{"id": "NEBRASKA-1", "debut": "2026-10-03T00:00Z", "fin": "2026-10-12T12:00Z", "categorie": "Displacement", "description": "Dès le début des mesures, le 3 octobre, le corr_x des cibles du haut et de la droite de l'image (COLJ20, POUJ20, POUJ19, COLJ19, puis POUH19 et COLH19) monte lentement, sans revenir, jusqu'au 12 octobre vers midi ; celles du bas, près des références, ne bougent presque pas. Dans le même temps, la caméra pique du nez peu à peu : son tilt monte, sa rotation tourne et son échelle baisse, avec un pas plus net de l'après-midi du 7 octobre au 8 octobre, que la compensation absorbe tant que les trois références tiennent (aucune marche sur les courbes ce jour-là). La montée des cibles est faible avec trois références et plus nette après la perte de REFCOLH22 le 9 octobre (le saut de ce jour-là est une autre étiquette). Les positions brutes des cibles bougent surtout avec la caméra : c'est la compensation qui rend mal ce mouvement. La température du boîtier de la caméra ne baisse que peu sur la phase. D'après l'expert, BREITHORN, MICHIGAN et NEBRASKA sont dans le même bâtiment : les caméras des trois stations s'inclinent ensemble, dans le même sens et aux mêmes dates (avancée jusqu'au 12 octobre, arrêt et léger recul du 13 au 16, reprise du 17 à la fin du mois), ce qui désigne une cause commune au bâtiment plutôt qu'un défaut de cette seule caméra ; à température du boîtier égale, les caméras sont plus inclinées en fin de mois qu'au milieu : la température ne l'explique pas seule, lien non établi. Déduite des courbes et de la pose de la caméra. Pour le client : la caméra s'incline et la scène se déforme avec elle : un mouvement de l'ouvrage n'est pas établi ; l'inclinaison de la caméra est à surveiller, et rétablir une troisième référence rendra les courbes de nouveau fiables.", "revue": "2026-11-04"}
{"id": "NEBRASKA-2", "debut": "2026-10-09T08:00Z", "fin": "2026-11-01T00:00Z", "categorie": "Target issue", "description": "La référence REFCOLH22 est perdue à la mesure du 9 octobre à midi et ne revient plus jusqu'à la fin du mois : son error_value saute presque au maximum et toutes ses mesures sont rejetées. Sur les vignettes, sa tache, nette et ronde jusqu'au 9 octobre au matin, a disparu à sa place à la mesure suivante, alors que la tache voisine et les autres références sont intactes ; ce qui l'a fait disparaître (prisme tombé, retiré, caché) n'est pas visible sur l'image entière. À la même mesure, MICHIGAN, dans le même bâtiment que NEBRASKA d'après l'expert, perd aussi l'une de ses références (REFPOU22), dont la tache disparaît de même sans obstacle visible : une cause commune aux deux, dans le bâtiment, est à chercher ; elle n'est pas établie. À la perte, toutes les cibles sautent ensemble en un pas : corr_x vers le haut, le plus sur COLJ20, POUJ19, POUJ20 et POUH19, et corr_y vers le haut sur COLH19, COLH20, COLJ23 et COLJ24 ; le saut ne revient pas, ce n'est pas un mouvement. La compensation tourne ensuite sur les deux seules références REFH22 et REFP''21 (les corrections de ces deux références s'annulent) : une base plus fragile, qui ne compense plus bien le mouvement de la caméra et fait bouger toutes les cibles au moindre écart d'une référence. Très mauvais signe pour la mesure : vérifier le prisme de REFCOLH22 sur place et le remettre en état.", "revue": "2026-11-04"}
{"id": "NEBRASKA-3", "debut": "2026-10-13T04:00Z", "fin": "2026-10-17T04:00Z", "categorie": "Displacement", "description": "Bosse lente du corr_y des cibles du haut (COLJ20, POUJ20, POUJ19, COLJ19, et un peu COLH19 et POUH19) : il monte d'un cran le 13 octobre au matin, reste haut, puis redescend le 17 octobre au matin ; le corr_x de COLJ20 et POUJ20 recule un peu en même temps. Au même moment la caméra revient en arrière : son tilt redescend de son pic du 12 octobre et son pan va à son plus bas du mois, puis repart le 17 octobre. La température du boîtier de la caméra remonte un peu au début puis reste stable : lien non établi. D'après l'expert, BREITHORN, MICHIGAN et NEBRASKA sont dans le même bâtiment : les caméras de BREITHORN et de MICHIGAN s'arrêtent et reculent aux mêmes jours. Déduite des courbes et de la pose : c'est la caméra qui bouge, mal compensée avec deux références, et la scène se déforme avec elle : POUH20 redescend avec elle. Pour le client : la caméra se redresse et la scène se déforme avec elle : un mouvement de l'ouvrage n'est pas établi ; l'inclinaison de la caméra est à surveiller, et rétablir une troisième référence rendra les courbes de nouveau fiables.", "revue": "2026-11-04"}
{"id": "NEBRASKA-4", "debut": "2026-10-15T20:00Z", "fin": "2026-10-16T12:00Z", "categorie": "No data", "description": "Aucune mesure pour aucun capteur pendant trois mesures, la nuit du 15 au 16 octobre : toutes les courbes manquent, puis reprennent au même niveau qu'avant le trou. Les métriques de la station (tension, températures) manquent aussi sur la même plage ; la tension est normale juste avant et juste après, ce n'est donc pas un manque d'énergie. Le même trou touche les deux autres stations du bâtiment (BREITHORN, MICHIGAN, dans le même bâtiment d'après l'expert), mais aussi toutes les autres stations. Le trou commence à la même heure, vers 23:00, sur les neuf stations qui mesuraient alors (LENZSPITZE n'a ses premières mesures qu'au milieu de cette nuit, WILDSTRUBEL est déjà arrêtée), et leurs métriques s'arrêtent en même temps sur la plupart ; mesures et métriques reprennent à des heures différentes selon la station, la plupart en fin de matinée. JUNGFRAU, dont les métriques continuent, accumule toute la nuit des entrées non envoyées, parties en fin de matinée, et ses mesures de la nuit manquent pourtant aux données : une cause commune hors des stations (transmission ou réception des données), pas une coupure des stations ; elle n'est pas établie. La cause n'est donc pas propre au bâtiment. Les courbes manquent sur la plage ; rien à faire sur la station si cela ne se répète pas.", "revue": "2026-11-04"}
{"id": "NEBRASKA-5", "debut": "2026-10-16T20:00Z", "fin": "2026-10-17T20:00Z", "categorie": "Displacement", "description": "Le corr_x de COLJ19 saute seul vers le haut à la mesure de minuit le 17 octobre, reste haut toute la journée, puis revient en partie le soir ; ses voisines ne sautent pas. Sa position brute dans l'image se décale d'autant par rapport aux autres cibles, sans que la caméra bouge à cet instant ni que son error_value change ; rien sur les vignettes. Ce n'est pas un effet de la compensation ; cause non établie, déduite des courbes et des positions brutes. À vérifier : regarder la cible et surveiller sa courbe.", "revue": "2026-11-04"}
{"id": "NEBRASKA-6", "debut": "2026-10-16T20:00Z", "fin": "2026-11-01T00:00Z", "categorie": "Displacement", "description": "Longue dérive du corr_x de toutes les cibles vers le haut, la plus forte sur les cibles du haut et de la droite de l'image (COLJ20, POUJ20, POUJ19, COLJ19, puis COLH19, POUH19, COLH20) et faible sur celles proches des références (COLH21, COLJ23, COLJ24) ; le corr_y de COLH19, POUH19, POUJ20, COLJ19 et COLH20 descend, celui de POUH20 et de COLH21 monte ; pas de retour à la fin du mois. La caméra continue de piquer du nez comme dans la première quinzaine (tilt qui monte, pan et rotation qui tournent, échelle qui baisse), et la compensation sur deux références seulement le rend mal, si bien que les cibles dérivent avec elle. La température du boîtier de la caméra baisse à partir du 16 octobre et la dérive en suit les à-coups : montée rapide jusqu'au 19 octobre, plus lente jusqu'au 24 octobre, arrêt et léger recul quand la température remonte du 25 au 28 octobre, nouvelle montée avec le froid des 28 et 29 octobre, léger recul quand elle remonte le 31 octobre. Mais la caméra piquait déjà du nez du 3 au 12 octobre quand la température baissait à peine, et elle reste plus inclinée en fin de mois qu'au milieu à température égale : la température ne l'explique pas seule, lien non établi. D'après l'expert, BREITHORN, MICHIGAN et NEBRASKA sont dans le même bâtiment : les caméras des trois stations s'inclinent ensemble, dans le même sens et aux mêmes dates (avancée jusqu'au 12 octobre, arrêt et léger recul du 13 au 16, reprise du 17 à la fin du mois), ce qui désigne une cause commune au bâtiment plutôt qu'un défaut de cette seule caméra. Vérifié cible par cible (ensemble.py --rigide, et une transformation de caméra ajustée sur les autres cibles) : la scène ne bouge pas tout à fait d'un bloc, elle se déforme pendant que la caméra s'incline. POUH20 s'écarte le plus des autres cibles, sa voisine POUH21 presque pas ; puis COLH21, et les cibles des bords de l'image (COLJ19, COLJ20, COLH19) ; d'où la montée du corr_y de POUH20 et de COLH21. Ces écarts suivent l'inclinaison de la caméra dans les deux sens : POUH20 monte avec elle les 11 et 12 octobre, redescend quand elle se redresse du 13 au 16 octobre, monte vite avec elle du 17 au 19 octobre, puis lentement jusqu'à la fin du mois ; COLH21 ne s'écarte qu'à partir du 18 octobre, quand la caméra dépasse son inclinaison du 12. C'est le même mouvement que celui de la caméra, pas un événement à part ; à inclinaison égale, POUH20 reste un peu plus haute après le 17 octobre qu'avant. Cause non établie (la caméra qui se déplace un peu en s'inclinant, des cibles à des distances différentes, ou un mouvement de l'ouvrage avec le bâtiment). Déduite des courbes, des positions brutes, de la pose et des températures ; images sans rien de net. Pour le client : la caméra s'incline et la scène se déforme avec elle : un mouvement de l'ouvrage n'est pas établi ; à surveiller, l'inclinaison de la caméra et les courbes de POUH20 et de COLH21, qui s'écartent le plus ; rétablir une troisième référence rendra les courbes de nouveau fiables.", "revue": "2026-11-04"}
{"id": "NEBRASKA-7", "debut": "2026-10-18T16:00Z", "fin": "2026-10-19T16:00Z", "categorie": "Thermal displacement", "description": "Matin frais du 19 octobre, le plus froid du mois jusque-là pour le boîtier de la caméra : le corr_y de POUJ19, COLJ20 et POUH20 monte du soir du 18 jusqu'à midi, puis revient ; le corr_x de presque toutes les cibles fait un pic à la mesure de 08:00 (COLH19, COLH20, COLH21, POUH19, COLJ20). La caméra pique du nez dans la nuit, le plus à 08:00, où son pan bouge et son échelle baisse aussi, puis tout revient. Aucune référence mal vue. Déduite des courbes, de la pose et des températures : un bref mouvement de la caméra avec le froid, mal compensé par la base de deux références, comme les matins froids de la fin du mois. Les cibles ne bougent pas : rien à faire, ne pas croire ces points.", "revue": "2026-11-04"}
{"id": "NEBRASKA-8", "debut": "2026-10-26T00:00Z", "fin": "2026-10-26T20:00Z", "categorie": "Thermal displacement", "description": "Matin frais du 26 octobre : de 04:00 à 16:00, le corr_y des cibles du haut monte (POUJ19, COLJ20, COLJ19, POUJ20 surtout), puis revient le soir ; le corr_x ne bouge guère. La caméra pique du nez et tourne au même moment, au creux de la température du boîtier de la caméra, lu dans les métriques, puis revient en partie. Rien devant les cibles sur l'image de 08:00. D'après l'expert, BREITHORN, MICHIGAN et NEBRASKA sont dans le même bâtiment : les caméras de BREITHORN et de MICHIGAN bougent le même matin, au même refroidissement. Déduite des courbes, de la pose et des températures : un bref mouvement de la caméra avec le froid, mal compensé par la base de deux références. Les cibles ne bougent pas : rien à faire, ne pas croire ces points.", "revue": "2026-11-04"}
{"id": "NEBRASKA-9", "debut": "2026-10-27T20:00Z", "fin": "2026-10-28T16:00Z", "categorie": "Thermal displacement", "description": "Matin frais du 28 octobre : de minuit à midi, le corr_y de la plupart des cibles descend (COLH19, POUH19, POUJ20, COLJ20, COLH20 surtout), puis revient l'après-midi ; le corr_x de presque toutes les cibles fait un pic à la mesure de 08:00 (COLJ19, COLJ20, POUJ19, POUH20, POUH21). La caméra bouge en même temps, à l'heure la plus froide de la matinée pour son boîtier : son pan et sa rotation s'écartent à 04:00, elle pique du nez et son échelle baisse à 08:00, puis tout revient à midi ; aucune référence mal vue, rien sur les images. Déduite des courbes, de la pose et des températures : un bref mouvement de la caméra avec le froid, mal compensé par la base de deux références. Les cibles ne bougent pas : rien à faire, ne pas croire ces points.", "revue": "2026-11-04"}
{"id": "NEBRASKA-10", "debut": "2026-10-28T20:00Z", "fin": "2026-10-29T12:00Z", "categorie": "Thermal displacement", "description": "Nuit la plus froide du mois pour le boîtier de la caméra, du 28 au 29 octobre : de minuit au matin, la caméra pique du nez, son pan, sa rotation et son échelle s'écartent, le plus à 04:00, puis tout revient à midi. Le corr_x de presque toutes les cibles monte sur ces mesures, en pic à 04:00 ; le corr_y de la plupart saute vers le haut à 04:00 (COLJ20, POUJ19, COLH19, POUH19, COLH20 surtout), encadré de mesures plus basses à 00:00 et 08:00. À 04:00, les deux références restantes bougent un peu l'une par rapport à l'autre dans l'image, ce que la base de deux références traduit en une rotation de toute la scène ; l'error_value de REFH22, COLH19 et COLH20 monte aussi, loin du seuil, sans rejet. Vignettes de REFH22, REFP''21 et COLH20 sans rien de net, taches inchangées. Déduite des courbes, de la pose et des températures : effet thermique sur la caméra ; la cause de la hausse de l'error_value n'est pas établie. Pas un mouvement de l'ouvrage : rien à faire, ne pas croire les courbes sur ces mesures.", "revue": "2026-11-04"}
{"id": "NEBRASKA-11", "debut": "2026-10-29T20:00Z", "fin": "2026-10-30T16:00Z", "categorie": "Thermal displacement", "description": "Même chose la nuit froide suivante, du 29 au 30 octobre : la caméra pique du nez, sa rotation et son échelle s'écartent, le plus à 04:00, puis reviennent dans l'après-midi. Le corr_x des cibles est plus haut de minuit à midi ; le corr_y de la plupart saute vers le haut à 04:00 (COLJ20, POUJ19, POUH20, POUJ20 surtout), puis vers le bas à 08:00. L'error_value de REFH22 et de COLH20 monte à son plus haut du mois à 04:00, celle de COLH19 aussi, loin du seuil, sans rejet. Vignettes de 04:00 sans rien de net, taches inchangées. Déduite des courbes, de la pose et des températures : effet thermique sur la caméra, mal compensé par la base de deux références ; la cause de la hausse de l'error_value n'est pas établie. Pas un mouvement : ne pas croire les courbes sur ces mesures.", "revue": "2026-11-04"}
{"id": "NEBRASKA-1", "start": "2026-10-03T00:00Z", "end": "2026-10-12T12:00Z", "family": "Displacement", "description": "From the start of the measurements, on 3 October, the corr_x of the targets at the top and the right of the image (COLJ20, POUJ20, POUJ19, COLJ19, then POUH19 and COLH19) rises slowly, without returning, until 12 October around noon; those at the bottom, near the references, hardly move. At the same time, the camera gradually nods forward: its tilt rises, its rotation turns and its scale drops, with a clearer step from the afternoon of 7 October to 8 October, which the compensation absorbs as long as the three references hold (no step on the curves that day). The rise of the targets is weak with three references and clearer after the loss of REFCOLH22 on 9 October (the jump of that day is another label). The raw positions of the targets move mostly with the camera: it is the compensation that renders this movement poorly. The camera housing temperature only drops a little over the phase. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of the three stations tilt together, in the same direction and on the same dates (advance until 12 October, stop and slight backward movement from 13 to 16, resumption from the 17th to the end of the month), which points to a cause common to the building rather than a fault of this camera alone; at equal housing temperature, the cameras are more tilted at the end of the month than in the middle: temperature does not explain it alone, link not established. Deduced from the curves and the camera pose. For the customer: the camera tilts and the scene deforms with it: a movement of the structure is not established; the camera tilt is to be monitored, and restoring a third reference will make the curves reliable again.", "review": "2026-11-04"}
{"id": "NEBRASKA-2", "start": "2026-10-09T08:00Z", "end": "2026-11-01T00:00Z", "family": "Target issue", "description": "The reference REFCOLH22 is lost at the 9 October noon measurement and does not come back until the end of the month: its error_value jumps almost to the maximum and all its measurements are rejected. On the thumbnails, its spot, sharp and round until the morning of 9 October, has disappeared from its place at the next measurement, while the neighboring spot and the other references are intact; what made it disappear (prism fallen, removed, hidden) is not visible on the whole image. At the same measurement, MICHIGAN, in the same building as NEBRASKA according to the expert, also loses one of its references (REFPOU22), whose spot disappears in the same way with no visible obstacle: a cause common to both, in the building, is to be looked for; it is not established. At the loss, all the targets jump together in one step: corr_x upward, most on COLJ20, POUJ19, POUJ20 and POUH19, and corr_y upward on COLH19, COLH20, COLJ23 and COLJ24; the jump does not return, it is not a movement. The compensation then runs on the two only references REFH22 and REFP''21 (the corrections of these two references cancel): a more fragile basis, which no longer compensates the camera movement well and makes all the targets move at the slightest deviation of a reference. Very bad sign for the measurement: check the prism of REFCOLH22 on site and restore it.", "review": "2026-11-04"}
{"id": "NEBRASKA-3", "start": "2026-10-13T04:00Z", "end": "2026-10-17T04:00Z", "family": "Displacement", "description": "Slow bump of the corr_y of the top targets (COLJ20, POUJ20, POUJ19, COLJ19, and a little COLH19 and POUH19): it rises by a notch on 13 October in the morning, stays high, then goes back down on 17 October in the morning; the corr_x of COLJ20 and POUJ20 recedes a little at the same time. At the same moment the camera goes back: its tilt goes back down from its peak of 12 October and its pan goes to its lowest of the month, then goes up again on 17 October. The camera housing temperature rises a little at the start then stays stable: link not established. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of BREITHORN and MICHIGAN stop and move back on the same days. Deduced from the curves and the pose: it is the camera that moves, poorly compensated with two references, and the scene deforms with it: POUH20 goes back down with it. For the customer: the camera straightens and the scene deforms with it: a movement of the structure is not established; the camera tilt is to be monitored, and restoring a third reference will make the curves reliable again.", "review": "2026-11-04"}
{"id": "NEBRASKA-4", "start": "2026-10-15T20:00Z", "end": "2026-10-16T12:00Z", "family": "No data", "description": "No measurement for any sensor for three measurements, in the night of 15 to 16 October: all the curves are missing, then resume at the same level as before the gap. The station metrics (voltage, temperatures) are also missing over the same range; the voltage is normal just before and just after, so it is not a lack of energy. The same gap affects the two other stations of the building (BREITHORN, MICHIGAN, in the same building according to the expert), but also all the other stations. The gap starts at the same time, around 23:00, on the nine stations that were measuring then (LENZSPITZE only has its first measurements in the middle of that night, WILDSTRUBEL is already stopped), and their metrics stop at the same time on most of them; measurements and metrics resume at different times depending on the station, most of them in late morning. JUNGFRAU, whose metrics continue, accumulates unsent entries all night, sent in late morning, and yet its measurements for the night are missing from the data: a common cause outside the stations (transmission or reception of the data), not a shutdown of the stations; it is not established. The cause is therefore not specific to the building. The curves are missing over the range; nothing to do on the station if it does not repeat.", "review": "2026-11-04"}
{"id": "NEBRASKA-5", "start": "2026-10-16T20:00Z", "end": "2026-10-17T20:00Z", "family": "Displacement", "description": "The corr_x of COLJ19 alone jumps upward at the midnight measurement on 17 October, stays high all day, then partly returns in the evening; its neighbors do not jump. Its raw position in the image shifts by as much relative to the other targets, without the camera moving at that moment or its error_value changing; nothing on the thumbnails. It is not an effect of the compensation; cause not established, deduced from the curves and the raw positions. To be checked: look at the target and monitor its curve.", "review": "2026-11-04"}
{"id": "NEBRASKA-6", "start": "2026-10-16T20:00Z", "end": "2026-11-01T00:00Z", "family": "Displacement", "description": "Long upward drift of the corr_x of all the targets, strongest on the targets at the top and the right of the image (COLJ20, POUJ20, POUJ19, COLJ19, then COLH19, POUH19, COLH20) and weak on those close to the references (COLH21, COLJ23, COLJ24); the corr_y of COLH19, POUH19, POUJ20, COLJ19 and COLH20 goes down, that of POUH20 and COLH21 rises; no return at the end of the month. The camera keeps nodding forward as in the first half of the month (tilt rising, pan and rotation turning, scale dropping), and the compensation on two references only renders it poorly, so that the targets drift with it. The camera housing temperature drops from 16 October and the drift follows its jolts: fast rise until 19 October, slower until 24 October, stop and slight backward movement when the temperature rises again from 25 to 28 October, new rise with the cold of 28 and 29 October, slight backward movement when it rises again on 31 October. But the camera was already nodding forward from 3 to 12 October when the temperature was hardly dropping, and it stays more tilted at the end of the month than in the middle at equal temperature: temperature does not explain it alone, link not established. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of the three stations tilt together, in the same direction and on the same dates (advance until 12 October, stop and slight backward movement from 13 to 16, resumption from the 17th to the end of the month), which points to a cause common to the building rather than a fault of this camera alone. Checked target by target (ensemble.py --rigide, and a camera transformation fitted on the other targets): the scene does not move quite as a block, it deforms while the camera tilts. POUH20 moves away the most from the other targets, its neighbor POUH21 hardly at all; then COLH21, and the targets at the edges of the image (COLJ19, COLJ20, COLH19); hence the rise of the corr_y of POUH20 and COLH21. These deviations follow the camera tilt in both directions: POUH20 rises with it on 11 and 12 October, goes back down when it straightens from 13 to 16 October, rises fast with it from 17 to 19 October, then slowly until the end of the month; COLH21 only moves away from 18 October, when the camera exceeds its tilt of the 12th. It is the same movement as that of the camera, not a separate event; at equal tilt, POUH20 stays slightly higher after 17 October than before. Cause not established (the camera moving slightly as it tilts, targets at different distances, or a movement of the structure with the building). Deduced from the curves, the raw positions, the pose and the temperatures; images with nothing clear. For the customer: the camera tilts and the scene deforms with it: a movement of the structure is not established; to be monitored, the camera tilt and the curves of POUH20 and COLH21, which move away the most; restoring a third reference will make the curves reliable again.", "review": "2026-11-04"}
{"id": "NEBRASKA-7", "start": "2026-10-18T16:00Z", "end": "2026-10-19T16:00Z", "family": "Thermal displacement", "description": "Cool morning of 19 October, the coldest of the month so far for the camera housing: the corr_y of POUJ19, COLJ20 and POUH20 rises from the evening of the 18th until noon, then returns; the corr_x of almost all the targets makes a peak at the 08:00 measurement (COLH19, COLH20, COLH21, POUH19, COLJ20). The camera nods forward during the night, most at 08:00, where its pan moves and its scale drops too, then everything returns. No reference poorly seen. Deduced from the curves, the pose and the temperatures: a brief camera movement with the cold, poorly compensated by the two-reference basis, like the cold mornings at the end of the month. The targets do not move: nothing to do, do not trust these points.", "review": "2026-11-04"}
{"id": "NEBRASKA-8", "start": "2026-10-26T00:00Z", "end": "2026-10-26T20:00Z", "family": "Thermal displacement", "description": "Cool morning of 26 October: from 04:00 to 16:00, the corr_y of the top targets rises (POUJ19, COLJ20, COLJ19, POUJ20 above all), then returns in the evening; the corr_x hardly moves. The camera nods forward and rotates at the same moment, at the trough of the camera housing temperature, read in the metrics, then partly returns. Nothing in front of the targets on the 08:00 image. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of BREITHORN and MICHIGAN move the same morning, at the same cooling. Deduced from the curves, the pose and the temperatures: a brief camera movement with the cold, poorly compensated by the two-reference basis. The targets do not move: nothing to do, do not trust these points.", "review": "2026-11-04"}
{"id": "NEBRASKA-9", "start": "2026-10-27T20:00Z", "end": "2026-10-28T16:00Z", "family": "Thermal displacement", "description": "Cool morning of 28 October: from midnight to noon, the corr_y of most targets goes down (COLH19, POUH19, POUJ20, COLJ20, COLH20 above all), then returns in the afternoon; the corr_x of almost all the targets makes a peak at the 08:00 measurement (COLJ19, COLJ20, POUJ19, POUH20, POUH21). The camera moves at the same time, at the coldest hour of the morning for its housing: its pan and rotation move away at 04:00, it nods forward and its scale drops at 08:00, then everything returns at noon; no reference poorly seen, nothing on the images. Deduced from the curves, the pose and the temperatures: a brief camera movement with the cold, poorly compensated by the two-reference basis. The targets do not move: nothing to do, do not trust these points.", "review": "2026-11-04"}
{"id": "NEBRASKA-10", "start": "2026-10-28T20:00Z", "end": "2026-10-29T12:00Z", "family": "Thermal displacement", "description": "Coldest night of the month for the camera housing, from 28 to 29 October: from midnight to morning, the camera nods forward, its pan, rotation and scale move away, most at 04:00, then everything returns at noon. The corr_x of almost all the targets rises over these measurements, peaking at 04:00; the corr_y of most jumps upward at 04:00 (COLJ20, POUJ19, COLH19, POUH19, COLH20 above all), framed by lower measurements at 00:00 and 08:00. At 04:00, the two remaining references move slightly relative to each other in the image, which the two-reference basis translates into a rotation of the whole scene; the error_value of REFH22, COLH19 and COLH20 also rises, far from the threshold, without rejection. Thumbnails of REFH22, REFP''21 and COLH20 with nothing clear, spots unchanged. Deduced from the curves, the pose and the temperatures: thermal effect on the camera; the cause of the rise in error_value is not established. Not a movement of the structure: nothing to do, do not trust the curves over these measurements.", "review": "2026-11-04"}
{"id": "NEBRASKA-11", "start": "2026-10-29T20:00Z", "end": "2026-10-30T16:00Z", "family": "Thermal displacement", "description": "Same thing on the following cold night, from 29 to 30 October: the camera nods forward, its rotation and scale move away, most at 04:00, then return in the afternoon. The corr_x of the targets is higher from midnight to noon; the corr_y of most jumps upward at 04:00 (COLJ20, POUJ19, POUH20, POUJ20 above all), then downward at 08:00. The error_value of REFH22 and COLH20 rises to its highest of the month at 04:00, that of COLH19 too, far from the threshold, without rejection. 04:00 thumbnails with nothing clear, spots unchanged. Deduced from the curves, the pose and the temperatures: thermal effect on the camera, poorly compensated by the two-reference basis; the cause of the rise in error_value is not established. Not a movement: do not trust the curves over these measurements.", "review": "2026-11-04"}