auto: the reviews of 2026-11-18 on CLARIDEN, FLORIDA, MICHIGAN, NEBRASKA, NORDEND, WILDSTRUBEL, and their analysis copies

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
maximeandClaude Opus 5.5 committed 2026-11-18 17:47:59 +01:00
1 parent 58b630f2d5
commit 3b80b7c963
14 files changed
+140 -140

No files matched your search

+9 -9
View File
@@ -1,12 +1,3 @@
{"id": "CLARIDEN-2", "start": "2026-10-01T06:15Z", "end": "2026-10-01T08:45Z", "family": "Visibility", "description": "The recognition error of most targets rises together, first a little, then clearly around 07:50-08:00, and comes back down; at the same time the corrected curves of several targets make a bump that comes back: D-301-C horizontally, D-302-B and PR_BG (same prism) vertically, D-306-B, D-303-B, P-301-B, then around 08:00 D-301-A, D-302_A, D-304-A. The scene deforms a little (scale and rotation of the targets, references PR-291 and PR-293 moving away from the targets), without camera movement. Nothing on the 07:00 and 08:00 images, which are dark as always. Diffuse obstruction of the view in the tunnel, cause not established (the tunnel air?); same signature as the episodes of 2, 6, 18, 22 and 31 October. The structure does not move: do not trust the curves over the range.", "review": "2026-11-17", "analysis": "CLARIDEN_2026-10-01T0000_2026-10-11T0000"}
{"id": "CLARIDEN-45", "start": "2026-10-02T21:30Z", "end": "2026-10-02T23:00Z", "family": "Visibility", "description": "The recognition error of most targets rises together for one hour, and the corrected curves of D-304-B (vertical) above all, of D-301-C (horizontal), D-302-B and PR_BG, P-301-B, D-304-C make a bump that comes back; D-304-B is still shifted at the last measurement, before 23:00. The camera housing temperature drops clearly at the same time. Nothing visible on the 22:00 image. Diffuse obstruction of the view, cause not established, perhaps a change in the tunnel air. The structure does not move: curves to ignore over the range.", "review": "2026-11-18", "analysis": "CLARIDEN_2026-10-01T0000_2026-10-11T0000"}
{"id": "CLARIDEN-6", "start": "2026-10-03T07:40Z", "end": "2026-10-03T08:00Z", "family": "No data", "description": "One measurement is missing, for all sensors: the curves have a short gap. Cause not established.", "review": "2026-11-17", "analysis": "CLARIDEN_2026-10-01T0000_2026-10-11T0000"}
{"id": "CLARIDEN-7", "start": "2026-10-03T17:30Z", "end": "2026-10-03T17:45Z", "family": "Visibility", "description": "Last measurement before the gap of 3 October: the same one-measurement bump on D-301-C, D-302-B and PR_BG, D-304-B, D-304-C, P-301-B, with the recognition error of many targets rising. Same signature as the episodes of view obstruction at the station; cause not established, perhaps linked to the station shutdown that follows. Point to ignore.", "review": "2026-11-17", "analysis": "CLARIDEN_2026-10-01T0000_2026-10-11T0000"}
{"id": "CLARIDEN-8", "start": "2026-10-03T17:45Z", "end": "2026-10-05T10:30Z", "family": "No data", "description": "No measurement or image for almost two days, for all sensors, and the station metrics are missing too: the entire station stopped. Voltage and battery normal before and after the gap, so not the signature of a power cut; on resumption, the camera has moved and a blurred object is very close to the lens (10:30 image), which suggests an intervention on the station. Cause not established: the curves are missing over the range.", "review": "2026-11-17", "analysis": "CLARIDEN_2026-10-01T0000_2026-10-11T0000"}
{"id": "CLARIDEN-9", "start": "2026-10-03T17:45Z", "end": "2026-10-05T10:45Z", "family": "Displacement", "description": "After the gap of 3 to 5 October, many targets resume at a different level, and do not return to the previous one until the end of the batch: D-304-C and D-303-C above all, in both directions, then D-302_A and D-301-A, P-299-B, D-300-C, D-303-B and D-304-B horizontally, D-301-C vertically; D-306-B, for its part, returns to its level from before its descent of the evening of the 1st. The raw positions of D-304-C and D-303-C have moved in the image relative to the other targets, the recognition error of several targets (D-302-C, D-301-C, D-303-C, D-304-C, D-301-A, D-306-B) also changes level, and the camera scale is no longer the same: the appearance of these targets and the camera pose changed during the shutdown. On resumption, a blurred object is very close to the lens (10:30 image). Cause not established: intervention or changed setting during the shutdown, or real movement; to be checked before trusting these new levels.", "review": "2026-11-17", "analysis": "CLARIDEN_2026-10-01T0000_2026-10-11T0000"}
{"id": "CLARIDEN-10", "start": "2026-10-05T10:30Z", "end": "2026-10-05T11:20Z", "family": "Obstruction", "description": "First measurement after the gap: the whole scene, references included, is shifted by several pixels in the image and the camera is tilted, then it returns within twenty minutes; the compensation absorbs it poorly for the duration of one measurement, and the corrected curves of many targets jump then return (D-303-C, D-302-B and PR_BG, D-306-B, D-304-B, P-299-C above all; D-303-B stays slightly shifted until 11:10). D-304-C is rejected. The 10:30 image shows a large blurred object very close to the lens, on the right, which hides D-304-C, and a worker in reflective clothing in the tunnel, at the top left: work is going on around the camera. Points to ignore; the structure does not move.", "review": "2026-11-17", "analysis": "CLARIDEN_2026-10-01T0000_2026-10-11T0000"}
{"id": "CLARIDEN-11", "start": "2026-10-05T12:10Z", "end": "2026-10-05T12:30Z", "family": "Obstruction", "description": "For the duration of one measurement, the whole right-hand row C (D-300-C, D-301-C, D-303-C, D-304-C, P-298-C, P-299-C) and the reference D-302-C are rejected, their recognition error almost at 1; the compensation runs without D-302-C and the targets that stayed under the threshold jump then return at the next measurement (D-306-B above all vertically, D-303-B, D-304-B, P-299-B, P-301-B, D-302-B and PR_BG). No image at 12:20: the cause is not seen, but the signature is that of something passing in front of the right-hand part of the scene. Point to ignore.", "review": "2026-11-17", "analysis": "CLARIDEN_2026-10-01T0000_2026-10-11T0000"}
{"id": "CLARIDEN-12", "start": "2026-10-06T18:00Z", "end": "2026-10-06T22:10Z", "family": "Visibility", "description": "For four hours, the corrected curves of the same group of targets take a step that starts and ends sharply: D-301-C horizontally above all, D-302-B and PR_BG (same prism) horizontally then vertically, D-304-B vertically, and at times P-301-B, D-303-B, D-302_A, D-301-A, D-304-C. The recognition error of the references PR-293, PR-295, PR-296 and of a few targets rises a little; the references move away from each other in the image. The camera housing temperature drops clearly over these hours. Nothing visible on the 20:00 image. View obstruction of cause not established, probably the tunnel air (colder); the curves and the recognition error return at 22:00, before the camera scale. The structure does not move: curves to ignore over the range.", "analysis": "CLARIDEN_2026-10-01T0000_2026-10-11T0000"}
{"id": "CLARIDEN-1", "start": "2026-10-01T00:00Z", "end": "2026-11-01T00:00Z", "family": "Target issue", "description": "The target P-300-B is rejected at every measurement of the batch: its recognition error stays almost at 1, its corrected curve is missing over the whole month. This has lasted since 29 September in the late afternoon, the time when the recognition error of other targets, including its neighbor P-301-B, also changes level all at once: a station setting changed that day. On the thumbnails (the 1st, the 15th and the 31st), the prism spot is sharp and bright, but next to the position where the system looks for it: the target seems badly configured or badly positioned, not hidden. Curve to ignore; correct the position of the target in the configuration or check the prism.", "review": "2026-11-17", "analysis": "CLARIDEN_2026-10-01T0000_2026-11-01T0000"}
{"id": "CLARIDEN-74", "start": "2026-10-06T22:00Z", "end": "2026-10-11T06:00Z", "family": "Displacement", "description": "Slow drift of several targets over four days, made of small steps, then stabilization: D-303-B rises vertically, D-303-C and D-304-C rise vertically, D-301-C rises horizontally, D-306-B goes down horizontally. The camera moves: its tilt drifts slowly over the same days, with a small step on the 8th, and these targets follow it closely in the directions of their curves; the compensation does not absorb this tilt equally on every target. Ordinary recognition error, nothing on the images. The camera housing temperature stays almost constant over these days: no link with it. Afterwards D-301-C comes back down a little over the following days, too little to be labeled, and D-303-B stays at its new level. Deduced from the curves and the camera pose: mostly a remainder of the camera tilt, not established as a movement of the structure; the camera is to be monitored, and these targets checked against the other measurements of the site.", "review": "2026-11-18", "analysis": "CLARIDEN_2026-10-01T0000_2026-11-01T0000"}
{"id": "CLARIDEN-52", "start": "2026-10-15T22:50Z", "end": "2026-10-16T10:30Z", "family": "No data", "description": "No measurement or image for almost twelve hours, on the night of 15 to 16, and no station metric. The gap starts at the same time, around 23:00, on the nine stations that were measuring then (LENZSPITZE only has its first measurements in the middle of that night, WILDSTRUBEL is already stopped), and their metrics stop at the same time on most of them; measurements and metrics resume at different times depending on the station, most of them in late morning. JUNGFRAU, whose metrics continue, accumulates unsent entries all night, sent in late morning, and yet its measurements for the night are missing from the data: a common cause outside the stations (transmission or reception of the data), not a shutdown of the stations; it is not established. In addition, at CLARIDEN, the station restarts on its battery: the voltage stays well below its usual level, without charge, until early afternoon, then charging resumes; its power supply was also missing that night. The curves are missing over the range; check the site power supply if it repeats.", "review": "2026-11-18", "analysis": "CLARIDEN_2026-10-11T0000_2026-10-20T0400"}
@@ -29,3 +20,12 @@
{"id": "CLARIDEN-69", "start": "2026-10-31T13:50Z", "end": "2026-10-31T15:10Z", "family": "Visibility", "description": "For one hour, the corrected curves of the usual group make a bump that comes back: D-301-C (horizontal), D-302-B and PR_BG (vertical), D-301-A, D-300-A, D-304-B, D-304-C, D-302_A, and for a moment the reference PR-295; the recognition error of a few sensors rises during the episode. Same signature as the other episodes of view obstruction at the station; cause not established. Curves to ignore over the range.", "review": "2026-11-18", "analysis": "CLARIDEN_2026-10-20T0400_2026-11-01T0010"}
{"id": "CLARIDEN-70", "start": "2026-10-31T18:40Z", "end": "2026-10-31T20:00Z", "family": "Visibility", "description": "For the duration of a few measurements, the corrected curves of D-301-C, P-301-B, P-299-A, D-302-B and PR_BG, D-303-B make a bump that comes back, and the reference PR-295, which is seen less well from 18:50, leaves its level; it is rejected at 19:50 (its curve is missing at that measurement), without the targets moving because of it. View obstruction of cause not established; points to ignore.", "review": "2026-11-18", "analysis": "CLARIDEN_2026-10-20T0400_2026-11-01T0010"}
{"id": "CLARIDEN-71", "start": "2026-10-31T22:20Z", "end": "2026-11-01T00:00Z", "family": "Visibility", "description": "The reference PR-295 is seen poorly: its spot is weaker (23:00 thumbnail), it is rejected at times and, between two rejections, it is poorly measured; the compensation changes basis, and at 22:50 many targets jump together then return, without any movement of their raw positions. Until 23:50, the curves of D-301-C, P-301-B, D-302-B and PR_BG stay shifted, then briefly cross to the other side, with the recognition error of several targets rising. The camera housing temperature drops clearly at that hour. Cause of the obstruction not established (same signature as the other episodes). The jumps are not a movement: curves to ignore over the range.", "review": "2026-11-18", "analysis": "CLARIDEN_2026-10-20T0400_2026-11-01T0010"}
{"id": "CLARIDEN-2", "start": "2026-10-01T06:15Z", "end": "2026-10-01T08:45Z", "family": "Visibility", "description": "The recognition error of most targets rises together, first a little, then clearly around 07:50-08:00, and comes back down; at the same time the corrected curves of several targets make a bump that comes back: D-301-C horizontally, D-302-B and PR_BG (same prism) vertically, D-306-B, D-303-B, P-301-B, then around 08:00 D-301-A, D-302_A, D-304-A. The scene deforms a little (scale and rotation of the targets, references PR-291 and PR-293 moving away from the targets), without camera movement. Nothing on the 07:00 and 08:00 images, which are dark as always. Diffuse obstruction of the view in the tunnel, cause not established (the tunnel air?); same signature as the episodes of 2, 6, 18, 22 and 31 October. The structure does not move: do not trust the curves over the range.", "review": "2026-11-17", "analysis": "CLARIDEN_2026-10-01T0000_2026-10-11T0000"}
{"id": "CLARIDEN-45", "start": "2026-10-02T21:30Z", "end": "2026-10-02T23:00Z", "family": "Visibility", "description": "The recognition error of most targets rises together for one hour, and the corrected curves of D-304-B (vertical) above all, of D-301-C (horizontal), D-302-B and PR_BG, P-301-B, D-304-C make a bump that comes back; D-304-B is still shifted at the last measurement, before 23:00. The camera housing temperature drops clearly at the same time. Nothing visible on the 22:00 image. Diffuse obstruction of the view, cause not established, perhaps a change in the tunnel air. The structure does not move: curves to ignore over the range.", "review": "2026-11-18", "analysis": "CLARIDEN_2026-10-01T0000_2026-10-11T0000"}
{"id": "CLARIDEN-6", "start": "2026-10-03T07:40Z", "end": "2026-10-03T08:00Z", "family": "No data", "description": "One measurement is missing, for all sensors: the curves have a short gap. Cause not established.", "review": "2026-11-17", "analysis": "CLARIDEN_2026-10-01T0000_2026-10-11T0000"}
{"id": "CLARIDEN-7", "start": "2026-10-03T17:30Z", "end": "2026-10-03T17:45Z", "family": "Visibility", "description": "Last measurement before the gap of 3 October: the same one-measurement bump on D-301-C, D-302-B and PR_BG, D-304-B, D-304-C, P-301-B, with the recognition error of many targets rising. Same signature as the episodes of view obstruction at the station; cause not established, perhaps linked to the station shutdown that follows. Point to ignore.", "review": "2026-11-17", "analysis": "CLARIDEN_2026-10-01T0000_2026-10-11T0000"}
{"id": "CLARIDEN-8", "start": "2026-10-03T17:45Z", "end": "2026-10-05T10:30Z", "family": "No data", "description": "No measurement or image for almost two days, for all sensors, and the station metrics are missing too: the entire station stopped. Voltage and battery normal before and after the gap, so not the signature of a power cut; on resumption, the camera has moved and a blurred object is very close to the lens (10:30 image), which suggests an intervention on the station. Cause not established: the curves are missing over the range.", "review": "2026-11-17", "analysis": "CLARIDEN_2026-10-01T0000_2026-10-11T0000"}
{"id": "CLARIDEN-9", "start": "2026-10-03T17:45Z", "end": "2026-10-05T10:45Z", "family": "Displacement", "description": "After the gap of 3 to 5 October, many targets resume at a different level, and do not return to the previous one until the end of the batch: D-304-C and D-303-C above all, in both directions, then D-302_A and D-301-A, P-299-B, D-300-C, D-303-B and D-304-B horizontally, D-301-C vertically; D-306-B, for its part, returns to its level from before its descent of the evening of the 1st. The raw positions of D-304-C and D-303-C have moved in the image relative to the other targets, the recognition error of several targets (D-302-C, D-301-C, D-303-C, D-304-C, D-301-A, D-306-B) also changes level, and the camera scale is no longer the same: the appearance of these targets and the camera pose changed during the shutdown. On resumption, a blurred object is very close to the lens (10:30 image). Cause not established: intervention or changed setting during the shutdown, or real movement; to be checked before trusting these new levels.", "review": "2026-11-17", "analysis": "CLARIDEN_2026-10-01T0000_2026-10-11T0000"}
{"id": "CLARIDEN-10", "start": "2026-10-05T10:30Z", "end": "2026-10-05T11:20Z", "family": "Obstruction", "description": "First measurement after the gap: the whole scene, references included, is shifted by several pixels in the image and the camera is tilted, then it returns within twenty minutes; the compensation absorbs it poorly for the duration of one measurement, and the corrected curves of many targets jump then return (D-303-C, D-302-B and PR_BG, D-306-B, D-304-B, P-299-C above all; D-303-B stays slightly shifted until 11:10). D-304-C is rejected. The 10:30 image shows a large blurred object very close to the lens, on the right, which hides D-304-C, and a worker in reflective clothing in the tunnel, at the top left: work is going on around the camera. Points to ignore; the structure does not move.", "review": "2026-11-17", "analysis": "CLARIDEN_2026-10-01T0000_2026-10-11T0000"}
{"id": "CLARIDEN-11", "start": "2026-10-05T12:10Z", "end": "2026-10-05T12:30Z", "family": "Obstruction", "description": "For the duration of one measurement, the whole right-hand row C (D-300-C, D-301-C, D-303-C, D-304-C, P-298-C, P-299-C) and the reference D-302-C are rejected, their recognition error almost at 1; the compensation runs without D-302-C and the targets that stayed under the threshold jump then return at the next measurement (D-306-B above all vertically, D-303-B, D-304-B, P-299-B, P-301-B, D-302-B and PR_BG). No image at 12:20: the cause is not seen, but the signature is that of something passing in front of the right-hand part of the scene. Point to ignore.", "review": "2026-11-17", "analysis": "CLARIDEN_2026-10-01T0000_2026-10-11T0000"}
{"id": "CLARIDEN-12", "start": "2026-10-06T18:00Z", "end": "2026-10-06T22:10Z", "family": "Visibility", "description": "For four hours, the corrected curves of the same group of targets take a step that starts and ends sharply: D-301-C horizontally above all, D-302-B and PR_BG (same prism) horizontally then vertically, D-304-B vertically, and at times P-301-B, D-303-B, D-302_A, D-301-A, D-304-C. The recognition error of the references PR-293, PR-295, PR-296 and of a few targets rises a little; the references move away from each other in the image. The camera housing temperature drops clearly over these hours. Nothing visible on the 20:00 image. View obstruction of cause not established, probably the tunnel air (colder); the curves and the recognition error return at 22:00, before the camera scale. The structure does not move: curves to ignore over the range.", "review": "2026-11-18", "analysis": "CLARIDEN_2026-10-01T0000_2026-10-11T0000"}