{"id": "NIEDERHORN-1", "debut": "2026-10-01T00:00Z", "fin": "2026-10-01T02:00Z", "categorie": "No data", "description": "Une mesure manque pour tous les capteurs, références et cibles : un point absent sur toutes les courbes. La station tourne (métriques présentes à cette heure, tension normale avant et après) ; la cause du manque n'est pas établie (mesure non faite ou non transmise). Les courbes reprennent à la mesure suivante sans saut : rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-2", "debut": "2026-10-01T00:00Z", "fin": "2026-11-01T00:00Z", "categorie": "Target issue", "description": "La cible e03 est rejetée à presque toutes les mesures du lot : sa courbe corrigée n'existe pas (quelques points isolés au plus). Vu sur les vignettes : aucune tache n'est visible à sa position sur les vignettes, de jour comme de nuit. Ce n'est pas la météo : c'est permanent, de jour comme de nuit. Intervenir sur la cible ou sur sa configuration ; ignorer sa courbe.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-3", "debut": "2026-10-01T00:00Z", "fin": "2026-11-01T00:00Z", "categorie": "Target issue", "description": "La cible e04 est rejetée à presque toutes les mesures du lot : sa courbe corrigée n'existe pas (quelques points isolés au plus). Vu sur les vignettes : aucune tache nette n'est visible à sa position sur les vignettes, seulement une petite lueur de jour. Ce n'est pas la météo : c'est permanent, de jour comme de nuit. Intervenir sur la cible ou sur sa configuration ; ignorer sa courbe.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-4", "debut": "2026-10-01T00:00Z", "fin": "2026-11-01T00:00Z", "categorie": "Target issue", "description": "La cible e05 est rejetée à presque toutes les mesures du lot : sa courbe corrigée n'existe pas (quelques points isolés au plus). Vu sur les vignettes : aucune tache n'est visible à sa position sur les vignettes, de jour comme de nuit. Ce n'est pas la météo : c'est permanent, de jour comme de nuit. Intervenir sur la cible ou sur sa configuration ; ignorer sa courbe.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-5", "debut": "2026-10-01T00:00Z", "fin": "2026-11-01T00:00Z", "categorie": "Target issue", "description": "La cible e07 est rejetée à presque toutes les mesures du lot : sa courbe corrigée n'existe pas (quelques points isolés au plus). Vu sur les vignettes : sa tache est visible mais entre deux voisines très proches ; son erreur de reconnaissance reste au-dessus du seuil. Ce n'est pas la météo : c'est permanent, de jour comme de nuit. Intervenir sur la cible ou sur sa configuration ; ignorer sa courbe.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-6", "debut": "2026-10-01T00:00Z", "fin": "2026-11-01T00:00Z", "categorie": "Target issue", "description": "La cible e08 est rejetée à presque toutes les mesures du lot : sa courbe corrigée n'existe pas (quelques points isolés au plus). Vu sur les vignettes : sa tache est visible mais entre deux voisines très proches ; son erreur de reconnaissance reste au-dessus du seuil. Ce n'est pas la météo : c'est permanent, de jour comme de nuit. Intervenir sur la cible ou sur sa configuration ; ignorer sa courbe.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-7", "debut": "2026-10-01T00:00Z", "fin": "2026-11-01T00:00Z", "categorie": "Target issue", "description": "La cible e11 est rejetée à presque toutes les mesures du lot : sa courbe corrigée n'existe pas (quelques points isolés au plus). Vu sur les vignettes : sa tache est très grosse et éblouie la nuit, collée à une petite voisine ; son erreur reste au-dessus du seuil. Ce n'est pas la météo : c'est permanent, de jour comme de nuit. Intervenir sur la cible ou sur sa configuration ; ignorer sa courbe.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-8", "debut": "2026-10-01T00:00Z", "fin": "2026-11-01T00:00Z", "categorie": "Target issue", "description": "La cible e12 est rejetée à presque toutes les mesures du lot : sa courbe corrigée n'existe pas (quelques points isolés au plus). Vu sur les vignettes : sa tache est très grosse et éblouie la nuit, collée à une petite voisine ; son erreur reste au-dessus du seuil. Ce n'est pas la météo : c'est permanent, de jour comme de nuit. Intervenir sur la cible ou sur sa configuration ; ignorer sa courbe.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-9", "debut": "2026-10-01T00:00Z", "fin": "2026-11-01T00:00Z", "categorie": "Target issue", "description": "PWD_RMP_B15_017_C09 est rejetée presque chaque nuit, du soir au matin, jusqu'au 24.10 (sauf du 12 au 14), puis seulement quelques heures les nuits du 25 et du 27.10, et une dernière mesure le 28.10 à 00:00 UTC ; jusque-là sa courbe corrigée manque chaque nuit. Ensuite elle est gardée la nuit aussi, mais ses points de jour restent, jusqu'à la fin du lot, plus dispersés que ceux de ses voisines et changent de niveau d'un jour à l'autre. Vu sur les vignettes : la nuit, sous le projecteur, sa tache est saturée et étalée en croix, alors que de jour elle est petite et nette ; les voisines du même genre restent sous le seuil. Les rejets reviennent chaque nuit, quel que soit le temps : un problème de la cible (trop brillante sous l'éclairage), pas un mouvement. Vérifier son orientation ou l'éclairage ; ignorer sa courbe.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-10", "debut": "2026-10-01T00:00Z", "fin": "2026-11-01T00:00Z", "categorie": "Target issue", "description": "e01 est rejetée presque chaque jour, du milieu de la matinée au soir, et mesurée la nuit : sa courbe corrigée manque chaque jour et, juste sous le seuil, ses points montent nettement dans l'après-midi. Vu sur les vignettes : de jour, sa tache au bord gauche de l'image, dans le vignettage, est presque fondue dans le fond ; la nuit elle est nette. Revient chaque jour, quel que soit le temps : la cible est trop peu contrastée de jour. Ignorer sa courbe de jour ; voir si elle peut être mieux placée ou éclairée.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-11", "debut": "2026-10-01T00:00Z", "fin": "2026-11-01T00:00Z", "categorie": "Target issue", "description": "PWD_IMP_B08_024_C09 est rejetée la plupart des journées de la première quinzaine, de la fin de matinée au soir, puis plus rarement : sa courbe corrigée manque ces heures-là. Son erreur de reconnaissance tourne juste au-dessus de son seuil de jour, sous lui la nuit ; sur les vignettes la tache est nette, sur un fond de ballast éclairé, sans obstacle. Cause non établie (cible à la limite de son seuil de jour). Ignorer sa courbe de jour ; revoir son seuil ou la cible.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-12", "debut": "2026-10-01T04:00Z", "fin": "2026-10-01T16:00Z", "categorie": "Visibility", "description": "La nuit et au matin, plusieurs heures : l'erreur de reconnaissance de nombreuses cibles monte, beaucoup sont rejetées par moments (surtout PWD_IMP_B07_017_C09, PWD_RMP_B12_017_C09, PWD_RMP_B12_018_C09, PWD_RMP_B15_018_C09, PWD_RMP_B15_019_C09, e06, e09, et les cibles de gauche) et les autres s'agitent ; les références tiennent, plus haut sur la route. Retour progressif en fin de matinée. Cause probable : pluie ou brume (d'après l'expert, une nuit de pluie à cette station ; taches plus faibles sur les vignettes de 07:00). L'ouvrage ne bouge pas : ne pas croire les courbes sur la plage.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-13", "debut": "2026-10-01T11:00Z", "fin": "2026-10-01T14:00Z", "categorie": "Obstruction", "description": "Une seule mesure : e02, e06, e09, e10, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_025_C09, e14, e15, PWD_RMP_B15_020_C09, PWD_IMP_B07_018_C09, PWD_RMP_B15_019_C09, PWD_RMP_B15_018_C09 sont rejetées et manquent sur les courbes corrigées ; les références restent intactes. Restées sous le seuil, PWD_RMP_B12_020_C09, PWD_RMP_B12_019_C09, PWD_RMP_B12_017_C09, PWD_IMP_B07_016_C09 font un saut d'une mesure sur corr_x ou corr_y, puis reviennent. Cause vue : un train de marchandises, numéros des wagons lisibles, sur l'image de 12:00. Tout revient à la mesure suivante : l'ouvrage ne bouge pas, point à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-14", "debut": "2026-10-01T12:00Z", "fin": "2026-10-01T14:00Z", "categorie": "No data", "description": "Une mesure manque pour tous les capteurs, références et cibles : un point absent sur toutes les courbes. La station tourne (métriques présentes à cette heure, tension normale avant et après) ; la cause du manque n'est pas établie (mesure non faite ou non transmise). Les courbes reprennent à la mesure suivante sans saut : rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-15", "debut": "2026-10-01T20:00Z", "fin": "2026-10-01T22:00Z", "categorie": "Obstruction", "description": "Une seule mesure : e02, e06, e09, PWD_RMP_B17_026_C09 sont rejetées et manquent sur les courbes corrigées ; les références restent intactes. Les autres cibles ne bougent pas. Cause vue : un train de voyageurs à deux étages, flou de mouvement, sur l'image de 21:00. Tout revient à la mesure suivante : l'ouvrage ne bouge pas, point à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-16", "debut": "2026-10-02T02:00Z", "fin": "2026-10-02T14:00Z", "categorie": "Visibility", "description": "La nuit et au matin, plusieurs heures : l'erreur de reconnaissance de nombreuses cibles monte, beaucoup sont rejetées par moments (surtout PWD_IMP_B07_017_C09, PWD_RMP_B12_017_C09, PWD_RMP_B12_018_C09, PWD_RMP_B15_018_C09, PWD_RMP_B15_019_C09, e06, e09, et les cibles de gauche) et les autres s'agitent ; les références tiennent, plus haut sur la route. Retour progressif en fin de matinée. Cause probable : pluie ou brume (d'après l'expert, une nuit de pluie à cette station, gouttes vues sur ses images). L'ouvrage ne bouge pas : ne pas croire les courbes sur la plage.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-17", "debut": "2026-10-02T07:00Z", "fin": "2026-10-03T02:00Z", "categorie": "Obstruction", "description": "PWD_IMP_B07_016_C09 seule, une bonne partie de la journée et le début de la nuit : son corr_x fait de grands pics, seule parmi toutes les cibles en début de matinée, puis sa mesure est rejetée par moments, ou, juste sous le seuil, son corr_x ou son corr_y s'écarte d'une mesure et revient ; ses voisines ne bougent pas en dehors de la nuit de pluie du matin. Cause vue sur les vignettes de 08:00, 09:00 et 10:00 : les feuilles de la plante du premier plan, poussées par le vent, touchent puis couvrent la tache de la cible. L'ouvrage ne bouge pas : ignorer la courbe de cette cible sur la plage.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-18", "debut": "2026-10-02T11:00Z", "fin": "2026-10-02T13:00Z", "categorie": "No data", "description": "Une mesure manque pour tous les capteurs, références et cibles : un point absent sur toutes les courbes. La station tourne (métriques présentes à cette heure, tension normale avant et après) ; la cause du manque n'est pas établie (mesure non faite ou non transmise). Les courbes reprennent à la mesure suivante sans saut : rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-19", "debut": "2026-10-02T13:00Z", "fin": "2026-10-02T23:00Z", "categorie": "Thermal displacement", "description": "Cycle thermique du jour (02/10). La température du boîtier monte fortement du matin jusqu'à 19:00, le plus vite entre 13:00 et 14:00, où elle gagne un peu. La pose de la caméra suit : le tilt monte un peu à 14:00 et revient à 19:00 ; le pan monte un peu jusqu'à 18:00 et redescend jusque vers 20:00 ; l'échelle monte nettement jusqu'à 19:00 et ne revient que lentement, dans la nuit. Ce jour, le cycle suit une matinée de pluie (NIEDERHORN#16) et il est plus faible : la température monte lentement, la pose bouge nettement moins que les jours de soleil et ne s'agite pas d'une mesure à l'autre ; les courbes sont comparées à la nuit du 03, celle du 02 étant une nuit de pluie. Les positions brutes de tous les capteurs, références comprises, bougent ensemble dans l'image ; la compensation suit mal : le corr_x de PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_RMP_B12_020_C09 et PWD_IMP_B07_017_C09 se creuse fortement, celui de PWD_RMP_B15_018_C09, e02 et e06 monte nettement ; le corr_y bouge en sens inverse, moins fort : il monte pour e10, PWD_IMP_B07_017_C09 et PWD_RMP_B12_017_C09, il baisse pour e14 et e02. Cause déduite : la caméra et son support bougent avec la température du boîtier (pose et température vont ensemble), les références fixes sur la route bougent avec les cibles dans l'image. Normal, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-20", "debut": "2026-10-02T20:00Z", "fin": "2026-10-02T22:00Z", "categorie": "Obstruction", "description": "Une seule mesure : e02, e06, e09, PWD_IMP_B07_016_C09 sont rejetées et manquent sur les courbes corrigées ; les références restent intactes. Restée sous le seuil, PWD_RMP_B17_026_C09 fait un saut d'une mesure sur corr_x ou corr_y, puis revient. Cause vue : un train de voyageurs à deux étages, flou de mouvement, sur la voie du fond, sur l'image de 21:00. Tout revient à la mesure suivante : l'ouvrage ne bouge pas, point à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-21", "debut": "2026-10-03T06:00Z", "fin": "2026-10-03T08:00Z", "categorie": "Obstruction", "description": "Une seule mesure, en pleine nuit : PWD_IMP_B07_016_C09 seule est rejetée et manque sur sa courbe corrigée, puis revient ; ses voisines ne bougent pas. Cause : la plante du premier plan, dont une feuille est tout près de la tache sur la vignette de 07:00. L'ouvrage ne bouge pas : ignorer la courbe de cette cible sur la plage.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-22", "debut": "2026-10-03T09:00Z", "fin": "2026-10-03T11:00Z", "categorie": "Obstruction", "description": "Une seule mesure, en pleine nuit : e02 seule est rejetée et manque sur sa courbe corrigée ; ses voisines et les références ne bougent pas. Sur la vignette de 10:00, la tache de e02 a disparu quand celle de e06, juste à côté, est intacte : quelque chose la cache ; rien de net sur l'image entière, cause non établie, même signature que les trains de la voie du fond qui cachent e02 seule. Retour à la mesure suivante : l'ouvrage ne bouge pas, point à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-23", "debut": "2026-10-03T12:00Z", "fin": "2026-10-03T14:00Z", "categorie": "Visibility", "description": "Au lever du soleil, sur quelques mesures, parfois une seule : l'erreur de reconnaissance des références PWD_REF08_C09 à PWD_REF11_C09 monte nettement, sans rejet ; la compensation en est un peu perturbée et le corr_x, corr_y de nombreuses cibles saute ou s'agite ; e06 et e09, à gauche, sont souvent rejetées. Cause vue sur l'image du 21.10 à 13:00 : le soleil levant entre dans le champ juste au-dessus de la route des références, avec halo et reflets sur toute l'image ; elle revient aux mêmes heures les jours clairs. L'ouvrage ne bouge pas : ne pas croire les courbes sur ces mesures.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-24", "debut": "2026-10-03T12:00Z", "fin": "2026-10-03T23:00Z", "categorie": "Thermal displacement", "description": "Cycle thermique du jour (03/10). La température du boîtier monte fortement du matin jusqu'à 15:00, le plus vite entre 12:00 et 13:00, où elle gagne nettement. La pose de la caméra suit : de 13:00 à 16:00, le tilt monte fortement et la rotation baisse fortement, puis tous deux reviennent d'un coup à 17:00 ; le pan monte fortement jusqu'à 17:00 et redescend jusque vers 19:00 ; l'échelle monte fortement jusqu'à 19:00 et ne revient que lentement, dans la nuit. Les positions brutes de tous les capteurs, références comprises, bougent ensemble dans l'image ; la compensation suit mal : le corr_x de PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B07_017_C09 et PWD_IMP_B08_025_C09 au centre et à droite se creuse fortement, celui de e02, e06, PWD_RMP_B17_026_C09 et e14 à gauche de l'image monte fortement ; le corr_y bouge en sens inverse, moins fort : il monte pour PWD_IMP_B07_017_C09, PWD_RMP_B12_017_C09 et PWD_RMP_B15_018_C09, il baisse pour PWD_RMP_B12_019_C09, e15 et e13. Les cibles ne bougent pas tout à fait d'un bloc : face au mouvement d'ensemble, le résidu de celles qui s'en écartent le plus, faible le matin, grandit fortement dans la journée. D'une mesure à l'autre, tant que le boîtier est chaud (13:00-22:00), la pose et les courbes s'agitent aussi : le pas d'une mesure à la suivante est bien plus grand que la nuit sur le pan, le tilt et la rotation, nettement plus grand sur le corr_x des cibles ; l'erreur de reconnaissance des cibles, elle, ne monte pas (elle baisse un peu). Les courbes retrouvent leur niveau de nuit vers 23:00. Cause déduite : la caméra et son support bougent avec la température du boîtier (pose et température vont ensemble), les références fixes sur la route bougent avec les cibles dans l'image. Normal, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-25", "debut": "2026-10-04T12:00Z", "fin": "2026-10-04T14:00Z", "categorie": "Visibility", "description": "Au lever du soleil, sur quelques mesures, parfois une seule : l'erreur de reconnaissance des références PWD_REF08_C09 à PWD_REF11_C09 monte nettement, sans rejet ; la compensation en est un peu perturbée et le corr_x, corr_y de nombreuses cibles saute ou s'agite ; e06 et e09, à gauche, sont souvent rejetées. Cause vue sur l'image du 21.10 à 13:00 : le soleil levant entre dans le champ juste au-dessus de la route des références, avec halo et reflets sur toute l'image ; elle revient aux mêmes heures les jours clairs. L'ouvrage ne bouge pas : ne pas croire les courbes sur ces mesures.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-26", "debut": "2026-10-04T12:00Z", "fin": "2026-10-05T00:00Z", "categorie": "Thermal displacement", "description": "Cycle thermique du jour (04/10). La température du boîtier monte fortement du matin jusqu'à 18:00, le plus vite entre 12:00 et 13:00, où elle gagne nettement. La pose de la caméra suit : le tilt baisse nettement à 19:00 et revient à 20:00 ; la rotation baisse nettement à 13:00 et revient à 18:00 ; le pan monte nettement jusqu'à 17:00 et redescend jusque vers 19:00 ; l'échelle monte fortement jusqu'à 19:00 et ne revient que lentement, dans la nuit. Les positions brutes de tous les capteurs, références comprises, bougent ensemble dans l'image ; la compensation suit mal : le corr_x de PWD_RMP_B12_018_C09 et PWD_IMP_B08_025_C09 au centre et à droite se creuse nettement, celui de e02, PWD_RMP_B17_026_C09, e06 et PWD_RMP_B15_018_C09 monte nettement ; le corr_y bouge en sens inverse, moins fort : il monte pour PWD_RMP_B15_018_C09, PWD_IMP_B07_017_C09 et PWD_RMP_B12_017_C09, il baisse pour e02, e10 et PWD_RMP_B12_019_C09. Les cibles ne bougent pas tout à fait d'un bloc : face au mouvement d'ensemble, le résidu de celles qui s'en écartent le plus, faible le matin, grandit fortement dans la journée. D'une mesure à l'autre, tant que le boîtier est chaud (13:00-22:00), la pose et les courbes s'agitent aussi : le pas d'une mesure à la suivante est bien plus grand que la nuit sur le pan, le tilt et la rotation, un peu plus grand sur le corr_x des cibles ; l'erreur de reconnaissance des cibles, elle, ne monte pas (elle baisse un peu). Les courbes retrouvent leur niveau de nuit vers 23:00. Cause déduite : la caméra et son support bougent avec la température du boîtier (pose et température vont ensemble), les références fixes sur la route bougent avec les cibles dans l'image. Normal, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-27", "debut": "2026-10-05T12:00Z", "fin": "2026-10-05T14:00Z", "categorie": "Visibility", "description": "Au lever du soleil, sur quelques mesures, parfois une seule : l'erreur de reconnaissance des références PWD_REF08_C09 à PWD_REF11_C09 monte nettement, sans rejet ; la compensation en est un peu perturbée et le corr_x, corr_y de nombreuses cibles saute ou s'agite ; e06 et e09, à gauche, sont souvent rejetées. Cause vue sur l'image du 21.10 à 13:00 : le soleil levant entre dans le champ juste au-dessus de la route des références, avec halo et reflets sur toute l'image ; elle revient aux mêmes heures les jours clairs. L'ouvrage ne bouge pas : ne pas croire les courbes sur ces mesures.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-28", "debut": "2026-10-05T12:00Z", "fin": "2026-10-05T23:00Z", "categorie": "Thermal displacement", "description": "Cycle thermique du jour (05/10). La température du boîtier monte fortement du matin jusqu'à 18:00, le plus vite entre 12:00 et 13:00, où elle gagne nettement. La pose de la caméra suit : de 13:00 à 16:00, le tilt monte fortement et la rotation baisse fortement, puis tous deux reviennent d'un coup à 17:00 ; le pan monte fortement jusqu'à 17:00 et redescend jusque vers 19:00 ; l'échelle monte nettement jusqu'à 19:00 puis revient dans la soirée. Les positions brutes de tous les capteurs, références comprises, bougent ensemble dans l'image ; la compensation suit mal : le corr_x de PWD_RMP_B12_018_C09, PWD_IMP_B07_018_C09, PWD_IMP_B07_017_C09 et PWD_RMP_B12_017_C09 au centre et à droite se creuse fortement, celui de e02, e06, PWD_RMP_B17_026_C09 et PWD_RMP_B15_018_C09 monte fortement ; le corr_y bouge en sens inverse, moins fort : il monte pour PWD_RMP_B12_017_C09, PWD_IMP_B07_017_C09 et PWD_RMP_B15_018_C09, il baisse pour e13, e02 et e15. Les cibles ne bougent pas tout à fait d'un bloc : face au mouvement d'ensemble, le résidu de celles qui s'en écartent le plus, faible le matin, grandit fortement dans la journée. D'une mesure à l'autre, tant que le boîtier est chaud (13:00-22:00), la pose et les courbes s'agitent aussi : le pas d'une mesure à la suivante est bien plus grand que la nuit sur le pan, le tilt et la rotation, bien plus grand sur le corr_x des cibles ; l'erreur de reconnaissance des cibles, elle, ne monte pas (elle baisse un peu). Les courbes retrouvent leur niveau de nuit vers 23:00. Cause déduite : la caméra et son support bougent avec la température du boîtier (pose et température vont ensemble), les références fixes sur la route bougent avec les cibles dans l'image. Normal, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-29", "debut": "2026-10-05T13:00Z", "fin": "2026-10-05T22:00Z", "categorie": "Obstruction", "description": "PWD_IMP_B07_016_C09 seule : par moments son erreur de reconnaissance saute presque au maximum et la mesure est rejetée, ou, juste sous le seuil, son corr_x ou son corr_y fait un pic d'une mesure, puis revient ; ses voisines ne bougent pas. Cause vue sur la vignette de 14:00 : les feuilles couvrent la tache, qui pâlit ; c'est la plante du premier plan, agitée par le vent, qui, d'après l'expert, passe devant cette cible. L'ouvrage ne bouge pas : ignorer la courbe de cette cible sur la plage.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-30", "debut": "2026-10-06T03:00Z", "fin": "2026-10-06T05:00Z", "categorie": "Obstruction", "description": "PWD_IMP_B07_016_C09 seule : par moments son erreur de reconnaissance saute presque au maximum et la mesure est rejetée, ou, juste sous le seuil, son corr_x ou son corr_y fait un pic d'une mesure, puis revient ; ses voisines ne bougent pas. Cause vue sur la vignette de 04:00 : les feuilles touchent la tache ; c'est la plante du premier plan, agitée par le vent, qui, d'après l'expert, passe devant cette cible. L'ouvrage ne bouge pas : ignorer la courbe de cette cible sur la plage.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-31", "debut": "2026-10-06T11:00Z", "fin": "2026-10-06T13:00Z", "categorie": "Obstruction", "description": "Une seule mesure : e02, e06, e09, e10, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_025_C09, e14, e15, PWD_RMP_B15_020_C09, PWD_IMP_B07_018_C09, PWD_RMP_B15_019_C09, PWD_RMP_B15_018_C09 sont rejetées et manquent sur les courbes corrigées ; les références restent intactes. Restées sous le seuil, e13, PWD_RMP_B12_020_C09, PWD_RMP_B12_018_C09, PWD_IMP_B07_017_C09, PWD_RMP_B12_017_C09 font un saut d'une mesure sur corr_x ou corr_y, puis reviennent. Cause vue : une bande sombre à bord droit qui barre la scène sur l'image de 12:00, un train dans la pénombre de l'aube. Tout revient à la mesure suivante : l'ouvrage ne bouge pas, point à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-32", "debut": "2026-10-06T12:00Z", "fin": "2026-10-06T14:00Z", "categorie": "Visibility", "description": "Au lever du soleil, juste après le train de la mesure d'avant : l'erreur de reconnaissance des références PWD_REF08_C09, PWD_REF09_C09 et PWD_REF10_C09 monte nettement, sans rejet, et le corr_x de e02, e06, e10 et PWD_IMP_B08_024_C09 s'écarte d'une mesure puis revient. Cause vue sur l'image de 13:00 : le soleil levant est dans le champ, au-dessus de la route des références, avec halo et reflets. L'ouvrage ne bouge pas : ne pas croire les courbes sur cette mesure.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-33", "debut": "2026-10-06T12:00Z", "fin": "2026-10-07T00:00Z", "categorie": "Thermal displacement", "description": "Cycle thermique du jour (06/10). La température du boîtier monte fortement du matin jusqu'à 20:00, le plus vite entre 13:00 et 14:00, où elle gagne fortement. La pose de la caméra suit : de 13:00 à 16:00, le tilt monte fortement et la rotation baisse fortement, puis tous deux reviennent d'un coup à 17:00 ; le pan monte fortement jusqu'à 17:00 et redescend jusque vers 19:00 ; l'échelle monte fortement jusqu'à 19:00 et ne revient que lentement, dans la nuit. Les positions brutes de tous les capteurs, références comprises, bougent ensemble dans l'image ; la compensation suit mal : le corr_x de PWD_RMP_B12_018_C09, PWD_IMP_B07_018_C09, PWD_IMP_B07_017_C09 et PWD_RMP_B12_017_C09 au centre et à droite se creuse fortement, celui de e02, e06, e10 et PWD_RMP_B17_026_C09 à gauche de l'image monte fortement ; le corr_y bouge en sens inverse, moins fort : il monte pour PWD_RMP_B12_017_C09, PWD_IMP_B07_017_C09 et PWD_RMP_B15_018_C09, il baisse pour e13, e09 et PWD_RMP_B12_019_C09. Les cibles ne bougent pas tout à fait d'un bloc : face au mouvement d'ensemble, le résidu de celles qui s'en écartent le plus, faible le matin, grandit fortement dans la journée. D'une mesure à l'autre, tant que le boîtier est chaud (13:00-22:00), la pose et les courbes s'agitent aussi : le pas d'une mesure à la suivante est bien plus grand que la nuit sur le pan, le tilt et la rotation, bien plus grand sur le corr_x des cibles ; l'erreur de reconnaissance des cibles, elle, ne monte pas (elle baisse un peu). Les courbes retrouvent leur niveau de nuit vers 23:00. Cause déduite : la caméra et son support bougent avec la température du boîtier (pose et température vont ensemble), les références fixes sur la route bougent avec les cibles dans l'image. Normal, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-34", "debut": "2026-10-06T21:00Z", "fin": "2026-10-06T23:00Z", "categorie": "Obstruction", "description": "Une seule mesure : e02, e06, e09, e10, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_025_C09, e14, e15, PWD_RMP_B15_020_C09, PWD_IMP_B07_018_C09, PWD_RMP_B15_019_C09, PWD_RMP_B15_018_C09, PWD_IMP_B07_017_C09, PWD_IMP_B07_016_C09 sont rejetées et manquent sur les courbes corrigées ; les références restent intactes. Restées sous le seuil, e13, PWD_RMP_B12_020_C09, PWD_RMP_B12_019_C09, PWD_RMP_B12_018_C09 font un saut d'une mesure sur corr_x ou corr_y, puis reviennent. Cause vue : un train de voyageurs à deux étages, flou de mouvement, sur l'image de 22:00. Tout revient à la mesure suivante : l'ouvrage ne bouge pas, point à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-35", "debut": "2026-10-06T22:00Z", "fin": "2026-10-07T00:00Z", "categorie": "Obstruction", "description": "PWD_IMP_B07_016_C09 seule : par moments son erreur de reconnaissance saute presque au maximum et la mesure est rejetée, ou, juste sous le seuil, son corr_x ou son corr_y fait un pic d'une mesure, puis revient ; ses voisines ne bougent pas. Cause vue sur la vignette de 23:00 : les feuilles couvrent la tache ; c'est la plante du premier plan, agitée par le vent, qui, d'après l'expert, passe devant cette cible. L'ouvrage ne bouge pas : ignorer la courbe de cette cible sur la plage.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-36", "debut": "2026-10-07T11:00Z", "fin": "2026-10-07T13:00Z", "categorie": "Obstruction", "description": "Une seule mesure : e02, e06, e09, e10, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_025_C09, e14, e15, PWD_RMP_B15_020_C09, PWD_RMP_B15_018_C09 sont rejetées et manquent sur les courbes corrigées ; les références restent intactes. Restées sous le seuil, PWD_RMP_B12_020_C09, PWD_RMP_B12_019_C09, PWD_IMP_B07_018_C09, PWD_RMP_B15_019_C09, PWD_RMP_B12_018_C09, PWD_RMP_B12_017_C09 font un saut d'une mesure sur corr_x ou corr_y, puis reviennent. Cause vue : une bande sombre qui barre les voies sur l'image de 12:00, un train dans la pénombre de l'aube. Tout revient à la mesure suivante : l'ouvrage ne bouge pas, point à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-37", "debut": "2026-10-07T13:00Z", "fin": "2026-10-07T18:00Z", "categorie": "Obstruction", "description": "PWD_IMP_B07_016_C09 seule : par moments son erreur de reconnaissance saute presque au maximum et la mesure est rejetée, ou, juste sous le seuil, son corr_x ou son corr_y fait un pic d'une mesure, puis revient ; ses voisines ne bougent pas. Cause vue sur la vignette de 14:00 : une feuille floue couvre la tache, qui ne se voit plus ; c'est la plante du premier plan, agitée par le vent, qui, d'après l'expert, passe devant cette cible. L'ouvrage ne bouge pas : ignorer la courbe de cette cible sur la plage.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-38", "debut": "2026-10-07T13:00Z", "fin": "2026-10-08T00:00Z", "categorie": "Thermal displacement", "description": "Cycle thermique du jour (07/10). La température du boîtier monte fortement du matin jusqu'à 19:00, le plus vite entre 15:00 et 16:00, où elle gagne un peu. La pose de la caméra suit : de 12:00 à 16:00, le tilt monte nettement et la rotation baisse nettement, puis tous deux reviennent d'un coup à 17:00 et 18:00 ; le pan monte nettement jusqu'à 17:00 et redescend jusque vers 19:00 ; l'échelle monte fortement jusqu'à 19:00 et ne revient que lentement, dans la nuit. Les positions brutes de tous les capteurs, références comprises, bougent ensemble dans l'image ; la compensation suit mal : le corr_x de PWD_RMP_B12_018_C09, PWD_IMP_B07_018_C09, PWD_IMP_B08_025_C09 et PWD_RMP_B12_017_C09 au centre et à droite se creuse fortement, celui de e06, e02, PWD_RMP_B17_026_C09 et PWD_RMP_B15_018_C09 monte nettement ; le corr_y bouge en sens inverse, moins fort : il monte pour PWD_IMP_B07_017_C09 et PWD_IMP_B08_025_C09, il baisse pour e10, e13 et PWD_RMP_B12_019_C09. Les cibles ne bougent pas tout à fait d'un bloc : face au mouvement d'ensemble, le résidu de celles qui s'en écartent le plus, faible le matin, grandit fortement dans la journée. D'une mesure à l'autre, tant que le boîtier est chaud (13:00-22:00), la pose et les courbes s'agitent aussi : le pas d'une mesure à la suivante est bien plus grand que la nuit sur le pan, le tilt et la rotation, bien plus grand sur le corr_x des cibles ; l'erreur de reconnaissance des cibles, elle, ne monte pas (elle baisse un peu). Les courbes retrouvent leur niveau de nuit vers 00:00. Cause déduite : la caméra et son support bougent avec la température du boîtier (pose et température vont ensemble), les références fixes sur la route bougent avec les cibles dans l'image. Normal, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-39", "debut": "2026-10-08T00:00Z", "fin": "2026-10-08T05:00Z", "categorie": "Visibility", "description": "La nuit, quelques heures : plusieurs cibles s'agitent, surtout PWD_RMP_B15_019_C09 et PWD_RMP_B15_020_C09 dont le corr_y et le corr_x s'écartent nettement, et e06, e09 et PWD_RMP_B16_026_C09 sont rejetées une fois chacune ; les références tiennent. Sur l'image de 02:00, le fond est plus bruité et les taches plus faibles que la nuit d'avant à la même heure, sans obstacle : cause probable, de la pluie ou de la brume, non établie. L'ouvrage ne bouge pas : ne pas croire les courbes sur la plage.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-40", "debut": "2026-10-08T01:00Z", "fin": "2026-10-08T07:00Z", "categorie": "Obstruction", "description": "PWD_IMP_B07_016_C09 seule : par moments son erreur de reconnaissance saute presque au maximum et la mesure est rejetée, ou, juste sous le seuil, son corr_x ou son corr_y fait un pic d'une mesure, puis revient ; ses voisines ne bougent pas. Cause vue sur la vignette de 05:00 : les feuilles couvrent la tache ; c'est la plante du premier plan, agitée par le vent, qui, d'après l'expert, passe devant cette cible. L'ouvrage ne bouge pas : ignorer la courbe de cette cible sur la plage.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-41", "debut": "2026-10-08T12:00Z", "fin": "2026-10-08T14:00Z", "categorie": "Visibility", "description": "Au lever du soleil, sur quelques mesures, parfois une seule : l'erreur de reconnaissance des références PWD_REF08_C09 à PWD_REF11_C09 monte nettement, sans rejet ; la compensation en est un peu perturbée et le corr_x, corr_y de nombreuses cibles saute ou s'agite ; e06 et e09, à gauche, sont souvent rejetées. Cause vue sur l'image du 21.10 à 13:00 : le soleil levant entre dans le champ juste au-dessus de la route des références, avec halo et reflets sur toute l'image ; elle revient aux mêmes heures les jours clairs. L'ouvrage ne bouge pas : ne pas croire les courbes sur ces mesures.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-42", "debut": "2026-10-08T12:00Z", "fin": "2026-10-08T23:00Z", "categorie": "Thermal displacement", "description": "Cycle thermique du jour (08/10). La température du boîtier monte fortement du matin jusqu'à 16:00, le plus vite entre 12:00 et 13:00, où elle gagne fortement. La pose de la caméra suit : de 13:00 à 15:00, le tilt monte fortement et la rotation baisse fortement, puis tous deux reviennent d'un coup à 17:00 ; le pan monte nettement jusqu'à 17:00 et redescend jusque vers 18:00 ; l'échelle monte fortement jusqu'à 17:00 puis revient dans la soirée. Les positions brutes de tous les capteurs, références comprises, bougent ensemble dans l'image ; la compensation suit mal : le corr_x de PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B08_025_C09 et PWD_IMP_B07_017_C09 au centre et à droite se creuse fortement, celui de e02, PWD_RMP_B15_018_C09, PWD_RMP_B15_019_C09 et PWD_RMP_B16_026_C09 monte nettement ; le corr_y bouge en sens inverse, moins fort : il monte pour PWD_RMP_B12_017_C09, PWD_IMP_B07_017_C09 et PWD_IMP_B08_025_C09, il baisse pour e13, e02 et e10. Les cibles ne bougent pas tout à fait d'un bloc : face au mouvement d'ensemble, le résidu de celles qui s'en écartent le plus, faible le matin, grandit fortement dans la journée. D'une mesure à l'autre, tant que le boîtier est chaud (13:00-22:00), la pose et les courbes s'agitent aussi : le pas d'une mesure à la suivante est nettement plus grand que la nuit sur le pan, le tilt et la rotation, nettement plus grand sur le corr_x des cibles ; l'erreur de reconnaissance des cibles, elle, ne monte pas (elle baisse un peu). Les courbes retrouvent leur niveau de nuit vers 23:00. Cause déduite : la caméra et son support bougent avec la température du boîtier (pose et température vont ensemble), les références fixes sur la route bougent avec les cibles dans l'image. Normal, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-43", "debut": "2026-10-08T16:00Z", "fin": "2026-10-08T18:00Z", "categorie": "Obstruction", "description": "Une seule mesure : PWD_RMP_B12_017_C09 est rejetée, et PWD_IMP_B07_016_C09 aussi ; leurs voisines tiennent. Cause vue sur la vignette de 17:00 : les feuilles claires et floues de la plante du premier plan couvrent les deux cibles voisines, poussées par le vent. Retour à la mesure suivante.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-44", "debut": "2026-10-08T19:00Z", "fin": "2026-10-08T21:00Z", "categorie": "No data", "description": "Une mesure manque pour tous les capteurs, références et cibles : un point absent sur toutes les courbes. La caméra a pris l'image de 20:00 et les métriques sont présentes, tension normale avant et après : la mesure n'a pas été faite ou pas transmise ; seule station touchée, cause non établie. Les courbes reprennent à la mesure suivante sans saut : rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-45", "debut": "2026-10-09T12:00Z", "fin": "2026-10-09T14:00Z", "categorie": "Visibility", "description": "Au lever du soleil, sur quelques mesures, parfois une seule : l'erreur de reconnaissance des références PWD_REF08_C09 à PWD_REF11_C09 monte nettement, sans rejet ; la compensation en est un peu perturbée et le corr_x, corr_y de nombreuses cibles saute ou s'agite ; e06 et e09, à gauche, sont souvent rejetées. Cause vue sur l'image du 21.10 à 13:00 : le soleil levant entre dans le champ juste au-dessus de la route des références, avec halo et reflets sur toute l'image ; elle revient aux mêmes heures les jours clairs. L'ouvrage ne bouge pas : ne pas croire les courbes sur ces mesures.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-46", "debut": "2026-10-09T12:00Z", "fin": "2026-10-10T00:00Z", "categorie": "Thermal displacement", "description": "Cycle thermique du jour (09/10). La température du boîtier monte fortement du matin jusqu'à 17:00, le plus vite entre 12:00 et 13:00, où elle gagne nettement. La pose de la caméra suit : de 13:00 à 15:00, le tilt monte fortement et la rotation baisse fortement, puis tous deux reviennent en grande partie d'un coup à 16:00 ; le pan monte nettement jusqu'à 16:00 et redescend jusque vers 18:00 ; l'échelle monte fortement jusqu'à 17:00 puis revient dans la soirée. Les positions brutes de tous les capteurs, références comprises, bougent ensemble dans l'image ; la compensation suit mal : le corr_x de PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B08_025_C09 et PWD_IMP_B07_017_C09 au centre et à droite se creuse fortement, celui de e02 et PWD_RMP_B12_017_C09 monte nettement ; le corr_y bouge en sens inverse, moins fort : il baisse pour e13, e10 et e02. Les cibles ne bougent pas tout à fait d'un bloc : face au mouvement d'ensemble, le résidu de celles qui s'en écartent le plus, faible le matin, grandit nettement dans la journée. D'une mesure à l'autre, tant que le boîtier est chaud (13:00-22:00), la pose et les courbes s'agitent aussi : le pas d'une mesure à la suivante est bien plus grand que la nuit sur le pan, le tilt et la rotation, bien plus grand sur le corr_x des cibles ; l'erreur de reconnaissance des cibles, elle, ne monte pas (elle baisse un peu). Les courbes retrouvent leur niveau de nuit vers 23:00. Cause déduite : la caméra et son support bougent avec la température du boîtier (pose et température vont ensemble), les références fixes sur la route bougent avec les cibles dans l'image. Normal, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-47", "debut": "2026-10-09T15:00Z", "fin": "2026-10-09T17:00Z", "categorie": "Obstruction", "description": "Une seule mesure : la référence PWD_REF08_C09 est cachée et rejetée, sa position brute saute ; la compensation tourne sans elle et les corr_x, corr_y de presque toutes les cibles sautent ensemble d'un pas, dans le même sens, puis reviennent à la mesure suivante. Cause vue sur l'image de 16:00 : une grosse masse sombre et floue tout près de l'objectif, en haut à gauche, devant la référence (un oiseau ou un insecte posé ou passant). Ce n'est pas un mouvement : point à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-48", "debut": "2026-10-09T19:00Z", "fin": "2026-10-09T21:00Z", "categorie": "Obstruction", "description": "Une seule mesure : e02, e06, e09, PWD_RMP_B17_026_C09 sont rejetées et manquent sur les courbes corrigées ; les références restent intactes. Les autres cibles ne bougent pas. Cause vue : un train de voyageurs, sombre, sur la voie du fond, sur l'image de 20:00. Tout revient à la mesure suivante : l'ouvrage ne bouge pas, point à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-49", "debut": "2026-10-09T22:00Z", "fin": "2026-10-10T01:00Z", "categorie": "Obstruction", "description": "PWD_IMP_B07_016_C09 seule : par moments son erreur de reconnaissance saute presque au maximum et la mesure est rejetée, ou, juste sous le seuil, son corr_x ou son corr_y fait un pic d'une mesure, puis revient ; ses voisines ne bougent pas. Cause vue sur la vignette de 23:00 : les feuilles touchent la tache ; c'est la plante du premier plan, agitée par le vent, qui, d'après l'expert, passe devant cette cible. L'ouvrage ne bouge pas : ignorer la courbe de cette cible sur la plage.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-50", "debut": "2026-10-10T12:00Z", "fin": "2026-10-10T23:00Z", "categorie": "Thermal displacement", "description": "Cycle thermique du jour (10/10). La température du boîtier monte nettement du matin jusqu'à 17:00, le plus vite entre 13:00 et 14:00, où elle gagne nettement. La pose de la caméra suit : de 13:00 à 14:00, le tilt monte nettement et la rotation baisse nettement, puis tous deux reviennent en grande partie d'un coup à 17:00 ; le pan monte nettement jusqu'à 17:00 et redescend jusque vers 21:00 ; l'échelle monte un peu jusqu'à 17:00 et ne revient que lentement, dans la nuit. Les positions brutes de tous les capteurs, références comprises, bougent ensemble dans l'image ; la compensation suit mal : le corr_x de PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_RMP_B12_019_C09 et PWD_IMP_B07_017_C09 au centre et à droite se creuse nettement, celui de e06, PWD_RMP_B15_018_C09, e02 et PWD_RMP_B17_026_C09 monte nettement ; le corr_y bouge en sens inverse, moins fort : il monte pour PWD_RMP_B12_017_C09, PWD_RMP_B15_018_C09 et PWD_IMP_B07_017_C09, il baisse pour e13, e15 et PWD_RMP_B12_019_C09. Les cibles ne bougent pas tout à fait d'un bloc : face au mouvement d'ensemble, le résidu de celles qui s'en écartent le plus, faible le matin, grandit fortement dans la journée. D'une mesure à l'autre, tant que le boîtier est chaud (13:00-22:00), la pose et les courbes s'agitent aussi : le pas d'une mesure à la suivante est nettement plus grand que la nuit sur le pan, le tilt et la rotation, nettement plus grand sur le corr_x des cibles ; l'erreur de reconnaissance des cibles, elle, ne monte pas (elle baisse un peu). Les courbes retrouvent leur niveau de nuit vers 23:00. Cause déduite : la caméra et son support bougent avec la température du boîtier (pose et température vont ensemble), les références fixes sur la route bougent avec les cibles dans l'image. Normal, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-51", "debut": "2026-10-10T23:00Z", "fin": "2026-10-11T01:00Z", "categorie": "No data", "description": "Une mesure manque pour tous les capteurs, références et cibles : un point absent sur toutes les courbes. La station tourne (métriques présentes à cette heure, tension normale avant et après) ; la cause du manque n'est pas établie (mesure non faite ou non transmise). Les courbes reprennent à la mesure suivante sans saut : rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-52", "debut": "2026-10-11T02:00Z", "fin": "2026-10-11T04:00Z", "categorie": "Obstruction", "description": "Une seule mesure : e02, e06, e09, e10, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_025_C09, e14, e15, PWD_RMP_B15_020_C09, PWD_IMP_B07_018_C09, PWD_RMP_B15_019_C09, PWD_RMP_B15_018_C09, PWD_IMP_B07_017_C09 sont rejetées et manquent sur les courbes corrigées ; les références restent intactes. Restées sous le seuil, e13, PWD_RMP_B12_020_C09, PWD_RMP_B12_019_C09, PWD_RMP_B12_018_C09, PWD_RMP_B12_017_C09 font un saut d'une mesure sur corr_x ou corr_y, puis reviennent. Cause vue : un train de marchandises, numéros des wagons lisibles, sur l'image de 03:00. Tout revient à la mesure suivante : l'ouvrage ne bouge pas, point à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-53", "debut": "2026-10-11T05:00Z", "fin": "2026-10-11T07:00Z", "categorie": "No data", "description": "Une mesure manque pour tous les capteurs, références et cibles : un point absent sur toutes les courbes. La station tourne (métriques présentes à cette heure, tension normale avant et après) ; la cause du manque n'est pas établie (mesure non faite ou non transmise). Les courbes reprennent à la mesure suivante sans saut : rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-54", "debut": "2026-10-11T15:00Z", "fin": "2026-10-11T18:00Z", "categorie": "Thermal displacement", "description": "Cycle thermique du jour (11/10). La température du boîtier monte un peu du matin jusqu'à 15:00, le plus vite entre 13:00 et 14:00, où elle gagne un peu. La pose de la caméra suit : le tilt monte un peu à 16:00 et revient à 17:00 ; le pan monte un peu jusqu'à 17:00 et redescend jusque vers 20:00. Ce jour, le cycle est faible : seul le pan sort de son bruit, de 16:00 à 17:00, et parmi les cibles seule PWD_IMP_B07_018_C09 se creuse nettement ; la compensation suit assez bien la pose pour que les autres courbes corrigées ne le montrent presque pas. Les positions brutes de tous les capteurs, références comprises, bougent ensemble dans l'image ; la compensation la suit en partie : le corr_x de PWD_IMP_B07_018_C09 et PWD_IMP_B07_017_C09 au centre et à droite se creuse nettement, celui de PWD_RMP_B15_019_C09 au centre et à droite monte un peu. Cause déduite : la caméra et son support bougent avec la température du boîtier (pose et température vont ensemble), les références fixes sur la route bougent avec les cibles dans l'image. Normal, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-55", "debut": "2026-10-11T21:00Z", "fin": "2026-10-12T04:00Z", "categorie": "Visibility", "description": "En soirée et en début de nuit, quelques heures : l'erreur de reconnaissance de nombreuses cibles monte, plusieurs sont rejetées par moments (surtout PWD_RMP_B12_019_C09, PWD_RMP_B15_018_C09, e06, e09, PWD_RMP_B12_017_C09, PWD_RMP_B12_018_C09 et PWD_IMP_B07_017_C09) et les autres s'agitent ; les références tiennent, plus haut sur la route. Retour avant minuit. Cause probable : pluie ou brume (taches plus petites et plus faibles sur les vignettes de 01:00, sans obstacle). L'ouvrage ne bouge pas : ne pas croire les courbes sur la plage.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-56", "debut": "2026-10-12T03:00Z", "fin": "2026-10-12T05:00Z", "categorie": "Obstruction", "description": "Une seule mesure : e02, e06, e09, e10, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_025_C09, e14, e15, PWD_RMP_B15_020_C09, PWD_IMP_B07_018_C09, PWD_RMP_B15_019_C09, PWD_RMP_B15_018_C09 sont rejetées et manquent sur les courbes corrigées ; les références restent intactes. Restées sous le seuil, e13, PWD_RMP_B12_018_C09, PWD_IMP_B07_017_C09, PWD_RMP_B12_017_C09, PWD_RMP_B15_017_C09 font un saut d'une mesure sur corr_x ou corr_y, puis reviennent. Cause vue : un train de marchandises, numéros des wagons lisibles, sur l'image de 04:00. Tout revient à la mesure suivante : l'ouvrage ne bouge pas, point à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-57", "debut": "2026-10-12T15:00Z", "fin": "2026-10-13T00:00Z", "categorie": "Thermal displacement", "description": "Cycle thermique du jour (12/10). La température du boîtier monte nettement du matin jusqu'à 19:00, le plus vite entre 15:00 et 16:00, où elle gagne un peu. La pose de la caméra suit : le tilt baisse un peu à 19:00 et revient à 20:00 ; la rotation monte un peu à 18:00 et revient à 19:00 ; le pan monte nettement jusqu'à 18:00 et redescend jusque vers 21:00 ; l'échelle monte nettement jusqu'à 19:00 et ne revient que lentement, dans la nuit. Ce jour, le cycle commence tard, avec la montée de la température vers 16:00, et le tilt et la rotation bougent à l'inverse des autres jours, d'une seule mesure. Les positions brutes de tous les capteurs, références comprises, bougent ensemble dans l'image ; la compensation suit mal : le corr_x de PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B08_025_C09 et PWD_RMP_B12_017_C09 au centre et à droite se creuse nettement, celui de PWD_RMP_B15_018_C09, PWD_RMP_B17_026_C09, e06 et PWD_RMP_B15_019_C09 monte nettement ; le corr_y bouge en sens inverse, moins fort : il monte pour PWD_RMP_B12_017_C09, il baisse pour PWD_IMP_B07_017_C09, e10 et PWD_RMP_B12_019_C09. Les cibles ne bougent pas tout à fait d'un bloc : face au mouvement d'ensemble, le résidu de celles qui s'en écartent le plus, faible le matin, grandit nettement dans la journée. D'une mesure à l'autre, tant que le boîtier est chaud (13:00-22:00), la pose et les courbes s'agitent aussi : le pas d'une mesure à la suivante est beaucoup plus grand que la nuit sur le pan, le tilt et la rotation, un peu plus grand sur le corr_x des cibles ; l'erreur de reconnaissance des cibles, elle, ne monte pas (elle baisse un peu). Les courbes retrouvent leur niveau de nuit vers 00:00. Cause déduite : la caméra et son support bougent avec la température du boîtier (pose et température vont ensemble), les références fixes sur la route bougent avec les cibles dans l'image. Normal, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-58", "debut": "2026-10-12T16:00Z", "fin": "2026-10-12T19:00Z", "categorie": "Obstruction", "description": "PWD_IMP_B07_016_C09 seule : par moments son erreur de reconnaissance saute presque au maximum et la mesure est rejetée, ou, juste sous le seuil, son corr_x ou son corr_y fait un pic d'une mesure, puis revient ; ses voisines ne bougent pas. Cause vue sur la vignette de 17:00 : les feuilles couvrent la tache, qui ne se voit plus ; c'est la plante du premier plan, agitée par le vent, qui, d'après l'expert, passe devant cette cible. L'ouvrage ne bouge pas : ignorer la courbe de cette cible sur la plage.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-59", "debut": "2026-10-13T04:00Z", "fin": "2026-10-13T06:00Z", "categorie": "Obstruction", "description": "Une seule mesure, la nuit : PWD_IMP_B07_017_C09, PWD_RMP_B12_018_C09 et PWD_RMP_B15_018_C09 sont rejetées et manquent sur les courbes corrigées ; les autres cibles et les références ne bougent pas. Cause vue sur l'image de 05:00 : un engin éclairé, une rangée de feux vifs, sur les voies au premier plan, en bas au milieu de l'image, et toute l'image est plus sombre qu'à l'heure d'avant. Tout revient à la mesure suivante : l'ouvrage ne bouge pas, point à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-60", "debut": "2026-10-13T07:00Z", "fin": "2026-10-13T20:00Z", "categorie": "Obstruction", "description": "PWD_IMP_B07_016_C09 seule : par moments son erreur de reconnaissance saute presque au maximum et la mesure est rejetée, ou, juste sous le seuil, son corr_x ou son corr_y fait un pic d'une mesure, puis revient ; ses voisines ne bougent pas. Cause vue sur la vignette de 13:00 : les feuilles couvrent la tache ; c'est la plante du premier plan, agitée par le vent, qui, d'après l'expert, passe devant cette cible. L'ouvrage ne bouge pas : ignorer la courbe de cette cible sur la plage.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-61", "debut": "2026-10-13T08:00Z", "fin": "2026-10-13T15:00Z", "categorie": "Visibility", "description": "La nuit et au matin, plusieurs heures : l'erreur de reconnaissance de nombreuses cibles monte, beaucoup sont rejetées par moments (surtout PWD_IMP_B07_017_C09, PWD_RMP_B12_017_C09, PWD_RMP_B12_018_C09, PWD_RMP_B15_018_C09, PWD_RMP_B15_019_C09, e06, e09, et les cibles de gauche) et les autres s'agitent ; les références tiennent, plus haut sur la route. Retour progressif en fin de matinée. Cause probable : pluie ou brume (taches plus petites et plus faibles sur les vignettes de 11:00, sans obstacle). L'ouvrage ne bouge pas : ne pas croire les courbes sur la plage.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-62", "debut": "2026-10-13T12:00Z", "fin": "2026-10-13T14:00Z", "categorie": "Obstruction", "description": "Une seule mesure : e02, e06, e09, e10, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_025_C09, e14, e15, PWD_RMP_B15_020_C09, PWD_IMP_B07_018_C09, PWD_RMP_B15_019_C09, PWD_RMP_B12_018_C09, PWD_RMP_B15_018_C09, PWD_IMP_B07_017_C09, PWD_RMP_B12_017_C09, PWD_IMP_B07_016_C09 sont rejetées et manquent sur les courbes corrigées ; les références restent intactes. Restées sous le seuil, e13, PWD_RMP_B12_020_C09, PWD_RMP_B12_019_C09 font un saut d'une mesure sur corr_x ou corr_y, puis reviennent. Cause vue : un train de marchandises, numéros des wagons lisibles, sur l'image de 13:00. Tout revient à la mesure suivante : l'ouvrage ne bouge pas, point à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-63", "debut": "2026-10-13T13:00Z", "fin": "2026-10-14T00:00Z", "categorie": "Thermal displacement", "description": "Cycle thermique du jour (13/10). La température du boîtier monte fortement du matin jusqu'à 18:00, le plus vite entre 13:00 et 14:00, où elle gagne nettement. La pose de la caméra suit : de 14:00 à 16:00, le tilt monte nettement et la rotation baisse nettement, puis tous deux reviennent d'un coup à 17:00 ; le pan monte nettement jusqu'à 17:00 et redescend jusque vers 19:00 ; l'échelle monte fortement jusqu'à 20:00 et ne revient que lentement, dans la nuit. Les positions brutes de tous les capteurs, références comprises, bougent ensemble dans l'image ; la compensation suit mal : le corr_x de PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B07_017_C09 et PWD_RMP_B12_017_C09 au centre et à droite se creuse fortement, celui de e02 et PWD_RMP_B15_018_C09 monte nettement ; le corr_y bouge en sens inverse, moins fort : il monte pour PWD_RMP_B12_017_C09 et PWD_IMP_B07_017_C09, il baisse pour PWD_RMP_B12_019_C09, PWD_RMP_B12_018_C09 et PWD_RMP_B12_020_C09. D'une mesure à l'autre, tant que le boîtier est chaud (13:00-22:00), la pose et les courbes s'agitent aussi : le pas d'une mesure à la suivante est beaucoup plus grand que la nuit sur le pan, le tilt et la rotation, nettement plus grand sur le corr_x des cibles ; l'erreur de reconnaissance des cibles, elle, ne monte pas (elle baisse un peu). Cause déduite : la caméra et son support bougent avec la température du boîtier (pose et température vont ensemble), les références fixes sur la route bougent avec les cibles dans l'image. Normal, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-64", "debut": "2026-10-13T16:00Z", "fin": "2026-10-13T18:00Z", "categorie": "Obstruction", "description": "Une seule mesure : e02, e06, e09, PWD_RMP_B17_026_C09 sont rejetées et manquent sur les courbes corrigées ; les références restent intactes. Les autres cibles ne bougent pas. Cause vue : un train de voyageurs à deux étages sur la voie du fond, sur l'image de 17:00. Tout revient à la mesure suivante : l'ouvrage ne bouge pas, point à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-65", "debut": "2026-10-13T19:00Z", "fin": "2026-10-13T21:00Z", "categorie": "Obstruction", "description": "Une seule mesure : e02 est rejetée et manque sur les courbes corrigées ; les références restent intactes. Les autres cibles ne bougent pas. Cause vue : une masse sombre qui couvre e02 sur la vignette de 20:00, comme le bas d'un wagon. Tout revient à la mesure suivante : l'ouvrage ne bouge pas, point à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-66", "debut": "2026-10-13T22:00Z", "fin": "2026-10-14T00:00Z", "categorie": "Obstruction", "description": "Une seule mesure : e02, e06, e09, e10, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_025_C09, PWD_RMP_B15_020_C09, PWD_RMP_B15_019_C09, PWD_RMP_B15_018_C09 sont rejetées et manquent sur les courbes corrigées ; les références restent intactes. Restées sous le seuil, e13, e14, e15, PWD_RMP_B12_020_C09, PWD_RMP_B12_019_C09, PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B07_017_C09, PWD_RMP_B12_017_C09 font un saut d'une mesure sur corr_x ou corr_y, puis reviennent. Ce n'est pas un train : sur l'image de 23:00, une nuée d'insectes volants, éclairés par le projecteur, passe tout près de l'objectif sur la moitié gauche de l'image, en grandes taches blanches floues. Tout revient à la mesure suivante : l'ouvrage ne bouge pas, point à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-67", "debut": "2026-10-14T07:00Z", "fin": "2026-10-15T02:00Z", "categorie": "Obstruction", "description": "PWD_IMP_B07_016_C09 seule : par moments son erreur de reconnaissance saute presque au maximum et la mesure est rejetée, ou, juste sous le seuil, son corr_x ou son corr_y fait un pic d'une mesure, puis revient ; ses voisines ne bougent pas. Cause vue sur les vignettes de 08:00, 19:00 et 23:00 : les feuilles couvrent la tache, dégagée à 10:00 ; c'est la plante du premier plan, agitée par le vent, qui, d'après l'expert, passe devant cette cible. L'ouvrage ne bouge pas : ignorer la courbe de cette cible sur la plage.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-68", "debut": "2026-10-14T11:00Z", "fin": "2026-10-14T14:00Z", "categorie": "Visibility", "description": "Au lever du jour, une mesure surtout : e06, e09, PWD_RMP_B16_026_C09, PWD_IMP_B07_018_C09, PWD_RMP_B15_018_C09, PWD_IMP_B07_017_C09 sont rejetées, d'autres cibles font un saut puis reviennent ; les références tiennent. Cause vue sur l'image de 12:00 : la scène est voilée, laiteuse, comme sous la brume. L'ouvrage ne bouge pas : points à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-69", "debut": "2026-10-14T13:00Z", "fin": "2026-10-14T23:00Z", "categorie": "Thermal displacement", "description": "Cycle thermique du jour (14/10). La température du boîtier monte nettement du matin jusqu'à 21:00, le plus vite entre 13:00 et 14:00, où elle gagne nettement. La pose de la caméra suit : de 13:00 à 14:00, le tilt monte un peu et la rotation baisse un peu ; le tilt revient à 15:00, la rotation à 21:00 ; le pan monte nettement jusqu'à 21:00 et redescend jusque vers 22:00. Ce jour, le cycle est faible et le tilt ne sort de son bruit qu'à une mesure ; le pan culmine en soirée. Les positions brutes de tous les capteurs, références comprises, bougent ensemble dans l'image ; la compensation suit mal : le corr_x de PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09 et PWD_IMP_B07_017_C09 au centre et à droite se creuse nettement, celui de e06, PWD_RMP_B15_018_C09, e13 et e02 monte nettement ; le corr_y bouge en sens inverse, moins fort : il monte pour PWD_IMP_B07_017_C09. Les cibles ne bougent pas tout à fait d'un bloc : face au mouvement d'ensemble, le résidu de celles qui s'en écartent le plus, faible le matin, grandit un peu dans la journée. Les courbes retrouvent leur niveau de nuit vers 23:00. Cause déduite : la caméra et son support bougent avec la température du boîtier (pose et température vont ensemble), les références fixes sur la route bougent avec les cibles dans l'image. Normal, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-70", "debut": "2026-10-15T01:00Z", "fin": "2026-11-01T00:00Z", "categorie": "Target issue", "description": "PWD_RMP_B12_019_C09 est rejetée presque chaque nuit à partir de la mi-octobre, de la nuit au matin : sa courbe corrigée manque ces heures-là. Son erreur de reconnaissance tourne juste au-dessus du seuil ; sur les vignettes, sa tache de nuit est saturée et un peu étalée, la même les nuits où elle passe et celles où elle ne passe pas. Un problème de la cible, à la limite de son seuil sous le projecteur, pas un mouvement. Ignorer sa courbe la nuit ; revoir le seuil ou la cible.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-71", "debut": "2026-10-15T13:00Z", "fin": "2026-10-15T22:00Z", "categorie": "Thermal displacement", "description": "Cycle thermique du jour (15/10). La température du boîtier monte un peu du matin jusqu'à 18:00, le plus vite entre 16:00 et 17:00, où elle gagne un peu. La pose de la caméra suit : de 14:00 à 17:00, le tilt monte un peu et la rotation baisse un peu, puis tous deux reviennent en grande partie d'un coup à 18:00 ; le pan monte un peu jusqu'à 19:00 et redescend jusque vers 22:00. Ce jour, le cycle est faible : la température du boîtier ne gagne que très peu et seule PWD_IMP_B07_018_C09 se creuse nettement ; les mesures s'arrêtent à 22:00 (NIEDERHORN#72). Les positions brutes de tous les capteurs, références comprises, bougent ensemble dans l'image ; la compensation suit mal : le corr_x de PWD_IMP_B07_018_C09 au centre et à droite se creuse nettement, celui de PWD_RMP_B15_018_C09 au centre et à droite monte un peu ; le corr_y bouge en sens inverse, moins fort : il monte pour PWD_RMP_B15_018_C09 et PWD_IMP_B07_016_C09. Les cibles ne bougent pas tout à fait d'un bloc : face au mouvement d'ensemble, le résidu de celles qui s'en écartent le plus, faible le matin, grandit un peu dans la journée. D'une mesure à l'autre, tant que le boîtier est chaud (13:00-22:00), la pose et les courbes s'agitent aussi : le pas d'une mesure à la suivante est nettement plus grand que la nuit sur le pan, le tilt et la rotation, un peu plus grand sur le corr_x des cibles ; l'erreur de reconnaissance des cibles, elle, ne monte pas (elle baisse un peu). Les courbes retrouvent leur niveau de nuit vers 22:00. Cause déduite : la caméra et son support bougent avec la température du boîtier (pose et température vont ensemble), les références fixes sur la route bougent avec les cibles dans l'image. Normal, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-72", "debut": "2026-10-15T22:00Z", "fin": "2026-10-16T11:00Z", "categorie": "No data", "description": "Aucune mesure pour aucun capteur pendant la nuit du 15 au 16.10 : toutes les courbes manquent, et il n'y a pas d'image. Les métriques de la station manquent aussi une bonne partie de la nuit, puis reviennent au petit matin avant les mesures ; la tension est normale avant le trou, sans signe de coupure de courant. Le trou commence à la même heure, vers 23:00, sur toutes les stations qui mesuraient alors (LENZSPITZE n'a ses premières mesures qu'au milieu de cette nuit, WILDSTRUBEL est déjà arrêtée), et leurs métriques s'arrêtent en même temps sur la plupart ; mesures et métriques reprennent à des heures différentes selon la station, la plupart en fin de matinée. JUNGFRAU, dont les métriques continuent, accumule toute la nuit des entrées non envoyées, parties en fin de matinée, et ses mesures de la nuit manquent pourtant aux données : une cause commune hors des stations (transmission ou réception des données), pas une panne des stations ; elle n'est pas établie. Au retour, plusieurs cibles de gauche reprennent à un autre niveau (étiquette suivante). Les courbes manquent sur la plage ; vérifier si une intervention a eu lieu.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-73", "debut": "2026-10-15T22:00Z", "fin": "2026-10-16T12:00Z", "categorie": "Displacement", "description": "Après le trou de la nuit du 15 au 16.10, les cibles du bord gauche e06, e09, e10, e13, e15 et PWD_RMP_B16_026_C09 reprennent à un autre niveau : corr_x nettement plus bas pour e06, e09, e10, e13 et PWD_RMP_B16_026_C09, plus haut pour e15, corr_y plus haut pour e09, e10, e13 et e15 ; elles y restent les semaines suivantes, avec leur cycle de chaque jour. Les autres cibles et les références ne changent pas de niveau ; le résidu de ces cibles face au mouvement d'ensemble reste décalé. Rien sur les vignettes (ni obstacle, ni changement de forme de la tache). Cause non établie : redémarrage ou intervention pendant le trou, ou mouvement local de cette partie des voies. À vérifier : regarder ce qui s'est passé pendant le trou et surveiller ces cibles.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-74", "debut": "2026-10-15T22:00Z", "fin": "2026-10-16T18:00Z", "categorie": "Visibility", "description": "À la reprise des mesures après le trou de la nuit, au petit matin : de nombreuses cibles sont rejetées aux deux premières mesures (PWD_IMP_B07_017_C09, PWD_IMP_B07_018_C09, la rangée PWD_RMP_B12, PWD_RMP_B15_018_C09, PWD_RMP_B15_019_C09, e02, e06, e09), puis e06 et PWD_RMP_B16_026_C09 le restent jusqu'au début d'après-midi ; les références tiennent. Taches plus faibles sur l'image de 12:00, sans obstacle : cause probable, une nuit de pluie ou de brume comme les autres, non établie. Ne pas croire les courbes sur la plage.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-75", "debut": "2026-10-16T11:00Z", "fin": "2026-10-16T16:00Z", "categorie": "Thermal displacement", "description": "Cycle thermique faible et court, à la reprise des mesures après le trou de la nuit (NIEDERHORN#72). La température du boîtier monte un peu de 12:00 à 15:00 puis retombe à son niveau de départ à 16:00 ; l'échelle de la caméra monte un peu avec elle de 11:00 à 15:00, juste au-delà de son bruit, et redescend à 16:00, le pan baisse un peu jusqu'à 13:00 puis remonte lentement ; le tilt et la rotation ne bougent pas, et la pose ne s'agite pas d'une mesure à l'autre. Les courbes corrigées ne montrent pas de cycle lisible : la matinée est gênée (NIEDERHORN#74, jusqu'à 18:00) et les cibles du bord gauche viennent de changer de niveau (NIEDERHORN#73). Après 16:00, plus rien ne suit la température. Cause déduite : la caméra et son support bougent avec la température du boîtier. Normal, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-76", "debut": "2026-10-16T14:00Z", "fin": "2026-10-17T01:00Z", "categorie": "Obstruction", "description": "PWD_IMP_B07_016_C09 seule : par moments son erreur de reconnaissance saute presque au maximum et la mesure est rejetée, ou, juste sous le seuil, son corr_x ou son corr_y fait un pic d'une mesure, puis revient ; ses voisines ne bougent pas. Cause vue sur la vignette de 15:00 : les feuilles couvrent la tache ; c'est la plante du premier plan, agitée par le vent, qui, d'après l'expert, passe devant cette cible. L'ouvrage ne bouge pas : ignorer la courbe de cette cible sur la plage.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-77", "debut": "2026-10-16T16:00Z", "fin": "2026-10-16T18:00Z", "categorie": "Obstruction", "description": "Une seule mesure : e02, e06, e09, PWD_IMP_B07_016_C09 sont rejetées et manquent sur les courbes corrigées ; les références restent intactes. Restée sous le seuil, PWD_RMP_B17_026_C09 fait un saut d'une mesure sur corr_x ou corr_y, puis revient. Cause vue : un train de voyageurs à deux étages, flou de mouvement, sur l'image de 17:00. Tout revient à la mesure suivante : l'ouvrage ne bouge pas, point à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-78", "debut": "2026-10-16T18:00Z", "fin": "2026-10-16T20:00Z", "categorie": "Obstruction", "description": "Une seule mesure : e02, e06, e09 sont rejetées et manquent sur les courbes corrigées ; les références restent intactes. Restées sous le seuil, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09 font un saut d'une mesure sur corr_x ou corr_y, puis reviennent. Cause vue : un train de voyageurs sur la voie du fond, sur l'image de 19:00. Tout revient à la mesure suivante : l'ouvrage ne bouge pas, point à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-79", "debut": "2026-10-17T03:00Z", "fin": "2026-11-01T00:00Z", "categorie": "Target issue", "description": "PWD_IMP_B07_018_C09 est rejetée presque chaque nuit à partir du 17.10, de la nuit au matin : sa courbe corrigée manque ces heures-là. Son erreur de reconnaissance tourne juste au-dessus du seuil ; sur les vignettes, sa tache de nuit est grosse et saturée, sans obstacle, comme les nuits où elle passe. Un problème de la cible, à la limite de son seuil sous le projecteur, pas un mouvement. Ignorer sa courbe la nuit ; revoir le seuil ou la cible.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-80", "debut": "2026-10-17T04:00Z", "fin": "2026-10-17T18:00Z", "categorie": "Obstruction", "description": "PWD_IMP_B07_016_C09 seule : par moments son erreur de reconnaissance saute presque au maximum et la mesure est rejetée, ou, juste sous le seuil, son corr_x ou son corr_y fait un pic d'une mesure, puis revient ; ses voisines ne bougent pas. Cause vue sur la vignette de 05:00 : les feuilles couvrent la tache ; c'est la plante du premier plan, agitée par le vent, qui, d'après l'expert, passe devant cette cible. L'ouvrage ne bouge pas : ignorer la courbe de cette cible sur la plage.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-81", "debut": "2026-10-17T12:00Z", "fin": "2026-10-17T16:00Z", "categorie": "Visibility", "description": "Au lever du soleil, sur quelques mesures, parfois une seule : l'erreur de reconnaissance des références PWD_REF08_C09 à PWD_REF11_C09 monte nettement, sans rejet ; la compensation en est un peu perturbée et le corr_x, corr_y de nombreuses cibles saute ou s'agite ; e06 et e09, à gauche, sont souvent rejetées. Cause vue sur l'image du 21.10 à 13:00 : le soleil levant entre dans le champ juste au-dessus de la route des références, avec halo et reflets sur toute l'image ; elle revient aux mêmes heures les jours clairs. L'ouvrage ne bouge pas : ne pas croire les courbes sur ces mesures.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-82", "debut": "2026-10-17T12:00Z", "fin": "2026-10-18T00:00Z", "categorie": "Thermal displacement", "description": "Cycle thermique du jour (17/10). La température du boîtier monte fortement du matin jusqu'à 19:00, le plus vite entre 12:00 et 13:00, où elle gagne nettement. La pose de la caméra suit : de 13:00 à 16:00, le tilt monte fortement et la rotation baisse fortement, puis tous deux reviennent d'un coup à 17:00 ; le pan monte fortement jusqu'à 17:00 et redescend jusque vers 21:00 ; l'échelle monte fortement jusqu'à 19:00 et ne revient que lentement, dans la nuit. Les positions brutes de tous les capteurs, références comprises, bougent ensemble dans l'image ; la compensation suit mal : le corr_x de PWD_RMP_B12_018_C09, PWD_IMP_B07_018_C09, PWD_RMP_B12_017_C09 et PWD_IMP_B07_017_C09 au centre et à droite se creuse fortement, celui de e02, e10, e06 et e09 à gauche de l'image monte nettement ; le corr_y bouge en sens inverse, moins fort : il monte pour PWD_RMP_B12_017_C09, PWD_IMP_B07_017_C09 et PWD_RMP_B15_018_C09, il baisse pour e02, e09 et e15. Les cibles ne bougent pas tout à fait d'un bloc : face au mouvement d'ensemble, le résidu de celles qui s'en écartent le plus, faible le matin, grandit nettement dans la journée. D'une mesure à l'autre, tant que le boîtier est chaud (13:00-22:00), la pose et les courbes s'agitent aussi : le pas d'une mesure à la suivante est bien plus grand que la nuit sur le pan, le tilt et la rotation, bien plus grand sur le corr_x des cibles ; l'erreur de reconnaissance des cibles, elle, ne monte pas (elle baisse un peu). Les courbes retrouvent leur niveau de nuit vers 23:00. Cause déduite : la caméra et son support bougent avec la température du boîtier (pose et température vont ensemble), les références fixes sur la route bougent avec les cibles dans l'image. Normal, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-83", "debut": "2026-10-18T06:00Z", "fin": "2026-10-18T10:00Z", "categorie": "Obstruction", "description": "PWD_IMP_B07_016_C09 seule : sans aucun rejet, son corr_x et son corr_y font par moments un pic d'une mesure, juste sous le seuil, puis reviennent ; ses voisines ne bougent pas. Cause vue sur la vignette de 07:00 : le bout d'une feuille touche la tache ; c'est la plante du premier plan, agitée par le vent, qui, d'après l'expert, passe devant cette cible. L'ouvrage ne bouge pas : ignorer la courbe de cette cible sur la plage.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-84", "debut": "2026-10-18T12:00Z", "fin": "2026-10-18T14:00Z", "categorie": "Visibility", "description": "Au lever du soleil, sur quelques mesures, parfois une seule : l'erreur de reconnaissance des références PWD_REF08_C09 à PWD_REF11_C09 monte nettement, sans rejet ; la compensation en est un peu perturbée et le corr_x, corr_y de nombreuses cibles saute ou s'agite ; e06 et e09, à gauche, sont souvent rejetées. Cause vue sur l'image du 21.10 à 13:00 : le soleil levant entre dans le champ juste au-dessus de la route des références, avec halo et reflets sur toute l'image ; elle revient aux mêmes heures les jours clairs. L'ouvrage ne bouge pas : ne pas croire les courbes sur ces mesures.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-85", "debut": "2026-10-18T12:00Z", "fin": "2026-10-19T00:00Z", "categorie": "Thermal displacement", "description": "Cycle thermique du jour (18/10). La température du boîtier monte fortement du matin jusqu'à 16:00, le plus vite entre 12:00 et 13:00, où elle gagne nettement. La pose de la caméra suit : de 13:00 à 15:00, le tilt monte fortement et la rotation baisse fortement, puis tous deux reviennent d'un coup à 17:00 ; le pan monte nettement jusqu'à 17:00 et redescend jusque vers 19:00 ; l'échelle monte fortement jusqu'à 19:00 et ne revient que lentement, dans la nuit. Les positions brutes de tous les capteurs, références comprises, bougent ensemble dans l'image ; la compensation suit mal : le corr_x de PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B07_017_C09 et PWD_RMP_B12_017_C09 au centre et à droite se creuse fortement, celui de e02, e06, PWD_RMP_B17_026_C09 et PWD_RMP_B15_018_C09 monte nettement ; le corr_y bouge en sens inverse, moins fort : il monte pour PWD_RMP_B12_017_C09, PWD_IMP_B07_017_C09 et PWD_RMP_B15_018_C09, il baisse pour e02, e09 et e15. Les cibles ne bougent pas tout à fait d'un bloc : face au mouvement d'ensemble, le résidu de celles qui s'en écartent le plus, faible le matin, grandit fortement dans la journée. D'une mesure à l'autre, tant que le boîtier est chaud (13:00-22:00), la pose et les courbes s'agitent aussi : le pas d'une mesure à la suivante est beaucoup plus grand que la nuit sur le pan, le tilt et la rotation, bien plus grand sur le corr_x des cibles ; l'erreur de reconnaissance des cibles, elle, ne monte pas (elle baisse un peu). Les courbes retrouvent leur niveau de nuit vers 23:00. Cause déduite : la caméra et son support bougent avec la température du boîtier (pose et température vont ensemble), les références fixes sur la route bougent avec les cibles dans l'image. Normal, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-86", "debut": "2026-10-18T20:00Z", "fin": "2026-10-18T22:00Z", "categorie": "Obstruction", "description": "PWD_IMP_B07_016_C09 seule : par moments son erreur de reconnaissance saute presque au maximum et la mesure est rejetée, ou, juste sous le seuil, son corr_x ou son corr_y fait un pic d'une mesure, puis revient ; ses voisines ne bougent pas. Cause vue sur la vignette de 21:00 : les feuilles couvrent la tache, qui ne se voit plus ; c'est la plante du premier plan, agitée par le vent, qui, d'après l'expert, passe devant cette cible. L'ouvrage ne bouge pas : ignorer la courbe de cette cible sur la plage.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-87", "debut": "2026-10-19T05:00Z", "fin": "2026-10-19T22:00Z", "categorie": "Obstruction", "description": "PWD_IMP_B07_016_C09 seule : par moments son erreur de reconnaissance saute presque au maximum et la mesure est rejetée, ou, juste sous le seuil, son corr_x ou son corr_y fait un pic d'une mesure, puis revient ; ses voisines ne bougent pas. Cause vue sur les vignettes de 13:00 et 15:00 : le bout des feuilles touche la tache ; c'est la plante du premier plan, agitée par le vent, qui, d'après l'expert, passe devant cette cible. L'ouvrage ne bouge pas : ignorer la courbe de cette cible sur la plage.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-88", "debut": "2026-10-19T09:00Z", "fin": "2026-10-19T11:00Z", "categorie": "No data", "description": "Une mesure manque pour tous les capteurs, références et cibles : un point absent sur toutes les courbes. Les métriques de la station manquent aussi à cette heure, et il n'y a pas d'image ; tension normale avant et après. Les courbes reprennent à la mesure suivante sans saut. Le même trou tombe au même moment sur les autres stations qui mesurent à ce moment (CLARIDEN, FLORIDA, JUNGFRAU, LENZSPITZE, NORDEND, SNCF01) : une cause commune hors de la station (transmission ou réception des données), pas une panne de la station ; elle n'est pas établie. Les courbes manquent sur la plage ; rien à faire sur la station.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-89", "debut": "2026-10-19T11:00Z", "fin": "2026-10-19T15:00Z", "categorie": "Visibility", "description": "Au lever du soleil, sur quelques mesures, parfois une seule : l'erreur de reconnaissance des références PWD_REF08_C09 à PWD_REF11_C09 monte nettement, sans rejet ; la compensation en est un peu perturbée et le corr_x, corr_y de nombreuses cibles saute ou s'agite ; e06 et e09, à gauche, sont souvent rejetées. Cause vue sur l'image du 21.10 à 13:00 : le soleil levant entre dans le champ juste au-dessus de la route des références, avec halo et reflets sur toute l'image ; elle revient aux mêmes heures les jours clairs. L'ouvrage ne bouge pas : ne pas croire les courbes sur ces mesures.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-90", "debut": "2026-10-19T11:00Z", "fin": "2026-10-20T00:00Z", "categorie": "Thermal displacement", "description": "Cycle thermique du jour (19/10). La température du boîtier monte fortement du matin jusqu'à 19:00, le plus vite entre 13:00 et 14:00, où elle gagne nettement. La pose de la caméra suit : de 12:00 à 16:00, le tilt monte fortement et la rotation baisse fortement, puis tous deux reviennent d'un coup à 17:00 ; le pan monte nettement jusqu'à 17:00 et redescend jusque vers 19:00 ; l'échelle monte fortement jusqu'à 19:00 et ne revient que lentement, dans la nuit. Les positions brutes de tous les capteurs, références comprises, bougent ensemble dans l'image ; la compensation suit mal : le corr_x de PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B07_017_C09 et PWD_RMP_B12_017_C09 au centre et à droite se creuse fortement, celui de e02, e06, PWD_RMP_B17_026_C09 et PWD_RMP_B15_018_C09 monte nettement ; le corr_y bouge en sens inverse, moins fort : il monte pour PWD_RMP_B12_017_C09, PWD_RMP_B15_018_C09 et PWD_IMP_B07_017_C09, il baisse pour PWD_RMP_B12_019_C09, e15 et e10. Les cibles ne bougent pas tout à fait d'un bloc : face au mouvement d'ensemble, le résidu de celles qui s'en écartent le plus, faible le matin, grandit fortement dans la journée. D'une mesure à l'autre, tant que le boîtier est chaud (13:00-22:00), la pose et les courbes s'agitent aussi : le pas d'une mesure à la suivante est beaucoup plus grand que la nuit sur le pan, le tilt et la rotation, bien plus grand sur le corr_x des cibles ; l'erreur de reconnaissance des cibles, elle, ne monte pas (elle baisse un peu). Les courbes retrouvent leur niveau de nuit vers 23:00. Cause déduite : la caméra et son support bougent avec la température du boîtier (pose et température vont ensemble), les références fixes sur la route bougent avec les cibles dans l'image. Normal, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-91", "debut": "2026-10-19T20:00Z", "fin": "2026-10-19T22:00Z", "categorie": "No data", "description": "Une mesure manque pour tous les capteurs, références et cibles : un point absent sur toutes les courbes. Les métriques de la station manquent aussi à cette heure, et il n'y a pas d'image ; tension normale avant et après. Les courbes reprennent à la mesure suivante sans saut. Le même trou tombe au même moment sur les autres stations qui mesurent à ce moment (CLARIDEN, FLORIDA, JUNGFRAU, LENZSPITZE, NORDEND, SNCF01) : une cause commune hors de la station (transmission ou réception des données), pas une panne de la station ; elle n'est pas établie. Les courbes manquent sur la plage ; rien à faire sur la station. Les métriques horaires de BREITHORN, MICHIGAN et NEBRASKA manquent aussi à 21:00.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-92", "debut": "2026-10-20T05:00Z", "fin": "2026-10-20T13:00Z", "categorie": "Obstruction", "description": "PWD_IMP_B07_016_C09 seule : par moments son erreur de reconnaissance saute presque au maximum et la mesure est rejetée, ou, juste sous le seuil, son corr_x ou son corr_y fait un pic d'une mesure, puis revient ; ses voisines ne bougent pas. Cause : la plante du premier plan, agitée par le vent, passe devant la cible ; sur les vignettes de 07:00 et 09:00, le bout d'une feuille touche la tache, qui paraît coupée. L'ouvrage ne bouge pas : ignorer la courbe de cette cible sur la plage.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-93", "debut": "2026-10-20T11:00Z", "fin": "2026-10-20T13:00Z", "categorie": "Obstruction", "description": "Une seule mesure : e02, e06, e09, e10, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_025_C09, e14, PWD_RMP_B15_019_C09, PWD_IMP_B07_017_C09, PWD_IMP_B07_016_C09 sont rejetées et manquent sur les courbes corrigées ; les références restent intactes. Restées sous le seuil, e15, PWD_RMP_B12_020_C09, PWD_RMP_B15_020_C09, PWD_RMP_B12_019_C09, PWD_RMP_B12_018_C09, PWD_RMP_B15_018_C09 font un saut d'une mesure sur corr_x ou corr_y, puis reviennent. Cause vue : une bande sombre qui barre les voies sur l'image de 12:00, un train dans la pénombre de l'aube. Tout revient à la mesure suivante : l'ouvrage ne bouge pas, point à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-94", "debut": "2026-10-20T12:00Z", "fin": "2026-10-20T14:00Z", "categorie": "Visibility", "description": "Au lever du soleil, sur quelques mesures, parfois une seule : l'erreur de reconnaissance des références PWD_REF08_C09 à PWD_REF11_C09 monte nettement, sans rejet ; la compensation en est un peu perturbée et le corr_x, corr_y de nombreuses cibles saute ou s'agite ; e06 et e09, à gauche, sont souvent rejetées. Cause vue sur l'image du 21.10 à 13:00 : le soleil levant entre dans le champ juste au-dessus de la route des références, avec halo et reflets sur toute l'image ; elle revient aux mêmes heures les jours clairs. L'ouvrage ne bouge pas : ne pas croire les courbes sur ces mesures.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-95", "debut": "2026-10-20T12:00Z", "fin": "2026-10-20T23:00Z", "categorie": "Thermal displacement", "description": "Cycle thermique du jour (20/10). La température du boîtier monte fortement du matin jusqu'à 15:00, le plus vite entre 13:00 et 14:00, où elle gagne nettement. La pose de la caméra suit : de 13:00 à 15:00, le tilt monte fortement et la rotation baisse fortement, puis tous deux reviennent d'un coup à 17:00 ; le pan monte fortement jusqu'à 17:00 et redescend jusque vers 22:00 ; l'échelle monte nettement jusqu'à 19:00 puis revient dans la soirée. Les positions brutes de tous les capteurs, références comprises, bougent ensemble dans l'image ; la compensation suit mal : le corr_x de PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B08_025_C09 et PWD_IMP_B07_017_C09 au centre et à droite se creuse fortement, celui de e06, e02, e13 et PWD_RMP_B17_026_C09 à gauche de l'image monte nettement ; le corr_y bouge en sens inverse, moins fort : il monte pour PWD_RMP_B12_017_C09, PWD_IMP_B07_017_C09 et PWD_IMP_B08_025_C09, il baisse pour e15, e02 et e09. Les cibles ne bougent pas tout à fait d'un bloc : face au mouvement d'ensemble, le résidu de celles qui s'en écartent le plus, faible le matin, grandit fortement dans la journée. D'une mesure à l'autre, tant que le boîtier est chaud (13:00-22:00), la pose et les courbes s'agitent aussi : le pas d'une mesure à la suivante est bien plus grand que la nuit sur le pan, le tilt et la rotation, nettement plus grand sur le corr_x des cibles ; l'erreur de reconnaissance des cibles, elle, ne monte pas (elle baisse un peu). Les courbes retrouvent leur niveau de nuit vers 23:00. Cause déduite : la caméra et son support bougent avec la température du boîtier (pose et température vont ensemble), les références fixes sur la route bougent avec les cibles dans l'image. Normal, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-96", "debut": "2026-10-20T16:00Z", "fin": "2026-10-20T18:00Z", "categorie": "Obstruction", "description": "Une seule mesure : e02, e06, e09 sont rejetées et manquent sur les courbes corrigées ; les références restent intactes. Restées sous le seuil, PWD_RMP_B17_026_C09, e15 font un saut d'une mesure sur corr_x ou corr_y, puis reviennent. Cause vue : un train de voyageurs à deux étages sur la voie du fond, sur l'image de 17:00. Tout revient à la mesure suivante : l'ouvrage ne bouge pas, point à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-97", "debut": "2026-10-20T20:00Z", "fin": "2026-10-20T22:00Z", "categorie": "No data", "description": "Une mesure manque pour tous les capteurs, références et cibles : un point absent sur toutes les courbes. La caméra a pris l'image de 21:00 et les métriques sont présentes : la mesure n'a pas été faite ou pas transmise. Les mesures de CLARIDEN manquent aussi à cette heure, et celles d'aucune autre station : une cause commune est possible, non établie. Les courbes reprennent à la mesure suivante sans saut : rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-98", "debut": "2026-10-21T12:00Z", "fin": "2026-10-21T15:00Z", "categorie": "Visibility", "description": "Au lever du soleil, sur quelques mesures, parfois une seule : l'erreur de reconnaissance des références PWD_REF08_C09 à PWD_REF11_C09 monte nettement, sans rejet ; la compensation en est un peu perturbée et le corr_x, corr_y de nombreuses cibles saute ou s'agite ; e06 et e09, à gauche, sont souvent rejetées. Cause vue sur l'image du 21.10 à 13:00 : le soleil levant entre dans le champ juste au-dessus de la route des références, avec halo et reflets sur toute l'image ; elle revient aux mêmes heures les jours clairs. L'ouvrage ne bouge pas : ne pas croire les courbes sur ces mesures.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-99", "debut": "2026-10-21T12:00Z", "fin": "2026-10-21T23:00Z", "categorie": "Thermal displacement", "description": "Cycle thermique du jour (21/10). La température du boîtier monte fortement du matin jusqu'à 17:00, le plus vite entre 12:00 et 13:00, où elle gagne fortement. La pose de la caméra suit : de 13:00 à 16:00, le tilt monte fortement et la rotation baisse fortement, puis tous deux reviennent d'un coup à 17:00 ; le pan monte fortement jusqu'à 17:00 et redescend jusque vers 22:00 ; l'échelle monte fortement jusqu'à 17:00 puis revient dans la soirée. Les positions brutes de tous les capteurs, références comprises, bougent ensemble dans l'image ; la compensation suit mal : le corr_x de PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B07_017_C09 et PWD_RMP_B12_020_C09 se creuse fortement, celui de e02, e06, PWD_RMP_B17_026_C09 et e13 à gauche de l'image monte fortement ; le corr_y bouge en sens inverse, moins fort : il monte pour PWD_RMP_B12_017_C09, PWD_RMP_B15_018_C09 et PWD_IMP_B07_016_C09, il baisse pour e13, e02 et e09. Les cibles ne bougent pas tout à fait d'un bloc : face au mouvement d'ensemble, le résidu de celles qui s'en écartent le plus, faible le matin, grandit nettement dans la journée. D'une mesure à l'autre, tant que le boîtier est chaud (13:00-22:00), la pose et les courbes s'agitent aussi : le pas d'une mesure à la suivante est bien plus grand que la nuit sur le pan, le tilt et la rotation, bien plus grand sur le corr_x des cibles ; l'erreur de reconnaissance des cibles, elle, ne monte pas (elle baisse un peu). Les courbes retrouvent leur niveau de nuit vers 23:00. Cause déduite : la caméra et son support bougent avec la température du boîtier (pose et température vont ensemble), les références fixes sur la route bougent avec les cibles dans l'image. Normal, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-100", "debut": "2026-10-21T21:00Z", "fin": "2026-10-21T23:00Z", "categorie": "Obstruction", "description": "Une seule mesure : e02, e06, e09, e10, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_025_C09, e14, e15, PWD_RMP_B15_020_C09, PWD_RMP_B15_019_C09, PWD_RMP_B15_018_C09 sont rejetées et manquent sur les courbes corrigées ; les références restent intactes. Restées sous le seuil, PWD_RMP_B12_020_C09, PWD_RMP_B12_019_C09, PWD_RMP_B12_018_C09 font un saut d'une mesure sur corr_x ou corr_y, puis reviennent. Cause vue : un train de voyageurs, fenêtres et portes floues, sur l'image de 22:00. Tout revient à la mesure suivante : l'ouvrage ne bouge pas, point à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-101", "debut": "2026-10-22T12:00Z", "fin": "2026-10-22T15:00Z", "categorie": "Visibility", "description": "Au lever du soleil, sur quelques mesures, parfois une seule : l'erreur de reconnaissance des références PWD_REF08_C09 à PWD_REF11_C09 monte nettement, sans rejet ; la compensation en est un peu perturbée et le corr_x, corr_y de nombreuses cibles saute ou s'agite ; e06 et e09, à gauche, sont souvent rejetées. Cause vue sur l'image du 21.10 à 13:00 : le soleil levant entre dans le champ juste au-dessus de la route des références, avec halo et reflets sur toute l'image ; elle revient aux mêmes heures les jours clairs. L'ouvrage ne bouge pas : ne pas croire les courbes sur ces mesures.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-102", "debut": "2026-10-22T12:00Z", "fin": "2026-10-22T22:00Z", "categorie": "Thermal displacement", "description": "Cycle thermique du jour (22/10). La température du boîtier monte fortement du matin jusqu'à 17:00, le plus vite entre 13:00 et 14:00, où elle gagne fortement. La pose de la caméra suit : de 13:00 à 16:00, le tilt monte fortement et la rotation baisse fortement, puis tous deux reviennent d'un coup à 17:00 ; le pan monte nettement jusqu'à 17:00 et redescend jusque vers 19:00 ; l'échelle monte fortement jusqu'à 19:00 et ne revient que lentement, dans la nuit. Les positions brutes de tous les capteurs, références comprises, bougent ensemble dans l'image ; la compensation suit mal : le corr_x de PWD_RMP_B12_018_C09, PWD_RMP_B12_020_C09, e13 et e10 se creuse nettement, celui de e02, e06, PWD_RMP_B17_026_C09 et PWD_RMP_B12_017_C09 monte nettement ; le corr_y bouge en sens inverse, moins fort : il monte pour PWD_IMP_B07_017_C09, PWD_IMP_B08_025_C09 et PWD_RMP_B15_018_C09, il baisse pour e13 et e02. Les cibles ne bougent pas tout à fait d'un bloc : face au mouvement d'ensemble, le résidu de celles qui s'en écartent le plus, faible le matin, grandit nettement dans la journée. D'une mesure à l'autre, tant que le boîtier est chaud (13:00-22:00), la pose et les courbes s'agitent aussi : le pas d'une mesure à la suivante est bien plus grand que la nuit sur le pan, le tilt et la rotation, nettement plus grand sur le corr_x des cibles ; l'erreur de reconnaissance des cibles, elle, ne monte pas (elle baisse un peu). Les courbes retrouvent leur niveau de nuit vers 22:00. Cause déduite : la caméra et son support bougent avec la température du boîtier (pose et température vont ensemble), les références fixes sur la route bougent avec les cibles dans l'image. Normal, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-103", "debut": "2026-10-22T15:00Z", "fin": "2026-10-22T17:00Z", "categorie": "Obstruction", "description": "Une seule mesure : e02 est rejetée et manque sur les courbes corrigées ; les références restent intactes. Les autres cibles ne bougent pas. Cause vue : une masse sombre qui couvre e02 sur la vignette de 16:00, comme le bas d'un wagon. Tout revient à la mesure suivante : l'ouvrage ne bouge pas, point à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-104", "debut": "2026-10-22T23:00Z", "fin": "2026-10-23T01:00Z", "categorie": "No data", "description": "Une mesure manque pour tous les capteurs, références et cibles : un point absent sur toutes les courbes. La station tourne (métriques présentes à cette heure, tension normale avant et après) ; la cause du manque n'est pas établie (mesure non faite ou non transmise). Les courbes reprennent à la mesure suivante sans saut : rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-105", "debut": "2026-10-23T11:00Z", "fin": "2026-10-23T15:00Z", "categorie": "Obstruction", "description": "PWD_IMP_B07_016_C09 seule : par moments son erreur de reconnaissance saute presque au maximum et la mesure est rejetée, ou, juste sous le seuil, son corr_x ou son corr_y fait un pic d'une mesure, puis revient ; ses voisines ne bougent pas. Cause : la plante du premier plan, agitée par le vent, passe devant la cible ; sur les vignettes de 12:00 et 13:00, au lever du jour, des feuilles floues couvrent la tache, presque invisible. L'ouvrage ne bouge pas : ignorer la courbe de cette cible sur la plage.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-106", "debut": "2026-10-23T11:00Z", "fin": "2026-10-23T15:00Z", "categorie": "Visibility", "description": "Au lever du soleil, sur quelques mesures, parfois une seule : l'erreur de reconnaissance des références PWD_REF08_C09 à PWD_REF11_C09 monte nettement, sans rejet ; la compensation en est un peu perturbée et le corr_x, corr_y de nombreuses cibles saute ou s'agite ; e06 et e09, à gauche, sont souvent rejetées. Cause vue sur l'image du 21.10 à 13:00 : le soleil levant entre dans le champ juste au-dessus de la route des références, avec halo et reflets sur toute l'image ; elle revient aux mêmes heures les jours clairs. L'ouvrage ne bouge pas : ne pas croire les courbes sur ces mesures.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-107", "debut": "2026-10-23T12:00Z", "fin": "2026-10-23T22:00Z", "categorie": "Thermal displacement", "description": "Cycle thermique du jour (23/10). La température du boîtier monte fortement du matin jusqu'à 18:00, le plus vite entre 13:00 et 14:00, où elle gagne nettement. La pose de la caméra suit : de 13:00 à 15:00, le tilt monte fortement et la rotation baisse fortement, puis tous deux reviennent en grande partie d'un coup à 17:00 ; le pan monte fortement jusqu'à 21:00 et redescend jusque vers 22:00 ; l'échelle monte nettement jusqu'à 19:00 puis revient dans la soirée. Les positions brutes de tous les capteurs, références comprises, bougent ensemble dans l'image ; la compensation suit mal : le corr_x de PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B07_017_C09 et PWD_RMP_B15_020_C09 au centre et à droite se creuse fortement, celui de e02, e06, PWD_RMP_B17_026_C09 et e09 à gauche de l'image monte nettement ; le corr_y bouge en sens inverse, moins fort : il monte pour PWD_RMP_B12_017_C09 et PWD_RMP_B15_018_C09, il baisse pour e15, e13 et e02. Les cibles ne bougent pas tout à fait d'un bloc : face au mouvement d'ensemble, le résidu de celles qui s'en écartent le plus, faible le matin, grandit nettement dans la journée. D'une mesure à l'autre, tant que le boîtier est chaud (13:00-22:00), la pose et les courbes s'agitent aussi : le pas d'une mesure à la suivante est bien plus grand que la nuit sur le pan, le tilt et la rotation, bien plus grand sur le corr_x des cibles ; l'erreur de reconnaissance des cibles, elle, ne monte pas (elle baisse un peu). Les courbes retrouvent leur niveau de nuit vers 22:00. Cause déduite : la caméra et son support bougent avec la température du boîtier (pose et température vont ensemble), les références fixes sur la route bougent avec les cibles dans l'image. Normal, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-108", "debut": "2026-10-23T18:00Z", "fin": "2026-10-23T20:00Z", "categorie": "Obstruction", "description": "Une seule mesure : e02, e06, e09, e10, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_025_C09, PWD_RMP_B15_020_C09, PWD_IMP_B07_018_C09, PWD_RMP_B15_019_C09, PWD_RMP_B15_018_C09, PWD_IMP_B07_017_C09 sont rejetées et manquent sur les courbes corrigées ; les références restent intactes. Restées sous le seuil, e13, e14, PWD_RMP_B12_020_C09, PWD_RMP_B12_019_C09, PWD_RMP_B12_018_C09 font un saut d'une mesure sur corr_x ou corr_y, puis reviennent. Cause vue : un train de voyageurs à deux étages sur l'image de 19:00. Tout revient à la mesure suivante : l'ouvrage ne bouge pas, point à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-109", "debut": "2026-10-24T12:00Z", "fin": "2026-10-24T15:00Z", "categorie": "Visibility", "description": "Au lever du soleil, sur quelques mesures, parfois une seule : l'erreur de reconnaissance des références PWD_REF08_C09 à PWD_REF11_C09 monte nettement, sans rejet ; la compensation en est un peu perturbée et le corr_x, corr_y de nombreuses cibles saute ou s'agite ; e06 et e09, à gauche, sont souvent rejetées. Cause vue sur l'image du 21.10 à 13:00 : le soleil levant entre dans le champ juste au-dessus de la route des références, avec halo et reflets sur toute l'image ; elle revient aux mêmes heures les jours clairs. L'ouvrage ne bouge pas : ne pas croire les courbes sur ces mesures.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-110", "debut": "2026-10-24T12:00Z", "fin": "2026-10-24T23:00Z", "categorie": "Thermal displacement", "description": "Cycle thermique du jour (24/10). La température du boîtier monte fortement du matin jusqu'à 20:00, le plus vite entre 13:00 et 14:00, où elle gagne fortement. La pose de la caméra suit : de 13:00 à 15:00, le tilt monte fortement et la rotation baisse fortement, puis tous deux reviennent en grande partie d'un coup à 17:00 ; le pan monte nettement jusqu'à 17:00 et redescend jusque vers 22:00 ; l'échelle monte fortement jusqu'à 19:00 et ne revient que lentement, dans la nuit. Les positions brutes de tous les capteurs, références comprises, bougent ensemble dans l'image ; la compensation suit mal : le corr_x de PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B08_025_C09 et PWD_IMP_B07_017_C09 au centre et à droite se creuse fortement, celui de e06 à gauche de l'image monte nettement ; le corr_y bouge en sens inverse, moins fort : il monte pour PWD_RMP_B15_018_C09 et PWD_IMP_B07_016_C09, il baisse pour e09, e15 et PWD_RMP_B12_019_C09. Les cibles ne bougent pas tout à fait d'un bloc : face au mouvement d'ensemble, le résidu de celles qui s'en écartent le plus, faible le matin, grandit fortement dans la journée. D'une mesure à l'autre, tant que le boîtier est chaud (13:00-22:00), la pose et les courbes s'agitent aussi : le pas d'une mesure à la suivante est bien plus grand que la nuit sur le pan, le tilt et la rotation, nettement plus grand sur le corr_x des cibles ; l'erreur de reconnaissance des cibles, elle, ne monte pas (elle baisse un peu). Les courbes retrouvent leur niveau de nuit vers 23:00. Cause déduite : la caméra et son support bougent avec la température du boîtier (pose et température vont ensemble), les références fixes sur la route bougent avec les cibles dans l'image. Normal, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-111", "debut": "2026-10-24T16:00Z", "fin": "2026-10-24T20:00Z", "categorie": "Obstruction", "description": "Trois mesures de suite : PWD_IMP_B07_017_C09, PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_RMP_B12_019_C09, PWD_RMP_B15_018_C09 et PWD_RMP_B15_019_C09 sont rejetées et manquent sur les courbes corrigées ; les références et les autres cibles tiennent. Cause vue sur l'image de 18:00 : une camionnette de service garée sur les voies au premier plan, hayon ouvert, devant ces cibles. Tout revient quand elle part : l'ouvrage ne bouge pas, plage à ignorer pour ces cibles.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-112", "debut": "2026-10-25T03:00Z", "fin": "2026-10-25T17:00Z", "categorie": "Visibility", "description": "La nuit et au matin, plusieurs heures : l'erreur de reconnaissance de nombreuses cibles monte, beaucoup sont rejetées par moments (surtout e06, PWD_RMP_B16_026_C09, PWD_IMP_B07_017_C09, e13 et e15, puis e10, e09 et PWD_RMP_B12_020_C09) et les autres s'agitent ; les références tiennent, plus haut sur la route. Retour progressif en fin de matinée. Cause probable : pluie ou brume (taches plus petites et plus faibles sur les vignettes de 08:00, sans obstacle). L'ouvrage ne bouge pas : ne pas croire les courbes sur la plage.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-113", "debut": "2026-10-25T12:00Z", "fin": "2026-10-26T00:00Z", "categorie": "Thermal displacement", "description": "Cycle thermique du jour (25/10). La température du boîtier monte fortement du matin jusqu'à 15:00, le plus vite entre 13:00 et 14:00, où elle gagne fortement. La pose de la caméra suit : de 13:00 à 15:00, le tilt monte fortement et la rotation baisse fortement, puis tous deux reviennent en grande partie d'un coup à 17:00 ; le pan monte nettement jusqu'à 17:00 et redescend jusque vers 20:00 ; l'échelle monte fortement jusqu'à 19:00 et ne revient que lentement, dans la nuit. Les positions brutes de tous les capteurs, références comprises, bougent ensemble dans l'image ; la compensation suit mal : le corr_x de PWD_IMP_B07_017_C09 et PWD_RMP_B15_018_C09 au centre et à droite se creuse nettement, celui de e13, e06, PWD_RMP_B17_026_C09 et PWD_RMP_B16_026_C09 à gauche de l'image monte nettement ; le corr_y bouge en sens inverse, moins fort : il monte pour PWD_RMP_B12_017_C09 et PWD_RMP_B12_020_C09, il baisse pour e13, e09 et e15. Les cibles ne bougent pas tout à fait d'un bloc : face au mouvement d'ensemble, le résidu de celles qui s'en écartent le plus, faible le matin, grandit fortement dans la journée. D'une mesure à l'autre, tant que le boîtier est chaud (13:00-22:00), la pose et les courbes s'agitent aussi : le pas d'une mesure à la suivante est beaucoup plus grand que la nuit sur le pan, le tilt et la rotation, nettement plus grand sur le corr_x des cibles ; l'erreur de reconnaissance des cibles, elle, ne monte pas (elle baisse un peu). Les courbes retrouvent leur niveau de nuit vers 22:00. Cause déduite : la caméra et son support bougent avec la température du boîtier (pose et température vont ensemble), les références fixes sur la route bougent avec les cibles dans l'image. Normal, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-114", "debut": "2026-10-26T03:00Z", "fin": "2026-10-26T05:00Z", "categorie": "Obstruction", "description": "PWD_IMP_B07_016_C09 seule : sans aucun rejet, son corr_x et son corr_y font par moments un pic d'une mesure, juste sous le seuil, puis reviennent ; ses voisines ne bougent pas. Cause vue sur la vignette de 04:00 : le bout des feuilles touche la tache ; c'est la plante du premier plan, agitée par le vent, qui, d'après l'expert, passe devant cette cible. L'ouvrage ne bouge pas : ignorer la courbe de cette cible sur la plage.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-115", "debut": "2026-10-26T12:00Z", "fin": "2026-10-26T14:00Z", "categorie": "Obstruction", "description": "PWD_IMP_B07_016_C09 seule : par moments son erreur de reconnaissance saute presque au maximum et la mesure est rejetée, ou, juste sous le seuil, son corr_x ou son corr_y fait un pic d'une mesure, puis revient ; ses voisines ne bougent pas. Cause vue sur la vignette de 13:00 : encore sombre, la tache ne se voit plus, des feuilles floues devant elle ; c'est la plante du premier plan, agitée par le vent, qui, d'après l'expert, passe devant cette cible. L'ouvrage ne bouge pas : ignorer la courbe de cette cible sur la plage.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-116", "debut": "2026-10-26T13:00Z", "fin": "2026-10-26T16:00Z", "categorie": "Visibility", "description": "Au lever du jour, une mesure : e06 est rejetée et manque sur sa courbe corrigée, l'erreur de reconnaissance d'une référence, PWD_REF10_C09, monte, la pose de la caméra fait un saut d'une mesure (tilt, rotation) et le corr_x de PWD_IMP_B07_018_C09 et PWD_IMP_B08_024_C09 s'écarte un peu ; la mesure suivante manque pour tous les capteurs. Sur l'image de 14:00, le ciel est éclatant derrière les nuages au-dessus des références, sans soleil visible : cause probable, la lumière du lever du jour, comme les matins de soleil, en plus faible. L'ouvrage ne bouge pas : ne pas croire les courbes sur cette mesure.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-117", "debut": "2026-10-26T14:00Z", "fin": "2026-10-26T16:00Z", "categorie": "No data", "description": "Une mesure manque pour tous les capteurs, références et cibles : un point absent sur toutes les courbes. Les métriques de la station manquent aussi à cette heure, et il n'y a pas d'image ; tension normale avant et après. Les courbes reprennent à la mesure suivante sans saut. Le même trou tombe au même moment sur les autres stations qui mesurent à ce moment (CLARIDEN, FLORIDA, JUNGFRAU, LENZSPITZE, NORDEND, SNCF01), et leurs métriques manquent aussi aux mêmes minutes : une cause commune hors de la station (transmission ou réception des données), pas une panne de la station ; elle n'est pas établie. Les courbes manquent sur la plage ; rien à faire sur la station. Les métriques horaires de BREITHORN, MICHIGAN et NEBRASKA manquent aussi à 15:00.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-118", "debut": "2026-10-26T21:00Z", "fin": "2026-10-26T23:00Z", "categorie": "Obstruction", "description": "Une seule mesure, en soirée : e02 seule est rejetée et manque sur sa courbe corrigée ; ses voisines et les références ne bougent pas. Cause vue sur l'image de 22:00 : une bande floue barre les voies du fond, un train qui passe, et la tache de e02 a disparu sur la vignette. Retour à la mesure suivante : l'ouvrage ne bouge pas, point à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-119", "debut": "2026-10-27T07:00Z", "fin": "2026-10-27T10:00Z", "categorie": "Obstruction", "description": "PWD_IMP_B07_016_C09 seule : par moments son erreur de reconnaissance saute presque au maximum et la mesure est rejetée, ou, juste sous le seuil, son corr_x ou son corr_y fait un pic d'une mesure, puis revient ; ses voisines ne bougent pas. Cause vue sur la vignette de 08:00 : les feuilles touchent la tache ; c'est la plante du premier plan, agitée par le vent, qui, d'après l'expert, passe devant cette cible. L'ouvrage ne bouge pas : ignorer la courbe de cette cible sur la plage.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-120", "debut": "2026-10-27T11:00Z", "fin": "2026-10-27T13:00Z", "categorie": "Obstruction", "description": "Une seule mesure : e02, e06, e09, PWD_RMP_B17_026_C09, PWD_RMP_B12_019_C09, PWD_IMP_B07_018_C09 sont rejetées et manquent sur les courbes corrigées ; les références restent intactes. Restée sous le seuil, PWD_RMP_B16_026_C09 fait un saut d'une mesure sur corr_x ou corr_y, puis revient. Cause vue : une bande sombre à bord droit qui barre la scène sur l'image de 12:00, un train dans la pénombre de l'aube. Tout revient à la mesure suivante : l'ouvrage ne bouge pas, point à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-121", "debut": "2026-10-27T12:00Z", "fin": "2026-10-27T16:00Z", "categorie": "Visibility", "description": "Au lever du soleil, sur quelques mesures, parfois une seule : l'erreur de reconnaissance des références PWD_REF08_C09 à PWD_REF11_C09 monte nettement, sans rejet ; la compensation en est un peu perturbée et le corr_x, corr_y de nombreuses cibles saute ou s'agite ; e06 et e09, à gauche, sont souvent rejetées. Cause vue sur l'image du 21.10 à 13:00 : le soleil levant entre dans le champ juste au-dessus de la route des références, avec halo et reflets sur toute l'image ; elle revient aux mêmes heures les jours clairs. L'ouvrage ne bouge pas : ne pas croire les courbes sur ces mesures.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-122", "debut": "2026-10-27T12:00Z", "fin": "2026-10-27T22:00Z", "categorie": "Thermal displacement", "description": "Cycle thermique du jour (27/10). La température du boîtier monte fortement du matin jusqu'à 20:00, le plus vite entre 13:00 et 14:00, où elle gagne nettement. La pose de la caméra suit : de 13:00 à 15:00, le tilt monte fortement et la rotation baisse fortement, puis tous deux reviennent en grande partie d'un coup à 17:00 ; le pan monte fortement jusqu'à 17:00 et redescend jusque vers 22:00 ; l'échelle monte nettement jusqu'à 20:00 et ne revient que lentement, dans la nuit. Les positions brutes de tous les capteurs, références comprises, bougent ensemble dans l'image ; la compensation suit mal : le corr_x de PWD_RMP_B12_018_C09, PWD_IMP_B07_018_C09, PWD_RMP_B12_017_C09 et PWD_IMP_B07_017_C09 au centre et à droite se creuse nettement, celui de e02, e06, e10 et PWD_RMP_B17_026_C09 à gauche de l'image monte nettement ; le corr_y bouge en sens inverse, moins fort : il monte pour PWD_RMP_B12_017_C09, il baisse pour e02, e15 et e13. Les cibles ne bougent pas tout à fait d'un bloc : face au mouvement d'ensemble, le résidu de celles qui s'en écartent le plus, faible le matin, grandit fortement dans la journée. D'une mesure à l'autre, tant que le boîtier est chaud (13:00-22:00), la pose et les courbes s'agitent aussi : le pas d'une mesure à la suivante est bien plus grand que la nuit sur le pan, le tilt et la rotation, nettement plus grand sur le corr_x des cibles ; l'erreur de reconnaissance des cibles, elle, ne monte pas (elle baisse un peu). Les courbes retrouvent leur niveau de nuit vers 22:00. Cause déduite : la caméra et son support bougent avec la température du boîtier (pose et température vont ensemble), les références fixes sur la route bougent avec les cibles dans l'image. Normal, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-123", "debut": "2026-10-28T11:00Z", "fin": "2026-10-28T13:00Z", "categorie": "No data", "description": "Une mesure manque pour tous les capteurs, références et cibles : un point absent sur toutes les courbes. La caméra a pris l'image de 12:00 et les métriques sont présentes : la mesure n'a pas été faite ou pas transmise ; cause non établie. Les courbes reprennent à la mesure suivante sans saut : rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-124", "debut": "2026-10-28T13:00Z", "fin": "2026-10-28T15:00Z", "categorie": "Obstruction", "description": "Une seule mesure : e02, e06, e09, e10, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_025_C09, e14, e15, PWD_RMP_B15_020_C09, PWD_IMP_B07_018_C09, PWD_RMP_B15_019_C09, PWD_RMP_B15_018_C09 sont rejetées et manquent sur les courbes corrigées ; les références restent intactes. Restées sous le seuil, e13, PWD_RMP_B12_020_C09, PWD_RMP_B12_019_C09, PWD_RMP_B12_018_C09, PWD_RMP_B12_017_C09 font un saut d'une mesure sur corr_x ou corr_y, puis reviennent. Cause vue : une bande sombre qui barre les voies sur l'image de 14:00, un train dans la pénombre de l'aube. Tout revient à la mesure suivante : l'ouvrage ne bouge pas, point à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-125", "debut": "2026-10-28T14:00Z", "fin": "2026-10-28T22:00Z", "categorie": "Thermal displacement", "description": "Cycle thermique du jour (28/10). La température du boîtier monte nettement du matin jusqu'à 18:00, le plus vite entre 17:00 et 18:00, où elle gagne nettement. La pose de la caméra suit : le tilt baisse un peu à 20:00 et revient à 22:00 ; la rotation baisse un peu à 16:00 et revient à 18:00 ; le pan monte nettement jusqu'à 18:00 et redescend jusque vers 22:00 ; l'échelle monte nettement jusqu'à 19:00 puis revient dans la soirée. Ce jour, le cycle commence tard, avec la montée de la température entre 15:00 et 18:00 ; le tilt baisse au lieu de monter et la rotation bouge peu. Les positions brutes de tous les capteurs, références comprises, bougent ensemble dans l'image ; la compensation suit mal : le corr_x de PWD_RMP_B12_018_C09, PWD_IMP_B07_018_C09, PWD_RMP_B12_017_C09 et PWD_RMP_B15_018_C09 au centre et à droite se creuse nettement, celui de e06, e02, PWD_RMP_B17_026_C09 et e09 à gauche de l'image monte fortement ; le corr_y bouge en sens inverse, moins fort : il monte pour PWD_IMP_B07_017_C09 et PWD_RMP_B15_018_C09, il baisse pour e15, e02 et e13. Les cibles ne bougent pas tout à fait d'un bloc : face au mouvement d'ensemble, le résidu de celles qui s'en écartent le plus, faible le matin, grandit fortement dans la journée. D'une mesure à l'autre, tant que le boîtier est chaud (13:00-22:00), la pose et les courbes s'agitent aussi : le pas d'une mesure à la suivante est nettement plus grand que la nuit sur le pan, le tilt et la rotation, un peu plus grand sur le corr_x des cibles ; l'erreur de reconnaissance des cibles, elle, ne monte pas (elle baisse un peu). Les courbes retrouvent leur niveau de nuit vers 22:00. Cause déduite : la caméra et son support bougent avec la température du boîtier (pose et température vont ensemble), les références fixes sur la route bougent avec les cibles dans l'image. Normal, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-126", "debut": "2026-10-28T18:00Z", "fin": "2026-10-28T20:00Z", "categorie": "Displacement", "description": "Une seule mesure : la référence PWD_REF11_C09 est rejetée (sa position brute saute) et écartée de la compensation ; quelques cibles (e02, e06, PWD_RMP_B12_017_C09) font un saut d'une mesure puis reviennent. Rien ne cache la référence sur l'image de 19:00 : cause non établie. Le retour est immédiat : pas un mouvement de l'ouvrage, point à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-127", "debut": "2026-10-29T00:00Z", "fin": "2026-10-29T16:00Z", "categorie": "Visibility", "description": "La nuit et au matin, plusieurs heures : l'erreur de reconnaissance de nombreuses cibles monte, beaucoup sont rejetées par moments (surtout e06, PWD_RMP_B16_026_C09, PWD_IMP_B07_017_C09, e13 et e15, puis e10, e09 et PWD_RMP_B12_020_C09) et les autres s'agitent ; les références tiennent, plus haut sur la route. Retour progressif en fin de matinée. Cause probable : pluie ou brume (taches nettement plus petites et plus faibles sur les vignettes de 10:00, image entière bruitée, sans obstacle). L'ouvrage ne bouge pas : ne pas croire les courbes sur la plage.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-128", "debut": "2026-10-29T12:00Z", "fin": "2026-10-29T14:00Z", "categorie": "Visibility", "description": "Au lever du soleil, sur quelques mesures, parfois une seule : l'erreur de reconnaissance des références PWD_REF08_C09 à PWD_REF11_C09 monte nettement, sans rejet ; la compensation en est un peu perturbée et le corr_x, corr_y de nombreuses cibles saute ou s'agite ; e06 et e09, à gauche, sont souvent rejetées. Cause vue sur l'image du 21.10 à 13:00 : le soleil levant entre dans le champ juste au-dessus de la route des références, avec halo et reflets sur toute l'image ; elle revient aux mêmes heures les jours clairs. L'ouvrage ne bouge pas : ne pas croire les courbes sur ces mesures.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-129", "debut": "2026-10-29T12:00Z", "fin": "2026-10-29T22:00Z", "categorie": "Thermal displacement", "description": "Cycle thermique du jour (29/10). La température du boîtier monte fortement du matin jusqu'à 18:00, le plus vite entre 13:00 et 14:00, où elle gagne nettement. La pose de la caméra suit : de 13:00 à 16:00, le tilt monte nettement et la rotation baisse fortement, puis tous deux reviennent d'un coup à 17:00 ; le pan monte nettement jusqu'à 17:00 et redescend jusque vers 18:00 ; l'échelle monte fortement jusqu'à 18:00 et ne revient que lentement, dans la nuit. Les positions brutes de tous les capteurs, références comprises, bougent ensemble dans l'image ; la compensation suit mal : le corr_x de PWD_IMP_B07_018_C09, PWD_RMP_B12_020_C09, PWD_RMP_B12_019_C09 et PWD_RMP_B12_018_C09 se creuse fortement, celui de e06, PWD_RMP_B17_026_C09, e02 et e09 à gauche de l'image monte nettement ; le corr_y bouge en sens inverse, moins fort : il monte pour PWD_RMP_B12_017_C09 et PWD_IMP_B07_016_C09, il baisse pour e09, e02 et e15. Les cibles ne bougent pas tout à fait d'un bloc : face au mouvement d'ensemble, le résidu de celles qui s'en écartent le plus, faible le matin, grandit fortement dans la journée. D'une mesure à l'autre, tant que le boîtier est chaud (13:00-22:00), la pose et les courbes s'agitent aussi : le pas d'une mesure à la suivante est nettement plus grand que la nuit sur le pan, le tilt et la rotation, nettement plus grand sur le corr_x des cibles ; l'erreur de reconnaissance des cibles, elle, ne monte pas (elle baisse un peu). Les courbes retrouvent leur niveau de nuit vers 22:00. Cause déduite : la caméra et son support bougent avec la température du boîtier (pose et température vont ensemble), les références fixes sur la route bougent avec les cibles dans l'image. Normal, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-130", "debut": "2026-10-29T20:00Z", "fin": "2026-10-29T23:00Z", "categorie": "Obstruction", "description": "Deux mesures : e06, e09, e10, e13, PWD_RMP_B16_026_C09, PWD_RMP_B12_019_C09, PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09 et PWD_RMP_B15_018_C09 sont rejetées à la première, e02, PWD_RMP_B16_026_C09 et PWD_IMP_B07_018_C09 à la seconde ; les références tiennent. Cause vue sur l'image de 21:00 : des insectes éclairés volent devant l'objectif, en taches floues sur les voies. Retour ensuite : l'ouvrage ne bouge pas, points à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-131", "debut": "2026-10-30T01:00Z", "fin": "2026-11-01T00:00Z", "categorie": "Displacement", "description": "D'un coup, dans la nuit, à la mesure de 02:00 : les cibles du bord gauche e14 et e15 sautent sur corr_x et corr_y et restent décalées, e10 saute aussi ; l'erreur de reconnaissance de e09, e10, e14, e15 et PWD_RMP_B16_026_C09 change de niveau au même instant et y reste. PWD_RMP_B16_026_C09 est rejetée à presque toutes les mesures jusqu'à la fin du lot, e10 souvent ; e09, e10 et e13 reviennent en partie vers leur niveau d'avant le 16.10 dans les heures qui suivent. Les références et les autres cibles ne bougent pas. Rien de visible sur les vignettes ni sur l'image de 02:00. Cause non établie (quelque chose a changé autour de ces cibles, ou elles ont bougé). À vérifier sur place ; surveiller ces cibles.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-132", "debut": "2026-10-30T01:00Z", "fin": "2026-11-01T00:00Z", "categorie": "Target issue", "description": "PWD_RMP_B16_026_C09 est rejetée à toutes les mesures à partir de 02:00 le 30.10, jusqu'à la fin du lot, et encore presque toutes celles du 01 au 03.11 qui suivent le lot : sa courbe corrigée manque. À cette mesure, son erreur de reconnaissance passe d'un peu sous son seuil à nettement au-dessus, et y reste, de jour comme de nuit, quel que soit le temps ; avant le 29.10 elle n'était rejetée qu'aux moments partagés avec ses voisines (trains, pluie, soleil levant). Le changement vient avec le saut des cibles du bord gauche à la même mesure (NIEDERHORN#131). Sur les vignettes, sa tache reste la même, petite et nette à côté d'une grosse voisine, sans obstacle. Cause non établie (quelque chose a changé autour de la cible, ou elle a bougé). Ignorer sa courbe ; vérifier la cible sur place, puis revoir son seuil.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-133", "debut": "2026-10-30T03:00Z", "fin": "2026-10-30T07:00Z", "categorie": "Obstruction", "description": "PWD_IMP_B07_016_C09 seule : par moments son erreur de reconnaissance saute presque au maximum et la mesure est rejetée, ou, juste sous le seuil, son corr_x ou son corr_y fait un pic d'une mesure, puis revient ; ses voisines ne bougent pas. Cause vue sur la vignette de 04:00 : les feuilles couvrent la tache ; c'est la plante du premier plan, agitée par le vent, qui, d'après l'expert, passe devant cette cible. L'ouvrage ne bouge pas : ignorer la courbe de cette cible sur la plage.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-134", "debut": "2026-10-30T03:00Z", "fin": "2026-11-01T00:00Z", "categorie": "Target issue", "description": "e10 est souvent rejetée à partir de 04:00 le 30.10, jusqu'à la fin du lot, surtout la nuit et le matin, et plus souvent encore, à la plupart des mesures, du 01 au 03.11 qui suivent le lot : sa courbe corrigée manque par moments. Depuis le saut des cibles du bord gauche à 02:00 (NIEDERHORN#131), son erreur de reconnaissance tourne autour de son seuil, juste en dessous ou juste au-dessus, alors qu'elle restait un peu sous lui avant, quel que soit le temps ; avant, elle n'était rejetée qu'aux moments partagés avec ses voisines. Sur les vignettes, sa tache, large et saturée la nuit, est la même qu'avant, sans obstacle. Cause non établie, la même que pour PWD_RMP_B16_026_C09. Ne pas croire ses points isolés ; vérifier la cible sur place, puis revoir son seuil.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-135", "debut": "2026-10-30T12:00Z", "fin": "2026-10-30T14:00Z", "categorie": "Visibility", "description": "Au lever du soleil, sur quelques mesures, parfois une seule : l'erreur de reconnaissance des références PWD_REF08_C09 à PWD_REF11_C09 monte nettement, sans rejet ; la compensation en est un peu perturbée et le corr_x, corr_y de nombreuses cibles saute ou s'agite ; e06 et e09, à gauche, sont souvent rejetées. Cause vue sur l'image du 21.10 à 13:00 : le soleil levant entre dans le champ juste au-dessus de la route des références, avec halo et reflets sur toute l'image ; elle revient aux mêmes heures les jours clairs. L'ouvrage ne bouge pas : ne pas croire les courbes sur ces mesures.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-136", "debut": "2026-10-30T12:00Z", "fin": "2026-10-30T22:00Z", "categorie": "Thermal displacement", "description": "Cycle thermique du jour (30/10). La température du boîtier monte fortement du matin jusqu'à 15:00, le plus vite entre 13:00 et 14:00, où elle gagne fortement. La pose de la caméra suit : de 13:00 à 15:00, le tilt monte fortement et la rotation baisse fortement, puis tous deux reviennent d'un coup à 16:00 ; le pan monte nettement jusqu'à 21:00 et redescend jusque vers 22:00 ; l'échelle monte un peu jusqu'à 21:00 puis revient dans la soirée. Les positions brutes de tous les capteurs, références comprises, bougent ensemble dans l'image ; la compensation suit mal : le corr_x de PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B07_017_C09 et PWD_RMP_B12_017_C09 au centre et à droite se creuse nettement, celui de e02, e06, PWD_RMP_B17_026_C09 et e14 à gauche de l'image monte nettement ; le corr_y bouge en sens inverse, moins fort : il monte pour PWD_RMP_B12_017_C09, PWD_IMP_B07_017_C09 et PWD_RMP_B15_018_C09, il baisse pour e15, e13 et e02. Les cibles ne bougent pas tout à fait d'un bloc : face au mouvement d'ensemble, le résidu de celles qui s'en écartent le plus, faible le matin, grandit nettement dans la journée. D'une mesure à l'autre, tant que le boîtier est chaud (13:00-22:00), la pose et les courbes s'agitent aussi : le pas d'une mesure à la suivante est nettement plus grand que la nuit sur le pan, le tilt et la rotation, nettement plus grand sur le corr_x des cibles ; l'erreur de reconnaissance des cibles, elle, ne monte pas (elle baisse un peu). Les courbes retrouvent leur niveau de nuit vers 22:00. Cause déduite : la caméra et son support bougent avec la température du boîtier (pose et température vont ensemble), les références fixes sur la route bougent avec les cibles dans l'image. Normal, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-137", "debut": "2026-10-31T10:00Z", "fin": "2026-10-31T12:00Z", "categorie": "Obstruction", "description": "Une seule mesure : e02, e06, e09, e10, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_025_C09, e15, PWD_RMP_B12_019_C09, PWD_IMP_B07_018_C09, PWD_RMP_B15_019_C09, PWD_IMP_B07_017_C09, PWD_IMP_B07_016_C09 sont rejetées et manquent sur les courbes corrigées ; les références restent intactes. Restées sous le seuil, e13, e14, PWD_RMP_B12_020_C09, PWD_RMP_B15_020_C09, PWD_RMP_B12_018_C09, PWD_RMP_B15_018_C09 font un saut d'une mesure sur corr_x ou corr_y, puis reviennent. Cause vue : un train de marchandises, numéros des wagons lisibles, sur l'image de 11:00. Tout revient à la mesure suivante : l'ouvrage ne bouge pas, point à ignorer.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-138", "debut": "2026-10-31T11:00Z", "fin": "2026-10-31T15:00Z", "categorie": "Visibility", "description": "Au lever du soleil : la référence PWD_REF11_C09 passe au-dessus de son seuil et est écartée de la compensation le temps d'une mesure ; les autres références montent aussi ; les corr_x, corr_y de nombreuses cibles sautent ensemble puis reviennent, e06 et e09 sont rejetées. Cause vue sur l'image de 13:00 : le soleil, dans le champ juste au-dessus de PWD_REF11_C09, éblouit la scène. Ce n'est pas un mouvement : ne pas croire les courbes sur ces mesures.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-139", "debut": "2026-10-31T12:00Z", "fin": "2026-10-31T23:00Z", "categorie": "Thermal displacement", "description": "Cycle thermique du jour (31/10). La température du boîtier monte fortement du matin jusqu'à 18:00, le plus vite entre 13:00 et 14:00, où elle gagne fortement. La pose de la caméra suit : de 13:00 à 15:00, le tilt monte fortement et la rotation baisse fortement, puis tous deux reviennent en grande partie d'un coup à 17:00 ; le pan monte nettement jusqu'à 17:00 et redescend jusque vers 20:00 ; l'échelle monte fortement jusqu'à 18:00 puis revient dans la soirée. Les positions brutes de tous les capteurs, références comprises, bougent ensemble dans l'image ; la compensation suit mal : le corr_x de PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_RMP_B12_017_C09 et PWD_IMP_B07_017_C09 au centre et à droite se creuse fortement, celui de e02, e06, PWD_RMP_B17_026_C09 et e09 à gauche de l'image monte nettement ; le corr_y bouge en sens inverse, moins fort : il monte pour PWD_RMP_B12_017_C09, PWD_RMP_B15_018_C09 et PWD_IMP_B07_017_C09, il baisse pour e02, e13 et e15. D'une mesure à l'autre, tant que le boîtier est chaud (13:00-22:00), la pose et les courbes s'agitent aussi : le pas d'une mesure à la suivante est bien plus grand que la nuit sur le pan, le tilt et la rotation, nettement plus grand sur le corr_x des cibles ; l'erreur de reconnaissance des cibles, elle, ne monte pas (elle baisse un peu). Les courbes retrouvent leur niveau de nuit vers 23:00. Cause déduite : la caméra et son support bougent avec la température du boîtier (pose et température vont ensemble), les références fixes sur la route bougent avec les cibles dans l'image. Normal, rien à faire.", "revue": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-1", "start": "2026-10-01T00:00Z", "end": "2026-10-01T02:00Z", "family": "No data", "description": "One measurement is missing for all sensors, references and targets: one point absent on all the curves. The station is running (metrics present at that hour, normal voltage before and after); the cause of the gap is not established (measurement not made or not transmitted). The curves resume at the next measurement without a jump: nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-2", "start": "2026-10-01T00:00Z", "end": "2026-11-01T00:00Z", "family": "Target issue", "description": "The target e03 is rejected at almost every measurement of the batch: its corrected curve does not exist (a few isolated points at most). Seen on the thumbnails: no spot is visible at its position on the thumbnails, day and night. It is not the weather: it is permanent, day and night. Act on the target or its configuration; ignore its curve.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-3", "start": "2026-10-01T00:00Z", "end": "2026-11-01T00:00Z", "family": "Target issue", "description": "The target e04 is rejected at almost every measurement of the batch: its corrected curve does not exist (a few isolated points at most). Seen on the thumbnails: no sharp spot is visible at its position on the thumbnails, only a small glow by day. It is not the weather: it is permanent, day and night. Act on the target or its configuration; ignore its curve.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-4", "start": "2026-10-01T00:00Z", "end": "2026-11-01T00:00Z", "family": "Target issue", "description": "The target e05 is rejected at almost every measurement of the batch: its corrected curve does not exist (a few isolated points at most). Seen on the thumbnails: no spot is visible at its position on the thumbnails, day and night. It is not the weather: it is permanent, day and night. Act on the target or its configuration; ignore its curve.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-5", "start": "2026-10-01T00:00Z", "end": "2026-11-01T00:00Z", "family": "Target issue", "description": "The target e07 is rejected at almost every measurement of the batch: its corrected curve does not exist (a few isolated points at most). Seen on the thumbnails: its spot is visible but between two very close neighbors; its recognition error stays above the threshold. It is not the weather: it is permanent, day and night. Act on the target or its configuration; ignore its curve.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-6", "start": "2026-10-01T00:00Z", "end": "2026-11-01T00:00Z", "family": "Target issue", "description": "The target e08 is rejected at almost every measurement of the batch: its corrected curve does not exist (a few isolated points at most). Seen on the thumbnails: its spot is visible but between two very close neighbors; its recognition error stays above the threshold. It is not the weather: it is permanent, day and night. Act on the target or its configuration; ignore its curve.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-7", "start": "2026-10-01T00:00Z", "end": "2026-11-01T00:00Z", "family": "Target issue", "description": "The target e11 is rejected at almost every measurement of the batch: its corrected curve does not exist (a few isolated points at most). Seen on the thumbnails: its spot is very large and dazzled at night, stuck to a small neighbor; its error stays above the threshold. It is not the weather: it is permanent, day and night. Act on the target or its configuration; ignore its curve.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-8", "start": "2026-10-01T00:00Z", "end": "2026-11-01T00:00Z", "family": "Target issue", "description": "The target e12 is rejected at almost every measurement of the batch: its corrected curve does not exist (a few isolated points at most). Seen on the thumbnails: its spot is very large and dazzled at night, stuck to a small neighbor; its error stays above the threshold. It is not the weather: it is permanent, day and night. Act on the target or its configuration; ignore its curve.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-9", "start": "2026-10-01T00:00Z", "end": "2026-11-01T00:00Z", "family": "Target issue", "description": "PWD_RMP_B15_017_C09 is rejected almost every night, from evening to morning, until 24.10 (except from the 12th to the 14th), then only a few hours on the nights of the 25th and 27.10, and one last measurement on 28.10 at 00:00 UTC; until then its corrected curve is missing every night. Afterwards it is kept at night too, but its daytime points stay, until the end of the batch, more scattered than those of its neighbors and change level from one day to the next. Seen on the thumbnails: at night, under the floodlight, its spot is saturated and spread out in a cross, while by day it is small and sharp; the neighbors of the same kind stay under the threshold. The rejections come back every night, whatever the weather: a problem of the target (too bright under the lighting), not a movement. Check its orientation or the lighting; ignore its curve.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-10", "start": "2026-10-01T00:00Z", "end": "2026-11-01T00:00Z", "family": "Target issue", "description": "e01 is rejected almost every day, from mid-morning to evening, and measured at night: its corrected curve is missing every day and, just under the threshold, its points rise clearly in the afternoon. Seen on the thumbnails: by day, its spot at the left edge of the image, in the vignetting, is almost melted into the background; at night it is sharp. Comes back every day, whatever the weather: the target has too little contrast by day. Ignore its daytime curve; see whether it can be better placed or lit.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-11", "start": "2026-10-01T00:00Z", "end": "2026-11-01T00:00Z", "family": "Target issue", "description": "PWD_IMP_B08_024_C09 is rejected on most days of the first half of the month, from late morning to evening, then more rarely: its corrected curve is missing at those hours. Its recognition error hovers just above its threshold by day, under it at night; on the thumbnails the spot is sharp, on a lit ballast background, without obstacle. Cause not established (target at the limit of its daytime threshold). Ignore its daytime curve; review its threshold or the target.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-12", "start": "2026-10-01T04:00Z", "end": "2026-10-01T16:00Z", "family": "Visibility", "description": "At night and in the morning, for several hours: the recognition error of many targets rises, many are rejected at times (mostly PWD_IMP_B07_017_C09, PWD_RMP_B12_017_C09, PWD_RMP_B12_018_C09, PWD_RMP_B15_018_C09, PWD_RMP_B15_019_C09, e06, e09, and the targets on the left) and the others become agitated; the references hold, higher up on the road. Gradual return in late morning. Probable cause: rain or mist (according to the expert, a rainy night at this station; spots weaker on the 07:00 thumbnails). The structure does not move: do not trust the curves over the range.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-13", "start": "2026-10-01T11:00Z", "end": "2026-10-01T14:00Z", "family": "Obstruction", "description": "A single measurement: e02, e06, e09, e10, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_025_C09, e14, e15, PWD_RMP_B15_020_C09, PWD_IMP_B07_018_C09, PWD_RMP_B15_019_C09, PWD_RMP_B15_018_C09 are rejected and missing from the corrected curves; the references stay intact. Kept under the threshold, PWD_RMP_B12_020_C09, PWD_RMP_B12_019_C09, PWD_RMP_B12_017_C09, PWD_IMP_B07_016_C09 make a one-measurement jump on corr_x or corr_y, then return. Cause seen: a freight train, wagon numbers legible, on the 12:00 image. Everything returns at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-14", "start": "2026-10-01T12:00Z", "end": "2026-10-01T14:00Z", "family": "No data", "description": "One measurement is missing for all sensors, references and targets: one point absent on all the curves. The station is running (metrics present at that hour, normal voltage before and after); the cause of the gap is not established (measurement not made or not transmitted). The curves resume at the next measurement without a jump: nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-15", "start": "2026-10-01T20:00Z", "end": "2026-10-01T22:00Z", "family": "Obstruction", "description": "A single measurement: e02, e06, e09, PWD_RMP_B17_026_C09 are rejected and missing from the corrected curves; the references stay intact. The other targets do not move. Cause seen: a double-decker passenger train, motion blur, on the 21:00 image. Everything returns at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-16", "start": "2026-10-02T02:00Z", "end": "2026-10-02T14:00Z", "family": "Visibility", "description": "At night and in the morning, for several hours: the recognition error of many targets rises, many are rejected at times (mostly PWD_IMP_B07_017_C09, PWD_RMP_B12_017_C09, PWD_RMP_B12_018_C09, PWD_RMP_B15_018_C09, PWD_RMP_B15_019_C09, e06, e09, and the targets on the left) and the others become agitated; the references hold, higher up on the road. Gradual return in late morning. Probable cause: rain or mist (according to the expert, a rainy night at this station, drops seen on its images). The structure does not move: do not trust the curves over the range.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-17", "start": "2026-10-02T07:00Z", "end": "2026-10-03T02:00Z", "family": "Obstruction", "description": "PWD_IMP_B07_016_C09 alone, for a good part of the day and the start of the night: its corr_x makes large peaks, alone among all the targets in early morning, then its measurement is rejected at times, or, just under the threshold, its corr_x or corr_y moves away for one measurement and returns; its neighbors do not move outside the rainy night of the morning. Cause seen on the 08:00, 09:00 and 10:00 thumbnails: the leaves of the foreground plant, pushed by the wind, touch then cover the spot of the target. The structure does not move: ignore the curve of this target over the range.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-18", "start": "2026-10-02T11:00Z", "end": "2026-10-02T13:00Z", "family": "No data", "description": "One measurement is missing for all sensors, references and targets: one point absent on all the curves. The station is running (metrics present at that hour, normal voltage before and after); the cause of the gap is not established (measurement not made or not transmitted). The curves resume at the next measurement without a jump: nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-19", "start": "2026-10-02T13:00Z", "end": "2026-10-02T23:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (02/10). The housing temperature rises strongly from the morning until 19:00, fastest between 13:00 and 14:00, where it gains a little. The camera pose follows: the tilt rises a little at 14:00 and returns at 19:00; the pan rises a little until 18:00 and goes back down until about 20:00; the scale rises clearly until 19:00 and only returns slowly, during the night. That day, the cycle follows a rainy morning (NIEDERHORN#16) and is weaker: the temperature rises slowly, the pose moves clearly less than on sunny days and is not agitated from one measurement to the next; the curves are compared with the night of the 3rd, the night of the 2nd being a rainy night. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_RMP_B12_020_C09 and PWD_IMP_B07_017_C09 sinks strongly, that of PWD_RMP_B15_018_C09, e02 and e06 rises clearly; the corr_y moves in the opposite direction, less strongly: it rises for e10, PWD_IMP_B07_017_C09 and PWD_RMP_B12_017_C09, it goes down for e14 and e02. Cause deduced: the camera and its support move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-20", "start": "2026-10-02T20:00Z", "end": "2026-10-02T22:00Z", "family": "Obstruction", "description": "A single measurement: e02, e06, e09, PWD_IMP_B07_016_C09 are rejected and missing from the corrected curves; the references stay intact. Kept under the threshold, PWD_RMP_B17_026_C09 makes a one-measurement jump on corr_x or corr_y, then returns. Cause seen: a double-decker passenger train, motion blur, on the far track, on the 21:00 image. Everything returns at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-21", "start": "2026-10-03T06:00Z", "end": "2026-10-03T08:00Z", "family": "Obstruction", "description": "A single measurement, in the middle of the night: PWD_IMP_B07_016_C09 alone is rejected and missing from its corrected curve, then returns; its neighbors do not move. Cause: the foreground plant, a leaf of which is very close to the spot on the 07:00 thumbnail. The structure does not move: ignore the curve of this target over the range.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-22", "start": "2026-10-03T09:00Z", "end": "2026-10-03T11:00Z", "family": "Obstruction", "description": "A single measurement, in the middle of the night: e02 alone is rejected and missing from its corrected curve; its neighbors and the references do not move. On the 10:00 thumbnail, the spot of e02 has disappeared while that of e06, right next to it, is intact: something hides it; nothing clear on the whole image, cause not established, same signature as the trains on the far track that hide e02 alone. Return at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-23", "start": "2026-10-03T12:00Z", "end": "2026-10-03T14:00Z", "family": "Visibility", "description": "At sunrise, over a few measurements, sometimes a single one: the recognition error of the references PWD_REF08_C09 to PWD_REF11_C09 rises clearly, without rejection; the compensation is slightly disturbed by it and the corr_x, corr_y of many targets jumps or becomes agitated; e06 and e09, on the left, are often rejected. Cause seen on the image of 21.10 at 13:00: the rising sun enters the field just above the road of the references, with halo and reflections over the whole image; it comes back at the same hours on clear days. The structure does not move: do not trust the curves over these measurements.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-24", "start": "2026-10-03T12:00Z", "end": "2026-10-03T23:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (03/10). The housing temperature rises strongly from the morning until 15:00, fastest between 12:00 and 13:00, where it gains clearly. The camera pose follows: from 13:00 to 16:00, the tilt rises strongly and the rotation drops strongly, then both return all at once at 17:00; the pan rises strongly until 17:00 and goes back down until about 19:00; the scale rises strongly until 19:00 and only returns slowly, during the night. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B07_017_C09 and PWD_IMP_B08_025_C09 in the center and on the right sinks strongly, that of e02, e06, PWD_RMP_B17_026_C09 and e14 on the left of the image rises strongly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_IMP_B07_017_C09, PWD_RMP_B12_017_C09 and PWD_RMP_B15_018_C09, it goes down for PWD_RMP_B12_019_C09, e15 and e13. The targets do not move quite as a block: against the overall movement, the residual of those that deviate from it the most, small in the morning, grows strongly during the day. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves are also agitated: the step from one measurement to the next is much larger than at night on the pan, tilt and rotation, clearly larger on the corr_x of the targets; the recognition error of the targets, for its part, does not rise (it drops a little). The curves regain their night level around 23:00. Cause deduced: the camera and its support move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-25", "start": "2026-10-04T12:00Z", "end": "2026-10-04T14:00Z", "family": "Visibility", "description": "At sunrise, over a few measurements, sometimes a single one: the recognition error of the references PWD_REF08_C09 to PWD_REF11_C09 rises clearly, without rejection; the compensation is slightly disturbed by it and the corr_x, corr_y of many targets jumps or becomes agitated; e06 and e09, on the left, are often rejected. Cause seen on the image of 21.10 at 13:00: the rising sun enters the field just above the road of the references, with halo and reflections over the whole image; it comes back at the same hours on clear days. The structure does not move: do not trust the curves over these measurements.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-26", "start": "2026-10-04T12:00Z", "end": "2026-10-05T00:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (04/10). The housing temperature rises strongly from the morning until 18:00, fastest between 12:00 and 13:00, where it gains clearly. The camera pose follows: the tilt drops clearly at 19:00 and returns at 20:00; the rotation drops clearly at 13:00 and returns at 18:00; the pan rises clearly until 17:00 and goes back down until about 19:00; the scale rises strongly until 19:00 and only returns slowly, during the night. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_RMP_B12_018_C09 and PWD_IMP_B08_025_C09 in the center and on the right sinks clearly, that of e02, PWD_RMP_B17_026_C09, e06 and PWD_RMP_B15_018_C09 rises clearly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_RMP_B15_018_C09, PWD_IMP_B07_017_C09 and PWD_RMP_B12_017_C09, it goes down for e02, e10 and PWD_RMP_B12_019_C09. The targets do not move quite as a block: against the overall movement, the residual of those that deviate from it the most, small in the morning, grows strongly during the day. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves are also agitated: the step from one measurement to the next is much larger than at night on the pan, tilt and rotation, slightly larger on the corr_x of the targets; the recognition error of the targets, for its part, does not rise (it drops a little). The curves regain their night level around 23:00. Cause deduced: the camera and its support move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-27", "start": "2026-10-05T12:00Z", "end": "2026-10-05T14:00Z", "family": "Visibility", "description": "At sunrise, over a few measurements, sometimes just one: the recognition error of the references PWD_REF08_C09 to PWD_REF11_C09 rises markedly, without rejection; the compensation is slightly disturbed and the corr_x, corr_y of many targets jump or fluctuate; e06 and e09, on the left, are often rejected. Cause seen on the image of 21.10 at 13:00: the rising sun enters the field just above the road of the references, with halo and reflections across the whole image; it comes back at the same hours on clear days. The structure does not move: do not trust the curves on these measurements.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-28", "start": "2026-10-05T12:00Z", "end": "2026-10-05T23:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (05/10). The housing temperature rises strongly from the morning until 18:00, fastest between 12:00 and 13:00, where it gains markedly. The camera pose follows: from 13:00 to 16:00, the tilt rises strongly and the rotation drops strongly, then both come back at once at 17:00; the pan rises strongly until 17:00 and goes back down until about 19:00; the scale rises markedly until 19:00 then comes back in the evening. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_RMP_B12_018_C09, PWD_IMP_B07_018_C09, PWD_IMP_B07_017_C09 and PWD_RMP_B12_017_C09 in the centre and on the right drops strongly, that of e02, e06, PWD_RMP_B17_026_C09 and PWD_RMP_B15_018_C09 rises strongly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_RMP_B12_017_C09, PWD_IMP_B07_017_C09 and PWD_RMP_B15_018_C09, it drops for e13, e02 and e15. The targets do not quite move as one block: against the overall movement, the residual of those that depart from it most, small in the morning, grows strongly during the day. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves also fluctuate: the step from one measurement to the next is much larger than at night on the pan, the tilt and the rotation, much larger on the corr_x of the targets; the recognition error of the targets, however, does not rise (it drops a little). The curves return to their night level around 23:00. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-29", "start": "2026-10-05T13:00Z", "end": "2026-10-05T22:00Z", "family": "Obstruction", "description": "PWD_IMP_B07_016_C09 alone: at times its recognition error jumps almost to the maximum and the measurement is rejected, or, just under the threshold, its corr_x or corr_y makes a one-measurement spike, then comes back; its neighbours do not move. Cause seen on the 14:00 thumbnail: leaves cover the spot, which fades; it is the foreground plant, shaken by the wind, which, according to the expert, passes in front of this target. The structure does not move: ignore this target's curve over the range.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-30", "start": "2026-10-06T03:00Z", "end": "2026-10-06T05:00Z", "family": "Obstruction", "description": "PWD_IMP_B07_016_C09 alone: at times its recognition error jumps almost to the maximum and the measurement is rejected, or, just under the threshold, its corr_x or corr_y makes a one-measurement spike, then comes back; its neighbours do not move. Cause seen on the 04:00 thumbnail: leaves touch the spot; it is the foreground plant, shaken by the wind, which, according to the expert, passes in front of this target. The structure does not move: ignore this target's curve over the range.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-31", "start": "2026-10-06T11:00Z", "end": "2026-10-06T13:00Z", "family": "Obstruction", "description": "A single measurement: e02, e06, e09, e10, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_025_C09, e14, e15, PWD_RMP_B15_020_C09, PWD_IMP_B07_018_C09, PWD_RMP_B15_019_C09, PWD_RMP_B15_018_C09 are rejected and missing from the corrected curves; the references stay intact. Remaining under the threshold, e13, PWD_RMP_B12_020_C09, PWD_RMP_B12_018_C09, PWD_IMP_B07_017_C09, PWD_RMP_B12_017_C09 make a one-measurement jump on corr_x or corr_y, then come back. Cause seen: a dark band with a right edge cutting across the scene on the 12:00 image, a train in the dim dawn light. Everything comes back at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-32", "start": "2026-10-06T12:00Z", "end": "2026-10-06T14:00Z", "family": "Visibility", "description": "At sunrise, just after the train of the previous measurement: the recognition error of the references PWD_REF08_C09, PWD_REF09_C09 and PWD_REF10_C09 rises markedly, without rejection, and the corr_x of e02, e06, e10 and PWD_IMP_B08_024_C09 departs for one measurement then comes back. Cause seen on the 13:00 image: the rising sun is in the field, above the road of the references, with halo and reflections. The structure does not move: do not trust the curves on this measurement.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-33", "start": "2026-10-06T12:00Z", "end": "2026-10-07T00:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (06/10). The housing temperature rises strongly from the morning until 20:00, fastest between 13:00 and 14:00, where it gains strongly. The camera pose follows: from 13:00 to 16:00, the tilt rises strongly and the rotation drops strongly, then both come back at once at 17:00; the pan rises strongly until 17:00 and goes back down until about 19:00; the scale rises strongly until 19:00 and only comes back slowly, during the night. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_RMP_B12_018_C09, PWD_IMP_B07_018_C09, PWD_IMP_B07_017_C09 and PWD_RMP_B12_017_C09 in the centre and on the right drops strongly, that of e02, e06, e10 and PWD_RMP_B17_026_C09 on the left of the image rises strongly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_RMP_B12_017_C09, PWD_IMP_B07_017_C09 and PWD_RMP_B15_018_C09, it drops for e13, e09 and PWD_RMP_B12_019_C09. The targets do not quite move as one block: against the overall movement, the residual of those that depart from it most, small in the morning, grows strongly during the day. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves also fluctuate: the step from one measurement to the next is much larger than at night on the pan, the tilt and the rotation, much larger on the corr_x of the targets; the recognition error of the targets, however, does not rise (it drops a little). The curves return to their night level around 23:00. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-34", "start": "2026-10-06T21:00Z", "end": "2026-10-06T23:00Z", "family": "Obstruction", "description": "A single measurement: e02, e06, e09, e10, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_025_C09, e14, e15, PWD_RMP_B15_020_C09, PWD_IMP_B07_018_C09, PWD_RMP_B15_019_C09, PWD_RMP_B15_018_C09, PWD_IMP_B07_017_C09, PWD_IMP_B07_016_C09 are rejected and missing from the corrected curves; the references stay intact. Remaining under the threshold, e13, PWD_RMP_B12_020_C09, PWD_RMP_B12_019_C09, PWD_RMP_B12_018_C09 make a one-measurement jump on corr_x or corr_y, then come back. Cause seen: a double-decker passenger train, motion blur, on the 22:00 image. Everything comes back at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-35", "start": "2026-10-06T22:00Z", "end": "2026-10-07T00:00Z", "family": "Obstruction", "description": "PWD_IMP_B07_016_C09 alone: at times its recognition error jumps almost to the maximum and the measurement is rejected, or, just under the threshold, its corr_x or corr_y makes a one-measurement spike, then comes back; its neighbours do not move. Cause seen on the 23:00 thumbnail: leaves cover the spot; it is the foreground plant, shaken by the wind, which, according to the expert, passes in front of this target. The structure does not move: ignore this target's curve over the range.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-36", "start": "2026-10-07T11:00Z", "end": "2026-10-07T13:00Z", "family": "Obstruction", "description": "A single measurement: e02, e06, e09, e10, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_025_C09, e14, e15, PWD_RMP_B15_020_C09, PWD_RMP_B15_018_C09 are rejected and missing from the corrected curves; the references stay intact. Remaining under the threshold, PWD_RMP_B12_020_C09, PWD_RMP_B12_019_C09, PWD_IMP_B07_018_C09, PWD_RMP_B15_019_C09, PWD_RMP_B12_018_C09, PWD_RMP_B12_017_C09 make a one-measurement jump on corr_x or corr_y, then come back. Cause seen: a dark band cutting across the tracks on the 12:00 image, a train in the dim dawn light. Everything comes back at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-37", "start": "2026-10-07T13:00Z", "end": "2026-10-07T18:00Z", "family": "Obstruction", "description": "PWD_IMP_B07_016_C09 alone: at times its recognition error jumps almost to the maximum and the measurement is rejected, or, just under the threshold, its corr_x or corr_y makes a one-measurement spike, then comes back; its neighbours do not move. Cause seen on the 14:00 thumbnail: a blurred leaf covers the spot, which can no longer be seen; it is the foreground plant, shaken by the wind, which, according to the expert, passes in front of this target. The structure does not move: ignore this target's curve over the range.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-38", "start": "2026-10-07T13:00Z", "end": "2026-10-08T00:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (07/10). The housing temperature rises strongly from the morning until 19:00, fastest between 15:00 and 16:00, where it gains a little. The camera pose follows: from 12:00 to 16:00, the tilt rises markedly and the rotation drops markedly, then both come back at once at 17:00 and 18:00; the pan rises markedly until 17:00 and goes back down until about 19:00; the scale rises strongly until 19:00 and only comes back slowly, during the night. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_RMP_B12_018_C09, PWD_IMP_B07_018_C09, PWD_IMP_B08_025_C09 and PWD_RMP_B12_017_C09 in the centre and on the right drops strongly, that of e06, e02, PWD_RMP_B17_026_C09 and PWD_RMP_B15_018_C09 rises markedly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_IMP_B07_017_C09 and PWD_IMP_B08_025_C09, it drops for e10, e13 and PWD_RMP_B12_019_C09. The targets do not quite move as one block: against the overall movement, the residual of those that depart from it most, small in the morning, grows strongly during the day. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves also fluctuate: the step from one measurement to the next is much larger than at night on the pan, the tilt and the rotation, much larger on the corr_x of the targets; the recognition error of the targets, however, does not rise (it drops a little). The curves return to their night level around 00:00. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-39", "start": "2026-10-08T00:00Z", "end": "2026-10-08T05:00Z", "family": "Visibility", "description": "At night, for a few hours: several targets fluctuate, especially PWD_RMP_B15_019_C09 and PWD_RMP_B15_020_C09, whose corr_y and corr_x depart markedly, and e06, e09 and PWD_RMP_B16_026_C09 are rejected once each; the references hold. On the 02:00 image, the background is noisier and the spots weaker than the night before at the same hour, without any obstacle: probable cause, rain or mist, not established. The structure does not move: do not trust the curves over the range.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-40", "start": "2026-10-08T01:00Z", "end": "2026-10-08T07:00Z", "family": "Obstruction", "description": "PWD_IMP_B07_016_C09 alone: at times its recognition error jumps almost to the maximum and the measurement is rejected, or, just under the threshold, its corr_x or corr_y makes a one-measurement spike, then comes back; its neighbours do not move. Cause seen on the 05:00 thumbnail: leaves cover the spot; it is the foreground plant, shaken by the wind, which, according to the expert, passes in front of this target. The structure does not move: ignore this target's curve over the range.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-41", "start": "2026-10-08T12:00Z", "end": "2026-10-08T14:00Z", "family": "Visibility", "description": "At sunrise, over a few measurements, sometimes just one: the recognition error of the references PWD_REF08_C09 to PWD_REF11_C09 rises markedly, without rejection; the compensation is slightly disturbed and the corr_x, corr_y of many targets jump or fluctuate; e06 and e09, on the left, are often rejected. Cause seen on the image of 21.10 at 13:00: the rising sun enters the field just above the road of the references, with halo and reflections across the whole image; it comes back at the same hours on clear days. The structure does not move: do not trust the curves on these measurements.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-42", "start": "2026-10-08T12:00Z", "end": "2026-10-08T23:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (08/10). The housing temperature rises strongly from the morning until 16:00, fastest between 12:00 and 13:00, where it gains strongly. The camera pose follows: from 13:00 to 15:00, the tilt rises strongly and the rotation drops strongly, then both come back at once at 17:00; the pan rises markedly until 17:00 and goes back down until about 18:00; the scale rises strongly until 17:00 then comes back in the evening. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B08_025_C09 and PWD_IMP_B07_017_C09 in the centre and on the right drops strongly, that of e02, PWD_RMP_B15_018_C09, PWD_RMP_B15_019_C09 and PWD_RMP_B16_026_C09 rises markedly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_RMP_B12_017_C09, PWD_IMP_B07_017_C09 and PWD_IMP_B08_025_C09, it drops for e13, e02 and e10. The targets do not quite move as one block: against the overall movement, the residual of those that depart from it most, small in the morning, grows strongly during the day. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves also fluctuate: the step from one measurement to the next is markedly larger than at night on the pan, the tilt and the rotation, markedly larger on the corr_x of the targets; the recognition error of the targets, however, does not rise (it drops a little). The curves return to their night level around 23:00. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-43", "start": "2026-10-08T16:00Z", "end": "2026-10-08T18:00Z", "family": "Obstruction", "description": "A single measurement: PWD_RMP_B12_017_C09 is rejected, and so is PWD_IMP_B07_016_C09; their neighbours hold. Cause seen on the 17:00 thumbnail: the pale, blurred leaves of the foreground plant cover the two neighbouring targets, pushed by the wind. Back to normal at the next measurement.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-44", "start": "2026-10-08T19:00Z", "end": "2026-10-08T21:00Z", "family": "No data", "description": "One measurement is missing for all the sensors, references and targets: one point absent on all the curves. The camera took the 20:00 image and the metrics are present, normal voltage before and after: the measurement was not made or not transmitted; only this station affected, cause not established. The curves resume at the next measurement without a jump: nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-45", "start": "2026-10-09T12:00Z", "end": "2026-10-09T14:00Z", "family": "Visibility", "description": "At sunrise, over a few measurements, sometimes just one: the recognition error of the references PWD_REF08_C09 to PWD_REF11_C09 rises markedly, without rejection; the compensation is slightly disturbed and the corr_x, corr_y of many targets jump or fluctuate; e06 and e09, on the left, are often rejected. Cause seen on the image of 21.10 at 13:00: the rising sun enters the field just above the road of the references, with halo and reflections across the whole image; it comes back at the same hours on clear days. The structure does not move: do not trust the curves on these measurements.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-46", "start": "2026-10-09T12:00Z", "end": "2026-10-10T00:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (09/10). The housing temperature rises strongly from the morning until 17:00, fastest between 12:00 and 13:00, where it gains markedly. The camera pose follows: from 13:00 to 15:00, the tilt rises strongly and the rotation drops strongly, then both come back largely at once at 16:00; the pan rises markedly until 16:00 and goes back down until about 18:00; the scale rises strongly until 17:00 then comes back in the evening. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B08_025_C09 and PWD_IMP_B07_017_C09 in the centre and on the right drops strongly, that of e02 and PWD_RMP_B12_017_C09 rises markedly; the corr_y moves in the opposite direction, less strongly: it drops for e13, e10 and e02. The targets do not quite move as one block: against the overall movement, the residual of those that depart from it most, small in the morning, grows markedly during the day. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves also fluctuate: the step from one measurement to the next is much larger than at night on the pan, the tilt and the rotation, much larger on the corr_x of the targets; the recognition error of the targets, however, does not rise (it drops a little). The curves return to their night level around 23:00. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-47", "start": "2026-10-09T15:00Z", "end": "2026-10-09T17:00Z", "family": "Obstruction", "description": "A single measurement: the reference PWD_REF08_C09 is hidden and rejected, its raw position jumps; the compensation runs without it and the corr_x, corr_y of almost all the targets jump together by one step, in the same direction, then come back at the next measurement. Cause seen on the 16:00 image: a large, dark, blurred mass very close to the lens, at the top left, in front of the reference (a bird or an insect, perched or passing). This is not a movement: point to ignore.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-48", "start": "2026-10-09T19:00Z", "end": "2026-10-09T21:00Z", "family": "Obstruction", "description": "A single measurement: e02, e06, e09, PWD_RMP_B17_026_C09 are rejected and missing from the corrected curves; the references stay intact. The other targets do not move. Cause seen: a dark passenger train on the far track, on the 20:00 image. Everything comes back at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-49", "start": "2026-10-09T22:00Z", "end": "2026-10-10T01:00Z", "family": "Obstruction", "description": "PWD_IMP_B07_016_C09 alone: at times its recognition error jumps almost to the maximum and the measurement is rejected, or, just under the threshold, its corr_x or corr_y makes a one-measurement spike, then comes back; its neighbours do not move. Cause seen on the 23:00 thumbnail: leaves touch the spot; it is the foreground plant, shaken by the wind, which, according to the expert, passes in front of this target. The structure does not move: ignore this target's curve over the range.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-50", "start": "2026-10-10T12:00Z", "end": "2026-10-10T23:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (10/10). The housing temperature rises markedly from the morning until 17:00, fastest between 13:00 and 14:00, where it gains markedly. The camera pose follows: from 13:00 to 14:00, the tilt rises markedly and the rotation drops markedly, then both come back largely at once at 17:00; the pan rises markedly until 17:00 and goes back down until about 21:00; the scale rises a little until 17:00 and only comes back slowly, during the night. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_RMP_B12_019_C09 and PWD_IMP_B07_017_C09 in the centre and on the right drops markedly, that of e06, PWD_RMP_B15_018_C09, e02 and PWD_RMP_B17_026_C09 rises markedly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_RMP_B12_017_C09, PWD_RMP_B15_018_C09 and PWD_IMP_B07_017_C09, it drops for e13, e15 and PWD_RMP_B12_019_C09. The targets do not quite move as one block: against the overall movement, the residual of those that depart from it most, small in the morning, grows strongly during the day. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves also fluctuate: the step from one measurement to the next is markedly larger than at night on the pan, the tilt and the rotation, markedly larger on the corr_x of the targets; the recognition error of the targets, however, does not rise (it drops a little). The curves return to their night level around 23:00. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-51", "start": "2026-10-10T23:00Z", "end": "2026-10-11T01:00Z", "family": "No data", "description": "One measurement is missing for all the sensors, references and targets: one point absent on all the curves. The station is running (metrics present at that hour, normal voltage before and after); the cause of the gap is not established (measurement not made or not transmitted). The curves resume at the next measurement without a jump: nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-52", "start": "2026-10-11T02:00Z", "end": "2026-10-11T04:00Z", "family": "Obstruction", "description": "A single measurement: e02, e06, e09, e10, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_025_C09, e14, e15, PWD_RMP_B15_020_C09, PWD_IMP_B07_018_C09, PWD_RMP_B15_019_C09, PWD_RMP_B15_018_C09, PWD_IMP_B07_017_C09 are rejected and missing from the corrected curves; the references stay intact. Remaining under the threshold, e13, PWD_RMP_B12_020_C09, PWD_RMP_B12_019_C09, PWD_RMP_B12_018_C09, PWD_RMP_B12_017_C09 make a one-measurement jump on corr_x or corr_y, then come back. Cause seen: a freight train, wagon numbers legible, on the 03:00 image. Everything comes back at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-53", "start": "2026-10-11T05:00Z", "end": "2026-10-11T07:00Z", "family": "No data", "description": "One measurement is missing for all the sensors, references and targets: one point absent on all the curves. The station is running (metrics present at that hour, normal voltage before and after); the cause of the gap is not established (measurement not made or not transmitted). The curves resume at the next measurement without a jump: nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-54", "start": "2026-10-11T15:00Z", "end": "2026-10-11T18:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (11/10). The housing temperature rises a little from the morning until 15:00, fastest between 13:00 and 14:00, where it gains a little. The camera pose follows: the tilt rises a little at 16:00 and comes back at 17:00; the pan rises a little until 17:00 and goes back down until about 20:00. This day, the cycle is weak: only the pan stands out of its noise, from 16:00 to 17:00, and among the targets only PWD_IMP_B07_018_C09 drops markedly; the compensation follows the pose well enough that the other corrected curves hardly show it. The raw positions of all the sensors, references included, move together in the image; the compensation follows it in part: the corr_x of PWD_IMP_B07_018_C09 and PWD_IMP_B07_017_C09 in the centre and on the right drops markedly, that of PWD_RMP_B15_019_C09 in the centre and on the right rises a little. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-55", "start": "2026-10-11T21:00Z", "end": "2026-10-12T04:00Z", "family": "Visibility", "description": "In the evening and early night, for a few hours: the recognition error of many targets rises, several are rejected at times (especially PWD_RMP_B12_019_C09, PWD_RMP_B15_018_C09, e06, e09, PWD_RMP_B12_017_C09, PWD_RMP_B12_018_C09 and PWD_IMP_B07_017_C09) and the others fluctuate; the references hold, higher up on the road. Back to normal before midnight. Probable cause: rain or mist (smaller and weaker spots on the 01:00 thumbnails, without any obstacle). The structure does not move: do not trust the curves over the range.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-56", "start": "2026-10-12T03:00Z", "end": "2026-10-12T05:00Z", "family": "Obstruction", "description": "A single measurement: e02, e06, e09, e10, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_025_C09, e14, e15, PWD_RMP_B15_020_C09, PWD_IMP_B07_018_C09, PWD_RMP_B15_019_C09, PWD_RMP_B15_018_C09 are rejected and missing from the corrected curves; the references stay intact. Remaining under the threshold, e13, PWD_RMP_B12_018_C09, PWD_IMP_B07_017_C09, PWD_RMP_B12_017_C09, PWD_RMP_B15_017_C09 make a one-measurement jump on corr_x or corr_y, then come back. Cause seen: a freight train, wagon numbers legible, on the 04:00 image. Everything comes back at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-57", "start": "2026-10-12T15:00Z", "end": "2026-10-13T00:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (12/10). The housing temperature rises markedly from the morning until 19:00, fastest between 15:00 and 16:00, where it gains a little. The camera pose follows: the tilt drops a little at 19:00 and comes back at 20:00; the rotation rises a little at 18:00 and comes back at 19:00; the pan rises markedly until 18:00 and goes back down until about 21:00; the scale rises markedly until 19:00 and only comes back slowly, during the night. This day, the cycle starts late, with the temperature rise around 16:00, and the tilt and the rotation move opposite to the other days, for a single measurement. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B08_025_C09 and PWD_RMP_B12_017_C09 in the centre and on the right drops markedly, that of PWD_RMP_B15_018_C09, PWD_RMP_B17_026_C09, e06 and PWD_RMP_B15_019_C09 rises markedly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_RMP_B12_017_C09, it drops for PWD_IMP_B07_017_C09, e10 and PWD_RMP_B12_019_C09. The targets do not quite move as one block: against the overall movement, the residual of those that depart from it most, small in the morning, grows markedly during the day. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves also fluctuate: the step from one measurement to the next is far larger than at night on the pan, the tilt and the rotation, a little larger on the corr_x of the targets; the recognition error of the targets, however, does not rise (it drops a little). The curves return to their night level around 00:00. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-58", "start": "2026-10-12T16:00Z", "end": "2026-10-12T19:00Z", "family": "Obstruction", "description": "PWD_IMP_B07_016_C09 alone: at times its recognition error jumps almost to the maximum and the measurement is rejected, or, just under the threshold, its corr_x or corr_y makes a one-measurement spike, then comes back; its neighbours do not move. Cause seen on the 17:00 thumbnail: leaves cover the spot, which can no longer be seen; it is the foreground plant, shaken by the wind, which, according to the expert, passes in front of this target. The structure does not move: ignore this target's curve over the range.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-59", "start": "2026-10-13T04:00Z", "end": "2026-10-13T06:00Z", "family": "Obstruction", "description": "A single measurement, at night: PWD_IMP_B07_017_C09, PWD_RMP_B12_018_C09 and PWD_RMP_B15_018_C09 are rejected and missing from the corrected curves; the other targets and the references do not move. Cause seen on the 05:00 image: a lit vehicle, a row of bright lights, on the tracks in the foreground, at the bottom middle of the image, and the whole image is darker than the hour before. Everything comes back at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-60", "start": "2026-10-13T07:00Z", "end": "2026-10-13T20:00Z", "family": "Obstruction", "description": "PWD_IMP_B07_016_C09 alone: at times its recognition error jumps almost to the maximum and the measurement is rejected, or, just under the threshold, its corr_x or corr_y makes a one-measurement spike, then comes back; its neighbours do not move. Cause seen on the 13:00 thumbnail: leaves cover the spot; it is the foreground plant, shaken by the wind, which, according to the expert, passes in front of this target. The structure does not move: ignore this target's curve over the range.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-61", "start": "2026-10-13T08:00Z", "end": "2026-10-13T15:00Z", "family": "Visibility", "description": "At night and in the morning, for several hours: the recognition error of many targets rises, many are rejected at times (especially PWD_IMP_B07_017_C09, PWD_RMP_B12_017_C09, PWD_RMP_B12_018_C09, PWD_RMP_B15_018_C09, PWD_RMP_B15_019_C09, e06, e09, and the targets on the left) and the others fluctuate; the references hold, higher up on the road. Gradual return to normal in late morning. Probable cause: rain or mist (smaller and weaker spots on the 11:00 thumbnails, without any obstacle). The structure does not move: do not trust the curves over the range.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-62", "start": "2026-10-13T12:00Z", "end": "2026-10-13T14:00Z", "family": "Obstruction", "description": "A single measurement: e02, e06, e09, e10, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_025_C09, e14, e15, PWD_RMP_B15_020_C09, PWD_IMP_B07_018_C09, PWD_RMP_B15_019_C09, PWD_RMP_B12_018_C09, PWD_RMP_B15_018_C09, PWD_IMP_B07_017_C09, PWD_RMP_B12_017_C09, PWD_IMP_B07_016_C09 are rejected and missing from the corrected curves; the references stay intact. Remaining under the threshold, e13, PWD_RMP_B12_020_C09, PWD_RMP_B12_019_C09 make a one-measurement jump on corr_x or corr_y, then come back. Cause seen: a freight train, wagon numbers legible, on the 13:00 image. Everything comes back at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-63", "start": "2026-10-13T13:00Z", "end": "2026-10-14T00:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (13/10). The housing temperature rises strongly from the morning until 18:00, fastest between 13:00 and 14:00, where it gains markedly. The camera pose follows: from 14:00 to 16:00, the tilt rises markedly and the rotation drops markedly, then both come back at once at 17:00; the pan rises markedly until 17:00 and goes back down until about 19:00; the scale rises strongly until 20:00 and only comes back slowly, during the night. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B07_017_C09 and PWD_RMP_B12_017_C09 in the centre and on the right drops strongly, that of e02 and PWD_RMP_B15_018_C09 rises markedly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_RMP_B12_017_C09 and PWD_IMP_B07_017_C09, it drops for PWD_RMP_B12_019_C09, PWD_RMP_B12_018_C09 and PWD_RMP_B12_020_C09. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves also fluctuate: the step from one measurement to the next is far larger than at night on the pan, the tilt and the rotation, markedly larger on the corr_x of the targets; the recognition error of the targets, however, does not rise (it drops a little). Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-64", "start": "2026-10-13T16:00Z", "end": "2026-10-13T18:00Z", "family": "Obstruction", "description": "A single measurement: e02, e06, e09, PWD_RMP_B17_026_C09 are rejected and missing from the corrected curves; the references stay intact. The other targets do not move. Cause seen: a double-decker passenger train on the far track, on the 17:00 image. Everything comes back at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-65", "start": "2026-10-13T19:00Z", "end": "2026-10-13T21:00Z", "family": "Obstruction", "description": "A single measurement: e02 is rejected and missing from the corrected curves; the references stay intact. The other targets do not move. Cause seen: a dark mass covering e02 on the 20:00 thumbnail, like the underside of a wagon. Everything comes back at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-66", "start": "2026-10-13T22:00Z", "end": "2026-10-14T00:00Z", "family": "Obstruction", "description": "A single measurement: e02, e06, e09, e10, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_025_C09, PWD_RMP_B15_020_C09, PWD_RMP_B15_019_C09, PWD_RMP_B15_018_C09 are rejected and missing from the corrected curves; the references stay intact. Remaining under the threshold, e13, e14, e15, PWD_RMP_B12_020_C09, PWD_RMP_B12_019_C09, PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B07_017_C09, PWD_RMP_B12_017_C09 make a one-measurement jump on corr_x or corr_y, then come back. This is not a train: on the 23:00 image, a swarm of flying insects, lit by the floodlight, passes very close to the lens over the left half of the image, as large blurred white spots. Everything comes back at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-67", "start": "2026-10-14T07:00Z", "end": "2026-10-15T02:00Z", "family": "Obstruction", "description": "PWD_IMP_B07_016_C09 alone: at times its recognition error jumps almost to the maximum and the measurement is rejected, or, just under the threshold, its corr_x or corr_y makes a one-measurement spike, then comes back; its neighbours do not move. Cause seen on the 08:00, 19:00 and 23:00 thumbnails: leaves cover the spot, clear at 10:00; it is the foreground plant, shaken by the wind, which, according to the expert, passes in front of this target. The structure does not move: ignore this target's curve over the range.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-68", "start": "2026-10-14T11:00Z", "end": "2026-10-14T14:00Z", "family": "Visibility", "description": "At daybreak, one measurement mostly: e06, e09, PWD_RMP_B16_026_C09, PWD_IMP_B07_018_C09, PWD_RMP_B15_018_C09, PWD_IMP_B07_017_C09 are rejected, other targets jump then come back; the references hold. Cause seen on the 12:00 image: the scene is veiled, milky, as under mist. The structure does not move: points to ignore.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-69", "start": "2026-10-14T13:00Z", "end": "2026-10-14T23:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (14/10). The housing temperature rises markedly from the morning until 21:00, fastest between 13:00 and 14:00, where it gains markedly. The camera pose follows: from 13:00 to 14:00, the tilt rises a little and the rotation drops a little; the tilt comes back at 15:00, the rotation at 21:00; the pan rises markedly until 21:00 and goes back down until about 22:00. This day, the cycle is weak and the tilt only stands out of its noise for one measurement; the pan peaks in the evening. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09 and PWD_IMP_B07_017_C09 in the centre and on the right drops markedly, that of e06, PWD_RMP_B15_018_C09, e13 and e02 rises markedly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_IMP_B07_017_C09. The targets do not quite move as one block: against the overall movement, the residual of those that depart from it most, small in the morning, grows a little during the day. The curves return to their night level around 23:00. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-70", "start": "2026-10-15T01:00Z", "end": "2026-11-01T00:00Z", "family": "Target issue", "description": "PWD_RMP_B12_019_C09 is rejected almost every night from mid-October, from night to morning: its corrected curve is missing those hours. Its recognition error hovers just above the threshold; on the thumbnails, its night spot is saturated and slightly spread out, the same on the nights when it passes and on those when it does not. A problem with the target, at the limit of its threshold under the floodlight, not a movement. Ignore its curve at night; review the threshold or the target.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-71", "start": "2026-10-15T13:00Z", "end": "2026-10-15T22:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (15/10). The housing temperature rises a little from the morning until 18:00, fastest between 16:00 and 17:00, where it gains a little. The camera pose follows: from 14:00 to 17:00, the tilt rises a little and the rotation drops a little, then both come back largely at once at 18:00; the pan rises a little until 19:00 and goes back down until about 22:00. This day, the cycle is weak: the housing temperature gains only very little and only PWD_IMP_B07_018_C09 drops markedly; the measurements stop at 22:00 (NIEDERHORN#72). The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_IMP_B07_018_C09 in the centre and on the right drops markedly, that of PWD_RMP_B15_018_C09 in the centre and on the right rises a little; the corr_y moves in the opposite direction, less strongly: it rises for PWD_RMP_B15_018_C09 and PWD_IMP_B07_016_C09. The targets do not quite move as one block: against the overall movement, the residual of those that depart from it most, small in the morning, grows a little during the day. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves also fluctuate: the step from one measurement to the next is markedly larger than at night on the pan, the tilt and the rotation, a little larger on the corr_x of the targets; the recognition error of the targets, however, does not rise (it drops a little). The curves return to their night level around 22:00. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-72", "start": "2026-10-15T22:00Z", "end": "2026-10-16T11:00Z", "family": "No data", "description": "No measurement for any sensor during the night of 15 to 16.10: all the curves are missing, and there is no image. The station metrics are also missing for a good part of the night, then come back in the early morning before the measurements; the voltage is normal before the gap, with no sign of a power cut. The gap starts at the same hour, around 23:00, on all the stations that were measuring then (LENZSPITZE only has its first measurements in the middle of this night, WILDSTRUBEL is already stopped), and their metrics stop at the same time on most of them; measurements and metrics resume at different hours depending on the station, most of them in late morning. JUNGFRAU, whose metrics continue, accumulates unsent entries all night, sent off in late morning, and its night measurements are nonetheless missing from the data: a common cause outside the stations (transmission or reception of the data), not a station failure; it is not established. On return, several targets on the left resume at another level (next label). The curves are missing over the range; check whether an intervention took place.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-73", "start": "2026-10-15T22:00Z", "end": "2026-10-16T12:00Z", "family": "Displacement", "description": "After the gap of the night of 15 to 16.10, the targets on the left edge e06, e09, e10, e13, e15 and PWD_RMP_B16_026_C09 resume at another level: corr_x markedly lower for e06, e09, e10, e13 and PWD_RMP_B16_026_C09, higher for e15, corr_y higher for e09, e10, e13 and e15; they stay there in the following weeks, with their cycle each day. The other targets and the references do not change level; the residual of these targets against the overall movement stays offset. Nothing on the thumbnails (neither obstacle nor change in the shape of the spot). Cause not established: restart or intervention during the gap, or local movement of this part of the tracks. To check: look at what happened during the gap and monitor these targets.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-74", "start": "2026-10-15T22:00Z", "end": "2026-10-16T18:00Z", "family": "Visibility", "description": "When measurements resume after the night gap, in the early morning: many targets are rejected at the first two measurements (PWD_IMP_B07_017_C09, PWD_IMP_B07_018_C09, the PWD_RMP_B12 row, PWD_RMP_B15_018_C09, PWD_RMP_B15_019_C09, e02, e06, e09), then e06 and PWD_RMP_B16_026_C09 stay so until early afternoon; the references hold. Weaker spots on the 12:00 image, without any obstacle: probable cause, a night of rain or mist like the others, not established. Do not trust the curves over the range.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-75", "start": "2026-10-16T11:00Z", "end": "2026-10-16T16:00Z", "family": "Thermal displacement", "description": "Weak, short thermal cycle, when measurements resume after the night gap (NIEDERHORN#72). The housing temperature rises a little from 12:00 to 15:00 then falls back to its starting level at 16:00; the camera scale rises a little with it from 11:00 to 15:00, just beyond its noise, and comes back down at 16:00, the pan drops a little until 13:00 then slowly rises again; the tilt and the rotation do not move, and the pose does not fluctuate from one measurement to the next. The corrected curves show no readable cycle: the morning is disturbed (NIEDERHORN#74, until 18:00) and the targets on the left edge have just changed level (NIEDERHORN#73). After 16:00, nothing follows the temperature any more. Deduced cause: the camera and its mount move with the housing temperature. Normal, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-76", "start": "2026-10-16T14:00Z", "end": "2026-10-17T01:00Z", "family": "Obstruction", "description": "PWD_IMP_B07_016_C09 alone: at times its recognition error jumps almost to the maximum and the measurement is rejected, or, just under the threshold, its corr_x or corr_y makes a one-measurement spike, then comes back; its neighbours do not move. Cause seen on the 15:00 thumbnail: leaves cover the spot; it is the foreground plant, shaken by the wind, which, according to the expert, passes in front of this target. The structure does not move: ignore this target's curve over the range.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-77", "start": "2026-10-16T16:00Z", "end": "2026-10-16T18:00Z", "family": "Obstruction", "description": "A single measurement: e02, e06, e09, PWD_IMP_B07_016_C09 are rejected and missing from the corrected curves; the references stay intact. Remaining under the threshold, PWD_RMP_B17_026_C09 makes a one-measurement jump on corr_x or corr_y, then comes back. Cause seen: a double-decker passenger train, motion blur, on the 17:00 image. Everything comes back at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-78", "start": "2026-10-16T18:00Z", "end": "2026-10-16T20:00Z", "family": "Obstruction", "description": "A single measurement: e02, e06, e09 are rejected and missing from the corrected curves; the references stay intact. Remaining under the threshold, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09 make a one-measurement jump on corr_x or corr_y, then come back. Cause seen: a passenger train on the far track, on the 19:00 image. Everything comes back at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-79", "start": "2026-10-17T03:00Z", "end": "2026-11-01T00:00Z", "family": "Target issue", "description": "PWD_IMP_B07_018_C09 is rejected almost every night from 17.10, from night to morning: its corrected curve is missing those hours. Its recognition error hovers just above the threshold; on the thumbnails, its night spot is large and saturated, without any obstacle, the same as on the nights when it passes. A problem with the target, at the limit of its threshold under the floodlight, not a movement. Ignore its curve at night; review the threshold or the target.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-80", "start": "2026-10-17T04:00Z", "end": "2026-10-17T18:00Z", "family": "Obstruction", "description": "PWD_IMP_B07_016_C09 alone: at times its recognition error jumps almost to the maximum and the measurement is rejected, or, just under the threshold, its corr_x or corr_y makes a one-measurement spike, then comes back; its neighbours do not move. Cause seen on the 05:00 thumbnail: leaves cover the spot; it is the foreground plant, shaken by the wind, which, according to the expert, passes in front of this target. The structure does not move: ignore this target's curve over the range.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-81", "start": "2026-10-17T12:00Z", "end": "2026-10-17T16:00Z", "family": "Visibility", "description": "At sunrise, over a few measurements, sometimes just one: the recognition error of the references PWD_REF08_C09 to PWD_REF11_C09 rises markedly, without rejection; the compensation is slightly disturbed and the corr_x, corr_y of many targets jump or fluctuate; e06 and e09, on the left, are often rejected. Cause seen on the image of 21.10 at 13:00: the rising sun enters the field just above the road of the references, with halo and reflections across the whole image; it comes back at the same hours on clear days. The structure does not move: do not trust the curves on these measurements.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-82", "start": "2026-10-17T12:00Z", "end": "2026-10-18T00:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (17/10). The housing temperature rises strongly from the morning until 19:00, fastest between 12:00 and 13:00, where it gains markedly. The camera pose follows: from 13:00 to 16:00, the tilt rises strongly and the rotation drops strongly, then both come back at once at 17:00; the pan rises strongly until 17:00 and goes back down until about 21:00; the scale rises strongly until 19:00 and only comes back slowly, during the night. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_RMP_B12_018_C09, PWD_IMP_B07_018_C09, PWD_RMP_B12_017_C09 and PWD_IMP_B07_017_C09 in the centre and on the right drops strongly, that of e02, e10, e06 and e09 on the left of the image rises markedly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_RMP_B12_017_C09, PWD_IMP_B07_017_C09 and PWD_RMP_B15_018_C09, it drops for e02, e09 and e15. The targets do not quite move as one block: against the overall movement, the residual of those that depart from it most, small in the morning, grows markedly during the day. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves also fluctuate: the step from one measurement to the next is much larger than at night on the pan, the tilt and the rotation, much larger on the corr_x of the targets; the recognition error of the targets, however, does not rise (it drops a little). The curves return to their night level around 23:00. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-83", "start": "2026-10-18T06:00Z", "end": "2026-10-18T10:00Z", "family": "Obstruction", "description": "PWD_IMP_B07_016_C09 alone: without any rejection, its corr_x and corr_y at times make a one-measurement spike, just under the threshold, then come back; its neighbours do not move. Cause seen on the 07:00 thumbnail: the tip of a leaf touches the spot; it is the foreground plant, shaken by the wind, which, according to the expert, passes in front of this target. The structure does not move: ignore this target's curve over the range.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-84", "start": "2026-10-18T12:00Z", "end": "2026-10-18T14:00Z", "family": "Visibility", "description": "At sunrise, over a few measurements, sometimes just one: the recognition error of the references PWD_REF08_C09 to PWD_REF11_C09 rises markedly, without rejection; the compensation is slightly disturbed and the corr_x, corr_y of many targets jump or fluctuate; e06 and e09, on the left, are often rejected. Cause seen on the image of 21.10 at 13:00: the rising sun enters the field just above the road of the references, with halo and reflections across the whole image; it comes back at the same hours on clear days. The structure does not move: do not trust the curves on these measurements.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-85", "start": "2026-10-18T12:00Z", "end": "2026-10-19T00:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (18/10). The housing temperature rises strongly from the morning until 16:00, fastest between 12:00 and 13:00, where it gains markedly. The camera pose follows: from 13:00 to 15:00, the tilt rises strongly and the rotation drops strongly, then both come back at once at 17:00; the pan rises markedly until 17:00 and goes back down until about 19:00; the scale rises strongly until 19:00 and only comes back slowly, during the night. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B07_017_C09 and PWD_RMP_B12_017_C09 in the centre and on the right drops strongly, that of e02, e06, PWD_RMP_B17_026_C09 and PWD_RMP_B15_018_C09 rises markedly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_RMP_B12_017_C09, PWD_IMP_B07_017_C09 and PWD_RMP_B15_018_C09, it drops for e02, e09 and e15. The targets do not quite move as one block: against the overall movement, the residual of those that depart from it most, small in the morning, grows strongly during the day. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves also fluctuate: the step from one measurement to the next is far larger than at night on the pan, the tilt and the rotation, much larger on the corr_x of the targets; the recognition error of the targets, however, does not rise (it drops a little). The curves return to their night level around 23:00. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-86", "start": "2026-10-18T20:00Z", "end": "2026-10-18T22:00Z", "family": "Obstruction", "description": "PWD_IMP_B07_016_C09 alone: at times its recognition error jumps almost to the maximum and the measurement is rejected, or, just under the threshold, its corr_x or corr_y makes a one-measurement spike, then comes back; its neighbours do not move. Cause seen on the 21:00 thumbnail: leaves cover the spot, which can no longer be seen; it is the foreground plant, shaken by the wind, which, according to the expert, passes in front of this target. The structure does not move: ignore this target's curve over the range.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-87", "start": "2026-10-19T05:00Z", "end": "2026-10-19T22:00Z", "family": "Obstruction", "description": "PWD_IMP_B07_016_C09 alone: at times its recognition error jumps almost to the maximum and the measurement is rejected, or, just under the threshold, its corr_x or corr_y makes a one-measurement spike, then comes back; its neighbours do not move. Cause seen on the 13:00 and 15:00 thumbnails: the tips of leaves touch the spot; it is the foreground plant, shaken by the wind, which, according to the expert, passes in front of this target. The structure does not move: ignore this target's curve over the range.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-88", "start": "2026-10-19T09:00Z", "end": "2026-10-19T11:00Z", "family": "No data", "description": "One measurement is missing for all the sensors, references and targets: one point absent on all the curves. The station metrics are also missing at that hour, and there is no image; normal voltage before and after. The curves resume at the next measurement without a jump. The same gap falls at the same moment on the other stations measuring at that time (CLARIDEN, FLORIDA, JUNGFRAU, LENZSPITZE, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a station failure; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-89", "start": "2026-10-19T11:00Z", "end": "2026-10-19T15:00Z", "family": "Visibility", "description": "At sunrise, over a few measurements, sometimes just one: the recognition error of the references PWD_REF08_C09 to PWD_REF11_C09 rises markedly, without rejection; the compensation is slightly disturbed and the corr_x, corr_y of many targets jump or fluctuate; e06 and e09, on the left, are often rejected. Cause seen on the image of 21.10 at 13:00: the rising sun enters the field just above the road of the references, with halo and reflections across the whole image; it comes back at the same hours on clear days. The structure does not move: do not trust the curves on these measurements.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-90", "start": "2026-10-19T11:00Z", "end": "2026-10-20T00:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (19/10). The housing temperature rises strongly from the morning until 19:00, fastest between 13:00 and 14:00, where it gains markedly. The camera pose follows: from 12:00 to 16:00, the tilt rises strongly and the rotation drops strongly, then both come back at once at 17:00; the pan rises markedly until 17:00 and goes back down until about 19:00; the scale rises strongly until 19:00 and only comes back slowly, during the night. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B07_017_C09 and PWD_RMP_B12_017_C09 in the centre and on the right drops strongly, that of e02, e06, PWD_RMP_B17_026_C09 and PWD_RMP_B15_018_C09 rises markedly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_RMP_B12_017_C09, PWD_RMP_B15_018_C09 and PWD_IMP_B07_017_C09, it drops for PWD_RMP_B12_019_C09, e15 and e10. The targets do not quite move as one block: against the overall movement, the residual of those that depart from it most, small in the morning, grows strongly during the day. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves also fluctuate: the step from one measurement to the next is far larger than at night on the pan, the tilt and the rotation, much larger on the corr_x of the targets; the recognition error of the targets, however, does not rise (it drops a little). The curves return to their night level around 23:00. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-91", "start": "2026-10-19T20:00Z", "end": "2026-10-19T22:00Z", "family": "No data", "description": "One measurement is missing for all the sensors, references and targets: one point absent on all the curves. The station metrics are also missing at that hour, and there is no image; normal voltage before and after. The curves resume at the next measurement without a jump. The same gap falls at the same moment on the other stations measuring at that time (CLARIDEN, FLORIDA, JUNGFRAU, LENZSPITZE, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a station failure; it is not established. The curves are missing over the range; nothing to do on the station. The hourly metrics of BREITHORN, MICHIGAN and NEBRASKA are also missing at 21:00.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-92", "start": "2026-10-20T05:00Z", "end": "2026-10-20T13:00Z", "family": "Obstruction", "description": "PWD_IMP_B07_016_C09 alone: at times its recognition error jumps almost to the maximum and the measurement is rejected, or, just under the threshold, its corr_x or corr_y makes a one-measurement spike, then comes back; its neighbours do not move. Cause: the foreground plant, shaken by the wind, passes in front of the target; on the 07:00 and 09:00 thumbnails, the tip of a leaf touches the spot, which looks cut off. The structure does not move: ignore this target's curve over the range.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-93", "start": "2026-10-20T11:00Z", "end": "2026-10-20T13:00Z", "family": "Obstruction", "description": "A single measurement: e02, e06, e09, e10, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_025_C09, e14, PWD_RMP_B15_019_C09, PWD_IMP_B07_017_C09, PWD_IMP_B07_016_C09 are rejected and missing from the corrected curves; the references stay intact. Remaining under the threshold, e15, PWD_RMP_B12_020_C09, PWD_RMP_B15_020_C09, PWD_RMP_B12_019_C09, PWD_RMP_B12_018_C09, PWD_RMP_B15_018_C09 make a one-measurement jump on corr_x or corr_y, then come back. Cause seen: a dark band cutting across the tracks on the 12:00 image, a train in the dim dawn light. Everything comes back at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-94", "start": "2026-10-20T12:00Z", "end": "2026-10-20T14:00Z", "family": "Visibility", "description": "At sunrise, over a few measurements, sometimes just one: the recognition error of the references PWD_REF08_C09 to PWD_REF11_C09 rises markedly, without rejection; the compensation is slightly disturbed and the corr_x, corr_y of many targets jump or fluctuate; e06 and e09, on the left, are often rejected. Cause seen on the image of 21.10 at 13:00: the rising sun enters the field just above the road of the references, with halo and reflections across the whole image; it comes back at the same hours on clear days. The structure does not move: do not trust the curves on these measurements.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-95", "start": "2026-10-20T12:00Z", "end": "2026-10-20T23:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (20/10). The housing temperature rises strongly from the morning until 15:00, fastest between 13:00 and 14:00, where it gains markedly. The camera pose follows: from 13:00 to 15:00, the tilt rises strongly and the rotation drops strongly, then both come back at once at 17:00; the pan rises strongly until 17:00 and goes back down until about 22:00; the scale rises markedly until 19:00 then comes back in the evening. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B08_025_C09 and PWD_IMP_B07_017_C09 in the centre and on the right drops strongly, that of e06, e02, e13 and PWD_RMP_B17_026_C09 on the left of the image rises markedly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_RMP_B12_017_C09, PWD_IMP_B07_017_C09 and PWD_IMP_B08_025_C09, it drops for e15, e02 and e09. The targets do not quite move as one block: against the overall movement, the residual of those that depart from it most, small in the morning, grows strongly during the day. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves also fluctuate: the step from one measurement to the next is much larger than at night on the pan, the tilt and the rotation, markedly larger on the corr_x of the targets; the recognition error of the targets, however, does not rise (it drops a little). The curves return to their night level around 23:00. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-96", "start": "2026-10-20T16:00Z", "end": "2026-10-20T18:00Z", "family": "Obstruction", "description": "A single measurement: e02, e06, e09 are rejected and missing from the corrected curves; the references stay intact. Remaining under the threshold, PWD_RMP_B17_026_C09, e15 make a one-measurement jump on corr_x or corr_y, then come back. Cause seen: a double-decker passenger train on the far track, on the 17:00 image. Everything comes back at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-97", "start": "2026-10-20T20:00Z", "end": "2026-10-20T22:00Z", "family": "No data", "description": "One measurement is missing for all the sensors, references and targets: one point absent on all the curves. The camera took the 21:00 image and the metrics are present: the measurement was not made or not transmitted. The measurements of CLARIDEN are also missing at that hour, and those of no other station: a common cause is possible, not established. The curves resume at the next measurement without a jump: nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-98", "start": "2026-10-21T12:00Z", "end": "2026-10-21T15:00Z", "family": "Visibility", "description": "At sunrise, over a few measurements, sometimes just one: the recognition error of the references PWD_REF08_C09 to PWD_REF11_C09 rises markedly, without rejection; the compensation is slightly disturbed and the corr_x, corr_y of many targets jump or fluctuate; e06 and e09, on the left, are often rejected. Cause seen on the image of 21.10 at 13:00: the rising sun enters the field just above the road of the references, with halo and reflections across the whole image; it comes back at the same hours on clear days. The structure does not move: do not trust the curves on these measurements.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-99", "start": "2026-10-21T12:00Z", "end": "2026-10-21T23:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (21/10). The housing temperature rises strongly from the morning until 17:00, fastest between 12:00 and 13:00, where it gains strongly. The camera pose follows: from 13:00 to 16:00, the tilt rises strongly and the rotation drops strongly, then both come back at once at 17:00; the pan rises strongly until 17:00 and goes back down until about 22:00; the scale rises strongly until 17:00 then comes back in the evening. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B07_017_C09 and PWD_RMP_B12_020_C09 drops strongly, that of e02, e06, PWD_RMP_B17_026_C09 and e13 on the left of the image rises strongly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_RMP_B12_017_C09, PWD_RMP_B15_018_C09 and PWD_IMP_B07_016_C09, it drops for e13, e02 and e09. The targets do not quite move as one block: against the overall movement, the residual of those that depart from it most, small in the morning, grows markedly during the day. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves also fluctuate: the step from one measurement to the next is much larger than at night on the pan, the tilt and the rotation, much larger on the corr_x of the targets; the recognition error of the targets, however, does not rise (it drops a little). The curves return to their night level around 23:00. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-100", "start": "2026-10-21T21:00Z", "end": "2026-10-21T23:00Z", "family": "Obstruction", "description": "A single measurement: e02, e06, e09, e10, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_025_C09, e14, e15, PWD_RMP_B15_020_C09, PWD_RMP_B15_019_C09, PWD_RMP_B15_018_C09 are rejected and missing from the corrected curves; the references stay intact. Remaining under the threshold, PWD_RMP_B12_020_C09, PWD_RMP_B12_019_C09, PWD_RMP_B12_018_C09 make a one-measurement jump on corr_x or corr_y, then come back. Cause seen: a passenger train, blurred windows and doors, on the 22:00 image. Everything comes back at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-101", "start": "2026-10-22T12:00Z", "end": "2026-10-22T15:00Z", "family": "Visibility", "description": "At sunrise, over a few measurements, sometimes just one: the recognition error of the references PWD_REF08_C09 to PWD_REF11_C09 rises markedly, without rejection; the compensation is slightly disturbed and the corr_x, corr_y of many targets jump or fluctuate; e06 and e09, on the left, are often rejected. Cause seen on the image of 21.10 at 13:00: the rising sun enters the field just above the road of the references, with halo and reflections across the whole image; it comes back at the same hours on clear days. The structure does not move: do not trust the curves on these measurements.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-102", "start": "2026-10-22T12:00Z", "end": "2026-10-22T22:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (22/10). The housing temperature rises strongly from the morning until 17:00, fastest between 13:00 and 14:00, where it gains strongly. The camera pose follows: from 13:00 to 16:00, the tilt rises strongly and the rotation drops strongly, then both come back at once at 17:00; the pan rises markedly until 17:00 and goes back down until about 19:00; the scale rises strongly until 19:00 and only comes back slowly, during the night. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_RMP_B12_018_C09, PWD_RMP_B12_020_C09, e13 and e10 drops markedly, that of e02, e06, PWD_RMP_B17_026_C09 and PWD_RMP_B12_017_C09 rises markedly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_IMP_B07_017_C09, PWD_IMP_B08_025_C09 and PWD_RMP_B15_018_C09, it drops for e13 and e02. The targets do not quite move as one block: against the overall movement, the residual of those that depart from it most, small in the morning, grows markedly during the day. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves also fluctuate: the step from one measurement to the next is much larger than at night on the pan, the tilt and the rotation, markedly larger on the corr_x of the targets; the recognition error of the targets, however, does not rise (it drops a little). The curves return to their night level around 22:00. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-103", "start": "2026-10-22T15:00Z", "end": "2026-10-22T17:00Z", "family": "Obstruction", "description": "A single measurement: e02 is rejected and missing from the corrected curves; the references stay intact. The other targets do not move. Cause seen: a dark mass covering e02 on the 16:00 thumbnail, like the underside of a wagon. Everything comes back at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-104", "start": "2026-10-22T23:00Z", "end": "2026-10-23T01:00Z", "family": "No data", "description": "One measurement is missing for all the sensors, references and targets: one point absent on all the curves. The station is running (metrics present at that hour, normal voltage before and after); the cause of the gap is not established (measurement not made or not transmitted). The curves resume at the next measurement without a jump: nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-105", "start": "2026-10-23T11:00Z", "end": "2026-10-23T15:00Z", "family": "Obstruction", "description": "PWD_IMP_B07_016_C09 alone: at times its recognition error jumps almost to the maximum and the measurement is rejected, or, just under the threshold, its corr_x or corr_y makes a one-measurement spike, then comes back; its neighbours do not move. Cause: the foreground plant, shaken by the wind, passes in front of the target; on the 12:00 and 13:00 thumbnails, at daybreak, blurred leaves cover the spot, almost invisible. The structure does not move: ignore this target's curve over the range.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-106", "start": "2026-10-23T11:00Z", "end": "2026-10-23T15:00Z", "family": "Visibility", "description": "At sunrise, over a few measurements, sometimes just one: the recognition error of the references PWD_REF08_C09 to PWD_REF11_C09 rises markedly, without rejection; the compensation is slightly disturbed and the corr_x, corr_y of many targets jump or fluctuate; e06 and e09, on the left, are often rejected. Cause seen on the image of 21.10 at 13:00: the rising sun enters the field just above the road of the references, with halo and reflections across the whole image; it comes back at the same hours on clear days. The structure does not move: do not trust the curves on these measurements.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-107", "start": "2026-10-23T12:00Z", "end": "2026-10-23T22:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (23/10). The housing temperature rises strongly from the morning until 18:00, fastest between 13:00 and 14:00, where it gains markedly. The camera pose follows: from 13:00 to 15:00, the tilt rises strongly and the rotation drops strongly, then both come back largely at once at 17:00; the pan rises strongly until 21:00 and goes back down until about 22:00; the scale rises markedly until 19:00 then comes back in the evening. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B07_017_C09 and PWD_RMP_B15_020_C09 in the centre and on the right drops strongly, that of e02, e06, PWD_RMP_B17_026_C09 and e09 on the left of the image rises markedly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_RMP_B12_017_C09 and PWD_RMP_B15_018_C09, it drops for e15, e13 and e02. The targets do not quite move as one block: against the overall movement, the residual of those that depart from it most, small in the morning, grows markedly during the day. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves also fluctuate: the step from one measurement to the next is much larger than at night on the pan, the tilt and the rotation, much larger on the corr_x of the targets; the recognition error of the targets, however, does not rise (it drops a little). The curves return to their night level around 22:00. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-108", "start": "2026-10-23T18:00Z", "end": "2026-10-23T20:00Z", "family": "Obstruction", "description": "A single measurement: e02, e06, e09, e10, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_025_C09, PWD_RMP_B15_020_C09, PWD_IMP_B07_018_C09, PWD_RMP_B15_019_C09, PWD_RMP_B15_018_C09, PWD_IMP_B07_017_C09 are rejected and missing from the corrected curves; the references stay intact. Remaining under the threshold, e13, e14, PWD_RMP_B12_020_C09, PWD_RMP_B12_019_C09, PWD_RMP_B12_018_C09 make a one-measurement jump on corr_x or corr_y, then come back. Cause seen: a double-decker passenger train on the 19:00 image. Everything comes back at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-109", "start": "2026-10-24T12:00Z", "end": "2026-10-24T15:00Z", "family": "Visibility", "description": "At sunrise, over a few measurements, sometimes just one: the recognition error of the references PWD_REF08_C09 to PWD_REF11_C09 rises markedly, without rejection; the compensation is slightly disturbed and the corr_x, corr_y of many targets jump or fluctuate; e06 and e09, on the left, are often rejected. Cause seen on the image of 21.10 at 13:00: the rising sun enters the field just above the road of the references, with halo and reflections across the whole image; it comes back at the same hours on clear days. The structure does not move: do not trust the curves on these measurements.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-110", "start": "2026-10-24T12:00Z", "end": "2026-10-24T23:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (24/10). The housing temperature rises strongly from the morning until 20:00, fastest between 13:00 and 14:00, where it gains strongly. The camera pose follows: from 13:00 to 15:00, the tilt rises strongly and the rotation drops strongly, then both come back largely at once at 17:00; the pan rises markedly until 17:00 and goes back down until about 22:00; the scale rises strongly until 19:00 and only comes back slowly, during the night. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B08_025_C09 and PWD_IMP_B07_017_C09 in the centre and on the right drops strongly, that of e06 on the left of the image rises markedly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_RMP_B15_018_C09 and PWD_IMP_B07_016_C09, it drops for e09, e15 and PWD_RMP_B12_019_C09. The targets do not quite move as one block: against the overall movement, the residual of those that depart from it most, small in the morning, grows strongly during the day. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves also fluctuate: the step from one measurement to the next is much larger than at night on the pan, the tilt and the rotation, markedly larger on the corr_x of the targets; the recognition error of the targets, however, does not rise (it drops a little). The curves return to their night level around 23:00. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-111", "start": "2026-10-24T16:00Z", "end": "2026-10-24T20:00Z", "family": "Obstruction", "description": "Three measurements in a row: PWD_IMP_B07_017_C09, PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_RMP_B12_019_C09, PWD_RMP_B15_018_C09 and PWD_RMP_B15_019_C09 are rejected and missing from the corrected curves; the references and the other targets hold. Cause seen on the 18:00 image: a service van parked on the tracks in the foreground, tailgate open, in front of these targets. Everything comes back when it leaves: the structure does not move, range to ignore for these targets.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-112", "start": "2026-10-25T03:00Z", "end": "2026-10-25T17:00Z", "family": "Visibility", "description": "At night and in the morning, for several hours: the recognition error of many targets rises, many are rejected at times (especially e06, PWD_RMP_B16_026_C09, PWD_IMP_B07_017_C09, e13 and e15, then e10, e09 and PWD_RMP_B12_020_C09) and the others fluctuate; the references hold, higher up on the road. Gradual return to normal in late morning. Probable cause: rain or mist (smaller and weaker spots on the 08:00 thumbnails, without any obstacle). The structure does not move: do not trust the curves over the range.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-113", "start": "2026-10-25T12:00Z", "end": "2026-10-26T00:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (25/10). The housing temperature rises strongly from the morning until 15:00, fastest between 13:00 and 14:00, where it gains strongly. The camera pose follows: from 13:00 to 15:00, the tilt rises strongly and the rotation drops strongly, then both come back largely at once at 17:00; the pan rises markedly until 17:00 and goes back down until about 20:00; the scale rises strongly until 19:00 and only comes back slowly, during the night. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_IMP_B07_017_C09 and PWD_RMP_B15_018_C09 in the centre and on the right drops markedly, that of e13, e06, PWD_RMP_B17_026_C09 and PWD_RMP_B16_026_C09 on the left of the image rises markedly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_RMP_B12_017_C09 and PWD_RMP_B12_020_C09, it drops for e13, e09 and e15. The targets do not quite move as one block: against the overall movement, the residual of those that depart from it most, small in the morning, grows strongly during the day. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves also fluctuate: the step from one measurement to the next is far larger than at night on the pan, the tilt and the rotation, markedly larger on the corr_x of the targets; the recognition error of the targets, however, does not rise (it drops a little). The curves return to their night level around 22:00. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-114", "start": "2026-10-26T03:00Z", "end": "2026-10-26T05:00Z", "family": "Obstruction", "description": "PWD_IMP_B07_016_C09 alone: without any rejection, its corr_x and corr_y at times make a one-measurement spike, just under the threshold, then come back; its neighbours do not move. Cause seen on the 04:00 thumbnail: the tips of leaves touch the spot; it is the foreground plant, shaken by the wind, which, according to the expert, passes in front of this target. The structure does not move: ignore this target's curve over the range.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-115", "start": "2026-10-26T12:00Z", "end": "2026-10-26T14:00Z", "family": "Obstruction", "description": "PWD_IMP_B07_016_C09 alone: at times its recognition error jumps almost to the maximum and the measurement is rejected, or, just under the threshold, its corr_x or corr_y makes a one-measurement spike, then comes back; its neighbours do not move. Cause seen on the 13:00 thumbnail: still dark, the spot can no longer be seen, with blurred leaves in front of it; it is the foreground plant, shaken by the wind, which, according to the expert, passes in front of this target. The structure does not move: ignore this target's curve over the range.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-116", "start": "2026-10-26T13:00Z", "end": "2026-10-26T16:00Z", "family": "Visibility", "description": "At daybreak, one measurement: e06 is rejected and missing from its corrected curve, the recognition error of one reference, PWD_REF10_C09, rises, the camera pose makes a one-measurement jump (tilt, rotation) and the corr_x of PWD_IMP_B07_018_C09 and PWD_IMP_B08_024_C09 departs a little; the next measurement is missing for all the sensors. On the 14:00 image, the sky is dazzling behind the clouds above the references, with no visible sun: probable cause, the daybreak light, like the sunny mornings, but weaker. The structure does not move: do not trust the curves on this measurement.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-117", "start": "2026-10-26T14:00Z", "end": "2026-10-26T16:00Z", "family": "No data", "description": "One measurement is missing for all the sensors, references and targets: one point absent on all the curves. The station metrics are also missing at that hour, and there is no image; normal voltage before and after. The curves resume at the next measurement without a jump. The same gap falls at the same moment on the other stations measuring at that time (CLARIDEN, FLORIDA, JUNGFRAU, LENZSPITZE, NORDEND, SNCF01), and their metrics are also missing at the same minutes: a common cause outside the station (transmission or reception of the data), not a station failure; it is not established. The curves are missing over the range; nothing to do on the station. The hourly metrics of BREITHORN, MICHIGAN and NEBRASKA are also missing at 15:00.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-118", "start": "2026-10-26T21:00Z", "end": "2026-10-26T23:00Z", "family": "Obstruction", "description": "A single measurement, in the evening: e02 alone is rejected and missing from its corrected curve; its neighbours and the references do not move. Cause seen on the 22:00 image: a blurred band cuts across the far tracks, a passing train, and the spot of e02 has disappeared on the thumbnail. Back to normal at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-119", "start": "2026-10-27T07:00Z", "end": "2026-10-27T10:00Z", "family": "Obstruction", "description": "PWD_IMP_B07_016_C09 alone: at times its recognition error jumps almost to the maximum and the measurement is rejected, or, just under the threshold, its corr_x or corr_y makes a one-measurement spike, then comes back; its neighbours do not move. Cause seen on the 08:00 thumbnail: leaves touch the spot; it is the foreground plant, shaken by the wind, which, according to the expert, passes in front of this target. The structure does not move: ignore this target's curve over the range.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-120", "start": "2026-10-27T11:00Z", "end": "2026-10-27T13:00Z", "family": "Obstruction", "description": "A single measurement: e02, e06, e09, PWD_RMP_B17_026_C09, PWD_RMP_B12_019_C09, PWD_IMP_B07_018_C09 are rejected and missing from the corrected curves; the references stay intact. Remaining under the threshold, PWD_RMP_B16_026_C09 makes a one-measurement jump on corr_x or corr_y, then comes back. Cause seen: a dark band with a right edge cutting across the scene on the 12:00 image, a train in the dim dawn light. Everything comes back at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-121", "start": "2026-10-27T12:00Z", "end": "2026-10-27T16:00Z", "family": "Visibility", "description": "At sunrise, over a few measurements, sometimes just one: the recognition error of the references PWD_REF08_C09 to PWD_REF11_C09 rises markedly, without rejection; the compensation is slightly disturbed and the corr_x, corr_y of many targets jump or fluctuate; e06 and e09, on the left, are often rejected. Cause seen on the image of 21.10 at 13:00: the rising sun enters the field just above the road of the references, with halo and reflections across the whole image; it comes back at the same hours on clear days. The structure does not move: do not trust the curves on these measurements.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-122", "start": "2026-10-27T12:00Z", "end": "2026-10-27T22:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (27/10). The housing temperature rises strongly from the morning until 20:00, fastest between 13:00 and 14:00, where it gains markedly. The camera pose follows: from 13:00 to 15:00, the tilt rises strongly and the rotation drops strongly, then both come back largely at once at 17:00; the pan rises strongly until 17:00 and goes back down until about 22:00; the scale rises markedly until 20:00 and only comes back slowly, during the night. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_RMP_B12_018_C09, PWD_IMP_B07_018_C09, PWD_RMP_B12_017_C09 and PWD_IMP_B07_017_C09 in the centre and on the right drops markedly, that of e02, e06, e10 and PWD_RMP_B17_026_C09 on the left of the image rises markedly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_RMP_B12_017_C09, it drops for e02, e15 and e13. The targets do not quite move as one block: against the overall movement, the residual of those that depart from it most, small in the morning, grows strongly during the day. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves also fluctuate: the step from one measurement to the next is much larger than at night on the pan, the tilt and the rotation, markedly larger on the corr_x of the targets; the recognition error of the targets, however, does not rise (it drops a little). The curves return to their night level around 22:00. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-123", "start": "2026-10-28T11:00Z", "end": "2026-10-28T13:00Z", "family": "No data", "description": "One measurement is missing for all the sensors, references and targets: one point absent on all the curves. The camera took the 12:00 image and the metrics are present: the measurement was not made or not transmitted; cause not established. The curves resume at the next measurement without a jump: nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-124", "start": "2026-10-28T13:00Z", "end": "2026-10-28T15:00Z", "family": "Obstruction", "description": "A single measurement: e02, e06, e09, e10, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_025_C09, e14, e15, PWD_RMP_B15_020_C09, PWD_IMP_B07_018_C09, PWD_RMP_B15_019_C09, PWD_RMP_B15_018_C09 are rejected and missing from the corrected curves; the references stay intact. Remaining under the threshold, e13, PWD_RMP_B12_020_C09, PWD_RMP_B12_019_C09, PWD_RMP_B12_018_C09, PWD_RMP_B12_017_C09 make a one-measurement jump on corr_x or corr_y, then come back. Cause seen: a dark band cutting across the tracks on the 14:00 image, a train in the dim dawn light. Everything comes back at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-125", "start": "2026-10-28T14:00Z", "end": "2026-10-28T22:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (28/10). The housing temperature rises markedly from the morning until 18:00, fastest between 17:00 and 18:00, where it gains markedly. The camera pose follows: the tilt drops a little at 20:00 and comes back at 22:00; the rotation drops a little at 16:00 and comes back at 18:00; the pan rises markedly until 18:00 and goes back down until about 22:00; the scale rises markedly until 19:00 then comes back in the evening. This day, the cycle starts late, with the temperature rise between 15:00 and 18:00; the tilt drops instead of rising and the rotation hardly moves. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_RMP_B12_018_C09, PWD_IMP_B07_018_C09, PWD_RMP_B12_017_C09 and PWD_RMP_B15_018_C09 in the centre and on the right drops markedly, that of e06, e02, PWD_RMP_B17_026_C09 and e09 on the left of the image rises strongly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_IMP_B07_017_C09 and PWD_RMP_B15_018_C09, it drops for e15, e02 and e13. The targets do not quite move as one block: against the overall movement, the residual of those that depart from it most, small in the morning, grows strongly during the day. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves also fluctuate: the step from one measurement to the next is markedly larger than at night on the pan, the tilt and the rotation, a little larger on the corr_x of the targets; the recognition error of the targets, however, does not rise (it drops a little). The curves return to their night level around 22:00. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-126", "start": "2026-10-28T18:00Z", "end": "2026-10-28T20:00Z", "family": "Displacement", "description": "A single measurement: the reference PWD_REF11_C09 is rejected (its raw position jumps) and excluded from the compensation; a few targets (e02, e06, PWD_RMP_B12_017_C09) make a one-measurement jump then come back. Nothing hides the reference on the 19:00 image: cause not established. The return is immediate: not a movement of the structure, point to ignore.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-127", "start": "2026-10-29T00:00Z", "end": "2026-10-29T16:00Z", "family": "Visibility", "description": "At night and in the morning, for several hours: the recognition error of many targets rises, many are rejected at times (especially e06, PWD_RMP_B16_026_C09, PWD_IMP_B07_017_C09, e13 and e15, then e10, e09 and PWD_RMP_B12_020_C09) and the others fluctuate; the references hold, higher up on the road. Gradual return to normal in late morning. Probable cause: rain or mist (spots markedly smaller and weaker on the 10:00 thumbnails, whole image noisy, without any obstacle). The structure does not move: do not trust the curves over the range.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-128", "start": "2026-10-29T12:00Z", "end": "2026-10-29T14:00Z", "family": "Visibility", "description": "At sunrise, over a few measurements, sometimes just one: the recognition error of the references PWD_REF08_C09 to PWD_REF11_C09 rises markedly, without rejection; the compensation is slightly disturbed and the corr_x, corr_y of many targets jump or fluctuate; e06 and e09, on the left, are often rejected. Cause seen on the image of 21.10 at 13:00: the rising sun enters the field just above the road of the references, with halo and reflections across the whole image; it comes back at the same hours on clear days. The structure does not move: do not trust the curves on these measurements.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-129", "start": "2026-10-29T12:00Z", "end": "2026-10-29T22:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (29/10). The housing temperature rises strongly from the morning until 18:00, fastest between 13:00 and 14:00, where it gains markedly. The camera pose follows: from 13:00 to 16:00, the tilt rises markedly and the rotation drops strongly, then both come back at once at 17:00; the pan rises markedly until 17:00 and goes back down until about 18:00; the scale rises strongly until 18:00 and only comes back slowly, during the night. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_IMP_B07_018_C09, PWD_RMP_B12_020_C09, PWD_RMP_B12_019_C09 and PWD_RMP_B12_018_C09 drops strongly, that of e06, PWD_RMP_B17_026_C09, e02 and e09 on the left of the image rises markedly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_RMP_B12_017_C09 and PWD_IMP_B07_016_C09, it drops for e09, e02 and e15. The targets do not quite move as one block: against the overall movement, the residual of those that depart from it most, small in the morning, grows strongly during the day. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves also fluctuate: the step from one measurement to the next is markedly larger than at night on the pan, the tilt and the rotation, markedly larger on the corr_x of the targets; the recognition error of the targets, however, does not rise (it drops a little). The curves return to their night level around 22:00. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-130", "start": "2026-10-29T20:00Z", "end": "2026-10-29T23:00Z", "family": "Obstruction", "description": "Two measurements: e06, e09, e10, e13, PWD_RMP_B16_026_C09, PWD_RMP_B12_019_C09, PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09 and PWD_RMP_B15_018_C09 are rejected at the first, e02, PWD_RMP_B16_026_C09 and PWD_IMP_B07_018_C09 at the second; the references hold. Cause seen on the 21:00 image: lit insects fly in front of the lens, as blurred spots on the tracks. Back to normal afterwards: the structure does not move, points to ignore.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-131", "start": "2026-10-30T01:00Z", "end": "2026-11-01T00:00Z", "family": "Displacement", "description": "All at once, in the night, at the 02:00 measurement: the left-edge targets e14 and e15 jump on corr_x and corr_y and stay offset, e10 also jumps; the recognition error of e09, e10, e14, e15 and PWD_RMP_B16_026_C09 changes level at the same instant and stays there. PWD_RMP_B16_026_C09 is rejected at almost every measurement until the end of the batch, e10 often; e09, e10 and e13 come back in part towards their level from before 16.10 in the following hours. The references and the other targets do not move. Nothing visible on the thumbnails or on the 02:00 image. Cause not established (something changed around these targets, or they moved). To check on site; monitor these targets.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-132", "start": "2026-10-30T01:00Z", "end": "2026-11-01T00:00Z", "family": "Target issue", "description": "PWD_RMP_B16_026_C09 is rejected at every measurement from 02:00 on 30.10, until the end of the batch, and still at almost all those of 01 to 03.11 that follow the batch: its corrected curve is missing. At this measurement, its recognition error goes from a little under its threshold to markedly above it, and stays there, by day as by night, whatever the weather; before 29.10 it was only rejected at the moments shared with its neighbours (trains, rain, rising sun). The change comes with the jump of the left-edge targets at the same measurement (NIEDERHORN#131). On the thumbnails, its spot stays the same, small and sharp next to a large neighbour, without any obstacle. Cause not established (something changed around the target, or it moved). Ignore its curve; check the target on site, then review its threshold.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-133", "start": "2026-10-30T03:00Z", "end": "2026-10-30T07:00Z", "family": "Obstruction", "description": "PWD_IMP_B07_016_C09 alone: at times its recognition error jumps almost to the maximum and the measurement is rejected, or, just under the threshold, its corr_x or corr_y makes a one-measurement spike, then comes back; its neighbours do not move. Cause seen on the 04:00 thumbnail: leaves cover the spot; it is the foreground plant, shaken by the wind, which, according to the expert, passes in front of this target. The structure does not move: ignore this target's curve over the range.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-134", "start": "2026-10-30T03:00Z", "end": "2026-11-01T00:00Z", "family": "Target issue", "description": "e10 is often rejected from 04:00 on 30.10, until the end of the batch, especially at night and in the morning, and more often still, at most measurements, on 01 to 03.11 that follow the batch: its corrected curve is missing at times. Since the jump of the left-edge targets at 02:00 (NIEDERHORN#131), its recognition error hovers around its threshold, just below or just above, whereas it stayed a little under it before, whatever the weather; before, it was only rejected at the moments shared with its neighbours. On the thumbnails, its spot, wide and saturated at night, is the same as before, without any obstacle. Cause not established, the same as for PWD_RMP_B16_026_C09. Do not trust its isolated points; check the target on site, then review its threshold.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-135", "start": "2026-10-30T12:00Z", "end": "2026-10-30T14:00Z", "family": "Visibility", "description": "At sunrise, over a few measurements, sometimes just one: the recognition error of the references PWD_REF08_C09 to PWD_REF11_C09 rises markedly, without rejection; the compensation is slightly disturbed and the corr_x, corr_y of many targets jump or fluctuate; e06 and e09, on the left, are often rejected. Cause seen on the image of 21.10 at 13:00: the rising sun enters the field just above the road of the references, with halo and reflections across the whole image; it comes back at the same hours on clear days. The structure does not move: do not trust the curves on these measurements.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-136", "start": "2026-10-30T12:00Z", "end": "2026-10-30T22:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (30/10). The housing temperature rises strongly from the morning until 15:00, fastest between 13:00 and 14:00, where it gains strongly. The camera pose follows: from 13:00 to 15:00, the tilt rises strongly and the rotation drops strongly, then both come back at once at 16:00; the pan rises markedly until 21:00 and goes back down until about 22:00; the scale rises a little until 21:00 then comes back in the evening. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B07_017_C09 and PWD_RMP_B12_017_C09 in the centre and on the right drops markedly, that of e02, e06, PWD_RMP_B17_026_C09 and e14 on the left of the image rises markedly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_RMP_B12_017_C09, PWD_IMP_B07_017_C09 and PWD_RMP_B15_018_C09, it drops for e15, e13 and e02. The targets do not quite move as one block: against the overall movement, the residual of those that depart from it most, small in the morning, grows markedly during the day. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves also fluctuate: the step from one measurement to the next is markedly larger than at night on the pan, the tilt and the rotation, markedly larger on the corr_x of the targets; the recognition error of the targets, however, does not rise (it drops a little). The curves return to their night level around 22:00. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-137", "start": "2026-10-31T10:00Z", "end": "2026-10-31T12:00Z", "family": "Obstruction", "description": "A single measurement: e02, e06, e09, e10, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_025_C09, e15, PWD_RMP_B12_019_C09, PWD_IMP_B07_018_C09, PWD_RMP_B15_019_C09, PWD_IMP_B07_017_C09, PWD_IMP_B07_016_C09 are rejected and missing from the corrected curves; the references stay intact. Remaining under the threshold, e13, e14, PWD_RMP_B12_020_C09, PWD_RMP_B15_020_C09, PWD_RMP_B12_018_C09, PWD_RMP_B15_018_C09 make a one-measurement jump on corr_x or corr_y, then come back. Cause seen: a freight train, wagon numbers legible, on the 11:00 image. Everything comes back at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-138", "start": "2026-10-31T11:00Z", "end": "2026-10-31T15:00Z", "family": "Visibility", "description": "At sunrise: the reference PWD_REF11_C09 goes above its threshold and is excluded from the compensation for one measurement; the other references also rise; the corr_x, corr_y of many targets jump together then come back, e06 and e09 are rejected. Cause seen on the 13:00 image: the sun, in the field just above PWD_REF11_C09, dazzles the scene. This is not a movement: do not trust the curves on these measurements.", "review": "2026-11-04"}
|
||||
{"id": "NIEDERHORN-139", "start": "2026-10-31T12:00Z", "end": "2026-10-31T23:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (31/10). The housing temperature rises strongly from the morning until 18:00, fastest between 13:00 and 14:00, where it gains strongly. The camera pose follows: from 13:00 to 15:00, the tilt rises strongly and the rotation drops strongly, then both come back largely at once at 17:00; the pan rises markedly until 17:00 and goes back down until about 20:00; the scale rises strongly until 18:00 then comes back in the evening. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_RMP_B12_017_C09 and PWD_IMP_B07_017_C09 in the centre and on the right drops strongly, that of e02, e06, PWD_RMP_B17_026_C09 and e09 on the left of the image rises markedly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_RMP_B12_017_C09, PWD_RMP_B15_018_C09 and PWD_IMP_B07_017_C09, it drops for e02, e13 and e15. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves also fluctuate: the step from one measurement to the next is much larger than at night on the pan, the tilt and the rotation, markedly larger on the corr_x of the targets; the recognition error of the targets, however, does not rise (it drops a little). The curves return to their night level around 23:00. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-04"}
|
||||