auto: the long labels requalified as analyses like the others, <STATION>_<start>_<end>/ with request.json (ex long-labels/<STATION>/); their labels carry the analysis; work/ out of git
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
ddb17c2189
commit
764af7d8ec
132 files changed
+125
-9256
No files matched your search
+2
-2
@@ -1,5 +1,5 @@
|
||||
{"id": "CLARIDEN-1", "start": "2026-10-01T00:00Z", "end": "2026-11-01T00:00Z", "family": "Target issue", "description": "The target P-300-B is rejected at every measurement of the batch: its recognition error stays almost at 1, its corrected curve is missing over the whole month. This has lasted since 29 September in the late afternoon, the time when the recognition error of other targets, including its neighbor P-301-B, also changes level all at once: a station setting changed that day. On the thumbnails (the 1st, the 15th and the 31st), the prism spot is sharp and bright, but next to the position where the system looks for it: the target seems badly configured or badly positioned, not hidden. Curve to ignore; correct the position of the target in the configuration or check the prism.", "review": "2026-11-17"}
|
||||
{"id": "CLARIDEN-14", "start": "2026-10-06T22:00Z", "end": "2026-10-11T06:00Z", "family": "Displacement", "description": "Slow drift of several targets over four days, made of small steps, then stabilization: D-303-B rises vertically, D-303-C and D-304-C rise vertically, D-301-C rises horizontally, D-306-B goes down horizontally. The camera moves: its tilt drifts slowly over the same days, with a small step on the 8th, and these targets follow it closely in the directions of their curves; the compensation does not absorb this tilt equally on every target. Ordinary recognition error, nothing on the images. The camera housing temperature stays almost constant over these days: no link with it. Slow return from the 11th to the 19th, labeled separately. Deduced from the curves and the camera pose: mostly a remainder of the camera tilt, not established as a movement of the structure; the camera is to be monitored, and these targets checked against the other measurements of the site."}
|
||||
{"id": "CLARIDEN-1", "start": "2026-10-01T00:00Z", "end": "2026-11-01T00:00Z", "family": "Target issue", "description": "The target P-300-B is rejected at every measurement of the batch: its recognition error stays almost at 1, its corrected curve is missing over the whole month. This has lasted since 29 September in the late afternoon, the time when the recognition error of other targets, including its neighbor P-301-B, also changes level all at once: a station setting changed that day. On the thumbnails (the 1st, the 15th and the 31st), the prism spot is sharp and bright, but next to the position where the system looks for it: the target seems badly configured or badly positioned, not hidden. Curve to ignore; correct the position of the target in the configuration or check the prism.", "review": "2026-11-17", "analysis": "CLARIDEN_2026-10-01T0000_2026-11-01T0000"}
|
||||
{"id": "CLARIDEN-14", "start": "2026-10-06T22:00Z", "end": "2026-10-11T06:00Z", "family": "Displacement", "description": "Slow drift of several targets over four days, made of small steps, then stabilization: D-303-B rises vertically, D-303-C and D-304-C rise vertically, D-301-C rises horizontally, D-306-B goes down horizontally. The camera moves: its tilt drifts slowly over the same days, with a small step on the 8th, and these targets follow it closely in the directions of their curves; the compensation does not absorb this tilt equally on every target. Ordinary recognition error, nothing on the images. The camera housing temperature stays almost constant over these days: no link with it. Slow return from the 11th to the 19th, labeled separately. Deduced from the curves and the camera pose: mostly a remainder of the camera tilt, not established as a movement of the structure; the camera is to be monitored, and these targets checked against the other measurements of the site.", "analysis": "CLARIDEN_2026-10-01T0000_2026-11-01T0000"}
|
||||
{"id": "CLARIDEN-72", "start": "2026-10-11T06:00Z", "end": "2026-10-16T12:00Z", "family": "Displacement", "description": "The targets of row C slowly come back after their drift of the 6th to the 11th: D-301-C goes back down horizontally from the 11th to the 15th, D-304-C and D-303-C go back down vertically from the 12th until the first measurements after the gap of the night of the 15th to the 16th, then stay at that level until the 17th: the return is over. Their later movements are not part of it: the dip of the 18th and 19th follows the slow tilting of the camera and comes back at its jump of the 20th (both labeled separately). These movements do not follow the slight straightening of the camera of the 11th to the 13th either, which leaves only a remainder within the noise on the curves: they continue while the camera is still. Nothing in front of the targets on the image of the 13th. The housing temperature stays almost constant over these days: no link with it. This is the return of the drift of the 6th to the 11th, labeled separately. Cause not established, in a tunnel under construction: a movement of these targets is not excluded. To be checked against the other measurements of the site; monitor this row.", "analysis": "CLARIDEN_2026-10-11T0000_2026-10-20T0400"}
|
||||
{"id": "CLARIDEN-50", "start": "2026-10-11T08:50Z", "end": "2026-10-11T09:10Z", "family": "Displacement", "description": "For one measurement, the corrected vertical curves of many targets drop together, then come back at the next one. D-304-A, D-301-A, D-303-A and D-302_A drop the most; D-301-C, D-302-B and PR_BG (same prism), P-299-B, P-301-B and P-299-A drop less. At that measurement, the whole scene shifts slightly in the image and the camera pose jumps (rotation, tilt), but the reference D-302-C does not follow the other references: the compensation is skewed for one measurement. The recognition error does not move. The image of that instant shows nothing in front of the targets. Cause not established; points to ignore, not a movement of the structure.", "analysis": "CLARIDEN_2026-10-11T0000_2026-10-20T0400"}
|
||||
{"id": "CLARIDEN-52", "start": "2026-10-15T22:50Z", "end": "2026-10-16T10:30Z", "family": "No data", "description": "No measurement or image for almost twelve hours, on the night of 15 to 16, and no station metric. The gap starts at the same time, around 23:00, on the nine stations that were measuring then (LENZSPITZE only has its first measurements in the middle of that night, WILDSTRUBEL is already stopped), and their metrics stop at the same time on most of them; measurements and metrics resume at different times depending on the station, most of them in late morning. JUNGFRAU, whose metrics continue, accumulates unsent entries all night, sent in late morning, and yet its measurements for the night are missing from the data: a common cause outside the stations (transmission or reception of the data), not a shutdown of the stations; it is not established. In addition, at CLARIDEN, the station restarts on its battery: the voltage stays well below its usual level, without charge, until early afternoon, then charging resumes; its power supply was also missing that night. The curves are missing over the range; check the site power supply if it repeats.", "analysis": "CLARIDEN_2026-10-11T0000_2026-10-20T0400"}
|
||||
|
||||
Reference in new issue