auto: the long labels requalified as analyses like the others, <STATION>_<start>_<end>/ with request.json (ex long-labels/<STATION>/); their labels carry the analysis; work/ out of git

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
maximeandClaude Opus 5.5 committed 2026-11-18 07:16:59 +01:00
1 parent ddb17c2189
commit 764af7d8ec
132 files changed
+125 -9256

No files matched your search

@@ -0,0 +1,6 @@
# Requalification of the long labels: CLARIDEN
- **CLARIDEN-1** (Target issue, P-300-B, 01/10 → 01/11): **kept** as is. P-300-B is rejected at 4070 of the 4070 measurement instants present in the range (`inventory.py --start 2026-10-01T00:00Z --end 2026-11-01T00:00Z`; 6371 of 10137 over the whole period, since 29/09). A target rejected almost always: Target issue.
- **CLARIDEN-14** (Displacement, 06/10 22:00 → 11/10 06:00): **corrected** (description). The drift is beyond the threshold: `ranges.py --k 5` from 05/10 10:30 to 15/10 22:50, the level taken outside the label: D-301-C corr_x out of level up to −19.5 noises (−0.22 px, about −1.1 mm) until 08/10 09:20 before it rises to its later level; D-303-B corr_y up to −15.6 noises (about −0.44 mm) until 08/10 08:40; D-304-C corr_x −9.0, D-303-C corr_y −7.1, D-306-B corr_x +6.4 noises. Bounds and family hold. Correction applied (found by the analyst of the 01/10–11/10 period): "No camera movement" is wrong, the camera tilt drifts over these days and D-303-B, D-303-C, D-304-C, D-301-C follow it (hourly r −0.86 to −0.95, `CLARIDEN_2026-10-01T0000_2026-10-11T0000/analysis.md`); the conclusion becomes "camera to monitor". Review removed.
Sources read: `tools/GUIDE.md`, `tools/DATA.md`, `labeling/families.md`, `labeling/labeling-rules.md`, `labeling/reading-rules.md`, `labeling/stations.md`, `input.jsonl`, the analyses of the three CLARIDEN periods (lines on CLARIDEN-1 and CLARIDEN-14). Commands: `inventory.py` (month, `work/inv_month.txt`), `ranges.py` (corr and corr_mm, 5 targets, `--outside` the label).
@@ -0,0 +1,2 @@
{"start": "2026-10-01T00:00Z", "end": "2026-11-01T00:00Z", "family": "Target issue", "description": "The target P-300-B is rejected at every measurement of the batch: its recognition error stays almost at 1, its corrected curve is missing over the whole month. This has lasted since 29 September in the late afternoon, the time when the recognition error of other targets, including its neighbor P-301-B, also changes level all at once: a station setting changed that day. On the thumbnails (the 1st, the 15th and the 31st), the prism spot is sharp and bright, but next to the position where the system looks for it: the target seems badly configured or badly positioned, not hidden. Curve to ignore; correct the position of the target in the configuration or check the prism.", "review": "2026-11-17"}
{"start": "2026-10-06T22:00Z", "end": "2026-10-11T06:00Z", "family": "Displacement", "description": "Slow drift of several targets over four days, made of small steps, then stabilization: D-303-B rises vertically, D-303-C and D-304-C rise vertically, D-301-C rises horizontally, D-306-B goes down horizontally. The camera moves: its tilt drifts slowly over the same days, with a small step on the 8th, and these targets follow it closely in the directions of their curves; the compensation does not absorb this tilt equally on every target. Ordinary recognition error, nothing on the images. The camera housing temperature stays almost constant over these days: no link with it. Slow return from the 11th to the 19th, labeled separately. Deduced from the curves and the camera pose: mostly a remainder of the camera tilt, not established as a movement of the structure; the camera is to be monitored, and these targets checked against the other measurements of the site."}
@@ -0,0 +1,5 @@
# CLARIDEN long labels: requalification
2 labels: 1 kept, 1 corrected, 0 removed.
- **CLARIDEN-14** corrected: the drift does stand out (up to about 20 noises: D-301-C horizontal about 1 mm, D-303-B vertical about 0.4 mm), but its text said "no camera movement". In fact the targets follow the slow tilt of the camera, so the conclusion is now "the camera is to be monitored" rather than "the targets may be moving". The bounds and the family are unchanged.
@@ -0,0 +1,6 @@
{
"station": "CLARIDEN",
"start": "2026-10-01T00:00Z",
"end": "2026-11-01T00:00Z",
"hints": "Requalify the long labels of the station (work/existing.jsonl: those that no period analysis owns) under the new rules: keep, correct, remove."
}