement of these targets is not excluded. To be checked against the other measurements of the site; monitor this row."}
|
||||
{"start": "2026-10-26T14:30Z", "end": "2026-10-26T15:10Z", "family": "No data", "description": "Three measurements are missing in less than an hour, for all sensors: the curves have a gap; normal voltage around it. The same gap falls at the same moment on the other stations measuring at that time (FLORIDA, JUNGFRAU, LENZSPITZE, NIEDERHORN, NORDEND, SNCF01), and their metrics are also missing at the same minutes: a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station. The hourly metrics of BREITHORN, MICHIGAN and NEBRASKA are also missing at 15:00."}
|
||||
{"start": "2026-10-27T09:00Z", "end": "2026-10-27T09:30Z", "family": "No data", "description": "Two measurements are missing, for all sensors: the curves have a short gap; normal voltage around it. The same gap falls at the same moment on the other stations measuring at that time (FLORIDA, JUNGFRAU, LENZSPITZE, NORDEND): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-27T12:00Z", "end": "2026-10-27T12:20Z", "family": "Target issue", "description": "For the duration of one measurement, the target PR-284 jumps by several pixels horizontally and vertically, then returns: the measured position has left its spot, with a high recognition error but under the threshold, so kept in the curve. Since 24 October around 14:20, the spot of PR-284 is clearly weaker (thumbnails of the 24th at 12:00 and 16:00, of the 27th at 12:00) and its recognition error has stayed high. False point to ignore; look at the state of the target PR-284 if the false points repeat.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-28T19:20Z", "end": "2026-10-28T20:10Z", "family": "Displacement", "description": "On the evening of the 28th, the low targets of row B go down by a step vertically, D-306-B above all, then D-304-B, and stay at this new level until the end of the batch; D-303-B and D-304-B also go down a little horizontally. The position in the image of D-306-B goes down a little relative to the other targets, no camera movement, nothing on the 19:00 and 20:00 images (the frame at the top of the image is still there). Cause not established, in a tunnel under construction: a movement of these targets is not excluded. To be checked against the other measurements of the site; monitor this row.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-29T14:50Z", "end": "2026-10-29T15:10Z", "family": "No data", "description": "One measurement is missing, for all sensors: the curves have a short gap; the station nevertheless synchronizes at that moment, normal voltage. The same gap falls at the same moment on the other stations measuring at that time (LENZSPITZE, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-29T23:50Z", "end": "2026-10-30T00:10Z", "family": "Target issue", "description": "At midnight, D-302-B jumps vertically and a little horizontally and stays at this new level until the end of the batch; PR_BG, on the same prism, jumps in the opposite direction. The raw positions of the two sensors do not move, only their starting position has changed (the relative displacement jumps without any movement in the image): a configuration or processing change of these two sensors, not a movement of the structure. Check their configuration with the operator; do not read this jump as a movement, nor compare their curves before and after."}
|
||||
{"start": "2026-10-30T17:00Z", "end": "2026-10-30T17:50Z", "family": "No data", "description": "Four measurements are missing in less than an hour, for all sensors: the curves have a gap. The station's own record stops too: its minute-by-minute synchronizations are missing over the same half hour, while the 17:00 image exists and the voltage stays normal before and after, so it is not a lack of energy. The other stations measuring at that time (ALASKA, FLORIDA, JUNGFRAU, LENZSPITZE, NADELHORN, NORDEND, SNCF01, WYOMING) have their measurements: the cause is specific to the station, not established. The curves are missing over the range; nothing to do unless it repeats."}
|
||||
{"start": "2026-10-30T18:10Z", "end": "2026-10-30T18:30Z", "family": "Displacement", "description": "For the duration of one measurement, the left targets of row A (D-300-A, D-301-A, D-302_A, D-303-A, D-304-A, P-299-A, P-298-A) and PR-283, PR-284 jump together horizontally, then return at the next measurement; D-303-C and D-304-C move a little the other way. Their raw positions in the image do not move: it is the reference PR-291 that shifts alone horizontally for this measurement, its recognition error rising a little without reaching its threshold, and the compensation passes its shift into the targets. No image at that minute; nothing in front of the scene on the 18:00 and 19:00 images. Cause not established. Not a movement of the structure: point to ignore."}
|
||||
{"start": "2026-10-31T09:20Z", "end": "2026-10-31T15:00Z", "family": "Thermal displacement", "description": "The camera housing temperature rises a little in the late morning of the 31st, and the camera scale rises with it while the pan goes down, until early afternoon; they come back when the housing cools, mostly during the view obstruction of the early afternoon, labeled separately. The compensation absorbs most of it, but a few corrected curves follow a little over these hours and come back with it: D-301-C horizontally, D-304-C, D-303-C and D-304-B vertically. Only a light at the far end of the tunnel on the 12:00 image, nothing in front of the targets. Camera movement by thermal effect, deduced from its pose against the housing temperature; normal, nothing to do."}
|
||||
{"start": "2026-10-31T13:50Z", "end": "2026-10-31T15:10Z", "family": "Visibility", "description": "For one hour, the corrected curves of the usual group make a bump that comes back: D-301-C (horizontal), D-302-B and PR_BG (vertical), D-301-A, D-300-A, D-304-B, D-304-C, D-302_A, and for a moment the reference PR-295; the recognition error of a few sensors rises during the episode. Same signature as the other episodes of view obstruction at the station; cause not established. Curves to ignore over the range."}
|
||||
{"start": "2026-10-31T18:40Z", "end": "2026-10-31T20:00Z", "family": "Visibility", "description": "For the duration of a few measurements, the corrected curves of D-301-C, P-301-B, P-299-A, D-302-B and PR_BG, D-303-B make a bump that comes back, and the reference PR-295, which is seen less well from 18:50, leaves its level; it is rejected at 19:50 (its curve is missing at that measurement), without the targets moving because of it. View obstruction of cause not established; points to ignore."}
|
||||
{"start": "2026-10-31T22:20Z", "end": "2026-11-01T00:00Z", "family": "Visibility", "description": "The reference PR-295 is seen poorly: its spot is weaker (23:00 thumbnail), it is rejected at times and, between two rejections, it is poorly measured; the compensation changes basis, and at 22:50 many targets jump together then return, without any movement of their raw positions. Until 23:50, the curves of D-301-C, P-301-B, D-302-B and PR_BG stay shifted, then briefly cross to the other side, with the recognition error of several targets rising. The camera housing temperature drops clearly at that hour. Cause of the obstruction not established (same signature as the other episodes). The jumps are not a movement: curves to ignore over the range."}
|
||||
{"start": "2026-10-31T23:10Z", "end": "2026-11-01T00:10Z", "family": "Thermal displacement", "description": "The camera housing temperature drops clearly on the evening of the 31st, and the camera scale deviates with it, then partly returns when the housing warms up; the strongest deviation comes when the curves return from the view obstruction of the same hour. The corrected curves do not follow this deviation: the compensation absorbs it. Camera movement by thermal effect, deduced from its pose against the housing temperature; normal, nothing to do.", "review": "2026-11-17"}
|
||||
Binary file not shown.
|
After Width: | Height: | Size: 110 KiB |
@@ -0,0 +1,83 @@
|
||||
# CLARIDEN: verification of the labels, 20 October to 1 November
|
||||
|
||||
You asked me to verify the 21 labels already placed on this range (keep, correct, remove, add).
|
||||
|
||||
## In short
|
||||
|
||||
The 21 labels hold. I removed none and moved no event; 9 needed fixes, mostly start and end times that fell between two measurements. I added 3 events they had missed.
|
||||
|
||||
Outside the labelled moments the curves can be trusted. Inside them, the brief jumps (22nd morning, 30th evening, 31st) are not movements.
|
||||
|
||||
Several target rows move slowly on their own, in the image, then partly come back; the cause is not established. A movement of these targets is not excluded.
|
||||
|
||||
## Verification
|
||||
|
||||
Kept 12, corrected 9, removed 0, added 3. The one long label that crosses the range (CLARIDEN-1, target P-300-B always rejected) holds.
|
||||
|
||||
- CLARIDEN-25: 20:45 → 21:45 becomes 20:40 → 21:40, the measurements on either side of the gap.
|
||||
- CLARIDEN-26: end 08:45 becomes 08:50, the first measurement where the curves are back.
|
||||
- CLARIDEN-28: start 08:45 becomes 08:50, when the row B rise is first seen.
|
||||
- CLARIDEN-33: end 15:15 becomes 15:10, the first measurement after the gap.
|
||||
- CLARIDEN-38: 23:45 → 00:15 becomes 23:50 → 00:10. The jump is exactly at 00:00.
|
||||
- CLARIDEN-39: end 17:45 becomes 17:50. I also rewrote the description: the gap belongs to CLARIDEN alone. All the other stations measured. The station's own minute-by-minute record stops for half an hour, while the 17:00 image exists and the voltage is normal.
|
||||
- CLARIDEN-40: start 13:45 becomes 13:50, the measurement before the first jump at 14:00.
|
||||
- CLARIDEN-41: start 18:45 becomes 18:40, the measurement before the first jump at 18:50.
|
||||
- CLARIDEN-42: start 22:15 becomes 22:20, the measurement before reference PR-295 is first rejected at 22:30.
|
||||
- Added: the slow return of row A in the vertical, 25/10 19:10 → 29/10 04:00.
|
||||
- Added: a one-measurement jump of row A caused by reference PR-291, 30/10 18:10 → 18:30.
|
||||
- Added: the camera moving with the housing warmth on the 31st, 09:20 → 15:00.
|
||||
|
||||
The station measures every 10 minutes. The old bounds at :15 and :45 were not measurement times, which is why most of these fixes are a few minutes.
|
||||
|
||||
## What happened
|
||||
|
||||
**Rows of targets that move slowly, alone** (20th to 29th; likely real, cause unknown). Row C rises from the 20th to the 25th, then partly comes back. Row B rises on the 22nd, drops below its level, and partly recovers. Row B steps down on the 28th. Row A rises in jolts on the 24th and 25th. These were already labelled. What was missing is row A's vertical return: from the 26th to the 29th it comes back to about where it was before the jolts, while its horizontal stays shifted. These targets really move in the image against the others. The camera is not involved and the temperature is flat.
|
||||
|
||||

|
||||
Look at the grey zone: the four row A targets drift back down after the jumps of the 24th and 25th.
|
||||
|
||||
**A reference that moves alone for one measurement** (30th, 18:20; mechanism confirmed, cause unknown). Reference PR-291 shifts slightly for one measurement. The correction carries that shift into the left-hand targets, which jump horizontally and come back at once. The targets themselves do not move in the image. One point to ignore.
|
||||
|
||||
**Camera warmth on the 31st** (likely). From late morning, the housing warms by less than a degree. The camera's apparent zoom and its horizontal angle drift with it, then come back in the early afternoon when it cools. The correction absorbs most of it, but D-301-C, D-304-C, D-303-C and D-304-B follow a little. This is normal.
|
||||
|
||||

|
||||
In the grey zone, D-304-C (bottom) and D-301-C (top) shift slightly, then come back. The sharp dips just after, at 19:00 and around 23:00 are the view-obstruction episodes already labelled.
|
||||
|
||||
## What to do
|
||||
|
||||
Compare rows A, B and C with the site's other measurement systems for 20–29 October.
|
||||
|
||||
## Not established
|
||||
|
||||
- The cause of the slow row movements: the site's other measurements would settle whether the structure moved.
|
||||
- The cause of the PR-291 shift on the 30th: there is no image at that minute.
|
||||
- The cause of the station's half-hour silence on the 30th at 17:00: the station's logs would tell.
|
||||
|
||||
## Labels
|
||||
|
||||
| Start (UTC) | End (UTC) | Family | Targets | In a few words |
|
||||
|---|---|---|---|---|
|
||||
| 2026-10-20 04:00 | 2026-10-25 18:00 | Displacement | D-301-C, D-304-C, D-303-C | row C slow rise (kept) |
|
||||
| 2026-10-20 06:10 | 2026-10-20 06:30 | No data | all | one measurement missing (kept) |
|
||||
| 2026-10-20 20:40 | 2026-10-20 21:40 | No data | all | five missing (bounds fixed) |
|
||||
| 2026-10-22 06:30 | 2026-10-22 08:50 | Visibility | row B, D-301-C, P-301-B | view obstruction (end fixed) |
|
||||
| 2026-10-22 08:00 | 2026-10-22 09:20 | Thermal displacement | camera | housing cold dip (kept) |
|
||||
| 2026-10-22 08:50 | 2026-10-22 17:00 | Displacement | D-306-B, row B | row B rises (start fixed) |
|
||||
| 2026-10-22 17:00 | 2026-10-23 10:30 | Displacement | D-306-B, row B | row B drops back (kept) |
|
||||
| 2026-10-24 01:00 | 2026-10-24 05:00 | Displacement | D-306-B, D-304-B, D-303-B | row B partly rises (kept) |
|
||||
| 2026-10-24 18:20 | 2026-10-25 19:10 | Displacement | row A, D-304-B, D-306-B, P-301-B | jolts (kept) |
|
||||
| 2026-10-25 18:00 | 2026-10-29 04:00 | Displacement | D-304-C, D-303-C | row C partial return (kept) |
|
||||
| 2026-10-25 19:10 | 2026-10-29 04:00 | Displacement | D-304-A, D-303-A, D-302_A, D-301-A | row A vertical return (added) |
|
||||
| 2026-10-26 14:30 | 2026-10-26 15:10 | No data | all | gap common to the stations (end fixed) |
|
||||
| 2026-10-27 09:00 | 2026-10-27 09:30 | No data | all | gap common to the stations (kept) |
|
||||
| 2026-10-27 12:00 | 2026-10-27 12:20 | Target issue | PR-284 | one false point (kept) |
|
||||
| 2026-10-28 19:20 | 2026-10-28 20:10 | Displacement | D-306-B, D-304-B, D-303-B | row B steps down (kept) |
|
||||
| 2026-10-29 14:50 | 2026-10-29 15:10 | No data | all | gap common to the stations (kept) |
|
||||
| 2026-10-29 23:50 | 2026-10-30 00:10 | Target issue | D-302-B, PR_BG | configuration jump (bounds fixed) |
|
||||
| 2026-10-30 17:00 | 2026-10-30 17:50 | No data | all | station silent on its own (rewritten) |
|
||||
| 2026-10-30 18:10 | 2026-10-30 18:30 | Displacement | row A via PR-291 | one-point jump (added) |
|
||||
| 2026-10-31 09:20 | 2026-10-31 15:00 | Thermal displacement | camera; D-301-C, D-304-C | housing warmth (added) |
|
||||
| 2026-10-31 13:50 | 2026-10-31 15:10 | Visibility | D-301-C, D-302-B, PR_BG | view obstruction (start fixed) |
|
||||
| 2026-10-31 18:40 | 2026-10-31 20:00 | Visibility | D-301-C, PR-295 | view obstruction (start fixed) |
|
||||
| 2026-10-31 22:20 | 2026-11-01 00:00 | Visibility | PR-295, many targets | reference seen poorly (start fixed) |
|
||||
| 2026-10-31 23:10 | 2026-11-01 00:10 | Thermal displacement | camera | housing cold dip (kept) |
|
||||
@@ -0,0 +1,6 @@
|
||||
{
|
||||
"station": "CLARIDEN",
|
||||
"start": "2026-10-20T04:00Z",
|
||||
"end": "2026-11-01T00:10Z",
|
||||
"hints": "Verify the existing labels of the range (work/existing.jsonl): keep, correct, remove, add."
|
||||
}
|
||||
Binary file not shown.
|
After Width: | Height: | Size: 229 KiB |
@@ -0,0 +1,31 @@
|
||||
"""Build labels.jsonl from existing.jsonl: keep, correct (bounds/description, review dropped), add."""
|
||||
import json, sys
|
||||
D = sys.argv[1]
|
||||
ex = [json.loads(l) for l in open(f"{D}/work/existing.jsonl")]
|
||||
corr = {
|
||||
"CLARIDEN-25": {"start": "2026-10-20T20:40Z", "end": "2026-10-20T21:40Z"},
|
||||
"CLARIDEN-26": {"end": "2026-10-22T08:50Z"},
|
||||
"CLARIDEN-28": {"start": "2026-10-22T08:50Z"},
|
||||
"CLARIDEN-33": {"end": "2026-10-26T15:10Z"},
|
||||
"CLARIDEN-38": {"start": "2026-10-29T23:50Z", "end": "2026-10-30T00:10Z"},
|
||||
"CLARIDEN-39": {"end": "2026-10-30T17:50Z", "description": "Four measurements are missing in less than an hour, for all sensors: the curves have a gap. The station's own record stops too: its minute-by-minute synchronizations are missing over the same half hour, while the 17:00 image exists and the voltage stays normal before and after, so it is not a lack of energy. The other stations measuring at that time (ALASKA, FLORIDA, JUNGFRAU, LENZSPITZE, NADELHORN, NORDEND, SNCF01, WYOMING) have their measurements: the cause is specific to the station, not established. The curves are missing over the range; nothing to do unless it repeats."},
|
||||
"CLARIDEN-40": {"start": "2026-10-31T13:50Z"},
|
||||
"CLARIDEN-41": {"start": "2026-10-31T18:40Z"},
|
||||
"CLARIDEN-42": {"start": "2026-10-31T22:20Z"},
|
||||
}
|
||||
add = [
|
||||
{"start": "2026-10-25T19:10Z", "end": "2026-10-29T04:00Z", "family": "Displacement", "description": "After their rise in jolts of the 24th and 25th, the left targets of row A slowly go back down vertically from the 26th to the 29th, back to about their level from before the jolts: D-304-A, D-303-A, D-302_A and D-301-A above all, P-299-A and P-298-A less; their horizontal stays shifted. Their position in the image comes back with their curves, relative to the other targets; no camera step, ordinary recognition error. Same dates as the partial return of D-304-C and D-303-C, labeled separately. This is the return of the agitation of the 24th and 25th, labeled separately. Cause not established, in a tunnel under construction: a movement of these targets is not excluded. To be checked against the other measurements of the site; monitor this row."},
|
||||
{"start": "2026-10-30T18:10Z", "end": "2026-10-30T18:30Z", "family": "Displacement", "description": "For the duration of one measurement, the left targets of row A (D-300-A, D-301-A, D-302_A, D-303-A, D-304-A, P-299-A, P-298-A) and PR-283, PR-284 jump together horizontally, then return at the next measurement; D-303-C and D-304-C move a little the other way. Their raw positions in the image do not move: it is the reference PR-291 that shifts alone horizontally for this measurement, its recognition error rising a little without reaching its threshold, and the compensation passes its shift into the targets. No image at that minute; nothing in front of the scene on the 18:00 and 19:00 images. Cause not established. Not a movement of the structure: point to ignore."},
|
||||
{"start": "2026-10-31T09:20Z", "end": "2026-10-31T15:00Z", "family": "Thermal displacement", "description": "The camera housing temperature rises a little in the late morning of the 31st, and the camera scale rises with it while the pan goes down, until early afternoon; they come back when the housing cools, mostly during the view obstruction of the early afternoon, labeled separately. The compensation absorbs most of it, but a few corrected curves follow a little over these hours and come back with it: D-301-C horizontally, D-304-C, D-303-C and D-304-B vertically. Only a light at the far end of the tunnel on the 12:00 image, nothing in front of the targets. Camera movement by thermal effect, deduced from its pose against the housing temperature; normal, nothing to do."},
|
||||
]
|
||||
out = []
|
||||
for l in ex:
|
||||
l = dict(l); lid = l.pop("id")
|
||||
if lid in corr:
|
||||
l.update(corr[lid]); l.pop("review", None)
|
||||
out.append(l)
|
||||
out += add
|
||||
out.sort(key=lambda d: (d["start"], d["end"]))
|
||||
with open(f"{D}/labels.jsonl", "w") as f:
|
||||
for l in out: f.write(json.dumps(l, ensure_ascii=False) + "\n")
|
||||
print(len(out))
|
||||
Reference in new issue
Block a user