English: label map, families, labeling rules, knowledge/, validate.py (ex controle.py), ids.py, precedents.py; the labels of auto/ translated, keys start/end/family/review/analysis (manual/: keys only); analysis folders renamed; the 2026-11-16 trial analysis (NORDEND-243)
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
4d926ecddc
commit
68a0eefd8b
79 files changed
+2789
-2652
No files matched your search
+15
-15
@@ -1,15 +1,15 @@
|
||||
{"id": "MICHIGAN-1", "debut": "2026-10-03T00:00Z", "fin": "2026-10-05T16:00Z", "categorie": "Target issue", "description": "Du début des données au 5 octobre à midi, COLH21' et REFH22' donnent exactement les mêmes positions, la même error_value et les mêmes courbes corrigées : les deux capteurs sont posés sur le même point d'un groupe de taches, et leur corr_y est nettement plus bas que celui de leurs voisines. À la mesure de 16:00 le 5 octobre, ils se séparent : sur les vignettes de 12:00 et de 16:00, la scène est la même, mais COLH21' est désormais centré sur le haut du groupe et REFH22' sur le bas ; leur corr_y saute vers celui de leurs voisines et y reste, leur error_value baisse. Au même instant, les positions brutes de plusieurs autres cibles, dont COLH18', changent un peu sans que leurs courbes corrigées bougent, et la caméra ne bouge pas. Cause déduite, pas établie : les capteurs ont été reconfigurés, et COLH21' et REFH22' étaient mal configurés avant, posés sur le même point ; le saut de 16:00 est le retour à la normale. Pour le client : ce n'est pas un mouvement de l'ouvrage ; les courbes de COLH21' et de REFH22' d'avant le 5 octobre à 16:00 ne sont pas à croire et ne se comparent pas à celles d'après ; vérifier que la configuration actuelle de ces deux cibles est la bonne.", "revue": "2026-11-04"}
|
||||
{"id": "MICHIGAN-2", "debut": "2026-10-06T00:00Z", "fin": "2026-10-06T08:00Z", "categorie": "Thermal displacement", "description": "Le temps d'une mesure, le 6 octobre à 04:00, le corr_y de la plupart des cibles baisse ensemble, un peu, puis revient à la mesure suivante. Au même moment, la température du boîtier de la caméra fait une baisse brève, en fin de nuit, la caméra pique un peu du nez (tilt qui monte, échelle qui baisse) et les positions brutes de tous les capteurs, références comprises, glissent ensemble : c'est la caméra qui bouge, pas les cibles ; la compensation, encore sur trois références, n'efface pas tout ce mouvement. Cause déduite des courbes et de la température du boîtier de la caméra ; rien devant les cibles sur l'image de 04:00. Petit écart. Pour le client : ce n'est pas un mouvement de l'ouvrage, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "MICHIGAN-3", "debut": "2026-10-09T08:00Z", "fin": "2026-11-01T00:00Z", "categorie": "Target issue", "description": "La référence REFPOU22 est perdue le 9 octobre entre la mesure de 08:00 et celle de 12:00, et ne revient pas jusqu'à la fin du mois : son error_value monte presque au maximum, elle est rejetée à toutes les mesures et ses positions brutes errent loin de sa place. Sur les vignettes, sa tache, nette à 04:00 et à 08:00 le 9 octobre, a disparu à 12:00 et ne revient pas (vue aussi le 12 octobre, le 20 octobre et le 31 octobre), alors que les taches voisines et REF42, REFG43N sont intactes ; aucun obstacle n'est visible. À 12:00 le 9 octobre, corr_x et corr_y de toutes les cibles sautent ensemble et restent décalés, sans marche des positions brutes : la compensation ne tourne plus que sur REF42 et REFG43N, son erreur de reprojection s'annule et la base change. Avec ces deux références seulement, proches l'une de l'autre et loin des cibles, la compensation est fragile : les courbes de toutes les cibles sont plus agitées qu'avant, et le moindre écart de ces deux références par rapport aux cibles passe, amplifié, dans toutes les cibles. À la même mesure, NEBRASKA, dans le même bâtiment que MICHIGAN d'après l'expert, perd aussi l'une de ses références (REFCOLH22), dont la tache disparaît de même sans obstacle visible : une cause commune aux deux, dans le bâtiment, est à chercher ; elle n'est pas établie. La référence du même nom vue par BREITHORN reste nette sur ses images. Cause de la perte non établie (prisme masqué, tourné ou enlevé). Pour le client : le saut n'est pas un mouvement, et les courbes corrigées depuis le 9 octobre sont peu fiables ; vérifier sur place le prisme de REFPOU22 et le rétablir.", "revue": "2026-11-04"}
|
||||
{"id": "MICHIGAN-4", "debut": "2026-10-09T12:00Z", "fin": "2026-10-12T16:00Z", "categorie": "Displacement", "description": "Du 9 au 12 octobre, la caméra pique du nez peu à peu, tourne et son échelle baisse ; toutes les cibles glissent ensemble dans l'image, sans bouger entre elles. Avec trois références, jusqu'au 9 octobre, ce mouvement était compensé ; depuis la perte de REFPOU22 (étiquette à part), le corr_x de toutes les cibles monte lentement. La compensation sur REF42 et REFG43N seules, depuis la perte de REFPOU22, fait passer ce mouvement dans toutes les cibles. Déduit des courbes et de la pose de la caméra ; rien sur les images. D'après l'expert, BREITHORN, MICHIGAN et NEBRASKA sont dans le même bâtiment : les caméras des trois stations s'inclinent ensemble, dans le même sens et aux mêmes dates (avancée jusqu'au 12 octobre, arrêt et léger recul du 13 au 16, reprise du 17 à la fin du mois), ce qui désigne une cause commune au bâtiment plutôt qu'un défaut de cette seule caméra ; à température du boîtier égale, les caméras sont plus inclinées en fin de mois qu'au milieu : la température ne l'explique pas seule, lien non établi. Pour le client : les cibles ne bougent pas entre elles, ce n'est pas un mouvement de l'ouvrage ; l'inclinaison de la caméra est à surveiller, et rétablir une troisième référence rendra les courbes de nouveau fiables.", "revue": "2026-11-04"}
|
||||
{"id": "MICHIGAN-5", "debut": "2026-10-12T16:00Z", "fin": "2026-10-16T16:00Z", "categorie": "Displacement", "description": "Du 12 octobre au soir au 16 octobre, le corr_x de toutes les cibles redescend ensemble, au plus bas le 15 octobre en fin de journée, puis repart : la caméra arrête de piquer du nez et se redresse un peu. La compensation sur REF42 et REFG43N seules, depuis la perte de REFPOU22, fait passer ce mouvement dans toutes les cibles. Déduit des courbes et de la pose de la caméra ; rien sur les images. D'après l'expert, BREITHORN, MICHIGAN et NEBRASKA sont dans le même bâtiment : les caméras de BREITHORN et de NEBRASKA s'arrêtent et reculent aux mêmes jours, quand la température des boîtiers cesse de baisser, lien non établi. Pour le client : les cibles ne bougent pas entre elles, ce n'est pas un mouvement de l'ouvrage ; l'inclinaison de la caméra est à surveiller, et rétablir une troisième référence rendra les courbes de nouveau fiables.", "revue": "2026-11-04"}
|
||||
{"id": "MICHIGAN-6", "debut": "2026-10-15T20:00Z", "fin": "2026-10-16T12:00Z", "categorie": "No data", "description": "Aucune mesure pour aucun capteur dans la nuit du 15 au 16 octobre : trois mesures manquent, toutes les courbes sont coupées, puis tout reprend au même niveau. Les métriques de la station manquent aussi sur ces heures (températures, tension, synchronisation) ; la tension est normale juste avant et juste après, la batterie pleine : pas de signe de coupure d'alimentation. Le même trou touche les deux autres stations du bâtiment (BREITHORN, NEBRASKA, dans le même bâtiment d'après l'expert), mais aussi toutes les autres stations. Le trou commence à la même heure, vers 23:00, sur les neuf stations qui mesuraient alors (LENZSPITZE n'a ses premières mesures qu'au milieu de cette nuit, WILDSTRUBEL est déjà arrêtée), et leurs métriques s'arrêtent en même temps sur la plupart ; mesures et métriques reprennent à des heures différentes selon la station, la plupart en fin de matinée. JUNGFRAU, dont les métriques continuent, accumule toute la nuit des entrées non envoyées, parties en fin de matinée, et ses mesures de la nuit manquent pourtant aux données : une cause commune hors des stations (transmission ou réception des données), pas une coupure des stations ; elle n'est pas établie. La cause n'est donc pas propre au bâtiment. Les courbes manquent sur la plage ; rien à faire sur la station si cela ne se répète pas.", "revue": "2026-11-04"}
|
||||
{"id": "MICHIGAN-7", "debut": "2026-10-16T12:00Z", "fin": "2026-11-01T00:00Z", "categorie": "Displacement", "description": "Du 16 octobre à la fin du mois, la caméra pique de nouveau du nez, tourne et son échelle baisse, plus vite à partir du 17 octobre avec la baisse de la température du boîtier de la caméra ; toutes les cibles glissent ensemble dans l'image, sans bouger entre elles. Le corr_x de toutes les cibles remonte d'un pas les 17 et 18 octobre et reste haut jusqu'au 28 ; après les matins froids des 29 et 30 octobre, il se retrouve plus bas et y reste jusqu'à la fin du mois ; le corr_y de toutes les cibles descend lentement sur toute la plage. La compensation sur REF42 et REFG43N seules, depuis la perte de REFPOU22, fait passer ce mouvement dans toutes les cibles. Déduit des courbes et de la pose de la caméra ; rien sur les images. D'après l'expert, BREITHORN, MICHIGAN et NEBRASKA sont dans le même bâtiment : les caméras des trois stations s'inclinent ensemble, dans le même sens et aux mêmes dates (avancée jusqu'au 12 octobre, arrêt et léger recul du 13 au 16, reprise du 17 à la fin du mois), ce qui désigne une cause commune au bâtiment plutôt qu'un défaut de cette seule caméra ; à température du boîtier égale, les caméras sont plus inclinées en fin de mois qu'au milieu : la température ne l'explique pas seule, lien non établi. La station est dans une usine, à l'intérieur, d'après l'expert : ce n'est pas un cycle jour/nuit. Pour le client : les cibles ne bougent pas entre elles, ce n'est pas un mouvement de l'ouvrage ; l'inclinaison de la caméra est à surveiller, et rétablir une troisième référence rendra les courbes de nouveau fiables.", "revue": "2026-11-04"}
|
||||
{"id": "MICHIGAN-8", "debut": "2026-10-17T12:00Z", "fin": "2026-10-18T08:00Z", "categorie": "Displacement", "description": "Toutes les cibles s'agitent ensemble pendant trois mesures : le corr_x baisse à 16:00 le 17 octobre, le corr_y plonge à 20:00, puis corr_x et corr_y remontent au-dessus de leur niveau le 18 octobre à 04:00, et tout revient. La pose de la caméra calculée sur REF42 et REFG43N bascule d'avant en arrière (tilt, rotation) sans que les positions brutes des cibles bougent nettement, et l'écart entre les deux références change un peu : c'est la compensation à deux références qui reporte cet écart sur toutes les cibles. Les températures baissent alors par paliers, mais sans variation brève au moment de ces écarts. Cause non établie, rien sur les images. Pour le client : ce n'est pas un mouvement de l'ouvrage, les points de cette plage sont à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "MICHIGAN-9", "debut": "2026-10-19T00:00Z", "fin": "2026-10-19T12:00Z", "categorie": "Thermal displacement", "description": "Le 19 octobre au matin, le corr_y de toutes les cibles plonge ensemble pendant deux mesures, le corr_x aussi à la seconde, puis tout revient à midi. La température du boîtier de la caméra fait au même moment une baisse brève, en fin de nuit, et la caméra bouge : elle pique du nez, tourne, son échelle baisse, les positions brutes de toutes les cibles et des deux références glissent presque ensemble ; les cibles ne bougent pas entre elles. La compensation sur deux références seulement, REF42 et REFG43N, reporte leur petit écart aux cibles sur toutes les cibles. La première mesure touchée précède un peu la baisse de température. Cause déduite des courbes et de la température du boîtier de la caméra ; rien devant les cibles sur l'image de 08:00. Pour le client : ce n'est pas un mouvement de l'ouvrage, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "MICHIGAN-10", "debut": "2026-10-23T20:00Z", "fin": "2026-10-24T20:00Z", "categorie": "Thermal displacement", "description": "Le corr_y de toutes les cibles baisse ensemble le 24 octobre à minuit, remonte en partie dans la matinée, reste bas l'après-midi et revient le soir ; leur corr_x reste un peu plus bas sur toute la plage. La température du boîtier de la caméra baisse au même moment et reste basse jusqu'au soir ; la caméra pique du nez et les positions brutes de toutes les cibles et des deux références glissent presque ensemble, les cibles ne bougent pas entre elles. La compensation sur REF42 et REFG43N seules reporte leur petit écart aux cibles sur toutes les cibles. Cause déduite des courbes et de la température du boîtier de la caméra, pas un cycle jour/nuit ; rien devant les cibles sur l'image de minuit. Petit écart. Pour le client : ce n'est pas un mouvement de l'ouvrage, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "MICHIGAN-11", "debut": "2026-10-25T16:00Z", "fin": "2026-10-26T16:00Z", "categorie": "Thermal displacement", "description": "Le corr_y de toutes les cibles baisse ensemble du 25 octobre au soir jusqu'au matin du 26, le corr_x baisse à son tour le matin du 26, puis tout revient l'après-midi. La température du boîtier de la caméra baisse au même moment et remonte l'après-midi du 26 ; la caméra pique du nez, son échelle baisse, les positions brutes de toutes les cibles et des deux références glissent presque ensemble, les cibles ne bougent pas entre elles. La compensation sur REF42 et REFG43N seules reporte leur petit écart aux cibles sur toutes les cibles. Cause déduite des courbes et de la température du boîtier de la caméra ; rien devant les cibles sur l'image de 04:00 le 26. Pour le client : ce n'est pas un mouvement de l'ouvrage, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "MICHIGAN-12", "debut": "2026-10-26T20:00Z", "fin": "2026-10-27T20:00Z", "categorie": "Displacement", "description": "Le 27 octobre, le corr_y de toutes les cibles monte ensemble au-dessus de son niveau, surtout la nuit et le matin, puis redescend le soir ; le corr_x ne bouge guère. La pose de la caméra calculée sur REF42 et REFG43N bascule (tilt qui baisse nettement) sans que les positions brutes des cibles bougent : ce sont les deux références qui s'écartent un peu des cibles, et la compensation sur elles seules reporte cet écart sur toutes les cibles. Les températures des composants ne font ni creux ni bosse nette, et d'après l'expert, BREITHORN, MICHIGAN et NEBRASKA sont dans le même bâtiment : les caméras de BREITHORN et de NEBRASKA ne bougent pas ce jour-là. Cause non établie, comme l'agitation des 17 et 18 octobre ; rien sur les images. Pour le client : ce n'est pas un mouvement de l'ouvrage, les points de cette plage sont à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "MICHIGAN-13", "debut": "2026-10-28T00:00Z", "fin": "2026-10-28T16:00Z", "categorie": "Thermal displacement", "description": "Le 28 octobre au matin, le corr_x de toutes les cibles baisse un peu à 04:00 et plonge à 08:00, le corr_y aussi, puis le corr_x revient à midi et le corr_y à la mesure suivante. La température du boîtier de la caméra chute au même moment, en fin de nuit, et remonte en fin de matinée ; la caméra pique du nez, son échelle baisse, les positions brutes de toutes les cibles et des deux références glissent presque ensemble, les cibles ne bougent pas entre elles. La compensation sur REF42 et REFG43N seules reporte leur petit écart aux cibles sur toutes les cibles. Cause déduite des courbes et de la température du boîtier de la caméra ; rien devant les cibles sur l'image de 08:00. Pour le client : ce n'est pas un mouvement de l'ouvrage, rien à faire ; le point est à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "MICHIGAN-14", "debut": "2026-10-28T16:00Z", "fin": "2026-10-29T16:00Z", "categorie": "Thermal displacement", "description": "Du 28 octobre au soir au 29 octobre au matin, le corr_x de toutes les cibles descend nettement, ensemble, avec le corr_y, puis remonte d'un coup à la mesure de midi, mais reste nettement sous son niveau d'avant, et ne le retrouve pas jusqu'à la fin du mois ; le corr_y, en partie revenu à midi, ne revient qu'à la mesure suivante. La température du boîtier de la caméra fait en même temps la plus forte baisse du mois et remonte d'un coup en fin de matinée du 29 ; la caméra pique du nez nettement et son échelle baisse, les positions brutes de toutes les cibles glissent ensemble, sans bouger entre elles, et REFG43N s'écarte un peu de leur mouvement ; l'error_value de quelques cibles monte, loin du seuil. La compensation sur REF42 et REFG43N seules reporte et amplifie cet écart sur toutes les cibles. Cause déduite des courbes et de la température du boîtier de la caméra ; rien devant les cibles sur l'image de 08:00. Pour le client : ce n'est pas un mouvement de l'ouvrage, rien à faire ; les courbes de cette plage ne sont pas à croire.", "revue": "2026-11-04"}
|
||||
{"id": "MICHIGAN-15", "debut": "2026-10-29T16:00Z", "fin": "2026-10-30T12:00Z", "categorie": "Thermal displacement", "description": "Du 29 octobre au soir au 30 octobre au matin, le corr_y de toutes les cibles baisse déjà un peu à 20:00, puis le corr_x redescend nettement, ensemble, avec le corr_y qui touche son plus bas en fin de matinée, puis tout remonte à midi. Comme la veille, la température du boîtier de la caméra baisse au même moment et remonte le matin du 30 ; la caméra pique du nez et son échelle baisse, les positions brutes de toutes les cibles glissent ensemble, sans bouger entre elles, et REFG43N s'écarte un peu de leur mouvement ; l'error_value de quelques cibles monte, loin du seuil. La compensation sur REF42 et REFG43N seules reporte et amplifie cet écart sur toutes les cibles. Cause déduite des courbes et de la température du boîtier de la caméra ; rien devant les cibles sur l'image de 04:00. Pour le client : ce n'est pas un mouvement de l'ouvrage, rien à faire ; les courbes de cette plage ne sont pas à croire.", "revue": "2026-11-04"}
|
||||
{"id": "MICHIGAN-1", "start": "2026-10-03T00:00Z", "end": "2026-10-05T16:00Z", "family": "Target issue", "description": "From the start of the data to 5 October at noon, COLH21' and REFH22' give exactly the same positions, the same error_value and the same corrected curves: the two sensors are placed on the same point of a group of spots, and their corr_y is clearly lower than that of their neighbors. At the 16:00 measurement on 5 October, they separate: on the 12:00 and 16:00 thumbnails, the scene is the same, but COLH21' is now centered on the top of the group and REFH22' on the bottom; their corr_y jumps toward that of their neighbors and stays there, their error_value drops. At the same moment, the raw positions of several other targets, including COLH18', change a little without their corrected curves moving, and the camera does not move. Cause deduced, not established: the sensors were reconfigured, and COLH21' and REFH22' were badly configured before, placed on the same point; the jump at 16:00 is the return to normal. For the customer: this is not a movement of the structure; the curves of COLH21' and REFH22' from before 5 October at 16:00 are not to be trusted and cannot be compared with those after; check that the current configuration of these two targets is the right one.", "review": "2026-11-04"}
|
||||
{"id": "MICHIGAN-2", "start": "2026-10-06T00:00Z", "end": "2026-10-06T08:00Z", "family": "Thermal displacement", "description": "For the duration of one measurement, on 6 October at 04:00, the corr_y of most targets goes down together, a little, then returns at the next measurement. At the same moment, the camera housing temperature makes a brief drop, at the end of the night, the camera nods forward slightly (tilt rising, scale dropping) and the raw positions of all the sensors, references included, slide together: it is the camera that moves, not the targets; the compensation, still on three references, does not erase all of this movement. Cause deduced from the curves and the camera housing temperature; nothing in front of the targets on the 04:00 image. Small deviation. For the customer: this is not a movement of the structure, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "MICHIGAN-3", "start": "2026-10-09T08:00Z", "end": "2026-11-01T00:00Z", "family": "Target issue", "description": "The reference REFPOU22 is lost on 9 October between the 08:00 measurement and the 12:00 one, and does not come back until the end of the month: its error_value rises almost to the maximum, it is rejected at every measurement and its raw positions wander far from its place. On the thumbnails, its spot, sharp at 04:00 and 08:00 on 9 October, has disappeared at 12:00 and does not come back (also seen on 12 October, 20 October and 31 October), while the neighboring spots and REF42, REFG43N are intact; no obstacle is visible. At 12:00 on 9 October, corr_x and corr_y of all the targets jump together and stay shifted, without a step in the raw positions: the compensation now only runs on REF42 and REFG43N, its reprojection error drops to zero and the basis changes. With these two references only, close to each other and far from the targets, the compensation is fragile: the curves of all the targets are more agitated than before, and the slightest deviation of these two references relative to the targets passes, amplified, into all the targets. At the same measurement, NEBRASKA, in the same building as MICHIGAN according to the expert, also loses one of its references (REFCOLH22), whose spot disappears in the same way with no visible obstacle: a cause common to both, in the building, is to be looked for; it is not established. The reference of the same name seen by BREITHORN stays sharp on its images. Cause of the loss not established (prism masked, turned or removed). For the customer: the jump is not a movement, and the corrected curves since 9 October are not very reliable; check the prism of REFPOU22 on site and restore it.", "review": "2026-11-04"}
|
||||
{"id": "MICHIGAN-4", "start": "2026-10-09T12:00Z", "end": "2026-10-12T16:00Z", "family": "Displacement", "description": "From 9 to 12 October, the camera gradually nods forward, rotates and its scale drops; all the targets slide together in the image, without moving relative to each other. With three references, until 9 October, this movement was compensated; since the loss of REFPOU22 (separate label), the corr_x of all the targets rises slowly. The compensation on REF42 and REFG43N alone, since the loss of REFPOU22, passes this movement into all the targets. Deduced from the curves and the camera pose; nothing on the images. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of the three stations tilt together, in the same direction and on the same dates (advance until 12 October, stop and slight backward movement from 13 to 16, resumption from the 17th to the end of the month), which points to a cause common to the building rather than a fault of this camera alone; at equal housing temperature, the cameras are more tilted at the end of the month than in the middle: temperature does not explain it alone, link not established. For the customer: the targets do not move relative to each other, this is not a movement of the structure; the camera tilt is to be monitored, and restoring a third reference will make the curves reliable again.", "review": "2026-11-04"}
|
||||
{"id": "MICHIGAN-5", "start": "2026-10-12T16:00Z", "end": "2026-10-16T16:00Z", "family": "Displacement", "description": "From the evening of 12 October to 16 October, the corr_x of all the targets goes back down together, lowest on 15 October at the end of the day, then goes up again: the camera stops nodding forward and straightens a little. The compensation on REF42 and REFG43N alone, since the loss of REFPOU22, passes this movement into all the targets. Deduced from the curves and the camera pose; nothing on the images. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of BREITHORN and NEBRASKA stop and move back on the same days, when the housing temperature stops dropping, link not established. For the customer: the targets do not move relative to each other, this is not a movement of the structure; the camera tilt is to be monitored, and restoring a third reference will make the curves reliable again.", "review": "2026-11-04"}
|
||||
{"id": "MICHIGAN-6", "start": "2026-10-15T20:00Z", "end": "2026-10-16T12:00Z", "family": "No data", "description": "No measurement for any sensor in the night of 15 to 16 October: three measurements are missing, all the curves are cut, then everything resumes at the same level. The station metrics are also missing over these hours (temperatures, voltage, synchronization); the voltage is normal just before and just after, the battery full: no sign of a power cut. The same gap affects the two other stations of the building (BREITHORN, NEBRASKA, in the same building according to the expert), but also all the other stations. The gap starts at the same time, around 23:00, on the nine stations that were measuring then (LENZSPITZE only has its first measurements in the middle of that night, WILDSTRUBEL is already stopped), and their metrics stop at the same time on most of them; measurements and metrics resume at different times depending on the station, most of them in late morning. JUNGFRAU, whose metrics continue, accumulates unsent entries all night, sent in late morning, and yet its measurements for the night are missing from the data: a common cause outside the stations (transmission or reception of the data), not a shutdown of the stations; it is not established. The cause is therefore not specific to the building. The curves are missing over the range; nothing to do on the station if it does not repeat.", "review": "2026-11-04"}
|
||||
{"id": "MICHIGAN-7", "start": "2026-10-16T12:00Z", "end": "2026-11-01T00:00Z", "family": "Displacement", "description": "From 16 October to the end of the month, the camera nods forward again, rotates and its scale drops, faster from 17 October with the drop in the camera housing temperature; all the targets slide together in the image, without moving relative to each other. The corr_x of all the targets rises by a step on 17 and 18 October and stays high until the 28th; after the cold mornings of 29 and 30 October, it ends up lower and stays there until the end of the month; the corr_y of all the targets goes down slowly over the whole range. The compensation on REF42 and REFG43N alone, since the loss of REFPOU22, passes this movement into all the targets. Deduced from the curves and the camera pose; nothing on the images. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of the three stations tilt together, in the same direction and on the same dates (advance until 12 October, stop and slight backward movement from 13 to 16, resumption from the 17th to the end of the month), which points to a cause common to the building rather than a fault of this camera alone; at equal housing temperature, the cameras are more tilted at the end of the month than in the middle: temperature does not explain it alone, link not established. The station is in a factory, indoors, according to the expert: it is not a day/night cycle. For the customer: the targets do not move relative to each other, this is not a movement of the structure; the camera tilt is to be monitored, and restoring a third reference will make the curves reliable again.", "review": "2026-11-04"}
|
||||
{"id": "MICHIGAN-8", "start": "2026-10-17T12:00Z", "end": "2026-10-18T08:00Z", "family": "Displacement", "description": "All the targets become agitated together for three measurements: the corr_x goes down at 16:00 on 17 October, the corr_y plunges at 20:00, then corr_x and corr_y rise above their level on 18 October at 04:00, and everything returns. The camera pose computed on REF42 and REFG43N swings back and forth (tilt, rotation) without the raw positions of the targets moving clearly, and the gap between the two references changes a little: it is the two-reference compensation that carries this gap over to all the targets. The temperatures then drop in steps, but without a brief variation at the time of these deviations. Cause not established, nothing on the images. For the customer: this is not a movement of the structure, the points of this range are to be ignored.", "review": "2026-11-04"}
|
||||
{"id": "MICHIGAN-9", "start": "2026-10-19T00:00Z", "end": "2026-10-19T12:00Z", "family": "Thermal displacement", "description": "On 19 October in the morning, the corr_y of all the targets plunges together for two measurements, the corr_x too at the second, then everything returns at noon. The camera housing temperature makes a brief drop at the same moment, at the end of the night, and the camera moves: it nods forward, rotates, its scale drops, the raw positions of all the targets and of the two references slide almost together; the targets do not move relative to each other. The compensation on two references only, REF42 and REFG43N, carries their small gap relative to the targets over to all the targets. The first affected measurement slightly precedes the temperature drop. Cause deduced from the curves and the camera housing temperature; nothing in front of the targets on the 08:00 image. For the customer: this is not a movement of the structure, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "MICHIGAN-10", "start": "2026-10-23T20:00Z", "end": "2026-10-24T20:00Z", "family": "Thermal displacement", "description": "The corr_y of all the targets goes down together on 24 October at midnight, partly rises again in the morning, stays low in the afternoon and returns in the evening; their corr_x stays slightly lower over the whole range. The camera housing temperature drops at the same moment and stays low until evening; the camera nods forward and the raw positions of all the targets and of the two references slide almost together, the targets do not move relative to each other. The compensation on REF42 and REFG43N alone carries their small gap relative to the targets over to all the targets. Cause deduced from the curves and the camera housing temperature, not a day/night cycle; nothing in front of the targets on the midnight image. Small deviation. For the customer: this is not a movement of the structure, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "MICHIGAN-11", "start": "2026-10-25T16:00Z", "end": "2026-10-26T16:00Z", "family": "Thermal displacement", "description": "The corr_y of all the targets goes down together from the evening of 25 October until the morning of the 26th, the corr_x goes down in turn on the morning of the 26th, then everything returns in the afternoon. The camera housing temperature drops at the same moment and rises again on the afternoon of the 26th; the camera nods forward, its scale drops, the raw positions of all the targets and of the two references slide almost together, the targets do not move relative to each other. The compensation on REF42 and REFG43N alone carries their small gap relative to the targets over to all the targets. Cause deduced from the curves and the camera housing temperature; nothing in front of the targets on the 04:00 image on the 26th. For the customer: this is not a movement of the structure, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "MICHIGAN-12", "start": "2026-10-26T20:00Z", "end": "2026-10-27T20:00Z", "family": "Displacement", "description": "On 27 October, the corr_y of all the targets rises together above its level, mostly at night and in the morning, then goes back down in the evening; the corr_x hardly moves. The camera pose computed on REF42 and REFG43N swings (tilt dropping clearly) without the raw positions of the targets moving: it is the two references that move slightly away from the targets, and the compensation on them alone carries this gap over to all the targets. The component temperatures show neither a dip nor a clear bump, and according to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of BREITHORN and NEBRASKA do not move that day. Cause not established, like the agitation of 17 and 18 October; nothing on the images. For the customer: this is not a movement of the structure, the points of this range are to be ignored.", "review": "2026-11-04"}
|
||||
{"id": "MICHIGAN-13", "start": "2026-10-28T00:00Z", "end": "2026-10-28T16:00Z", "family": "Thermal displacement", "description": "On 28 October in the morning, the corr_x of all the targets goes down a little at 04:00 and plunges at 08:00, the corr_y too, then the corr_x returns at noon and the corr_y at the next measurement. The camera housing temperature drops sharply at the same moment, at the end of the night, and rises again in late morning; the camera nods forward, its scale drops, the raw positions of all the targets and of the two references slide almost together, the targets do not move relative to each other. The compensation on REF42 and REFG43N alone carries their small gap relative to the targets over to all the targets. Cause deduced from the curves and the camera housing temperature; nothing in front of the targets on the 08:00 image. For the customer: this is not a movement of the structure, nothing to do; the point is to be ignored.", "review": "2026-11-04"}
|
||||
{"id": "MICHIGAN-14", "start": "2026-10-28T16:00Z", "end": "2026-10-29T16:00Z", "family": "Thermal displacement", "description": "From the evening of 28 October to the morning of 29 October, the corr_x of all the targets goes down clearly, together, with the corr_y, then rises all at once at the noon measurement, but stays clearly under its previous level, and does not regain it until the end of the month; the corr_y, partly returned at noon, only returns at the next measurement. The camera housing temperature makes the strongest drop of the month at the same time and rises all at once in late morning of the 29th; the camera nods forward clearly and its scale drops, the raw positions of all the targets slide together, without moving relative to each other, and REFG43N moves slightly away from their movement; the error_value of a few targets rises, far from the threshold. The compensation on REF42 and REFG43N alone carries over and amplifies this gap on all the targets. Cause deduced from the curves and the camera housing temperature; nothing in front of the targets on the 08:00 image. For the customer: this is not a movement of the structure, nothing to do; the curves of this range are not to be trusted.", "review": "2026-11-04"}
|
||||
{"id": "MICHIGAN-15", "start": "2026-10-29T16:00Z", "end": "2026-10-30T12:00Z", "family": "Thermal displacement", "description": "From the evening of 29 October to the morning of 30 October, the corr_y of all the targets already goes down a little at 20:00, then the corr_x goes back down clearly, together, with the corr_y touching its lowest in late morning, then everything rises again at noon. As the day before, the camera housing temperature drops at the same moment and rises again on the morning of the 30th; the camera nods forward and its scale drops, the raw positions of all the targets slide together, without moving relative to each other, and REFG43N moves slightly away from their movement; the error_value of a few targets rises, far from the threshold. The compensation on REF42 and REFG43N alone carries over and amplifies this gap on all the targets. Cause deduced from the curves and the camera housing temperature; nothing in front of the targets on the 04:00 image. For the customer: this is not a movement of the structure, nothing to do; the curves of this range are not to be trusted.", "review": "2026-11-04"}
|
||||
Reference in new issue
Block a user