auto: the reviews of 2026-11-18 on CLARIDEN, FLORIDA, MICHIGAN, NEBRASKA, NORDEND, WILDSTRUBEL, and their analysis copies
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
58b630f2d5
commit
3b80b7c963
14 files changed
+140
-140
No files matched your search
@@ -6,4 +6,4 @@
|
||||
{"start": "2026-10-03T17:45Z", "end": "2026-10-05T10:45Z", "family": "Displacement", "description": "After the gap of 3 to 5 October, many targets resume at a different level, and do not return to the previous one until the end of the batch: D-304-C and D-303-C above all, in both directions, then D-302_A and D-301-A, P-299-B, D-300-C, D-303-B and D-304-B horizontally, D-301-C vertically; D-306-B, for its part, returns to its level from before its descent of the evening of the 1st. The raw positions of D-304-C and D-303-C have moved in the image relative to the other targets, the recognition error of several targets (D-302-C, D-301-C, D-303-C, D-304-C, D-301-A, D-306-B) also changes level, and the camera scale is no longer the same: the appearance of these targets and the camera pose changed during the shutdown. On resumption, a blurred object is very close to the lens (10:30 image). Cause not established: intervention or changed setting during the shutdown, or real movement; to be checked before trusting these new levels.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-05T10:30Z", "end": "2026-10-05T11:20Z", "family": "Obstruction", "description": "First measurement after the gap: the whole scene, references included, is shifted by several pixels in the image and the camera is tilted, then it returns within twenty minutes; the compensation absorbs it poorly for the duration of one measurement, and the corrected curves of many targets jump then return (D-303-C, D-302-B and PR_BG, D-306-B, D-304-B, P-299-C above all; D-303-B stays slightly shifted until 11:10). D-304-C is rejected. The 10:30 image shows a large blurred object very close to the lens, on the right, which hides D-304-C, and a worker in reflective clothing in the tunnel, at the top left: work is going on around the camera. Points to ignore; the structure does not move.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-05T12:10Z", "end": "2026-10-05T12:30Z", "family": "Obstruction", "description": "For the duration of one measurement, the whole right-hand row C (D-300-C, D-301-C, D-303-C, D-304-C, P-298-C, P-299-C) and the reference D-302-C are rejected, their recognition error almost at 1; the compensation runs without D-302-C and the targets that stayed under the threshold jump then return at the next measurement (D-306-B above all vertically, D-303-B, D-304-B, P-299-B, P-301-B, D-302-B and PR_BG). No image at 12:20: the cause is not seen, but the signature is that of something passing in front of the right-hand part of the scene. Point to ignore.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-06T18:00Z", "end": "2026-10-06T22:10Z", "family": "Visibility", "description": "For four hours, the corrected curves of the same group of targets take a step that starts and ends sharply: D-301-C horizontally above all, D-302-B and PR_BG (same prism) horizontally then vertically, D-304-B vertically, and at times P-301-B, D-303-B, D-302_A, D-301-A, D-304-C. The recognition error of the references PR-293, PR-295, PR-296 and of a few targets rises a little; the references move away from each other in the image. The camera housing temperature drops clearly over these hours. Nothing visible on the 20:00 image. View obstruction of cause not established, probably the tunnel air (colder); the curves and the recognition error return at 22:00, before the camera scale. The structure does not move: curves to ignore over the range."}
|
||||
{"start": "2026-10-06T18:00Z", "end": "2026-10-06T22:10Z", "family": "Visibility", "description": "For four hours, the corrected curves of the same group of targets take a step that starts and ends sharply: D-301-C horizontally above all, D-302-B and PR_BG (same prism) horizontally then vertically, D-304-B vertically, and at times P-301-B, D-303-B, D-302_A, D-301-A, D-304-C. The recognition error of the references PR-293, PR-295, PR-296 and of a few targets rises a little; the references move away from each other in the image. The camera housing temperature drops clearly over these hours. Nothing visible on the 20:00 image. View obstruction of cause not established, probably the tunnel air (colder); the curves and the recognition error return at 22:00, before the camera scale. The structure does not move: curves to ignore over the range.", "review": "2026-11-18"}
|
||||
Reference in new issue