auto: the long labels requalified as analyses like the others, <STATION>_<start>_<end>/ with request.json (ex long-labels/<STATION>/); their labels carry the analysis; work/ out of git

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
maximeandClaude Opus 5.5 committed 2026-11-18 07:16:59 +01:00
1 parent ddb17c2189
commit 764af7d8ec
132 files changed
+125 -9256

No files matched your search

@@ -0,0 +1,8 @@
# Requalification of the long labels: BREITHORN
Measured with `tools/scripts/ranges.py --columns corr_x,corr_y` (k 5, merge 12h) on each label's range, level = median of the range, noise = own noise (work/ranges_*.txt, work/ranges_all_*.txt).
- **BREITHORN-2**: kept. The drift goes beyond the threshold. POUI19 corr_x stays above its level from 10/10 20:00 to the end of the range (14 measurements), up to +11.1 noises (12/10 12:00, +0.084 px, about +0.3 mm). COLJ19 corr_x goes up to +7.7 noises (11 measurements, 11/10 12:00 → 13/10 04:00). This is a movement of the corr, not missing points.
- **BREITHORN-13**: corrected. The drift goes beyond the threshold: COLH20 corr_x up to +12.6 noises (30/10 04:00, about +0.8 mm), +11.2 noises on 28–29/10; COLJ19 +8.2 noises; POUI19 +7.3 noises; COLI20 +6.5 noises at the end of the range. I applied the correction the period analysts found: COLI22, COLH20''', POUI22 and POUI24 are added to the description. The label loses its review field.
Not checked in this pass (usage limit): the rolling level under the drift (`--rolling`). It is not needed to keep these labels, since the plain level already passes 5 noises.
@@ -0,0 +1,2 @@
{"start": "2026-10-03T00:00Z", "end": "2026-10-13T04:00Z", "family": "Displacement", "description": "From the start of the data to 13 October, six targets drift slowly and steadily, all in the same direction, mostly in corr_x, in corr_y too except POUI19: COLH20, COLI20, COLI21, COLJ19, POUI19 and POUI20; COLI24 drifts in the opposite direction in corr_y. Their drift follows the camera pose step by step, as the camera gradually tilts (tilt increasing, pan and rotation decreasing), while their position in the image hardly moves and their error_value stays stable; the other targets, such as POUH21, do not drift. Cause given by the expert: the camera is gradually nodding forward and the compensation of its movement is not complete, correcting some targets better than others. According to the expert, COLJ19 and POUI19, which drift the most, are much closer to the camera than the other targets; for the other drifting targets, the reason for their poorer compensation (position, angle) is not established. The temperature of the camera housing drops slightly over the range, link not established. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of the three stations tilt together, in the same direction and on the same dates (advance until 12 October, stop and slight backward movement from 13 to 16, resumption from the 17th to the end of the month), which points to a cause common to the building rather than a fault of this camera alone; at equal housing temperature, the cameras are more tilted at the end of the month than in the middle: temperature does not explain it alone, link not established. For the customer: the targets do not move relative to each other, this is not a movement of the structure; the camera tilt is to be monitored.", "review": "2026-11-17"}
{"start": "2026-10-16T20:00Z", "end": "2026-11-01T00:00Z", "family": "Displacement", "description": "From 17 October to the end of the batch, the drift resumes, faster than at the beginning of the month until the 25th, then clearly slower without stopping: the camera tilts again (tilt increasing, pan and rotation decreasing), and COLH20, COLI20, COLI21, COLJ19, POUI19 and POUI20 drift with it, mostly in corr_x and also in corr_y, POUI19 the most; COLI24 drifts in the opposite direction in corr_y. COLI22, COLH20''', POUI22 and POUI24 drift too, more noisily, between their own rejections. Their position in the image hardly moves, their error_value stays stable, POUH21 does not drift. Cause given by the expert: the camera is nodding forward and the compensation of its movement is not complete, correcting some targets better than others. According to the expert, COLJ19 and POUI19, which drift the most, are much closer to the camera than the other targets; for the other drifting targets, the reason for their poorer compensation (position, angle) is not established. The resumption coincides with the drop in the camera housing temperature, but the drift does not come back when it rises: link not established. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of the three stations tilt together, in the same direction and on the same dates (advance until 12 October, stop and slight backward movement from 13 to 16, resumption from the 17th to the end of the month), which points to a cause common to the building rather than a fault of this camera alone; at equal housing temperature, the cameras are more tilted at the end of the month than in the middle: temperature does not explain it alone, link not established. For the customer: the targets do not move relative to each other, this is not a movement of the structure; the camera tilt is to be monitored."}
@@ -0,0 +1,7 @@
# BREITHORN long labels: requalification
2 labels: 1 kept, 1 corrected, 0 removed.
- **BREITHORN-13** (corrected): the drift is real, beyond the noise (COLH20 up to about 0.8 mm, about 13 noises). The description now also names COLI22, COLH20''', POUI22 and POUI24, which drift too, as the period analysts found. The review field was removed.
BREITHORN-2 is kept as it is: POUI19 drifts by about 0.3 mm, about 11 noises.
@@ -0,0 +1,6 @@
{
"station": "BREITHORN",
"start": "2026-10-03T00:00Z",
"end": "2026-11-01T00:00Z",
"hints": "Requalify the long labels of the station (work/existing.jsonl: those that no period analysis owns) under the new rules: keep, correct, remove."
}