# Labels: MICHIGAN, 2026-10-12T16:00Z → 2026-10-23T20:00Z (UTC)
Request: verify the 4 existing labels of the range (`work/existing.jsonl`): keep, correct, remove, add. `DETECTORS: no`.
## Verdict per old id
| Old id | Verdict | Evidence |
|---|---|---|
| MICHIGAN-5 | **corrected** (end 16T16 → 16T12, description) | The corr_x descent is real (median of the targets −0.17 at 15T16, all 14 targets below their level), but (1) the label says "the camera stops nodding forward and straightens a little": the tilt goes down on 13–14 Oct (0.0126 → 0.0097) then rises on 15–16 Oct to 0.0197 at 16T12, its highest of the range so far; the axis that follows the corr_x is the pan (r = −0.96 on 12T16–15T20), not the tilt; (2) it ends at 16T16 and says "then goes up again", while the return is MICHIGAN-7's (from 16T12): the trough is flat from 15T16 to 16T12 (−0.167, −0.157, gap, −0.132), the cut goes in the flat and the two phases touch (labeling-rules §2, §3). The expert sentences are kept. |
| MICHIGAN-6 | kept | No measurement 16T00, 16T04, 16T08 (inventory), no image between 15T20 and 16T12, no metric 15T23 → 16T10; BusVoltage 14.08–14.39 V and battery at 100 % just before and after. `stations.py`: the gap starts at 23:00 on the nine stations measuring then (BREITHORN, CLARIDEN, FLORIDA, JUNGFRAU, MICHIGAN, NEBRASKA, NIEDERHORN, NORDEND, SNCF01); LENZSPITZE starts at 02:10. Everything the label says that I could check holds. |
| MICHIGAN-8 | kept | 17T16 corr_x −0.089 (all targets below), 17T20 corr_y −0.160 (−3.9 noises, all 14 targets beyond 3 noises on the rolling level), 18T04 corr_x +0.118 and corr_y +0.131 (all 14 targets beyond 2 noises), back at 18T08 (corr_y +0.007; corr_x +0.085, in the band of the following days). Gap REF42−REFG43N: y −0.04 px at 17T20, x +0.05 px at 18T04; tilt 0.0228 then 0.0084, rotation swings. Temperature 31.25–32.5 °C without a brief drop at these hours. Thumbnails 17T12, 17T20, 18T04, 18T16: spots of the references and targets intact. NEBRASKA and BREITHORN do not move. |
| MICHIGAN-9 | kept | corr_y −0.201 at 19T04, −0.225 at 19T08 (−5.5 noises, the only day above 5 noises), corr_x −0.039 at 19T08, back at 19T12. Tilt 0.0278 then 0.0337 (max of the range), rotation −0.026, scale 0.99983 (min); gap REF42−REFG43N −0.07 then −0.05 px in y. Housing temperature: 31.0 at 19T04, 32.0 at 05:00, 29.5 from 07:00 to 09:00 (lowest of the range), 30.25 at 11–12:00: the first affected measurement precedes the drop, as the label says. The temperatures of NEBRASKA and BREITHORN drop already at 19T04. Thumbnails 19T04, 19T08: nothing in front. Confidence on the thermal cause medium: the same signature (nod forward, corr_y down) occurs at 17T20 without a drop (MICHIGAN-8). |
Spanning labels (not changed):
- **MICHIGAN-3** (REFPOU22 lost): holds within the range: REFPOU22 rejected at all 65 instants (error_value at its level near 0.99), the compensation on REF42 and REFG43N only (2 retained at every instant).
- **MICHIGAN-7**: wrong within the range on one point: it says "from 16 October … the camera nods forward again"; from 16T12 to 17T12 the tilt goes down (0.0197 → 0.0095, the camera straightens), it rises only from 17T16 (0.0172, then 0.020–0.034). The corr_x rise of 16T12 → 17T08 (−0.132 → +0.012) is the return of the descent of MICHIGAN-5 and follows the pan turning back (−0.0122 → −0.0169), not the tilt. The rest (step of corr_x on 17–18 Oct, slow descent of corr_y, faster tilt from the 17th with the housing temperature dropping) holds.
## 1. My labels
### 2026-10-12T16:00Z → 2026-10-16T12:00Z (MICHIGAN-5, corrected)
- **Phenomenon of the catalogue**: "A compensation on two references" (family of what disturbs them), and "The camera tilts little by little" for the context of the month.
- **Precedents**: MICHIGAN-4, -7 (the neighbouring pieces of the same month, validated), MICHIGAN-12 (validated: "it is the two references that move slightly away from the targets, and the compensation on them alone carries this gap over"), which I followed to state the mechanism.
- **Family**: Displacement: a drift of several days that the housing temperature does not explain alone (r(corr_x, T) = −0.36 on 12T16–15T20), not Thermal displacement; consistent with MICHIGAN-4 and -7.
- **Measured**: median of the targets of corr_x minus their level (`scripts/table.py`, `work/table.txt`): 12T16 −0.001, 13T16 −0.139, 14T00 −0.030, 14T16 −0.129, 15T00 −0.033, 15T16 −0.167, 15T20 −0.157, 16T12 −0.132, 16T16 −0.071; lower at 12:00–20:00 every day, higher at 00:00. corr_y: +0.03 to +0.09 until 15T08, −0.073 at 15T12, −0.023, −0.035, −0.098 at 16T12, −0.011 at 16T16. Gap REF42−REFG43N in raw x: +0.03 px on 12–14 Oct, 0.00 from 15T08 (r(corr_x, gap x) = +0.85). Pose: pan −0.0174 → −0.0089 at 15T16 (r(corr_x, pan) = −0.96), tilt 0.0126 → 0.0097 (13T08) → 0.0176 (15T12) → 0.0197 (16T12). `overview.py --rigid` base 12T16: targets' residual median ≤ 0.015 px, max ≤ 0.037 px; residuals of the references ≤ 0.06 px. Housing temperature 31.75–34.5 °C, peaks in the afternoons (13T12 34.5, 14T16 34.0, 15T16 34.5). Days: corr_x never above 5 noises of the night level (−2.0 at most, `days.py --bounds`). Neighbours: the tilts of NEBRASKA (0.0275 → 0.0239) and BREITHORN (0.0200 → 0.0172) go down over 13–16 Oct; MICHIGAN's rises on 15–16.
- **Images**: thumbnails of REF42, REFG43N, COLH18S''', POUH19N', COLH21 at 12T16, 13T16, 14T00, 15T16, 15T20, 16T12, 16T16 (`--fixed`): spots intact, nothing in front.
- **Confidence**: high on the curves and the mechanism; the cause of the change of the gap between the two references is not established.
### 2026-10-15T20:00Z → 2026-10-16T12:00Z (MICHIGAN-6, kept)
- **Phenomenon of the catalogue**: "A gap common to several stations".
- **Precedents**: none needed beyond the label itself.
- **Family**: No data: no measurement for any sensor.
- **Measured**: see the verdict table.
- **Images**: none in the gap (no file between 15T20 and 16T12).
- **Confidence**: high.
### 2026-10-17T12:00Z → 2026-10-18T08:00Z (MICHIGAN-8, kept)
- **Phenomenon of the catalogue**: "A compensation on two references" / "The base changes without a reference lost".
- **Precedents**: MICHIGAN-12 (same signature on 27 Oct, validated); JUNGFRAU-110, FLORIDA-72 (one-measurement common jumps through the base, Displacement).
- **Family**: Displacement: no temperature drop at these hours, no visible cause.
- **Measured**: see the verdict table; rolling level ±6 measurements, `ranges.py --instants`: 17T20 all 14 targets corr_y −4 to −5 noises; 18T04 all targets corr_x +2 to +3, corr_y +2 to +4.
- **Images**: thumbnails 17T12, 17T20, 18T04, 18T16; whole image 17T20: indoor scene, dark, all spots present.
- **Confidence**: high on the bounds; cause not established.
### 2026-10-19T00:00Z → 2026-10-19T12:00Z (MICHIGAN-9, kept)
- **Phenomenon of the catalogue**: "The camera drifts away when the temperature of its housing drops, without a daily cycle".
- **Precedents**: MICHIGAN-2, -10, -11, -13 (validated, same signature with a brief drop of the housing temperature).
- **Family**: Thermal displacement, as the validated precedents of this station; see the reservation above.
- **Measured**: see the verdict table.
- **Images**: thumbnails 19T04, 19T08: nothing in front.
- **Confidence**: medium on the cause (the plunge starts before the drop recorded at the camera; the neighbours cool at 19T04), high on the bounds.
## 2. What I left without a label
The corrected curves of all the targets are agitated together all through the range, through the compensation on two references (MICHIGAN-3): the raw positions are given to the hundredth of a pixel and a change of one or a few hundredths of the gap between REF42 and REFG43N becomes about a tenth of a pixel on all the targets (r(corr_y, gap y) = +0.8, r(corr_x, gap x) = +0.8 on each part of the range). Left without a label, because they stay under the threshold that the labelled moments pass (median of the targets under 3.5 noises of its level; `days.py`: never above 5 noises outside 19 Oct; `ranges.py --rolling 6 --k 3 --instants 6`: only 17T20, 19T04, 19T08 in the range):
- the **corr_x of all the targets higher at the 00:00 measurement** from 19 to 23 Oct (+0.12 to +0.15, the other hours +0.02 to +0.08), following the pan; the lowest points 20T04 (−0.043, all targets −2 to −4 noises against the rolling level, pan jumping to −0.0134), 21T08 (−0.033, −2 to −3 noises), 22T16, 23T20. 20T04 is the closest to a label: about as large as the 18T04 part of MICHIGAN-8, but alone in x, and as deep as 21T08 against the median level of these days (−2.2 and −2.0 noises): I treat both as the troughs of this agitation, not as events;
- **small dips of the corr_y of all the targets with a nod of the camera** (tilt up, rotation down), about half of those of MICHIGAN-8 and -9: 16T12 (−0.098, at the resumption), 17T04 (−0.082), 19T16 (−0.101), 21T00 (−0.083), 21T08 (−0.073), 23T08 to 23T20 (−0.094, −0.082, −0.047, −0.078, tilt 0.019 → 0.028 at 23T08 and staying there): the latter precede MICHIGAN-10 (24 Oct, outside the range), whose camera nod starts at 23T08 already;
- the daily wave of the corr_x on 13–15 Oct, described in MICHIGAN-5 (under 5 noises, no separate thermal label: labeling-rules §1).
## 3. The documentation
- `families.md` ("A compensation on two references") and `reading-rules.md` (§5: neighbouring cameras read together; at least three references) framed everything; `stations.md` (MICHIGAN: two references since 09.10, a measurement every four hours, indoors) too.
- What was missing: nothing tells how big a common deviation must be to be labelled on a station compensated on two references, where all the targets always move together; the "5 noises" rule exists only for the thermal cycle. I took the moments already validated as the threshold (about 4 noises of the median of the targets).
- What misled: the validated labels MICHIGAN-5 and -7 tell the camera's tilt from the narrative of the three cameras of the building ("stop and slight backward movement from 13 to 16, resumption from the 17th"); on MICHIGAN itself the tilt rises on 15–16 Oct and goes down on 16–17 Oct, and the corr_x follows the pan. A description of a camera axis is to be read on the station's own pose (labeling-rules §5, "checked axis by axis").
- The raw positions are rounded to the hundredth of a pixel: the gap between the two references moves by steps of that size, which `overview.py --rigid` shows only as residuals of a few hundredths; computing the gap REF42 − REFG43N directly (`scripts/table.py`) made the mechanism plain.
- No weather: `data/MICHIGAN/weather/` does not exist (station without a Swiss position, indoors).
## Difficulties
- `plot.py --zone` takes one range per flag (`--zone A/B --zone C/D`), not several after one flag.
## Sources read
- `agents/agents/analyst.md`, `instructions/analyst.md`, `work/prompt.txt`, `work/existing.jsonl`, `work/spanning.jsonl`
- `tools/GUIDE.md`, `tools/DATA.md`, `labeling/families.md`, `labeling/labeling-rules.md`, `labeling/reading-rules.md`, `labeling/stations.md`
- `labeling/auto/MICHIGAN.jsonl` (MICHIGAN-2, -4, -10, -11, -12, -13 for the edges and the precedents)
- precedents: `precedents.py` (JUNGFRAU-110, -112, FLORIDA-72, NORDEND-80, WYOMING-17, NEBRASKA-10, MICHIGAN-2, -11, -13, -15)
- tools: `inventory.py`, `overview.py --rigid` (`work/overview.txt`), `metrics.py` (`work/metrics.txt`), `ranges.py --rolling` (`work/ranges_rolling.txt`), `days.py --bounds` (`work/days.txt`), `stations.py` (all stations at the gap; MICHIGAN, NEBRASKA, BREITHORN over the range), `thumbnails.py`, `plot.py`; whole image 2026-10-17T20:00Z
- my script `scripts/table.py` (per instant: medians of the targets, gap REF42 − REFG43N, pose, hourly temperature; `work/table.txt`)
Binary file not shown.

After

Width:  |  Height:  |  Size: 165 KiB

@@ -0,0 +1,4 @@
{"start": "2026-10-12T16:00Z", "end": "2026-10-16T12:00Z", "family": "Displacement", "description": "From the evening of 12 October to 15 October, the corr_x of all the targets goes down together, lower every afternoon and partly back up at every midnight, lowest on the afternoon and evening of 15 October; after the gap of the night of 15 to 16 October (labelled apart), it is still at its lowest at the resumption at noon on 16 October, then comes back, a return labelled apart with the movement of the rest of the month. The corr_y hardly moves until 15 October, then goes down a little on 15 October at noon and stays slightly low until the resumption. In the image, the targets do not move relative to each other and hardly relative to the two remaining references: the gap between REF42 and REFG43N changes only very slightly, and the compensation on these two references alone, since the loss of REFPOU22 (labelled apart), carries it over, amplified, to all the targets. The camera pan computed on them turns little by little, exactly opposite to the corr_x; the tilt goes down a little on 13 and 14 October, then rises again on 15 and 16 October: the camera does not straighten over the whole range. The camera housing temperature varies little; it is a little higher in the afternoons, when the corr_x is lowest, but does not explain the descent alone: link not established. Deduced from the curves and the camera pose; nothing in front of the targets or the references on the thumbnails of 13, 14, 15 and 16 October. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of BREITHORN and NEBRASKA stop and move back on the same days, when the housing temperature stops dropping, while the tilt of MICHIGAN rises again on 15 and 16 October; link not established. For the customer: the targets do not move relative to each other, this is not a movement of the structure; the camera is to be monitored, and restoring a third reference will make the curves reliable again."}
{"start": "2026-10-15T20:00Z", "end": "2026-10-16T12:00Z", "family": "No data", "description": "No measurement for any sensor in the night of 15 to 16 October: three measurements are missing, all the curves are cut, then everything resumes at the same level. The station metrics are also missing over these hours (temperatures, voltage, synchronization); the voltage is normal just before and just after, the battery full: no sign of a power cut. The same gap affects the two other stations of the building (BREITHORN, NEBRASKA, in the same building according to the expert), but also all the other stations. The gap starts at the same time, around 23:00, on the nine stations that were measuring then (LENZSPITZE only has its first measurements in the middle of that night, WILDSTRUBEL is already stopped), and their metrics stop at the same time on most of them; measurements and metrics resume at different times depending on the station, most of them in late morning. JUNGFRAU, whose metrics continue, accumulates unsent entries all night, sent in late morning, and yet its measurements for the night are missing from the data: a common cause outside the stations (transmission or reception of the data), not a shutdown of the stations; it is not established. The cause is therefore not specific to the building. The curves are missing over the range; nothing to do on the station if it does not repeat.", "review": "2026-11-17"}
{"start": "2026-10-17T12:00Z", "end": "2026-10-18T08:00Z", "family": "Displacement", "description": "All the targets become agitated together for three measurements: the corr_x goes down at 16:00 on 17 October, the corr_y plunges at 20:00, then corr_x and corr_y rise above their level on 18 October at 04:00, and everything returns. The camera pose computed on REF42 and REFG43N swings back and forth (tilt, rotation) without the raw positions of the targets moving clearly, and the gap between the two references changes a little: it is the two-reference compensation that carries this gap over to all the targets. The temperatures then drop in steps, but without a brief variation at the time of these deviations. Cause not established, nothing on the images. For the customer: this is not a movement of the structure, the points of this range are to be ignored.", "review": "2026-11-17"}
{"start": "2026-10-19T00:00Z", "end": "2026-10-19T12:00Z", "family": "Thermal displacement", "description": "On 19 October in the morning, the corr_y of all the targets plunges together for two measurements, the corr_x too at the second, then everything returns at noon. The camera housing temperature makes a brief drop at the same moment, at the end of the night, and the camera moves: it nods forward, rotates, its scale drops, the raw positions of all the targets and of the two references slide almost together; the targets do not move relative to each other. The compensation on two references only, REF42 and REFG43N, carries their small gap relative to the targets over to all the targets. The first affected measurement slightly precedes the temperature drop. Cause deduced from the curves and the camera housing temperature; nothing in front of the targets on the 08:00 image. For the customer: this is not a movement of the structure, nothing to do.", "review": "2026-11-17"}
@@ -0,0 +1,50 @@
# MICHIGAN: check of the labels of 12 to 23 October
You asked whether the four labels already placed on MICHIGAN between 12 October 16:00 and 23 October 20:00 (UTC) are right.
## In short
Three labels hold as they are; one (12 to 16 October) is corrected: its end and its account of what the camera does. Nothing is added or removed.
Over the whole range the corrected curves are only roughly reliable: the station compensates its camera with two references only, and every tiny change between them moves all the targets together.
No real movement of the structure is seen: the targets never move relative to each other.
## Verification
Kept 3, corrected 1, removed 0, added 0.
- **MICHIGAN-5** (12 to 16 October, Displacement): corrected. Its end moves from 16 October 16:00 to 16 October 12:00, so that it touches the next label (the climb back up after the night gap belongs to MICHIGAN-7, not to both). Its text said the camera "straightens a little"; on this station the camera leans back a little on 13 and 14 October but leans forward again on 15 and 16, and the curve in x follows the sideways turn of the camera (the pan), not its lean. The expert's remarks on the building are kept. It loses its validation.
- **MICHIGAN-6** (night of 15 to 16 October, No data): kept.
- **MICHIGAN-8** (17 to 18 October, Displacement): kept.
- **MICHIGAN-9** (19 October morning, Thermal displacement): kept. The first affected measurement (04:00) comes before the drop of the camera temperature (07:00 to 09:00), as the label already says; the same kind of dip on 17 October 20:00 happens without any drop, so the thermal cause stays likely rather than certain.
- Long label **MICHIGAN-7** (16 October to the end of the month), not changed: from 16 October 12:00 to 17 October 12:00 it is wrong on the camera. It says the camera leans forward again from 16 October; in fact the camera leans back until 17 October noon and only leans forward again from 17 October 16:00. The rise of the curve in x on 16 and 17 October is the return of the dip of MICHIGAN-5.
- Long label **MICHIGAN-3** (reference REFPOU22 lost): correct within the range.
## What happened
**Slow wander of the curves in x (12 to 23 October).** The corrected curve in x of all the targets goes down until 15 October, then comes back up and stays higher from 18 October. It is not the targets that move: the two remaining references, REF42 and REFG43N, change their distance by a few hundredths of a pixel, and the compensation, which rests on them alone, turns that into about a tenth of a pixel on every target. Confirmed from the raw positions; why the distance between the two references changes is unknown.
**Brief swings of all the targets (17–18 October, 19 October).** On 17 October at 20:00 the curve in y of all the targets drops, on 18 October at 04:00 both curves jump up, and on 19 October from 04:00 to 08:00 the curve in y drops the most of the range; each time the camera leans forward and turns a little, and the curves come back at the next measurement or the one after. The images show nothing in front of the targets. The 19 October dip comes with a short cooling of the camera (likely thermal); the 17–18 October one has no known cause.
**Missing night (15 to 16 October).** Three measurements are missing, on all the stations measuring then: a cause outside the station, not established.
![Corrected curves of four targets](curves.png)
Look at how all the targets move together, in both curves; the grey bands are the missing night and the two brief swings.
## What to do
Restore a third reference (REFPOU22) on site: until then the curves of MICHIGAN keep a common wobble of about a tenth of a pixel.
## Not established
- Why the distance between the two remaining references changes: a check of their mounting on site, or the third reference back, would tell.
- Smaller swings of the same kind (20 October 04:00, 21 October 08:00, 23 October from 08:00) were left without a label as part of this common wobble; the one from 23 October 08:00 leads into the dip of 24 October, labelled separately.
## Labels
| Start (UTC) | End (UTC) | Family | Targets | In a few words |
|---|---|---|---|---|
| 2026-10-12 16:00 | 2026-10-16 12:00 | Displacement | all | curve in x drifts down through the two-reference compensation (corrected) |
| 2026-10-15 20:00 | 2026-10-16 12:00 | No data | all | three measurements missing on every station |
| 2026-10-17 12:00 | 2026-10-18 08:00 | Displacement | all | brief swings of all the targets, cause unknown |
| 2026-10-19 00:00 | 2026-10-19 12:00 | Thermal displacement | all | dip in y with a short cooling of the camera |
@@ -0,0 +1,6 @@
{
"station": "MICHIGAN",
"start": "2026-10-12T16:00Z",
"end": "2026-10-23T20:00Z",
"hints": "Verify the existing labels of the range (work/existing.jsonl): keep, correct, remove, add."
}
@@ -0,0 +1,34 @@
"""Per measurement instant: median corr_x/corr_y of the targets (minus each target's level over the window),
the spread of the targets, the gap REF42 - REFG43N in raw x, y (minus its level), the pose, the temperature
of the hour (median of sensor_*_deg_c), and of the previous/next hours. Usage: table.py START END"""
import sys, statistics as st
sys.path.insert(0, "tools/scripts")
import data
start, end = data.parse_time(sys.argv[1]), data.parse_time(sys.argv[2])
F = "data/MICHIGAN"
m = data.load(F)
cam = {p["t"].replace(second=0, microsecond=0): p for p in data.load_camera(F)}
temp = {t: v for t, v in data.load_temperature(F)}
tg = [s for s in m if not data.is_reference(m[s])]
W = {s: [x for x in data.filter_window(m[s], start, end)] for s in m}
lvl = {s: (st.median([x["corr_x"] for x in W[s] if x["corr_x"] is not None]),
st.median([x["corr_y"] for x in W[s] if x["corr_y"] is not None])) for s in tg}
times = [x["t"] for x in W["REF42"]]
r1 = {x["t"]: x for x in W["REF42"]}; r2 = {x["t"]: x for x in W["REFG43N"]}
gx = {t: r1[t]["x"] - r2[t]["x"] for t in times}; gy = {t: r1[t]["y"] - r2[t]["y"] for t in times}
gxl, gyl = st.median(gx.values()), st.median(gy.values())
print("time cx_med cx_min cx_max | cy_med cy_min cy_max | gapx gapy | ev42 evG43 | pan tilt rot scale | T-1h T T+1h")
from datetime import timedelta
for t in times:
by = {x["t"]: x for s in tg for x in W[s] if x["t"] == t}
cx = [x["corr_x"] - lvl[s][0] for s in tg for x in W[s] if x["t"] == t and x["corr_x"] is not None]
cy = [x["corr_y"] - lvl[s][1] for s in tg for x in W[s] if x["t"] == t and x["corr_y"] is not None]
k = t.replace(second=0, microsecond=0); p = cam.get(k, {})
h = k.replace(minute=0)
T = [temp.get(h + timedelta(hours=d)) for d in (-1, 0, 1)]
f = lambda v, n=6, d=3: (f"{v:{n}.{d}f}" if v is not None else " " * (n - 1) + "-")
print(f"{data.iso(t)} {f(st.median(cx))} {f(min(cx))} {f(max(cx))} | {f(st.median(cy))} {f(min(cy))} {f(max(cy))} | "
f"{f(gx[t]-gxl,6,3)} {f(gy[t]-gyl,6,3)} | {f(r1[t]['error_value'],5,3)} {f(r2[t]['error_value'],5,3)} | "
f"{f(p.get('pan'),8,4)} {f(p.get('tilt'),7,4)} {f(p.get('rotation'),8,4)} {f(p.get('scale'),8,5)} | "
+ " ".join(f(v, 5, 1) for v in T))