diff --git a/auto/NORDEND.jsonl b/auto/NORDEND.jsonl index 66282d6..1fa9932 100644 --- a/auto/NORDEND.jsonl +++ b/auto/NORDEND.jsonl @@ -240,4 +240,4 @@ {"id": "NORDEND-240", "start": "2026-11-07T06:30Z", "end": "2026-11-07T14:00Z", "family": "Thermal displacement", "description": "Camera thermal cycle, until the end of the batch: in the morning, when the housing warms up (less than the days before), the camera turns: the pan drops markedly, the tilt rises markedly, the rotation drops, the scale increases; at the end of the batch it has not yet come back. The compensation absorbs it poorly: the corr_x of PR18 and PR13 dips a little, PR16 a little less; the corr_y of PR06 rises markedly, that of PR16 and PR15 a little. The spikes until 10:45 come from CTR03 (separate label). Deduced cause: the pose follows the housing temperature, and the rock face does not move with temperature. The structure is not moving, nothing to do.", "analysis": "NORDEND_2026-11-04T2112_2026-11-07T1412"} {"id": "NORDEND-241", "start": "2026-11-07T11:15Z", "end": "2026-11-07T11:45Z", "family": "Obstruction", "description": "PR04, whose error_value has been rising since late morning, is rejected for one measurement at 11:30, markedly above the threshold: one point is missing, its neighbours stay measured and the next point has come back. Deduced cause: the thread of the cobweb, which passes over the group of targets that day (bright band on the 14:00 image); nothing is visible on its 11:00 and 12:00 thumbnails. Ignore this point; the structure is not moving.", "analysis": "NORDEND_2026-11-04T2112_2026-11-07T1412"} {"id": "NORDEND-242", "start": "2026-11-07T13:45Z", "end": "2026-11-07T14:00Z", "family": "Obstruction", "description": "PR07 is rejected at 14:00, the last measurement of the batch, just above its threshold: one point is missing. On the 14:00 image, a bright, blurry band (a lit thread of the cobweb) goes down through the group of targets very close to it and lights the background of its thumbnail. Cause seen on the image. Ignore this point; the structure is not moving.", "analysis": "NORDEND_2026-11-04T2112_2026-11-07T1412"} -{"id": "NORDEND-243", "start": "2026-11-05T11:45Z", "end": "2026-11-05T12:15Z", "family": "Displacement", "description": "For the duration of one measurement, at 12:00, in the middle of the camera thermal cycle (labelled separately), the pose makes a jolt: the rotation and the tilt jump then come back at the next measurement, and the raw positions of all sensors, references included, jump together in the image then come back, not quite by the same amount (CTR04 a little apart from the targets). The compensation does not quite erase it: the corr_y of PR01, PR10, PR02, PR04 and PR07 drops markedly, PR11, PR09 and PR17 a little, and the corr_x of PR01 and PR02 rises a little; everything comes back at 12:15. No reference is lost (all three stay in the compensation) and no target is rejected apart from CTR01, rejected as usual; the error_value of PR01, PR09 and CTR02, which comes and goes all morning with no effect on the curves, does nothing more here. On the 12:00 image, sunny day, the targets in shadow, nothing in front of them. Cause not established: a jolt of the camera or of its mount, deduced from the pose. This is not a movement of the structure; points to ignore, the camera is to be watched if it repeats.", "analysis": "NORDEND_2026-11-05T0600_2026-11-05T1200"} +{"id": "NORDEND-243", "start": "2026-11-05T11:45Z", "end": "2026-11-05T12:15Z", "family": "Displacement", "description": "For the duration of one measurement, at 12:00, in the middle of the camera thermal cycle (labelled separately), the pose makes a jolt: the rotation and the tilt jump then come back at the next measurement, and the raw positions of all sensors, references included, jump together in the image then come back, not quite by the same amount (CTR04 a little apart from the targets). The compensation does not quite erase it: the corr_y of PR01, PR10, PR02, PR04 and PR07 drops markedly, PR11, PR09 and PR17 a little, and the corr_x of PR01 and PR02 rises a little; everything comes back at 12:15. No reference is lost (all three stay in the compensation) and no target is rejected apart from CTR01, rejected as usual; the error_value of the reference CTR02 and of PR01, which comes and goes all morning with no effect on the curves, rises clearly at 12:00 with the jolt, under the threshold, and comes back at 12:15; that of PR09 barely moves. On the 12:00 image, sunny day, the targets in shadow, nothing in front of them. Cause not established: a jolt of the camera or of its mount, deduced from the pose. This is not a movement of the structure; points to ignore, the camera is to be watched if it repeats.", "analysis": "NORDEND_2026-11-05T0600_2026-11-05T1200"} diff --git a/auto/analyses/NORDEND_2026-11-05T0600_2026-11-05T1200/labels.jsonl b/auto/analyses/NORDEND_2026-11-05T0600_2026-11-05T1200/labels.jsonl index 384ad90..299bd03 100644 --- a/auto/analyses/NORDEND_2026-11-05T0600_2026-11-05T1200/labels.jsonl +++ b/auto/analyses/NORDEND_2026-11-05T0600_2026-11-05T1200/labels.jsonl @@ -1 +1 @@ -{"start": "2026-11-05T11:45Z", "end": "2026-11-05T12:15Z", "family": "Displacement", "description": "For the duration of one measurement, at 12:00, in the middle of the camera thermal cycle (labelled separately), the pose makes a jolt: the rotation and the tilt jump then come back at the next measurement, and the raw positions of all sensors, references included, jump together in the image then come back, not quite by the same amount (CTR04 a little apart from the targets). The compensation does not quite erase it: the corr_y of PR01, PR10, PR02, PR04 and PR07 drops markedly, PR11, PR09 and PR17 a little, and the corr_x of PR01 and PR02 rises a little; everything comes back at 12:15. No reference is lost (all three stay in the compensation) and no target is rejected apart from CTR01, rejected as usual; the error_value of PR01, PR09 and CTR02, which comes and goes all morning with no effect on the curves, does nothing more here. On the 12:00 image, sunny day, the targets in shadow, nothing in front of them. Cause not established: a jolt of the camera or of its mount, deduced from the pose. This is not a movement of the structure; points to ignore, the camera is to be watched if it repeats."} +{"start": "2026-11-05T11:45Z", "end": "2026-11-05T12:15Z", "family": "Displacement", "description": "For the duration of one measurement, at 12:00, in the middle of the camera thermal cycle (labelled separately), the pose makes a jolt: the rotation and the tilt jump then come back at the next measurement, and the raw positions of all sensors, references included, jump together in the image then come back, not quite by the same amount (CTR04 a little apart from the targets). The compensation does not quite erase it: the corr_y of PR01, PR10, PR02, PR04 and PR07 drops markedly, PR11, PR09 and PR17 a little, and the corr_x of PR01 and PR02 rises a little; everything comes back at 12:15. No reference is lost (all three stay in the compensation) and no target is rejected apart from CTR01, rejected as usual; the error_value of the reference CTR02 and of PR01, which comes and goes all morning with no effect on the curves, rises clearly at 12:00 with the jolt, under the threshold, and comes back at 12:15; that of PR09 barely moves. On the 12:00 image, sunny day, the targets in shadow, nothing in front of them. Cause not established: a jolt of the camera or of its mount, deduced from the pose. This is not a movement of the structure; points to ignore, the camera is to be watched if it repeats."}