auto: the reviews of 2026-11-18 on CLARIDEN, FLORIDA, MICHIGAN, NEBRASKA, NORDEND, WILDSTRUBEL, and their analysis copies

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
maximeandClaude Opus 5.5 committed 2026-11-18 17:47:59 +01:00
1 parent 58b630f2d5
commit 3b80b7c963
14 files changed
+140 -140

No files matched your search

@@ -6,4 +6,4 @@
{"start": "2026-10-03T17:45Z", "end": "2026-10-05T10:45Z", "family": "Displacement", "description": "After the gap of 3 to 5 October, many targets resume at a different level, and do not return to the previous one until the end of the batch: D-304-C and D-303-C above all, in both directions, then D-302_A and D-301-A, P-299-B, D-300-C, D-303-B and D-304-B horizontally, D-301-C vertically; D-306-B, for its part, returns to its level from before its descent of the evening of the 1st. The raw positions of D-304-C and D-303-C have moved in the image relative to the other targets, the recognition error of several targets (D-302-C, D-301-C, D-303-C, D-304-C, D-301-A, D-306-B) also changes level, and the camera scale is no longer the same: the appearance of these targets and the camera pose changed during the shutdown. On resumption, a blurred object is very close to the lens (10:30 image). Cause not established: intervention or changed setting during the shutdown, or real movement; to be checked before trusting these new levels.", "review": "2026-11-17"}
{"start": "2026-10-05T10:30Z", "end": "2026-10-05T11:20Z", "family": "Obstruction", "description": "First measurement after the gap: the whole scene, references included, is shifted by several pixels in the image and the camera is tilted, then it returns within twenty minutes; the compensation absorbs it poorly for the duration of one measurement, and the corrected curves of many targets jump then return (D-303-C, D-302-B and PR_BG, D-306-B, D-304-B, P-299-C above all; D-303-B stays slightly shifted until 11:10). D-304-C is rejected. The 10:30 image shows a large blurred object very close to the lens, on the right, which hides D-304-C, and a worker in reflective clothing in the tunnel, at the top left: work is going on around the camera. Points to ignore; the structure does not move.", "review": "2026-11-17"}
{"start": "2026-10-05T12:10Z", "end": "2026-10-05T12:30Z", "family": "Obstruction", "description": "For the duration of one measurement, the whole right-hand row C (D-300-C, D-301-C, D-303-C, D-304-C, P-298-C, P-299-C) and the reference D-302-C are rejected, their recognition error almost at 1; the compensation runs without D-302-C and the targets that stayed under the threshold jump then return at the next measurement (D-306-B above all vertically, D-303-B, D-304-B, P-299-B, P-301-B, D-302-B and PR_BG). No image at 12:20: the cause is not seen, but the signature is that of something passing in front of the right-hand part of the scene. Point to ignore.", "review": "2026-11-17"}
{"start": "2026-10-06T18:00Z", "end": "2026-10-06T22:10Z", "family": "Visibility", "description": "For four hours, the corrected curves of the same group of targets take a step that starts and ends sharply: D-301-C horizontally above all, D-302-B and PR_BG (same prism) horizontally then vertically, D-304-B vertically, and at times P-301-B, D-303-B, D-302_A, D-301-A, D-304-C. The recognition error of the references PR-293, PR-295, PR-296 and of a few targets rises a little; the references move away from each other in the image. The camera housing temperature drops clearly over these hours. Nothing visible on the 20:00 image. View obstruction of cause not established, probably the tunnel air (colder); the curves and the recognition error return at 22:00, before the camera scale. The structure does not move: curves to ignore over the range."}
{"start": "2026-10-06T18:00Z", "end": "2026-10-06T22:10Z", "family": "Visibility", "description": "For four hours, the corrected curves of the same group of targets take a step that starts and ends sharply: D-301-C horizontally above all, D-302-B and PR_BG (same prism) horizontally then vertically, D-304-B vertically, and at times P-301-B, D-303-B, D-302_A, D-301-A, D-304-C. The recognition error of the references PR-293, PR-295, PR-296 and of a few targets rises a little; the references move away from each other in the image. The camera housing temperature drops clearly over these hours. Nothing visible on the 20:00 image. View obstruction of cause not established, probably the tunnel air (colder); the curves and the recognition error return at 22:00, before the camera scale. The structure does not move: curves to ignore over the range.", "review": "2026-11-18"}
@@ -15,6 +15,6 @@
{"start": "2026-10-07T08:45Z", "end": "2026-10-07T20:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day. Most of it is absorbed by the compensation, but not all: the corr_y of Sellette 6 rises clearly above its night level in the afternoon and comes back in the evening, and the corr_y of Massif 2 dips around midday; the other targets stay close to their night level. Deduced: the camera movement follows the housing temperature, ordinary error_value. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-18"}
{"start": "2026-10-08T03:15Z", "end": "2026-10-09T08:00Z", "family": "Visibility", "description": "Rainy day and damp night: the error_value of the targets and the references rises from 3h30, and the targets jump from that measurement; p1_r (and its twin Sellette 3) is rejected at times until the evening, Sellette 4 and Sellette 5 almost over the whole range, Massif 2 and Sellette 6 often. When p1_r is kept but poorly seen, the camera pose goes off (tilt, scale) and the corr of all the targets jumps strongly; when it is rejected, no more registration. Seen on the images: drops on the leaves at 05:00, scene veiled at 14:00, smaller spots. Back on the morning of the 9th. Not a movement: curves of the range to ignore.", "review": "2026-11-17"}
{"start": "2026-10-09T01:45Z", "end": "2026-10-09T02:15Z", "family": "No data", "description": "One measurement absent for all sensors, and no image at that moment; the station nevertheless synchronizes at that moment and its voltage is normal: it is running, the measurement is missing; measurements resume at the next one. This one-measurement gap in the night, around 02:00 UTC, falls on the same measurement at FLORIDA and SNCF01 on 09, 14 and 15/10, and only on them; other stations have the same night gap around the same hour in other weeks (JUNGFRAU and NORDEND in early September): a common cause outside the station, at night, is probable; it is not established. Nothing to do on the station if it does not get worse.", "review": "2026-11-17"}
{"start": "2026-10-09T08:00Z", "end": "2026-10-09T13:30Z", "family": "Perturbation", "description": "After the rain episode of the 8th, the corr_x of Sellette 5, already shifted upward at the end of the rain, and that of Sellette 4, which joins it in the early afternoon of the 9th, take a slightly higher level and stay there until the morning of the 15th; at the same time the camera pose has changed level (tilt, scale) and the error_value of r1_r is lower than before the rain. A reference spot that changes appearance changes the basis; the housing temperature also drops on those days and rises again when the shift fades, but at equal temperature, on the 17th and 18th, Sellette 5 does not have this level: link not established. Cause not established. The shift fades on the morning of the 15th: nothing to do, points to ignore."}
{"start": "2026-10-09T08:00Z", "end": "2026-10-09T13:30Z", "family": "Perturbation", "description": "After the rain episode of the 8th, the corr_x of Sellette 5, already shifted upward at the end of the rain, and that of Sellette 4, which joins it in the early afternoon of the 9th, take a slightly higher level and stay there until the morning of the 15th; at the same time the camera pose has changed level (tilt, scale) and the error_value of r1_r is lower than before the rain. A reference spot that changes appearance changes the basis; the housing temperature also drops on those days and rises again when the shift fades, but at equal temperature, on the 17th and 18th, Sellette 5 does not have this level: link not established. Cause not established. The shift fades on the morning of the 15th: nothing to do, points to ignore.", "review": "2026-11-18"}
{"start": "2026-10-10T06:45Z", "end": "2026-10-10T20:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day. Apart from the p1_r episode of the morning (labeled separately), the corrected curves keep part of it: the corr_x of Sellette 6 and Massif 2 rise above their night level in the afternoon, then at the end of the day the corr_x of Sellette 5 and the corr_y of Sellette 6 go below it before returning to it in the night. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the morning episode. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-18"}
{"start": "2026-10-10T07:15Z", "end": "2026-10-10T11:30Z", "family": "Visibility", "description": "In the morning, the error_value of p1_r rises from 7h30 and the corr_y of Sellette 4 and Sellette 5 shifts; then p1_r (and its twin Sellette 3) goes above the threshold and is rejected for several measurements, Sellette 5 and Sellette 6 too: the camera is no longer registered, and at the kept measurements the corr_x of Sellette 4 jumps clearly then returns. Thumbnails: the spot of p1_r has a wider halo at 09:00 than at 13:00, scene in full daylight without obstacle; probably the morning light, cause not established. Not a movement: curves of the range to ignore.", "review": "2026-11-17"}
@@ -1,4 +1,4 @@
{"start": "2026-10-03T00:00Z", "end": "2026-10-05T16:00Z", "family": "Target issue", "description": "From the start of the data to 5 October at noon, COLH21' and REFH22' give exactly the same positions, the same error_value and the same corrected curves: the two sensors are placed on the same point of a group of spots, and their corr_y is clearly lower than that of their neighbors. At the 16:00 measurement on 5 October, they separate: on the 12:00 and 16:00 thumbnails, the scene is the same, but COLH21' is now centered on the top of the group and REFH22' on the bottom; their corr_y jumps toward that of their neighbors and stays there, their error_value drops. At the same moment, the raw positions of several other targets, including COLH18', change a little without their corrected curves moving, and the camera does not move. Cause deduced, not established: the sensors were reconfigured, and COLH21' and REFH22' were badly configured before, placed on the same point; the jump at 16:00 is the return to normal. For the customer: this is not a movement of the structure; the curves of COLH21' and REFH22' from before 5 October at 16:00 are not to be trusted and cannot be compared with those after; check that the current configuration of these two targets is the right one.", "review": "2026-11-17"}
{"start": "2026-10-04T20:00Z", "end": "2026-10-05T12:00Z", "family": "Thermal displacement", "description": "On 5 October, at the 00:00 measurement, the corr_y of all the targets rises together, a little, most clearly for COLH19N', POUH19N', COLH21'', COLH18S''' and COLH19N''; it partly comes back at 04:00, when the corr_x of several targets (COLH20'', POUH21'', COLH21' and REFH22') rises a little in turn; the corr_y of COLH19N', POUH19N' and COLH19N'' rises a little again at 08:00, then everything is back at 12:00. At the same time, the camera housing temperature drops at once and stays low until it rises again at 12:00, and the camera moves with it: at 00:00 its rotation turns and its tilt goes back a little, at 04:00 and 08:00 it nods forward and its scale drops, at 12:00 it comes back. The raw positions of all the sensors, references included, slide together, the targets without moving relative to each other; the reference REFPOU22 slides a little differently from the targets, and the compensation, still on three references, does not erase all of this movement. COLH21' and REFH22', still placed on the same point (labelled apart), move like the others. Same signature as the night of 6 October (labelled apart). Cause deduced from the curves, the camera pose and the camera housing temperature; nothing in front of the targets on the 00:00 and 08:00 images. Small deviation. For the customer: this is not a movement of the structure, nothing to do.", "review": "2026-11-18"}
{"start": "2026-10-06T00:00Z", "end": "2026-10-06T20:00Z", "family": "Thermal displacement", "description": "On 6 October, at the 04:00 measurement, the corr_y of most targets goes down together, a little, COLH20', COLH21', REFH22', COLH21'', POUH21'' and COLH18S''' the most, and the corr_x of COLH21' and COLH20' rises a little; most come back at 08:00, but the corr_y of COLH18S''' stays low, and a little that of POUH18' and COLH18', until 16:00, and comes back at 20:00. At the same moment, the camera housing temperature makes a brief drop, lowest at 04:00, then rises again until 16:00; the camera nods forward (tilt rising, scale dropping) at 04:00, then comes back gradually until 16:00, and the raw positions of all the sensors, references included, slide together: it is the camera that moves, not the targets; the compensation, still on three references, does not erase all of this movement. The error_value of COLH18', POUH18' and COLH19N' rises a little at 04:00 and returns at 16:00. Same signature as the night of 5 October (labelled apart). Cause deduced from the curves, the camera pose and the camera housing temperature; nothing in front of the targets on the 04:00 image. Small deviation. For the customer: this is not a movement of the structure, nothing to do.", "review": "2026-11-18"}
{"start": "2026-10-08T00:00Z", "end": "2026-10-12T16:00Z", "family": "Displacement", "description": "From 8 to 12 October, the camera gradually nods forward: its tilt rises, its pan and its rotation decrease, and all the targets slide together in the image, shrinking slightly, without moving relative to each other. Until 9 October, on three references, the compensation absorbs most of this movement, but not all: from the 04:00 measurement on 8 October, when the camera takes a clearer step forward, the corr_x of COLH18', POUH18', POUH19N', COLH21', COLH19N' and COLH18S''' rises a little and stays up, the corr_y of POUH19N' goes down a little, and the corrections of the references REF42 and REFG43N move apart. Since the loss of REFPOU22 on 9 October at 12:00 (separate label, which also covers the jump of that measurement), the compensation runs on REF42 and REFG43N alone, which do not follow this movement as the targets do (the scale computed on them even rises): the corr_x of all the targets rises slowly and clearly until the end of the range, under the back-and-forth agitation of the two-reference compensation. From the evening of 12 October, the camera stops and comes back slightly; this is not labelled apart. Deduced from the curves, the camera pose and the raw positions of the targets; nothing on the images. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of the three stations tilt together, in the same direction and on the same dates (advance until 12 October, stop and slight backward movement from 13 to 16, resumption from the 17th to the end of the month), which points to a cause common to the building rather than a fault of this camera alone; at equal housing temperature, the cameras are more tilted at the end of the month than in the middle: temperature does not explain it alone, link not established. For the customer: the targets do not move relative to each other, this is not a movement of the structure; the camera tilt is to be monitored, and restoring a third reference will make the curves reliable again."}
{"start": "2026-10-08T00:00Z", "end": "2026-10-12T16:00Z", "family": "Displacement", "description": "From 8 to 12 October, the camera gradually nods forward: its tilt rises, its pan and its rotation decrease, and all the targets slide together in the image, shrinking slightly, without moving relative to each other. Until 9 October, on three references, the compensation absorbs most of this movement, but not all: from the 04:00 measurement on 8 October, when the camera takes a clearer step forward, the corr_x of COLH18', POUH18', POUH19N', COLH21', COLH19N' and COLH18S''' rises a little and stays up, the corr_y of POUH19N' goes down a little, and the corrections of the references REF42 and REFG43N move apart. Since the loss of REFPOU22 on 9 October at 12:00 (separate label, which also covers the jump of that measurement), the compensation runs on REF42 and REFG43N alone, which do not follow this movement as the targets do (the scale computed on them even rises): the corr_x of all the targets rises slowly and clearly until the end of the range, under the back-and-forth agitation of the two-reference compensation. From the evening of 12 October, the camera stops and comes back slightly; this is not labelled apart. Deduced from the curves, the camera pose and the raw positions of the targets; nothing on the images. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of the three stations tilt together, in the same direction and on the same dates (advance until 12 October, stop and slight backward movement from 13 to 16, resumption from the 17th to the end of the month), which points to a cause common to the building rather than a fault of this camera alone; at equal housing temperature, the cameras are more tilted at the end of the month than in the middle: temperature does not explain it alone, link not established. For the customer: the targets do not move relative to each other, this is not a movement of the structure; the camera tilt is to be monitored, and restoring a third reference will make the curves reliable again.", "review": "2026-11-18"}
@@ -1,4 +1,4 @@
{"start": "2026-10-13T04:00Z", "end": "2026-10-17T04:00Z", "family": "Perturbation", "description": "Slow bump of the corr_y of the top targets (COLJ20, POUJ20, POUJ19, COLJ19, and a little COLH19 and POUH19): it rises by a notch on 13 October in the morning, stays high, then goes back down on 17 October in the morning; the corr_x of COLJ20 and POUJ20 recedes a little at the same time. At the same moment the camera goes back: its tilt goes back down from its peak of 12 October and its pan goes to its lowest of the month, then goes up again on 17 October. The camera housing temperature rises a little at the start then stays stable: link not established. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of BREITHORN and MICHIGAN stop and move back on the same days. Deduced from the curves and the pose: it is the camera that moves, poorly compensated with two references, and the scene deforms with it: POUH20 goes back down with it. For the customer: the camera straightens and the scene deforms with it, then both come back on 17 October: nothing to do over these days; restoring a third reference will make the curves reliable again."}
{"start": "2026-10-13T04:00Z", "end": "2026-10-17T04:00Z", "family": "Perturbation", "description": "Slow bump of the corr_y of the top targets (COLJ20, POUJ20, POUJ19, COLJ19, and a little COLH19 and POUH19): it rises by a notch on 13 October in the morning, stays high, then goes back down on 17 October in the morning; the corr_x of COLJ20 and POUJ20 recedes a little at the same time. At the same moment the camera goes back: its tilt goes back down from its peak of 12 October and its pan goes to its lowest of the month, then goes up again on 17 October. The camera housing temperature rises a little at the start then stays stable: link not established. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of BREITHORN and MICHIGAN stop and move back on the same days. Deduced from the curves and the pose: it is the camera that moves, poorly compensated with two references, and the scene deforms with it: POUH20 goes back down with it. For the customer: the camera straightens and the scene deforms with it, then both come back on 17 October: nothing to do over these days; restoring a third reference will make the curves reliable again.", "review": "2026-11-18"}
{"start": "2026-10-15T20:00Z", "end": "2026-10-16T12:00Z", "family": "No data", "description": "No measurement for any sensor for three measurements, in the night of 15 to 16 October: all the curves are missing, then resume at the same level as before the gap. The station metrics (voltage, temperatures) are also missing over the same range; the voltage is normal just before and just after, so it is not a lack of energy. The same gap affects the two other stations of the building (BREITHORN, MICHIGAN, in the same building according to the expert), but also all the other stations. The gap starts at the same time, around 23:00, on the nine stations that were measuring then (LENZSPITZE only has its first measurements in the middle of that night, WILDSTRUBEL is already stopped), and their metrics stop at the same time on most of them; measurements and metrics resume at different times depending on the station, most of them in late morning. JUNGFRAU, whose metrics continue, accumulates unsent entries all night, sent in late morning, and yet its measurements for the night are missing from the data: a common cause outside the stations (transmission or reception of the data), not a shutdown of the stations; it is not established. The cause is therefore not specific to the building. The curves are missing over the range; nothing to do on the station if it does not repeat.", "review": "2026-11-17"}
{"start": "2026-10-16T20:00Z", "end": "2026-10-17T20:00Z", "family": "Displacement", "description": "The corr_x of COLJ19 alone jumps upward at the midnight measurement on 17 October, stays high all day, then partly returns in the evening; its neighbors do not jump. Its raw position in the image shifts by as much relative to the other targets, without the camera moving at that moment or its error_value changing; nothing on the thumbnails. It is not an effect of the compensation; cause not established, deduced from the curves and the raw positions. To be checked: look at the target and monitor its curve.", "review": "2026-11-17"}
{"start": "2026-10-18T16:00Z", "end": "2026-10-19T16:00Z", "family": "Thermal displacement", "description": "Cool morning of 19 October, the coldest of the month so far for the camera housing: the corr_y of POUJ19, COLJ20 and POUH20 rises from the evening of the 18th until noon, then returns; the corr_x of almost all the targets makes a peak at the 08:00 measurement (COLH19, COLH20, COLH21, POUH19, COLJ20). The camera nods forward during the night, most at 08:00, where its pan moves and its scale drops too, then everything returns. No reference poorly seen. Deduced from the curves, the pose and the temperatures: a brief camera movement with the cold, poorly compensated by the two-reference basis, like the cold mornings at the end of the month. The targets do not move: nothing to do, do not trust these points.", "review": "2026-11-17"}
@@ -15,7 +15,7 @@
{"start": "2026-08-28T14:15Z", "end": "2026-08-28T14:45Z", "family": "Visibility", "description": "In the afternoon, for one measurement, the error_value of all the sensors, references included, rises together, and PR18, PR09 and PR14 jump a little on corr_x; everything comes back at the next measurement. At that measurement CTR01 (local reference, treated as a target) is rejected: on the 14:30 thumbnail, the rock around it is in full sun, as bright as its spot. Cause of the jump of the others not established (an image of the whole scene less clean for one measurement, in strong sun; no object, no camera step). The structure does not move: point to ignore.", "review": "2026-11-18"}
{"start": "2026-08-28T15:15Z", "end": "2026-08-28T17:30Z", "family": "Visibility", "description": "Afternoon of reduced visibility: the error_value of the three references rises together without getting them rejected, then PR07, PR09, PR11, PR12, PR14, PR15, PR16 are rejected for one or two measurements, and PR07, PR13, PR15, PR16, PR08 jump on corr_x or corr_y until late afternoon. On the 16:15 image, a blurred band (cobweb thread) can be guessed at the bottom of the scene. Cause not established (perhaps the cobweb, by day). The structure does not move: points to ignore.", "review": "2026-11-17"}
{"start": "2026-08-29T06:00Z", "end": "2026-08-30T06:15Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up, the camera turns gradually (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18, PR16, PR15 and PR14 drops markedly, the corr_y of PR18 rises, then the curves come back in the afternoon; the camera then comes back slowly, in the evening and all night (the pan rises again), until the start of the next morning. Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-29T11:45Z", "end": "2026-08-29T12:15Z", "family": "Displacement", "description": "For one measurement, the camera makes a small step (pan and rotation: the raw positions of all the sensors shift together) and keeps most of it afterwards; at that measurement the compensation does not quite absorb it: the corr_x of PR15 and PR16, and more weakly of PR14, jumps together, and the reference CTR04 departs a little from the overall movement; everything comes back at the next measurement. The error_value of the sensors stays at its level and no reference is lost; on the 12:00 thumbnails the spots are intact and nothing is in front of them, the scene a little darker than a measurement earlier. Cause not established: this is not a movement of the structure; the camera moved and keeps its new position: its mount is to be checked."}
{"start": "2026-08-29T11:45Z", "end": "2026-08-29T12:15Z", "family": "Displacement", "description": "For one measurement, the camera makes a small step (pan and rotation: the raw positions of all the sensors shift together) and keeps most of it afterwards; at that measurement the compensation does not quite absorb it: the corr_x of PR15 and PR16, and more weakly of PR14, jumps together, and the reference CTR04 departs a little from the overall movement; everything comes back at the next measurement. The error_value of the sensors stays at its level and no reference is lost; on the 12:00 thumbnails the spots are intact and nothing is in front of them, the scene a little darker than a measurement earlier. Cause not established: this is not a movement of the structure; the camera moved and keeps its new position: its mount is to be checked.", "review": "2026-11-18"}
{"start": "2026-08-29T16:00Z", "end": "2026-08-29T19:00Z", "family": "Visibility", "description": "In late afternoon, PR07 is rejected for two measurements and its corr_x curve jumps several times until the evening, PR16 and PR15 a little; the spot of PR07 is very weak on the 16:30 thumbnail, without any obstacle. Weak target, poorly seen at this hour; points to ignore.", "review": "2026-11-17"}
{"start": "2026-08-29T22:15Z", "end": "2026-08-29T23:30Z", "family": "Visibility", "description": "At night, PR07 is rejected for one measurement and PR15, PR16 jump on corr_x and corr_y; the 22:30 image is very noisy and the spot of PR07 is lost in it. Points to ignore, nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-30T00:15Z", "end": "2026-08-30T01:15Z", "family": "Visibility", "description": "At night, PR07, PR09, PR11, PR12 and PR14 are rejected for one or two measurements, and PR14, PR15, PR12, PR16 jump on corr_x or corr_y; the 00:45 image is very noisy, with blurred discs in the corners, the spots weak. Points to ignore, nothing to do.", "review": "2026-11-17"}
@@ -12,7 +12,7 @@
{"start": "2026-09-07T05:30Z", "end": "2026-09-08T06:45Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up strongly, the camera turns all at once (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18, PR16, PR15 and PR14 drops strongly, the corr_y of PR18 rises, then the curves come back in the afternoon; the camera then comes back slowly, in the evening, then only very little at night, until the start of the next morning. Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17"}
{"start": "2026-09-08T00:45Z", "end": "2026-09-08T01:15Z", "family": "No data", "description": "One measurement is missing for all the sensors, at night: all the curves have a gap. The image of that instant exists, the station synchronised at that instant (last_sync) and its voltage is normal: the station is running, the measurement of that instant is missing from the data. JUNGFRAU (which loses the previous measurement) and WILDSTRUBEL measure at that instant: gap specific to the station, cause not established. The curves resume at the next measurement: nothing to do.", "review": "2026-11-17"}
{"start": "2026-09-08T01:45Z", "end": "2026-09-08T02:45Z", "family": "Visibility", "description": "At night, PR07 is rejected for two measurements: its curve is missing; at the same time PR16 jumps on corr_x and corr_y, and PR15 a little on corr_x, then they come back at the measurement that follows the rejections. The 02:00 image is very noisy and the weak spot of PR07 is lost in it. Points to ignore, nothing to do.", "review": "2026-11-18"}
{"start": "2026-09-08T05:30Z", "end": "2026-09-08T08:15Z", "family": "Perturbation", "description": "Early in the morning, the corr_x of PR07 alone drops below its level, a little at first, then clearly for more than an hour, without rejection, and comes back gradually; its corr_y rises a little and its error_value rises at the same time, without reaching the threshold. The other targets do not follow it. Its spot is weak on the 07:00 thumbnail, without visible obstacle. Cause not established (a weakened spot, or a brief movement of PR07 itself); the curve comes back by itself the same morning: nothing to do, points to ignore."}
{"start": "2026-09-08T05:30Z", "end": "2026-09-08T08:15Z", "family": "Perturbation", "description": "Early in the morning, the corr_x of PR07 alone drops below its level, a little at first, then clearly for more than an hour, without rejection, and comes back gradually; its corr_y rises a little and its error_value rises at the same time, without reaching the threshold. The other targets do not follow it. Its spot is weak on the 07:00 thumbnail, without visible obstacle. Cause not established (a weakened spot, or a brief movement of PR07 itself); the curve comes back by itself the same morning: nothing to do, points to ignore.", "review": "2026-11-18"}
{"start": "2026-09-08T06:45Z", "end": "2026-09-09T06:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up, the camera turns gradually (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18 drops a little, the corr_y of PR18 hardly moves, then the curves come back in the afternoon; the camera then comes back slowly, in the evening and all night (the pan rises again), until the start of the next morning. In early evening, when the pose starts moving again, several targets move a little for one measurement. Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17"}
{"start": "2026-09-09T06:00Z", "end": "2026-09-10T04:30Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up, the camera turns all at once (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18, PR16, PR15 and PR14 drops markedly, the corr_y of PR18 rises, then the curves come back in the afternoon; the camera then comes back slowly, in the evening and all night (the pan rises again), until the start of the next morning. Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17"}
{"start": "2026-09-09T14:45Z", "end": "2026-09-09T16:00Z", "family": "Visibility", "description": "CTR01 (local reference, treated as a target) is rejected for two measurements in a row in the afternoon: its corr_x and corr_y curves are missing. Deduced cause: same hour and same signature as the other sunny afternoons, where the thumbnails show the rock in full sun around the target and the spot drowning in it (16/08, 21 and 22/09). At the second of them, the error_value of almost all the sensors rises and several targets move a little: PR18, PR15 and PR08 on corr_y, PR14, PR05 and PR01 on corr_x, most for one measurement, PR08 and PR15 coming back on corr_y only half an hour later. The other targets remain measured. The structure does not move: nothing to do, CTR01's curve is missing on sunny afternoons.", "review": "2026-11-18"}
@@ -27,4 +27,4 @@
{"start": "2026-10-12T06:45Z", "end": "2026-10-12T19:30Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera: in the morning, when the housing heats up in the sun (markedly, highest around 12:00), the camera turns: the pan drops markedly, the tilt rises a little less, the scale increases; then it comes back in the afternoon and the evening, still partly when, at nightfall, the camera makes a step that stops the cycle (separate label, Displacement); afterwards the housing temperature no longer drops and the pose stays at its new level until the end of the batch, apart from a back-and-forth later in the night (separate label). The compensation absorbs it better than on the other sunny days: the corr_x of PR18 drops markedly around 11:00 and comes back from 13:00, that of PR16 a little; the corr_y of PR08 drops a little to markedly in the afternoon, those of PR09 and PR01 rise a little. The departures of PR17 come from the mark on the window (separate label), the common jumps of mid-afternoon from the sun on the references (separate label). Deduced cause: the pose follows the housing temperature, and the rock face of the quarry does not move with the temperature. The structure does not move, nothing to do.", "review": "2026-11-18"}
{"start": "2026-10-12T14:00Z", "end": "2026-10-12T16:15Z", "family": "Visibility", "description": "In the afternoon, the sun lights the rock behind the references CTR02 and CTR03 and behind CTR01 (local reference, treated as a target), as bright as their spots, which drown in it (15:30 and 16:00 thumbnails). CTR02 and CTR03 stay under their threshold but are seen less well (the error_value of CTR03 rises): the targets jump together a little on corr_y at some measurements, PR01 clearly on both corr_x and corr_y in the second half of the episode, and all of them clearly at the last one, when the camera pose jumps in tilt (PR01, PR02, PR10, PR11 drop), back at the next measurement. CTR01 itself is rejected for a few measurements. The structure does not move: nothing to do; do not trust the curves at those measurements of sunny afternoons.", "review": "2026-11-18"}
{"start": "2026-10-12T19:30Z", "end": "2026-10-12T20:00Z", "family": "Displacement", "description": "At nightfall, the camera moves at once: the tilt jumps (the camera nods down), the pan drops a little, and the raw positions of all the sensors, references included, shift together in the image. The compensation does not erase it all, the references CTR03 and CTR04 not moving exactly like the targets: in one step, the corr_y of almost all the targets drops a little to clearly (PR01, PR02, PR14, PR16 above all), the corr_x of PR18 a little, and the corr_y of the references CTR02 and CTR03 move apart. At the same measurement, the registration residual drops and the error_value of several sensors changes level; afterwards the housing temperature rises a little in the evening instead of dropping. No obstacle on the 19:30 and 19:45 images. The pose and the curves stay at the new level, without return until the end of the batch. Cause not established (a jolt of the camera, or a change in the camera or its lighting). It is not a movement of the structure; the camera is to be monitored.", "review": "2026-11-18"}
{"start": "2026-10-12T22:30Z", "end": "2026-10-13T00:15Z", "family": "Perturbation", "description": "At night, the camera moves for about an hour then comes back: the tilt drops (the camera nods up), the pan jumps for one measurement, and the raw positions of all the sensors shift together in the image. The references CTR03 and CTR04 do not follow the targets exactly, so the compensation leaves a remainder: the corr_y of almost all the targets rise together clearly (PR01, PR02, PR03, PR10, PR14 above all), those of the references CTR02 and CTR03 move apart, then everything comes back gradually just after midnight. No reference is rejected and their error_value stays at its level; the housing temperature dips a little at the same hour, much too little to explain the movement; no obstacle on the 23:15 image. At the same time PR17 changes level (mark on the window, separate label). Cause not established. The camera comes back after about an hour: it is not a movement of the structure, nothing to do; points to ignore."}
{"start": "2026-10-12T22:30Z", "end": "2026-10-13T00:15Z", "family": "Perturbation", "description": "At night, the camera moves for about an hour then comes back: the tilt drops (the camera nods up), the pan jumps for one measurement, and the raw positions of all the sensors shift together in the image. The references CTR03 and CTR04 do not follow the targets exactly, so the compensation leaves a remainder: the corr_y of almost all the targets rise together clearly (PR01, PR02, PR03, PR10, PR14 above all), those of the references CTR02 and CTR03 move apart, then everything comes back gradually just after midnight. No reference is rejected and their error_value stays at its level; the housing temperature dips a little at the same hour, much too little to explain the movement; no obstacle on the 23:15 image. At the same time PR17 changes level (mark on the window, separate label). Cause not established. The camera comes back after about an hour: it is not a movement of the structure, nothing to do; points to ignore.", "review": "2026-11-18"}
@@ -26,7 +26,7 @@
{"start": "2026-10-01T03:15Z", "end": "2026-10-01T05:45Z", "family": "No data", "description": "No measurement for any sensor during the night, except two isolated measurements at 04:45 and 05:15 before the restart. The station shuts down for lack of energy: just before the outage, the battery is at its lowest and the voltage below its usual night level, and the metrics stop with the measurements; it restarts at sunrise with the solar charge, the compute board still cold (metrics). The curves are missing; nothing moves on the structure, but the station does not have enough energy to last the night: to be checked (battery, panel).", "review": "2026-11-17"}
{"start": "2026-10-01T04:45Z", "end": "2026-10-01T12:30Z", "family": "Thermal displacement", "description": "From sunrise until around noon, the camera moves through thermal effect, as every day: the tilt started to rise (the camera nods down) during the end-of-night outage: a little above its night level at the isolated measurement of 04:45, markedly at 06:00; it goes markedly below its level in late morning (at 10:45) and regains at 12:30 its afternoon level, a little below that of the night. The pan drops a little at sunrise (around 05:00-06:00); the rotation goes above its level around 10:00-10:30 and comes back around 12:30; at 08:30, when all the references are lost together, the pose makes a one-measurement jump (separate label); the scale rises with the temperature (markedly at 11:45) and comes back down only in the afternoon, still above its night level at 19:00. In the image, targets and references move together, as a block: y markedly positive at 06:00, then a little negative at 11:00 (ensemble.py --rigide; the targets move away from the block only barely). The housing temperature rises strongly from 04h to 07h (a little less hot at 09h, again at 11h) and stays hot at 12h: the tilt rises with the warming of the morning and comes back while the housing is still hot; the scale follows the temperature and comes back down with it. The compensation follows: on the corrected curves, the tilt wave explains little: before the loss of PA_8, barely more than the noise on each target, except PB1_2 (markedly on corr_x, over few measurements only); what remains is the daytime agitation, the steps of the loss of PA_8 and the common shift taken that day (separate labels). Cause given by the expert for this station (label of 27/09): the camera moves through thermal effect, on its lens or its mount; the road does not move with temperature. Normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-01T08:15Z", "end": "2026-10-01T13:15Z", "family": "Visibility", "description": "The reference PA_8 is rejected continuously from 08:30 to 13:00: the compensation runs without it, and the basis changes. PA_9, its neighbour in the image, rises markedly on corr_x and y stays on a step throughout the range; PA2_2, PA3_2, PB2_2 and PB_5 rise a little. At 08:30 and 09:15, all the references are lost together (08:30 image darker, the scene in shadow, with no obstacle): all targets jump for the time of one measurement, PA_9 especially. Everything comes back in part at 13:15, when PA_8 is taken again; PA_9 stays a little above its morning level until the evening. Cause: PA_8 poorly seen in full daylight, its spot faint on the background (14:00 thumbnail). The step is not a movement: curves of PA_9, PA2_2, PA3_2, PB2_2 and PB_5 not to be trusted over the range.", "review": "2026-11-17"}
{"start": "2026-10-01T13:00Z", "end": "2026-10-01T13:30Z", "family": "Perturbation", "description": "When the reference PA_8 is taken again, on 01/10 at 13:15, all the targets find themselves shifted from their level of late September, with the six references in the compensation: corr_y lower for all of them, together; corr_x higher for PA_9 and PA2_2, lower for PB1_2 and PB_5. The shift occurred between the night and noon, under the thermal movement of the morning and the loss of PA_8 (labelled separately): it cannot be dated more precisely. Relative to the overall movement of the targets, the references PA1_2 and PA_8 moved apart a little, mostly vertically, and R1 horizontally, whereas they followed it the evening before: the basis of references has changed a little, and all the targets inherit it together. The shift remains on 02/10 and 03/10 and fades on 04/10 (return labelled separately). Cause not established (a remainder of the camera movement poorly compensated, or a change in the appearance of these references). Nothing to do: do not read these days as a movement."}
{"start": "2026-10-01T13:00Z", "end": "2026-10-01T13:30Z", "family": "Perturbation", "description": "When the reference PA_8 is taken again, on 01/10 at 13:15, all the targets find themselves shifted from their level of late September, with the six references in the compensation: corr_y lower for all of them, together; corr_x higher for PA_9 and PA2_2, lower for PB1_2 and PB_5. The shift occurred between the night and noon, under the thermal movement of the morning and the loss of PA_8 (labelled separately): it cannot be dated more precisely. Relative to the overall movement of the targets, the references PA1_2 and PA_8 moved apart a little, mostly vertically, and R1 horizontally, whereas they followed it the evening before: the basis of references has changed a little, and all the targets inherit it together. The shift remains on 02/10 and 03/10 and fades on 04/10 (return labelled separately). Cause not established (a remainder of the camera movement poorly compensated, or a change in the appearance of these references). Nothing to do: do not read these days as a movement.", "review": "2026-11-18"}
{"start": "2026-10-01T13:45Z", "end": "2026-10-01T14:15Z", "family": "Visibility", "description": "The reference PA_8 is set aside again for the time of one measurement, after its long loss of the late morning (separate label): its spot is faint on the 14:00 thumbnail. The basis changes: PA2_2 and PB1_2 jump on corr_x, PA_9 and PA3_2 a little. Everything comes back at the next measurement. Cause: PA_8 poorly seen in daylight, as the same morning. The structure is not moving: point to ignore.", "review": "2026-11-18"}
{"start": "2026-10-01T21:30Z", "end": "2026-10-02T05:15Z", "family": "No data", "description": "No measurement for any sensor during the night, except one isolated measurement at 04:45. The station shuts down for lack of energy: just before the outage, the battery is at its lowest and the voltage below its usual night level, and the metrics stop with the measurements; it restarts at sunrise with the solar charge, the compute board still cold (metrics). The curves are missing; nothing moves on the structure, but the station does not have enough energy to last the night: to be checked (battery, panel).", "review": "2026-11-17"}
{"start": "2026-10-02T04:45Z", "end": "2026-10-02T13:00Z", "family": "Thermal displacement", "description": "From sunrise until around noon, the camera moves through thermal effect, as every day: its tilt (the camera nods down) is already high at the isolated measurement of 04:45, highest at 06:15, markedly above its afternoon rest; it goes markedly below this rest in late morning (at 11:30) and regains it at 13:00. The pan is a little lower than in the afternoon in the morning (around 05:15); the rotation goes markedly above its level (at 10:15) and comes back at 13:00; the scale rises with the temperature (markedly at 08:30) and comes back down in the afternoon, at its level around 17:30. In the image, targets and references move together, as a block: y markedly positive at 06:15, then a little negative at 11:30 (ensemble.py --rigide; the targets move away from the block only barely). The housing temperature rises strongly from 04h to 09h and stays hot at 13h: the tilt rises with the warming of the morning and comes back while the housing is still hot; the scale follows the temperature and comes back down with it. The compensation follows: on the corrected curves, the tilt wave explains little, apart from the steps of the loss of PA_8 (from 06:00 to 13:00) and of the first measurements without PA1_2 or PA_8, which make the targets jump; these episodes and the daytime agitation are labelled separately. Cause given by the expert for this station (label of 27/09): the camera moves through thermal effect, on its lens or its mount; the road does not move with temperature. Normal, nothing to do.", "review": "2026-11-17"}