auto: labels requalified under the 5-noise rules (only what stands out from the noise): 32 analyses refined, the 6 paused periods verified, the long labels requalified with the fixes the period analysts found; 1153 -> 961 labels
- 32 analyses: each label kept, rewritten or removed by its analyst (section Requalification of the report; mm magnitudes where the targets have them) - SNCF01 x3, WILDSTRUBEL 2026-09-01 -> 2026-10-06 x3: verified from their existing labels under the new rules - long labels (no analysis): auto/analyses/long-labels/<STATION>/; NORDEND-169 and -195 run to 07/11, so NORDEND-283 and -284 (their continuation) are removed - reading-rules.md, stations.md: the citations of removed or rewritten labels point to their successor, or to [expert] Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
c779de7720
commit
ddb17c2189
321 files changed
+18464
-3426
No files matched your search
@@ -1,91 +1,84 @@
|
||||
# Labels: BREITHORN, 2026-10-03T00:00Z → 2026-10-13T00:00Z (UTC)
|
||||
|
||||
Task: verify the 8 existing labels of the range (`work/existing.jsonl`, all reviewed on 2026-11-17) and the spanning label BREITHORN-2. Cadence 4 h (00, 04, 08, 12, 16, 20 UTC), 61 instants, no missing step, a pose at every instant, no image-quality metrics (old camera). No weather: BREITHORN has no place in `~/aimsight-data/extraction/stations.txt` (the line has the name only), so I fetched no MeteoSwiss data. The station is indoors, in a factory (`stations.md`).
|
||||
Task: requalify the 12 labels of this analysis under the new rules (`labeling-rules.md` §1): only what stands out from the noise of the corrected curves is labelled, by more than 5 of the sensor's own noises. Not a new reading: the bounds of the kept labels do not move, and no new event was looked for. The verification analysis before this one is kept in git; its reading (cadence 4 h, 61 instants, old camera without image-quality metrics, vehicles at the bottom of the scene, the camera's cold-morning signature) still holds.
|
||||
|
||||
## Verdict per old id
|
||||
No weather: `data/BREITHORN/weather/` does not exist (no Swiss position for the station). The station is indoors, in a factory (`stations.md`).
|
||||
|
||||
| id | verdict | evidence |
|
||||
|---|---|---|
|
||||
| BREITHORN-1 | kept | REFPOU22, COLH20''' and POUI22 rejected from 03T04 to 04T16 (10 steps, inventory); everything back at 04T20; the vehicle is at the bottom of the 04T08 image; the corr_x of REFH22 goes from about −0.009 to −0.03/−0.046 and comes back at 04T20. Starts at the first measurement of the data (edge). |
|
||||
| BREITHORN-2 (spanning) | correct inside the range | drift of corr_x: COLJ19 0.076 → 0.170, POUI19 0.110 → 0.287, COLI21 −0.001 → 0.081, COLH20 0.029 → 0.070, POUI20 0.036 → 0.077, COLI20 −0.003 → 0.040; COLI24 corr_y −0.033 → −0.138; POUI19 corr_y flat. Tilt 0.0094 → 0.0197, pan and rotation going down, housing temperature 31.5 → 30. Nothing to change. |
|
||||
| BREITHORN-3 | kept | 04T16: every sensor out of level (rolling ranges: REFH22 corr_y +44 noises, refs −24, targets −9 to −26); REFH22 error_value 0.566 (threshold 0.7), POUI24 rejected; back at 04T20. |
|
||||
| BREITHORN-4 | kept | COLI22, COLI24, POUI22 rejected 06T20 → 07T04; nothing else out of level; back at 07T08. |
|
||||
| BREITHORN-5 | kept | 07T12: REFI'21 rejected (error 0.99), 3 references retained; COLJ19, POUI19 corr_y +9 noises, COLI20, COLI22, POUI24 +6 to +8; back at 07T16. |
|
||||
| BREITHORN-6 | kept | COLI24 rejected 07T20–08T00, COLI22 and POUI22 08T00; POUI22 corr_y +0.199 at 07T20 (+18 noises), POUI24 corr_y +0.409 at 08T00 (+59 noises); back at 08T04. |
|
||||
| BREITHORN-7 | kept | REFH22, COLI22, COLI24, POUI22 rejected 09T00 → 09T04; POUI24 corr_x +0.17, corr_y +0.27/+0.35 (+40/+52 noises); back at 09T08. The other targets shift a little (REFG44N, REFI'21 corr_y −0.013, COLI21 −0.033, under 3 noises): "without making the other targets jump" holds at the 5-noise threshold. |
|
||||
| BREITHORN-8 | kept | COLI22, COLI24, POUI22 rejected at 09T20 only; nothing else out of level. |
|
||||
| BREITHORN-9 | kept | 10T04: COLI22, COLI24, POUI22, POUI24 rejected; REFH22 error 0.475, corr_y +70 noises; every other sensor −8 to −27 noises; back at 10T08. |
|
||||
Distances and mm per px (`inventory.py`): COLJ19 8.9 m (3.27 mm/px), POUI19 9.4 m (3.55), COLI20, POUI20, COLH20, COLH20''' 20–23 m (7.6–8.6), COLI21, POUH21 30 m (11.35), COLI22, POUI22 40 m (15.0–15.2), COLI24, POUI24 60 m (22.5–22.8). The four references have no mm factor: their corr are in px only.
|
||||
|
||||
Result: 7 kept as they are, 1 rewritten (BREITHORN-1), 4 removed (BREITHORN-28, -31, -4, -8).
|
||||
|
||||
## 1. My labels
|
||||
|
||||
The 8 kept labels are in `labels.jsonl` unchanged (with their review field). Here are the 4 added ones.
|
||||
### 2026-10-03T00:00Z → 2026-10-04T20:00Z (BREITHORN-1, rewritten)
|
||||
- **Phenomenon of the catalogue**: a reference hidden by an obstacle; the compensation runs on the other references.
|
||||
- **Precedents**: none new. The label was reviewed, and its substance holds.
|
||||
- **Family**: Obstruction. The cause is a parked vehicle in front of the bottom of the scene (images 03–04 Oct).
|
||||
- **Measured**: REFPOU22, COLH20''' and POUI22 are rejected from 03T04 to 04T16. Under the old description, these missing curves were the label. They are no longer labelled for themselves. What remains is the effect on the other curves. `ranges.py --k 5 --outside 2026-10-03T00:00Z/2026-10-04T20:00Z` (3 → 7 Oct) gives:
|
||||
- the corr_x of the reference REFH22 is out of its level at every measurement from 03T04 to 04T12, at −6.3 to −10.9 noises (−0.032 to −0.055 px; level +0.009, noise 0.005), except 04T08 (−0.013 px, under 5);
|
||||
- it is back at 04T20 (+0.004);
|
||||
- no target passes 5 noises in that window, apart from 04T16 (BREITHORN-3).
|
||||
|
||||
### 2026-10-04T00:00Z → 2026-10-04T12:00Z
|
||||
- **Phenomenon of the catalogue**: the camera moves through a thermal effect.
|
||||
- **Precedents**: BREITHORN-14, -21, -24, -17 (reviewed): the same morning signature at this station (rotation and scale deviate at the temperature trough, COLH20 and REFPOU22 up in corr_y, REFG44N/REFI'21 down, back at noon), labelled Thermal displacement on the expert's word. They set the family, the bounds (from the last calm measurement to the noon return) and the wording.
|
||||
- **Family**: Thermal displacement. Not Visibility: the error_value of COLH20 stays at its level and nothing is in front of it. Not Obstruction: the vehicle of BREITHORN-1 hides only COLH20''', POUI22 and REFPOU22.
|
||||
- **Measured**: compared with the previous evening (`scripts/thermal_table.py`, `work/thermal_table.txt`), COLH20 corr_y is +0.049 at 04T04 and +0.046 at 04T08, then +0.011 at 04T12. COLI21 is +0.017 at 08. The rotation is −2.9e-3° and −2.5e-3° (`days.py --bounds`: −6.3 noises, 04T04 → 04T08); the scale is −2.5e-5 and −5.1e-5. The housing temperature goes 32.5 → 30.5 → 29.5 °C, then back to 31. REFPOU22 is rejected (3 references), so the usual reference signature cannot be read.
|
||||
- **Images**: 04T08: the parked vehicle is in the foreground at the bottom of the scene; the spots in the upper part, including COLH20, are clear.
|
||||
- **Confidence**: medium. The rotation and COLH20 match the signature, but with only 3 references and the vehicle present the case is less clean than 5 and 6 Oct.
|
||||
The rolling run (±6 measurements) does not show it. That window spans 48 h and sits mostly inside the 40 h plateau, so it hides the shift. The level measured outside the episode is the right one here (GUIDE, ranges `--outside`).
|
||||
- **Images**: from the verification (04T08: the vehicle at the bottom of the scene, the three spots hidden).
|
||||
- **Confidence**: medium. The shift is clear and lasts the whole parking. But it is on a reference curve, not on a target, and no target passes the threshold. I kept the label because the rule keeps an episode of missing points "that moves the other curves beyond the noise". I rewrote the description to rest on that effect. It loses its review field.
|
||||
|
||||
### 2026-10-05T00:00Z → 2026-10-05T12:00Z
|
||||
- **Phenomenon of the catalogue**: the camera moves through a thermal effect.
|
||||
- **Precedents**: as above; BREITHORN-24 (28 Oct) has the same amplitude and the same two-measurement shape.
|
||||
- **Family**: Thermal displacement. The error_value of the references stays far below threshold (REFG44N 0.09 → 0.125, REFPOU22 0.057 → 0.066), with no rejection and nothing on the images.
|
||||
- **Measured**: compared with the previous evening:
|
||||
- at 05T04 / 05T08, REFPOU22 corr_y is +0.049 / +0.046 (+5.5 noises with a rolling level), COLH20 +0.040 / +0.062, REFG44N −0.027 / −0.012 (−5.3 noises at 04), REFI'21 −0.021 / −0.008;
|
||||
- the scale is −5.3e-5 / −7.7e-5 (−6.5 noises at 08) and the rotation −1.4e-3 / −2.6e-3 (−5.5 noises at 08);
|
||||
- at 05T12 everything is back (+5, +13, +3, +5 ×1e-3);
|
||||
- the housing temperature falls to its daily trough (30.0 / 29.5 °C).
|
||||
### Kept as they are (same bounds, family, description and review field)
|
||||
| id | bounds | family | deviation that keeps it |
|
||||
|---|---|---|---|
|
||||
| BREITHORN-3 | 04T12 → 04T20 | Obstruction | 04T16: every sensor out of level. REFH22 corr_y +44 noises, COLI22 corr_y −26 (−3.5 mm), POUH21 −14.5 (−1.3 mm), the others −8 to −12 (rolling ±6) |
|
||||
| BREITHORN-29 | 05T00 → 05T12 | Thermal displacement | against the night level (evening of 4 Oct): REFPOU22 corr_y +6.2 noises at 05T04, REFG44N −5.4, POUI19 corr_x +5.3, COLH20 corr_y +5.0 (+0.062 px, +0.5 mm) at 05T08; rolling: REFPOU22 +5.5, REFG44N −5.3 |
|
||||
| BREITHORN-30 | 05T20 → 06T12 | Thermal displacement | against the night level (evening of 5 Oct): REFPOU22 corr_y +5.8 noises at 06T08 (rolling 5.0). The targets reach 4.6 at most (POUI24 corr_x) |
|
||||
| BREITHORN-5 | 07T08 → 07T16 | Obstruction | 07T12: COLJ19 corr_y +9.4 noises (+0.38 mm), POUI19 +9.2 (+0.36 mm), COLI22 corr_x +8.4 (+0.9 mm), POUI24 corr_y +7.3 (+1.2 mm), COLI20 +6.5 |
|
||||
| BREITHORN-6 | 07T16 → 08T04 | Obstruction | POUI22 corr_y +18.4 noises at 07T20 (+3.9 mm), POUI24 corr_y +59 at 08T00 (+9.6 mm) |
|
||||
| BREITHORN-7 | 08T20 → 09T08 | Obstruction | POUI24 corr_y +40.5 / +51.6 noises at 09T00 / 09T04 (+6.6 / +8.4 mm), corr_x +14.5 (+2.9 mm) |
|
||||
| BREITHORN-9 | 10T00 → 10T08 | Obstruction | 10T04: REFH22 corr_y +70 noises, POUH21 −14 (−1.3 mm), COLH20''' −14 (−1.0 mm), COLI20 −11.6, the others −8 to −10 |
|
||||
|
||||
The corr_y of COLJ19 and POUI19 rise at 05T08 and keep part of it: that belongs to the drift of BREITHORN-2.
|
||||
- **Images**: 05T08 and 05T16 are identical in content: spots clear, nothing in front.
|
||||
- **Confidence**: high.
|
||||
|
||||
### 2026-10-05T20:00Z → 2026-10-06T12:00Z
|
||||
- **Phenomenon of the catalogue**: the camera moves through a thermal effect.
|
||||
- **Precedents**: as above; BREITHORN-17 and -25 also start at night.
|
||||
- **Family**: Thermal displacement (same reasons).
|
||||
- **Measured**: compared with the previous evening:
|
||||
- at 06T00 / 04 / 08, REFPOU22 corr_y is +0.029 / +0.040 / +0.045 (+5.0 noises at 08), COLH20 +0.040 / +0.035 / +0.045, REFG44N −0.022 / −0.014 / −0.018, REFI'21 −0.019 / −0.011 / −0.014;
|
||||
- the scale is −2.9e-5 / −2.8e-5 / −6.1e-5 (−5.2 noises at 08);
|
||||
- at 06T12 the corr are back (+9, +15, −1, −1); the scale is still −3.1e-5 there and back at 16. That is the slow relaxation of a secondary axis, which does not push the end back;
|
||||
- at 05T20 all is calm (+3, +13, −1, +1);
|
||||
- the housing temperature is 31.5 → 30.0 → 31.0 °C.
|
||||
- **Images**: 06T08: spots clear, a small light at the far left, away from any spot.
|
||||
- **Confidence**: high.
|
||||
|
||||
### 2026-10-11T20:00Z → 2026-10-12T16:00Z
|
||||
- **Phenomenon of the catalogue**: the camera moves through a thermal effect.
|
||||
- **Precedents**: BREITHORN-21, a weaker case accepted in review.
|
||||
- **Family**: Thermal displacement.
|
||||
- **Measured**: compared with the previous evening:
|
||||
- at 12T00 / 04 / 08, REFPOU22 corr_y is +0.021 / +0.025 / +0.025, COLH20 +0.010 / +0.028 / +0.019, REFG44N −0.014 / −0.007 / −0.007;
|
||||
- COLI21 is −0.011 / −0.026 / −0.016 and COLH20''' −0.014 / −0.023 / −0.013;
|
||||
- POUI24 is −5.9 noises at 12T04 (rolling level), and POUI19 −5.2 noises at 12T08 (corr_y −0.172 / −0.179 against about −0.12 to −0.13 before). POUI19 is still −0.146 at 12T12 and back at 12T16 (−0.100), hence the end;
|
||||
- the scale is −2.7 / −3.8 / −3.3 e-5 and the rotation −0.4 / −1.3 / −1.3 e-3;
|
||||
- the housing temperature is 29.5 → 28.75 °C, the lowest of the range, then 30–31.
|
||||
|
||||
The corr of single targets pass 5 noises, so the "no cycle" rule does not apply.
|
||||
- **Images**: 12T04: identical to the calm images, nothing in front.
|
||||
- **Confidence**: medium. The pattern is coherent, but it is the weakest of the four, and only two targets pass 5 noises.
|
||||
BREITHORN-30 is the closest to the threshold. It holds on a reference curve (REFPOU22) against the night level, which is the measure the rule gives for a thermal label. Confidence medium.
|
||||
|
||||
## 2. What I left without a label
|
||||
- **3 Oct, morning**: COLH20 corr_y is higher at 03T08 (about +0.028 against the 03T04/03T12 values) and the scale is −3e-5 (2.7 noises), with the housing temperature at 30.25. There is no previous evening to compare with, REFPOU22 is rejected from 03T04 (the base changes), and nothing passes 5 noises. Not labelled.
|
||||
- **11 Oct, morning**: REFPOU22 +0.013 / +0.018, COLH20 +0.011 / +0.019 at 04/08, scale −3.8e-5 (3.2 noises). No sensor and no pose axis reaches 5 noises: no thermal label (labeling-rules §2/§1, 5-noise rule).
|
||||
- **7 Oct night and 8 Oct**: the scale is low all day and the rotation steps down from 08T08 (−8 noises, no return). That is the progressive tilt of BREITHORN-2 (spanning), not a daily cycle; COLH20/REFPOU22 do not show the morning signature.
|
||||
- **12T16 and 12T20**: the camera pose is exactly the same at both instants, and so is the corr of the four references, while the targets differ a little (within their noise). It looks like a registration reused from the previous measurement. The corr show nothing abnormal, so there is no label; noted as a data oddity.
|
||||
- **The drift itself** (corr_x of COLJ19, POUI19, COLI21…) is BREITHORN-2, out of my scope.
|
||||
|
||||
Removed labels:
|
||||
|
||||
- **BREITHORN-28**, 2026-10-04T00:00Z → 2026-10-04T12:00Z, Thermal displacement. **Under the threshold**. Against the night level (evening of 3 Oct), the largest deviation is 4.1 noises (REFH22 corr_x at 04T08), then COLH20 corr_y 4.0 (+0.049 px, +0.4 mm, 04T04). The rolling run gives nothing over 5 noises in the window. The camera rotation deviated on that cold morning, but the compensation absorbed most of it.
|
||||
- **BREITHORN-31**, 2026-10-11T20:00Z → 2026-10-12T16:00Z, Thermal displacement. **Under the threshold against the night level**. The largest deviation is 4.9 noises (POUI19 corr_y −0.055 px, −0.19 mm, 12T08), then POUI24 corr_y 4.4. REFPOU22 and COLH20 are near 3. The rolling run puts POUI24 at −5.9 (12T04) and POUI19 at −5.2 (12T08). That comes from the later neighbours, not from the night: POUI24 rises afterwards from −0.04 to −0.009 px, which pulls its rolling median up. Against its evening level, POUI24 is −3.8 noises at 12T04. The previous analysis already called it the weakest case.
|
||||
- **BREITHORN-4**, 2026-10-06T16:00Z → 2026-10-07T08:00Z, Obstruction. **Missing points only**. COLI22, COLI24 and POUI22 are rejected at night. No sensor passes 5 noises between 06T16 and 07T08, and the references hold.
|
||||
- **BREITHORN-8**, 2026-10-09T16:00Z → 2026-10-10T00:00Z, Obstruction. **Missing points only**. COLI22, COLI24 and POUI22 are rejected at 09T20. No sensor passes 5 noises there.
|
||||
|
||||
Unchanged from the verification, still not labelled: the morning of 3 Oct and the morning of 11 Oct (thermal signature under 5 noises), and the identical camera pose at 12T16 and 12T20. The slow drift of corr_x is BREITHORN-2, a spanning label outside this batch.
|
||||
|
||||
## 3. The documentation
|
||||
- The cases that decided it were the reviewed BREITHORN thermal labels (14, 17, 21, 24, 25, 27) and NEBRASKA-10. Together they give a very specific signature for this indoor station: rotation and scale deviate at the housing-temperature trough, COLH20 and REFPOU22 rise in corr_y, REFG44N and REFI'21 go down, everything is back at noon. Searching for it over the whole range (labeling-rules §1, "a signature found once is searched over the whole batch") found 4 occurrences that the existing labels of the range missed. The previous analysts of this range seem to have looked only at rejections.
|
||||
- The 5-noise rule ("no thermal label on a day when neither the pose nor the corr deviate by more than 5 noises") sits uneasily with this precedent. On a 4 h cadence the noise is the step between consecutive measurements, and those steps already include the cycle. Several reviewed labels (BREITHORN-21: REFPOU22 about 3.5 noises) fall below it. I applied the rule per sensor and per pose axis: 11 Oct was left out, 12 Oct kept because POUI19 and POUI24 pass it. A note in `labeling-rules.md` on how to measure the noise at a slow cadence would help.
|
||||
- `days.py --bounds` on the median of the targets did not show these cycles, because the targets move in opposite directions and cancel. The per-sensor table of my script and `ranges.py --rolling 6 --instants 2` showed them.
|
||||
- No weather for BREITHORN (no place in `stations.txt`); for an indoor station it matters little.
|
||||
- `labeling-rules.md` §1 sets the measure: ranges at k 5, rolling under a drift or a thermal cycle, the night level for a thermal label. On a 4 h cadence the two measures can disagree. The rolling window (±6 measurements, ±24 h) mixes days and later drifts. Against the night level, BREITHORN-31 falls to 4.9 but BREITHORN-30 rises to 5.8. For the thermal labels I used the night level, as the rule says.
|
||||
- The rolling level hides a plateau longer than its window (BREITHORN-1). `--outside` around the episode shows it. The GUIDE says so, and it decided this case.
|
||||
- The rule says "at least one target". It does not say whether the corr of a reference counts. The tools treat the references like the targets, and the reviewed BREITHORN thermal labels rest on REFPOU22. I counted them. Two labels hold only on a reference curve (BREITHORN-1 on REFH22, BREITHORN-30 on REFPOU22). If the expert counts only the targets, these two would be removed. A sentence in §1 would settle it.
|
||||
|
||||
## Requalification
|
||||
|
||||
Commands (from the repository root, output in `work/`):
|
||||
- `python3 tools/scripts/ranges.py data/BREITHORN --columns corr_x,corr_y --k 5 --rolling 6 --start 2026-10-03T00:00Z --end 2026-10-13T00:00Z` → `work/requalify_ranges_roll6.txt`; the same on `corr_x_mm,corr_y_mm` → `work/requalify_ranges_roll6_mm.txt`.
|
||||
- `python3 tools/scripts/ranges.py data/BREITHORN --columns corr_x,corr_y --k 5 --outside 2026-10-03T00:00Z/2026-10-04T20:00Z --start 2026-10-03T00:00Z --end 2026-10-07T00:00Z` → `work/requalify_ranges_B1_outside.txt`.
|
||||
- `python3 scripts/requalify_thermal.py data/BREITHORN work/requalify_ranges_roll6.txt work/requalify_input.jsonl` → `work/requalify_thermal.txt`. For each thermal label and each sensor, it gives the largest deviation from the median of the previous evening (12, 16, 20 UTC), in the sensor's noise from ranges.py.
|
||||
- `summary.py --column corr_x|corr_y --step 4h` on 2–5 Oct (REFH22) and 11–13 Oct (POUI24, POUI19).
|
||||
|
||||
| id | family | verdict | max deviation (noises) |
|
||||
|---|---|---|---|
|
||||
| BREITHORN-1 | Obstruction | rewritten | REFH22 corr_x −10.9 (outside level), 9 measurements over 5 |
|
||||
| BREITHORN-28 | Thermal displacement | removed | 4.1 (night level) |
|
||||
| BREITHORN-3 | Obstruction | kept | REFH22 corr_y +44, COLI22 −26 |
|
||||
| BREITHORN-29 | Thermal displacement | kept | REFPOU22 corr_y +6.2 (night level) |
|
||||
| BREITHORN-30 | Thermal displacement | kept | REFPOU22 corr_y +5.8 (night level) |
|
||||
| BREITHORN-4 | Obstruction | removed | missing points only, nothing over 5 |
|
||||
| BREITHORN-5 | Obstruction | kept | COLJ19 corr_y +9.4 |
|
||||
| BREITHORN-6 | Obstruction | kept | POUI24 corr_y +59 |
|
||||
| BREITHORN-7 | Obstruction | kept | POUI24 corr_y +51.6 |
|
||||
| BREITHORN-8 | Obstruction | removed | missing points only, nothing over 5 |
|
||||
| BREITHORN-9 | Obstruction | kept | REFH22 corr_y +70 |
|
||||
| BREITHORN-31 | Thermal displacement | removed | 4.9 (night level); rolling 5.9 from the neighbours |
|
||||
|
||||
`validate.py`: 0 errors. One overlap remains (BREITHORN-1 and BREITHORN-3). It was already there, it was reviewed, and the bounds are not to be moved.
|
||||
|
||||
## Difficulties
|
||||
- My first run of `thermal_table.py` matched no instants: the measurement times carry seconds (`00:00:03.37`), while the pose and temperature are on the minute. I fixed it by rounding to the minute.
|
||||
- `validate.py` flags the overlap of BREITHORN-1 and BREITHORN-3 (two Obstruction labels). It was already there and was reviewed by the user, so I kept it as it is.
|
||||
- The data now start on 1 Sep (pumped since). BREITHORN-1 starts at 03T00 as the batch edge. REFH22 corr_x already drops a little between 02T20 and 03T00, but the bounds of a kept label are not to be moved.
|
||||
|
||||
## Sources read
|
||||
`instructions/analyst.md`, `tools/GUIDE.md`, `tools/DATA.md`, `labeling/families.md`, `labeling/labeling-rules.md`, `labeling/reading-rules.md`, `labeling/stations.md`, `labeling/auto/BREITHORN.jsonl` (ids, and the texts of 10, 11, 14, 17, 21, 24), `work/existing.jsonl`, `work/spanning.jsonl`, the precedents (`precedents.py`, thermal morning query). Data: `inventory.py`, `summary.py` (corr_x, corr_y, error_value at 4 h, `--mark`), `metrics.py` (4 h, 2 → 14 Oct), `days.py --night 12-23 --bounds`, `ranges.py --rolling 6 --instants 2`, `plot.py`, `scripts/thermal_table.py` (my own, 3 → 30 Oct), images 04T08, 05T08, 05T16, 06T08, 12T04. `tools/scripts/data.py` was read for its loader API only.
|
||||
`instructions/analyst.md`, `labeling/labeling-rules.md` (§1–3), `labeling/families.md` (via grep), `tools/GUIDE.md` (ranges, conventions), `tools/DATA.md` (columns), the previous `analysis.md`, `report.md`, `work/requalify_input.jsonl`, `work/ranges_roll.txt`, `scripts/thermal_table.py`. Data: `inventory.py`, `ranges.py` (above), `summary.py`, `scripts/requalify_thermal.py`.
|
||||
@@ -1,12 +1,8 @@
|
||||
{"start": "2026-10-03T00:00Z", "end": "2026-10-04T20:00Z", "family": "Obstruction", "description": "The curves of COLH20''' and POUI22 are missing from the morning of 3 October to the late afternoon of 4 October: their measurements are rejected, like those of the reference REFPOU22. On the thumbnails and the images of those hours, the three spots have disappeared behind an object with light reflections in vertical bands, a vehicle parked in front of them; they come back at the evening measurement of the 4th, without any offset. The compensation then runs on three references; the other targets do not jump, only the corr_x of the reference REFH22 shifts a little. The structure does not move: ignore COLH20''' and POUI22 over the range.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-04T00:00Z", "end": "2026-10-04T12:00Z", "family": "Thermal displacement", "description": "On 4 October in the morning, over two measurements, the camera rotation deviates clearly and its scale a little, then both come back at noon; at the same time COLH20 rises clearly in corr_y, COLI21 a little, then they return at noon. The movement falls at the trough of the camera housing temperature, read in the metrics, and comes back when it rises, with the same signature as the reviewed cold mornings of later in October; the error_value of COLH20 does not move, that of the reference REFG44N rises only a little. The compensation runs on three references that morning, REFPOU22 being hidden by the vehicle parked in front of the bottom of the scene since the day before (labelled apart); on the 08:00 image that vehicle is at the bottom of the scene, nothing is in front of COLH20. Thermal effect on the camera, incompletely compensated, according to the expert it is the housing temperature that matters: nothing to fear for the structure, nothing to do; do not trust these two points of COLH20."}
|
||||
{"start": "2026-10-03T00:00Z", "end": "2026-10-04T20:00Z", "family": "Obstruction", "description": "From the morning of 3 October to the late afternoon of 4 October, the reference REFPOU22 is rejected together with the targets COLH20''' and POUI22: on the thumbnails and the images of those hours, the three spots are hidden behind an object with light reflections in vertical bands, a vehicle parked in front of the bottom of the scene. With one reference fewer, the compensation runs on the three others, and the corr_x of the reference REFH22 shifts clearly beyond its noise as soon as REFPOU22 is lost, stays shifted for the whole parking, then comes back to its level at the evening measurement of the 4th, when the three spots return without offset. The other targets keep their level within the noise. A change of the compensation basis caused by the hidden reference, not a movement: the structure does not move, nothing to do."}
|
||||
{"start": "2026-10-04T12:00Z", "end": "2026-10-04T20:00Z", "family": "Obstruction", "description": "For the duration of one measurement, on 4 October in the late afternoon, all the targets jump together in corr_x and in corr_y, then return at the next measurement. At that measurement, POUI24 is rejected in turn (curve absent), COLI22 jumps clearly in corr_y, and the reference REFH22, half hidden, rises clearly in error_value without being discarded, which distorts the basis of all the targets; COLH20''', POUI22 and REFPOU22 remain hidden by the vehicle parked since the day before. On the image of that hour, the banded reflections have disappeared and a light shines under POUI22: the obstacle has changed position in front of the bottom of the scene. The jumps are not a movement: point to ignore, nothing to do.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-05T00:00Z", "end": "2026-10-05T12:00Z", "family": "Thermal displacement", "description": "On 5 October in the morning, over two measurements, the camera scale and rotation deviate, then return at noon; at the same time the reference REFPOU22 and COLH20 rise clearly in corr_y while the references REFG44N and REFI'21 go down, then everything returns at noon. The images of 08:00 and 16:00 are alike, nothing obstructs the view; the error_value change little (the reference REFG44N rises a little, far from its threshold). This falls at the trough of the camera housing temperature, read in the metrics, and comes back when it rises: the same signature as the reviewed cold mornings of later in October. Thermal effect on the camera, incompletely compensated, according to the expert it is the housing temperature that matters, not the air temperature. Nothing to fear for the structure, nothing to do; do not trust these points."}
|
||||
{"start": "2026-10-05T20:00Z", "end": "2026-10-06T12:00Z", "family": "Thermal displacement", "description": "From midnight to the morning of 6 October, over three measurements, the camera scale and rotation deviate, most at 08:00, then return at noon; the reference REFPOU22 and COLH20 rise clearly in corr_y, the references REFG44N and REFI'21 go down a little, then everything returns at noon. Nothing obstructs the targets on the 08:00 image (only a small light at the far left of the scene, away from the spots); the error_value change little. This falls when the camera housing temperature drops, read in the metrics, and comes back when it rises: the same signature as the reviewed cold mornings of later in October. Thermal effect on the camera, incompletely compensated, according to the expert it is the housing temperature that matters. Nothing to fear for the structure, nothing to do; do not trust these points."}
|
||||
{"start": "2026-10-06T16:00Z", "end": "2026-10-07T08:00Z", "family": "Obstruction", "description": "On the night of 6 to 7 October, the curves of COLI22, COLI24 and POUI22 are missing: their measurements are rejected, the spots are no longer visible on the thumbnails. On the 20:00 UTC image, the cab of a parked vehicle is visible right in front of these targets, at the bottom of the scene. The references hold, the other targets do not move; everything comes back in the morning. The structure does not move: ignore these three targets over the range.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-07T08:00Z", "end": "2026-10-07T16:00Z", "family": "Obstruction", "description": "For the duration of one measurement, on 7 October at noon, the reference REFI'21 is rejected: on the image, a vehicle with reflective strips passes on the left of the scene and hides the group of REFI'21. The compensation runs on three references, the basis changes: several targets (POUI19, COLJ19, COLI20, COLI22, COLI24, POUI24) jump a little, mostly in corr_y, then return at the next measurement. This is not a movement: point to ignore.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-07T16:00Z", "end": "2026-10-08T04:00Z", "family": "Obstruction", "description": "On the night of 7 to 8 October, COLI24 is rejected from the evening, then COLI22 and POUI22 too around midnight (curves absent); POUI22 jumps in the evening and POUI24, half hidden, jumps clearly in corr_y around midnight. On the thumbnails, these spots are hidden or reduced, and a vehicle is visible in front of the bottom of the scene. Everything comes back in the morning. The structure does not move: ignore these targets over the range.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-08T20:00Z", "end": "2026-10-09T08:00Z", "family": "Obstruction", "description": "On the night of 8 to 9 October, the curves of COLI22, COLI24 and POUI22 are missing (measurements rejected) and the reference REFH22 is rejected too; POUI24, half hidden, jumps in corr_x and in corr_y. On the thumbnails, these spots are hidden and a parked vehicle is visible in front of the bottom of the scene, the image veiled by its light. The compensation runs on three references without making the other targets jump. Everything comes back in the morning: ignore these targets over the range, the structure does not move.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-09T16:00Z", "end": "2026-10-10T00:00Z", "family": "Obstruction", "description": "On the evening of 9 October, for the duration of one measurement, the curves of COLI22, COLI24 and POUI22 are missing (measurements rejected); on the thumbnails, their spots are hidden, a vehicle is in front of the bottom of the scene. The other targets and the references do not move. Point to ignore, nothing to do.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-10T00:00Z", "end": "2026-10-10T08:00Z", "family": "Obstruction", "description": "For the duration of one measurement, on 10 October in the morning, all the targets jump together, mostly in corr_y, then return at the next measurement; COLI22, COLI24, POUI22 and POUI24 are rejected (curves absent). On the image of that hour, a vehicle is in front of the bottom of the scene, these spots are hidden and the whole image is veiled by its light; the reference REFH22, hampered, rises clearly in error_value without being discarded, which distorts the basis of all the targets. This is not a movement: point to ignore.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-11T20:00Z", "end": "2026-10-12T16:00Z", "family": "Thermal displacement", "description": "From midnight to the morning of 12 October, over three measurements, the camera scale deviates a little and its rotation weakly, then they return in the afternoon; the reference REFPOU22 and COLH20 rise in corr_y, the references REFG44N and REFI'21 go down weakly, POUI19, POUI24, COLI21 and COLH20''' go down in corr_y, POUI19 the most, then the curves return, POUI19 last, in the afternoon. Nothing obstructs the view on the 04:00 image; the error_value change little. This falls at the lowest housing temperature of the range, read in the metrics, and comes back when it rises: the same signature as the reviewed cold mornings of later in October, weaker. Thermal effect on the camera, incompletely compensated, according to the expert it is the housing temperature that matters. Nothing to fear for the structure, nothing to do; do not trust these points."}
|
||||
@@ -1,31 +1,29 @@
|
||||
# BREITHORN: check of the labels of 3–13 October
|
||||
# BREITHORN: requalification of the labels of 3–13 October
|
||||
|
||||
The question: are the 8 existing labels of 3–13 October right, and what do they miss?
|
||||
|
||||
## Verification
|
||||
|
||||
Kept: 8. Corrected: 0. Removed: 0. Added: 4.
|
||||
|
||||
- BREITHORN-1, -3, -4, -5, -6, -7, -8, -9: kept as they are. Their dates, the targets they name and their causes (vehicles parked or passing at the bottom of the scene) match the curves and the images.
|
||||
- Added, 4 Oct 00:00 → 12:00: a thermal camera movement on a cold morning. It falls inside BREITHORN-1 and was not labelled.
|
||||
- Added, 5 Oct 00:00 → 12:00: a thermal camera movement on a cold morning.
|
||||
- Added, 5 Oct 20:00 → 6 Oct 12:00: a thermal camera movement during a cold night and morning.
|
||||
- Added, 11 Oct 20:00 → 12 Oct 16:00: a thermal camera movement on a cold night and morning, weaker than the others.
|
||||
- Spanning label BREITHORN-2 (the slow drift from the camera tilting): correct within this range. Nothing to change.
|
||||
The question: which labels of 3–13 October still hold now that only what stands out from the noise of the corrected curves is labelled?
|
||||
|
||||
## In short
|
||||
|
||||
The 8 obstruction labels are right. They miss four cold mornings, where the camera moved with its temperature and the curves shifted for a few measurements. No real movement of the structure is seen. The slow drift of some targets over the range is the camera tilting, already labelled.
|
||||
8 labels remain out of 12. They are the vehicles that make the curves jump, the long parking that moves one reference, and two cold mornings. Outside these labels, the curves can be trusted. No real movement of the structure is seen.
|
||||
|
||||
## What happened
|
||||
|
||||
**Vehicles at the bottom of the scene** (3–4, 6–10 October): already labelled and confirmed. COLI22, COLI24, POUI22 and POUI24, and sometimes the references REFPOU22 or REFH22, are hidden. A few single measurements make all targets jump together. Each time they come back. Confirmed on the images.
|
||||
**Vehicles at the bottom of the scene** (4, 7, 8–9 and 10 October). A vehicle parked or passing in front of the lower targets hides some of them. When it hides a reference, or half-hides a target, the curves jump for one or two measurements:
|
||||
- On 4 Oct at 16:00 and on 10 Oct at 04:00, all the targets jump together, by up to about 3.5 mm on COLI22 (40 m away) and about 1.3 mm on the others. A half-hidden reference distorts the correction.
|
||||
- On 7 Oct at noon, a passing vehicle hides the reference REFI'21. The targets shift by 0.4 to 1.2 mm.
|
||||
- On the nights of 7–8 and 8–9 Oct, the half-hidden POUI24 (60 m) jumps by 7 to 10 mm in the corrected curve in y, and POUI22 by about 4 mm.
|
||||
|
||||
**Cold mornings** (4, 5, 6 and 12 October, about midnight to noon): the camera housing cools by one to three degrees. The camera turns and changes scale very slightly, and the correction does not remove it fully. The corrected curve in y of COLH20 and of the reference REFPOU22 goes up, and those of the references REFG44N and REFI'21 go down. On 12 October, POUI19 and POUI24 also go down. Everything comes back by noon or early afternoon, when the housing warms again. The images show nothing in front of the targets. The same pattern was already labelled as thermal on later days of October (19, 21, 26, 28 and 29 Oct). Cause: likely thermal (same signature as the expert's cases); 4 and 12 October less sure.
|
||||
Each time, everything comes back at the next measurement. Cause confirmed on the images.
|
||||
|
||||

|
||||
**The long parking of 3–4 October**. A vehicle hides the reference REFPOU22 and two targets for about 40 hours. The correction then uses three references instead of four. The corrected curve in x of the reference REFH22 stays shifted the whole time, by up to about 11 times its noise (0.05 px; references have no mm). The targets themselves stay within their noise. Cause confirmed.
|
||||
|
||||
In each grey band, COLH20 (orange) and REFPOU22 (blue) go up and REFG44N and REFI'21 (green, red) dip, then all come back. The two deep single drops (4 Oct evening, 10 Oct morning) are vehicles, labelled apart.
|
||||
**Cold mornings** (5 and 6 October). The camera housing cools by one to two degrees. The camera turns and changes scale very slightly, and the correction does not remove all of it. In the corrected curve in y, the reference REFPOU22 rises and REFG44N drops, by about 6 times their noise. COLH20 rises by about 0.5 mm. Everything is back by noon. Likely thermal: it is the same pattern as the expert's later cases at this station. These two mornings are only just over the threshold.
|
||||
|
||||

|
||||
|
||||
Look at 5 and 6 Oct: COLH20 (orange) and REFPOU22 (blue) rise while REFG44N and REFI'21 (green, red) dip. On 4 and 12 Oct the same pattern stays within the noise, so those two are no longer labelled.
|
||||
|
||||
No weather is available for this station. It is indoors.
|
||||
|
||||
## What to do
|
||||
|
||||
@@ -33,22 +31,27 @@ Nothing.
|
||||
|
||||
## Not established
|
||||
|
||||
- 11 October morning shows the same pattern, but too weak to label. 3 October cannot be judged: it is the first day of data, and a reference was hidden.
|
||||
- At 12 October 20:00, the camera position is exactly the same as at 16:00. The camera may have reused the previous registration. It has no visible effect on the curves.
|
||||
- The rule asks for "a target" more than 5 times its noise. Two labels hold only on a reference curve: the parking of 3–4 Oct (REFH22) and the morning of 6 Oct (REFPOU22). If only true targets count, these two would go too. The expert should say which.
|
||||
|
||||
## Requalification
|
||||
|
||||
Kept: 7. Rewritten: 1. Removed: 4.
|
||||
|
||||
- BREITHORN-1 (3 Oct 00:00 → 4 Oct 20:00, Obstruction): rewritten. The missing curves are no longer labelled for themselves. The label now rests on the shift of the reference REFH22 in x, up to 10.9 noises, at 9 measurements over 5 noises.
|
||||
- BREITHORN-28 (4 Oct 00:00 → 12:00, Thermal displacement): removed, at 4.1 noises at most against the night level.
|
||||
- BREITHORN-4 (6 Oct 16:00 → 7 Oct 08:00, Obstruction): removed. Only missing points; no curve passes 5 noises.
|
||||
- BREITHORN-8 (9 Oct 16:00 → 10 Oct 00:00, Obstruction): removed. Only missing points; no curve passes 5 noises.
|
||||
- BREITHORN-31 (11 Oct 20:00 → 12 Oct 16:00, Thermal displacement): removed, at 4.9 noises at most against the night level (POUI19).
|
||||
|
||||
## Labels
|
||||
|
||||
| Start (UTC) | End (UTC) | Family | Targets | In a few words |
|
||||
|---|---|---|---|---|
|
||||
| 03.10 00:00 | 04.10 20:00 | Obstruction | COLH20''', POUI22, REFPOU22 | parked vehicle hides them (kept) |
|
||||
| 04.10 00:00 | 04.10 12:00 | Thermal displacement | COLH20, COLI21 | cold morning, camera turns (added) |
|
||||
| 04.10 12:00 | 04.10 20:00 | Obstruction | all, POUI24 rejected, REFH22 | the vehicle moves, everything jumps once (kept) |
|
||||
| 05.10 00:00 | 05.10 12:00 | Thermal displacement | COLH20, REFPOU22, REFG44N, REFI'21 | cold morning (added) |
|
||||
| 05.10 20:00 | 06.10 12:00 | Thermal displacement | COLH20, REFPOU22, REFG44N, REFI'21 | cold night and morning (added) |
|
||||
| 06.10 16:00 | 07.10 08:00 | Obstruction | COLI22, COLI24, POUI22 | parked vehicle at night (kept) |
|
||||
| 07.10 08:00 | 07.10 16:00 | Obstruction | REFI'21, several targets | passing vehicle hides a reference (kept) |
|
||||
| 07.10 16:00 | 08.10 04:00 | Obstruction | COLI22, COLI24, POUI22, POUI24 | parked vehicle at night (kept) |
|
||||
| 08.10 20:00 | 09.10 08:00 | Obstruction | COLI22, COLI24, POUI22, POUI24, REFH22 | parked vehicle at night (kept) |
|
||||
| 09.10 16:00 | 10.10 00:00 | Obstruction | COLI22, COLI24, POUI22 | vehicle, one measurement (kept) |
|
||||
| 10.10 00:00 | 10.10 08:00 | Obstruction | all, REFH22 | vehicle light, everything jumps once (kept) |
|
||||
| 11.10 20:00 | 12.10 16:00 | Thermal displacement | COLH20, REFPOU22, POUI19, POUI24 | cold night and morning, weak (added) |
|
||||
| 03.10 00:00 | 04.10 20:00 | Obstruction | REFH22 (REFPOU22, COLH20''', POUI22 hidden) | parked vehicle hides a reference, REFH22 shifted |
|
||||
| 04.10 12:00 | 04.10 20:00 | Obstruction | all | the vehicle moves, everything jumps once |
|
||||
| 05.10 00:00 | 05.10 12:00 | Thermal displacement | REFPOU22, REFG44N, COLH20 | cold morning, camera turns |
|
||||
| 05.10 20:00 | 06.10 12:00 | Thermal displacement | REFPOU22 | cold night and morning, at the threshold |
|
||||
| 07.10 08:00 | 07.10 16:00 | Obstruction | COLJ19, POUI19, COLI22, POUI24, COLI20 | passing vehicle hides REFI'21, targets jump |
|
||||
| 07.10 16:00 | 08.10 04:00 | Obstruction | POUI22, POUI24 | parked vehicle, half-hidden targets jump |
|
||||
| 08.10 20:00 | 09.10 08:00 | Obstruction | POUI24 | parked vehicle, POUI24 jumps |
|
||||
| 10.10 00:00 | 10.10 08:00 | Obstruction | all, REFH22 | vehicle light, everything jumps once |
|
||||
@@ -0,0 +1,42 @@
|
||||
"""Requalification of the thermal labels: per label and per sensor, the largest deviation of corr_x / corr_y from the
|
||||
night level (median of the evening measurements 12, 16, 20 UTC of the day before the label's first morning), in the
|
||||
sensor's own noise as printed by ranges.py (file given). Usage: requalify_thermal.py FOLDER RANGES_TXT LABELS_JSONL"""
|
||||
import sys, json, re, statistics
|
||||
from datetime import timedelta
|
||||
sys.path.insert(0, "tools/scripts")
|
||||
import data
|
||||
|
||||
folder, rtxt, lab = sys.argv[1:4]
|
||||
noise, col = {}, None
|
||||
for line in open(rtxt):
|
||||
m = re.match(r"== (corr_[xy]): level", line)
|
||||
if m: col = m.group(1); continue
|
||||
if line.startswith("corr_"): col = None
|
||||
p = line.split()
|
||||
if col and len(p) >= 4 and p[0] != "sensor":
|
||||
try: noise[(p[0], col)] = float(p[3])
|
||||
except ValueError: pass
|
||||
meas = data.load(folder)
|
||||
ser = {s: {m["t"].replace(second=0, microsecond=0): m for m in v} for s, v in meas.items()}
|
||||
for l in map(json.loads, open(lab)):
|
||||
if l["family"] != "Thermal displacement": continue
|
||||
a, b = data.parse_time(l["start"]), data.parse_time(l["end"])
|
||||
morning = b.replace(hour=0, minute=0)
|
||||
d0 = morning - timedelta(days=1)
|
||||
ev = [d0 + timedelta(hours=h) for h in (12, 16, 20)]
|
||||
print(f"\n{l.get('id','')} {l['start']} -> {l['end']} (night level: evening of {data.iso(d0)[:10]})")
|
||||
rows = []
|
||||
for s, sv in ser.items():
|
||||
for c in ("corr_x", "corr_y"):
|
||||
n = noise.get((s, c))
|
||||
base = [sv[t][c] for t in ev if t in sv and sv[t][c] is not None]
|
||||
if not n or not base: continue
|
||||
lvl = statistics.median(base)
|
||||
best = None
|
||||
for t, m in sv.items():
|
||||
if a < t < b and m[c] is not None:
|
||||
d = (m[c] - lvl) / n
|
||||
if best is None or abs(d) > abs(best[0]): best = (d, t, m[c] - lvl)
|
||||
if best: rows.append((abs(best[0]), s, c, best))
|
||||
for _, s, c, (d, t, v) in sorted(rows, reverse=True)[:6]:
|
||||
print(f" {s:10} {c} {d:+5.1f} noises ({v:+.4f} px) at {data.iso(t)}")
|
||||
Reference in new issue
Block a user