Rules: a movement of the corr is labeled only beyond 5 own noises, the threshold of the thermal cycle; a missing point at any amplitude; under it, the ordinary noise goes in the analysis, not in a label (WYOMING: an agitation under the threshold, removed according to the expert)

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
maximeandClaude Opus 5.5 committed 2026-11-17 15:30:03 +01:00
1 parent 2a5d87659b
commit c779de7720
2 files changed
+4 -4

No files matched your search

+2 -2
View File
@@ -79,7 +79,7 @@ What has been labelled so far, one line each: **name**: what is seen; how to tel
- **A rise over several days with the drop in temperature**: the temperature keeps falling for days and the structure keeps rising; it comes back at equal temperature (else Displacement).
### Displacement
- **A step of the camera that the compensation does not erase**: the camera moves at once and a remainder passes into the curves; a step that leaves nothing is not labelled.
- **A step of the camera that the compensation does not erase**: the camera moves at once and a remainder passes into the curves; a step that leaves nothing beyond the noise is not labelled.
- **The camera tilts little by little**: over weeks, the tilt rises and the compensation corrects some targets better than others; the targets do not move relative to each other.
- **The base changes without a reference lost**: all references kept, the distance between them changes a little; all targets shift together without moving in the image.
- **A real movement of the structure**: targets shift and stay, with references and pose stable and a good image; if the camera and references moved too, the amplitude is not established.
@@ -95,6 +95,6 @@ What has been labelled so far, one line each: **name**: what is seen; how to tel
## What is not labeled
- What touches neither `corr_x` nor `corr_y`: an `error_value` that rises without effect on them; a camera step well compensated, even on two references, as long as the `corr` keep nothing of it (if some remains, the label bounds the step and concludes "the camera moves"). Thermal movement, on the other hand, is always labeled (D-117).
- What does not stand out from the noise of `corr_x` and `corr_y` (the threshold of `labeling-rules.md`, section 1): an `error_value` that rises without effect on them; a camera step well compensated, even on two references, as long as the `corr` keep nothing of it beyond the noise (if some remains, the label bounds the step and concludes "the camera moves"). Thermal movement, on the other hand, is always labeled (D-117).
- The station's intended configuration (targets that are twins of their references: the same prism serves as target and reference; they are named with their reference in its labels).
- The expert can say so with the key `None` (labeling tool: "None (curves untouched)"): such a label is not counted.