auto: labels requalified under the 5-noise rules (only what stands out from the noise): 32 analyses refined, the 6 paused periods verified, the long labels requalified with the fixes the period analysts found; 1153 -> 961 labels
- 32 analyses: each label kept, rewritten or removed by its analyst (section Requalification of the report; mm magnitudes where the targets have them) - SNCF01 x3, WILDSTRUBEL 2026-09-01 -> 2026-10-06 x3: verified from their existing labels under the new rules - long labels (no analysis): auto/analyses/long-labels/<STATION>/; NORDEND-169 and -195 run to 07/11, so NORDEND-283 and -284 (their continuation) are removed - reading-rules.md, stations.md: the citations of removed or rewritten labels point to their successor, or to [expert] Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
c779de7720
commit
ddb17c2189
321 files changed
+18464
-3426
No files matched your search
@@ -4,6 +4,8 @@ The task was to verify the 8 existing labels of the range (`work/existing.jsonl`
|
||||
|
||||
**Weather**: none. There is no `data/CLARIDEN/weather/` folder and no CLARIDEN line in `~/aimsight-data/extraction/stations.txt`: the station has no Swiss position. In any case it is in a tunnel.
|
||||
|
||||
|
||||
**Requalification of 2026-11-17** (new rule, `labeling-rules.md` §1: only what stands out from the noise of the corrected curves, at least one target beyond 5 of its own noises). The work below is the verification already done; the ids are now the current ones (old id → current: 15 → 49, 16 → 52, 17 → 17, 18 → 55, 19 → 56, 20 → 57, 21 → 58, 22 → 59; the added labels became 50, 51, 53, 54). Result: 10 kept as they are, 1 rewritten (CLARIDEN-49), 1 removed (CLARIDEN-51). The values are in section 2 and in "## Requalification".
|
||||
## Verdict per old id
|
||||
|
||||
| id | verdict | evidence |
|
||||
@@ -23,7 +25,7 @@ The task was to verify the 8 existing labels of the range (`work/existing.jsonl`
|
||||
|
||||
## 1. My labels
|
||||
|
||||
### 2026-10-11T06:00Z → 2026-10-16T12:00Z (CLARIDEN-15, corrected)
|
||||
### 2026-10-11T06:00Z → 2026-10-16T12:00Z (CLARIDEN-49, ex-15; rewritten at the requalification)
|
||||
- **Phenomenon of the catalogue**: Targets move slowly, alone, then come back (return part).
|
||||
- **Precedents**: CLARIDEN-14 (its outward), reviewed.
|
||||
- **Family**: Displacement. No cause is established, and the movement does not follow the temperature (housing at 40.0–40.4 °C).
|
||||
@@ -31,14 +33,14 @@ The task was to verify the 8 existing labels of the range (`work/existing.jsonl`
|
||||
- **Images**: 13th 12:00, a whole-zone thumbnail: nothing in front of the targets.
|
||||
- **Confidence**: medium. The end is read on medians of about 0.01 px steps, close to the noise (MAD 0.011 per measurement).
|
||||
|
||||
### 2026-10-15T22:50Z → 2026-10-16T10:30Z (CLARIDEN-16, corrected start)
|
||||
### 2026-10-15T22:50Z → 2026-10-16T10:30Z (CLARIDEN-52, ex-16)
|
||||
- **Phenomenon**: A gap common to several stations, plus a station restart on its battery (as described).
|
||||
- **Family**: No data. **Measured**: 69 missing steps; no metrics 00:00–09:00; BusVoltage 13.3 V at the restart, then 14.36 V. **Images**: none from 22:00 to 10:30. **Confidence**: high.
|
||||
|
||||
### 2026-10-16T14:20Z → 2026-10-16T14:40Z (CLARIDEN-17, kept)
|
||||
### 2026-10-16T14:20Z → 2026-10-16T14:40Z (CLARIDEN-17)
|
||||
No data, one step; high confidence.
|
||||
|
||||
### 2026-10-18T08:50Z → 2026-10-18T09:30Z (CLARIDEN-18, corrected)
|
||||
### 2026-10-18T08:50Z → 2026-10-18T09:30Z (CLARIDEN-55, ex-18)
|
||||
- **Phenomenon**: Visibility drops over the whole scene, without an obstacle (by its signature); like CLARIDEN-12.
|
||||
- **Precedents**: CLARIDEN-12 (reviewed Visibility, same group D-301-C, D-302-B/PR_BG, D-304-B).
|
||||
- **Family**: Visibility rather than Displacement. The error_value rises on most sensors, including references, with sharp edges (families.md boundary "Thermal or Visibility"). The pose jump comes with it.
|
||||
@@ -46,13 +48,13 @@ No data, one step; high confidence.
|
||||
- **Images**: 08:00 and 09:00, whole image: identical, nothing in front.
|
||||
- **Confidence**: medium. The bounds are sure; the cause is deduced, not seen.
|
||||
|
||||
### 2026-10-18T13:50Z → 2026-10-18T23:30Z (CLARIDEN-19, corrected start)
|
||||
### 2026-10-18T13:50Z → 2026-10-18T23:30Z (CLARIDEN-56, ex-19)
|
||||
No data; signature of a power cut (low voltage at the restart). High confidence.
|
||||
|
||||
### 2026-10-19T09:00Z → 2026-10-19T10:10Z (CLARIDEN-20) and 2026-10-19T20:40Z → 2026-10-19T21:30Z (CLARIDEN-21), corrected bounds
|
||||
### 2026-10-19T09:00Z → 2026-10-19T10:10Z (CLARIDEN-57, ex-20) and 2026-10-19T20:40Z → 2026-10-19T21:30Z (CLARIDEN-58, ex-21)
|
||||
No data; the common gaps with other stations are as described (not re-read on the other stations: the descriptions were validated). High confidence on the bounds.
|
||||
|
||||
### 2026-10-20T00:10Z → 2026-10-20T00:40Z (CLARIDEN-22, corrected)
|
||||
### 2026-10-20T00:10Z → 2026-10-20T00:40Z (CLARIDEN-59, ex-22)
|
||||
- **Phenomenon**: A step of the camera that the compensation does not erase.
|
||||
- **Precedents**: WILDSTRUBEL-200 (a camera tilt not caught by the compensation, Displacement).
|
||||
- **Family**: Displacement. The cause of the camera step is not established, and remainders stay on D-306-B and D-302-B.
|
||||
@@ -60,7 +62,7 @@ No data; the common gaps with other stations are as described (not re-read on th
|
||||
- **Images**: 00:00 and 01:00 (zone thumbnails): work lights at the far end of the tunnel.
|
||||
- **Confidence**: high on the jump; medium on what stays.
|
||||
|
||||
### 2026-10-11T08:50Z → 2026-10-11T09:10Z (new)
|
||||
### 2026-10-11T08:50Z → 2026-10-11T09:10Z (CLARIDEN-50)
|
||||
- **Phenomenon**: none in the catalogue exactly. It is close to "The base changes without a reference lost", for a single measurement.
|
||||
- **Precedents**: none useful.
|
||||
- **Family**: Displacement: a jump then the return, without an established cause. The error_value is flat, so it is not Visibility.
|
||||
@@ -68,15 +70,10 @@ No data; the common gaps with other stations are as described (not re-read on th
|
||||
- **Images**: 09:00 (zone thumbnail): nothing in front.
|
||||
- **Confidence**: medium. It is clearly a common one-measurement jump, but small (about 0.1 px).
|
||||
|
||||
### 2026-10-11T14:00Z → 2026-10-13T02:00Z (new)
|
||||
- **Phenomenon**: The camera tilts little by little (here it straightens).
|
||||
- **Precedents**: BREITHORN-2 and BREITHORN-11 (reviewed): slow tilt, incomplete compensation, Displacement. NEBRASKA-1 likewise.
|
||||
- **Family**: Displacement rather than Thermal displacement. The tilt does not come back at equal housing temperature: tilt ≈ +0.3 at 40.3 °C on the 13th, ≈ −0.6 at 40.6 °C on the 17th, ≈ −2.5 at 40.15 °C on the 19th. metrics.py gives r = +0.51 between tilt and temperature over the range: a weak link, not established.
|
||||
- **Measured** (2 h medians, `work/tilt_2h_11-13.txt`): tilt −2.33 (11th 12h) → +0.61 (13th 00h), in thousandths of a degree. Over the same time, corr_y moves as follows: D-306-B 0.026–0.034 → 0.064; D-304-B −0.071 → −0.053; D-303-B 0.059 → 0.07; D-302-B 0.064 → 0.036 at 13th 00h, then back to about 0.05. Raw y of all sensors, references included, rises together (overview, y panel).
|
||||
- **Images**: 11th 09:00, 13th 12:00: nothing in front.
|
||||
- **Confidence**: medium. The amplitude is small (2–3 noises per measurement, clear on the 2 h medians and the residuals), but the sign pattern is the same as on 17–20 with the opposite direction.
|
||||
### 2026-10-11T14:00Z → 2026-10-13T02:00Z (CLARIDEN-51): removed at the requalification
|
||||
The camera straightens a little and the remainder on D-306-B, D-304-B, D-303-B and D-302-B/PR_BG stays under 5 noises: see section 2. Its old reading (2 h medians, `work/tilt_2h_11-13.txt`) already put it at 2 to 3 noises per measurement.
|
||||
|
||||
### 2026-10-17T16:00Z → 2026-10-20T00:30Z (new)
|
||||
### 2026-10-17T16:00Z → 2026-10-20T00:30Z (CLARIDEN-53)
|
||||
- **Phenomenon**: The camera tilts little by little; incomplete compensation.
|
||||
- **Precedents**: BREITHORN-2 and BREITHORN-11 (the compensation corrects some targets better than others), SNCF01-7.
|
||||
- **Family**: Displacement, as above. The temperature drops on the 18th (39.6 °C at 08:00, 39.55 °C at the restart), but the tilt keeps going down until 19th 04:30 while the housing is back at 40.1 °C. A gap does not cut it: the movement is visible on both sides of CLARIDEN-19.
|
||||
@@ -84,7 +81,7 @@ No data; the common gaps with other stations are as described (not re-read on th
|
||||
- **Images**: 19th 04:00 (zone thumbnail): nothing in front. 18th 07:00: work lights at the far end.
|
||||
- **Confidence**: medium-high on the event and its bounds (start ±2 h, a slow onset). The family is uncertain between Displacement and a lagging thermal effect of the camera.
|
||||
|
||||
### 2026-10-18T06:30Z → 2026-10-18T06:50Z (new)
|
||||
### 2026-10-18T06:30Z → 2026-10-18T06:50Z (CLARIDEN-54)
|
||||
- **Phenomenon**: as on the 11th 09:00, in corr_x.
|
||||
- **Family**: Displacement (error_value flat).
|
||||
- **Measured**: group_flips: 7 targets at +3.2…+5.0 noises in corr_x at 06:40 (D-304-A 5.0, D-302_A 4.9, D-303-A 4.3, D-300-A 4.2, D-302-B/PR_BG 3.8, P-298-A 3.2). Rigid fit (base 06:00): tx ≈ 0, with PR-291 dx −0.06, PR-293 −0.03, PR-295 −0.03. The camera pan hits its minimum and the scale its maximum at 06:40 (overview, 16th–20th window). Back at 06:50.
|
||||
@@ -93,6 +90,17 @@ No data; the common gaps with other stations are as described (not re-read on th
|
||||
|
||||
## 2. What I left without a label
|
||||
|
||||
**Removed at the requalification (2026-11-17):**
|
||||
|
||||
- **CLARIDEN-51**, 2026-10-11T14:00Z → 2026-10-13T02:00Z, Displacement (remainder of the slight straightening of the camera on D-306-B, D-304-B, D-303-B, D-302-B/PR_BG). `ranges.py --k 5`, corr_x and corr_y: over its own range, **no point of any sensor** beyond 5 noises (0 ranges on the 29 sensors). Against the level before (11th 06:00–14:00, `--outside` the label): corr_y none; corr_x a single isolated point of D-304-B at 13th 00:30, +5.4 noises, which is a one-step spike, not the vertical movement of the label. Against the level after (13th 02:00–14th 12:00): none. The step of D-306-B in corr_y on 2 h medians (from about 0.03 to 0.064 px, noise 0.0099–0.0122 px) is about 3 noises; D-304-B and D-303-B are smaller. It is a camera movement that the compensation absorbs almost entirely: under the threshold, ordinary noise of the station.
|
||||
|
||||
**Kept near the threshold** (stated so the reader knows the margin):
|
||||
- CLARIDEN-50 (11th 09:00): D-304-A corr_y −5.3 noises (one measurement, `--rolling 6h`); D-301-A −6.7 and D-304-A −7.4 for the jump of 08:50→09:00.
|
||||
- CLARIDEN-54 (18th 06:40): D-302_A and D-304-A corr_x +5.4 noises each, at 06:40.
|
||||
- CLARIDEN-49 (return of row C): over its own range the median amplitude of the return is under 5 noises (12 h medians: D-301-C corr_x −0.043 → −0.085 px, about 3.6 noises; D-304-C corr_y −0.454 → −0.496, about 3.8; D-303-C −0.119 → −0.147, about 3); against its level after the return (16th 12:00–17th 16:00, `--outside` the label), D-301-C corr_x stays beyond 5 noises for 14 measurements on the 11th 12:00–18:10, extreme +6.1. It holds by the rule, at the margin; medium confidence.
|
||||
|
||||
**Before the requalification** (unchanged):
|
||||
|
||||
- One-measurement group flips of 5–7 targets at 3–4 noises (group_flips): 12th 01:00, 13th 21:30, 15th 09:00, 15th 13:30, 17th 03:40, 18th 06:00, 18th 09:50 (just after CLARIDEN-18), 19th 13:00. None reaches 5 noises on any target. They are the ordinary jitter of the pose (the rotation scatters by about ±0.002° from one measurement to the next). The 19th 04:20 instant (8 targets, max 4.1) falls inside the tilt label.
|
||||
- Isolated single-sensor spikes at ≈5 noises (P-299-B corr_x 15th 03:20, D-300-C corr_y 11th 02:00, P-299-A corr_y 15th 05:10, PR-284 corr_x 18th 11:20): on noisy targets (noise 0.01–0.03 px), single points within what each sensor does elsewhere.
|
||||
- The housing temperature dip of the 18th 08:00–10:00 is inside CLARIDEN-18. On its own, it moves only the pose already labeled.
|
||||
@@ -106,6 +114,27 @@ No data; the common gaps with other stations are as described (not re-read on th
|
||||
- Contradicted: CLARIDEN-14 and CLARIDEN-15 said "No camera movement", but the camera tilt does move by a few thousandths of a degree over days. This is small next to "a few hundredths" (DATA.md orders of magnitude), but enough to leave remainders of several noises on some targets. `stations.md` lists four references for CLARIDEN, while PR-296 is a fifth global reference retained at every instant.
|
||||
- The catalogue entry "The camera drifts away when the temperature of its housing drops, without a daily cycle" was tempting. The test "comes back at equal temperature" rejected it here.
|
||||
|
||||
## Requalification
|
||||
|
||||
Rule applied: a movement of the corr is kept if at least one target deviates by more than 5 of its own noises over the label's range (`tools/scripts/ranges.py --k 5`); for a slow drift the level is also taken outside the label (`--outside`, before and/or after), since its own median sits in the middle of the drift; No data is kept only when no sensor is measured. Outputs in `work/rq_*.txt`.
|
||||
|
||||
| id | bounds | family | command (all `python3 tools/scripts/ranges.py data/CLARIDEN --columns corr_x,corr_y`) | value | verdict |
|
||||
|---|---|---|---|---|---|
|
||||
| CLARIDEN-49 | 11th 06:00 → 16th 12:00 | Displacement | `--start 2026-10-11T06:00Z --end 2026-10-17T16:00Z --outside 2026-10-11T06:00Z/2026-10-16T12:00Z` | D-301-C corr_x, 14 measurements beyond 5, max +6.1 (11th 13:00); own window: one point 5.4 | kept, **rewritten** (it named CLARIDEN-51 "labeled separately"); loses nothing (it had no review) |
|
||||
| CLARIDEN-50 | 11th 08:50 → 09:10 | Displacement | `--rolling 6h --start 2026-10-11T00:00Z --end 2026-10-11T20:00Z` | D-304-A corr_y −5.3 at 09:00 | kept |
|
||||
| CLARIDEN-51 | 11th 14:00 → 13th 02:00 | Displacement | own range; `--outside` before (11th 06:00–14:00) and after (13th 02:00–14th 12:00) | no target beyond 5 in corr_y; one isolated corr_x point (D-304-B 5.4); about 3 noises on medians | **removed** |
|
||||
| CLARIDEN-52 | 15th 22:50 → 16th 10:30 | No data | `inventory.py --start/--end` | 69 steps absent for all sensors | kept |
|
||||
| CLARIDEN-17 | 16th 14:20 → 14:40 | No data | idem | 1 step absent for all sensors | kept (review 2026-11-17) |
|
||||
| CLARIDEN-53 | 17th 16:00 → 20th 00:30 | Displacement | `--start 2026-10-16T12:00Z --end 2026-10-20T04:00Z --outside 2026-10-17T16:00Z/2026-10-20T00:30Z` | D-303-B corr_y runs of 3–7 measurements beyond 5 through the 19th, max −7.4 (19th 12:00); D-304-C −6.8, D-303-C −6.1, D-302-B +5.8 | kept |
|
||||
| CLARIDEN-54 | 18th 06:30 → 06:50 | Displacement | `--rolling 6h --start 2026-10-18T00:00Z --end 2026-10-18T13:50Z` | D-302_A and D-304-A corr_x +5.4 at 06:40 | kept |
|
||||
| CLARIDEN-55 | 18th 08:50 → 09:30 | Visibility | idem | D-302-B/PR_BG corr_y +11.8, D-301-C corr_x −8.1, P-301-B corr_x +6.8 | kept |
|
||||
| CLARIDEN-56 | 18th 13:50 → 23:30 | No data | inventory | 57 steps absent for all sensors | kept |
|
||||
| CLARIDEN-57 | 19th 09:00 → 10:10 | No data | inventory | 4 steps absent for all sensors, between single measurements | kept |
|
||||
| CLARIDEN-58 | 19th 20:40 → 21:30 | No data | inventory | 3 steps absent for all sensors | kept |
|
||||
| CLARIDEN-59 | 20th 00:10 → 00:40 | Displacement | `--start 2026-10-19T18:00Z --end 2026-10-20T04:00Z --outside 2026-10-20T00:10Z/2026-10-20T04:00Z` | D-306-B corr_y 18 measurements beyond 5, max +7.4 | kept |
|
||||
|
||||
No label of the range was a missing-points label or a thermal label. The validator reports 0 errors and 3 overlaps (two short events inside the drifts 49 and 53, and the jump 59 at the end of 53): distinct events, kept.
|
||||
|
||||
## Difficulties
|
||||
|
||||
- The instructions file changed during the work (the weather moved to `data/<STATION>/weather/`); neither source has CLARIDEN.
|
||||
@@ -114,3 +143,5 @@ No data; the common gaps with other stations are as described (not re-read on th
|
||||
## Sources read
|
||||
|
||||
`instructions/analyst.md`, `tools/GUIDE.md`, `tools/DATA.md`, `labeling/families.md`, `labeling/labeling-rules.md`, `labeling/reading-rules.md`, `labeling/stations.md`, `labeling/auto/CLARIDEN.jsonl` (labels 10–25 at the edges), `work/existing.jsonl`, `work/spanning.jsonl`, precedents (WILDSTRUBEL-83/102/71/47/55/200, BREITHORN-2/11, SNCF01-7, NEBRASKA-1). Tools: inventory, overview (range; 16th–20th with --others and --rigid; 19th–20th and 18th at 10 min; 11th and 18th with --rigid), summary, plot, metrics, ranges (--rolling 12), thumbnails (zone); my scripts `scripts/tilt_vs_targets.py`, `scripts/group_flips.py`, `scripts/fig_tilt.py`. Images: 18th 08:00 and 09:00 whole; zone thumbnails 11th 09:00, 13th 12:00, 18th 07:00, 19th 04:00, 20th 00:00, 20th 01:00.
|
||||
|
||||
Requalification: `instructions/analyst.md`, `labeling/labeling-rules.md` (in full), `work/requalify_input.jsonl`, this analysis and `report.md` before rewriting; tools `inventory.py`, `ranges.py`, `summary.py` (12 h medians of row C).
|
||||
@@ -1,6 +1,5 @@
|
||||
{"start": "2026-10-11T06:00Z", "end": "2026-10-16T12:00Z", "family": "Displacement", "description": "The targets of row C slowly come back after their drift of the 6th to the 11th: D-301-C goes back down horizontally from the 11th to the 15th, D-304-C and D-303-C go back down vertically from the 12th until the first measurements after the gap of the night of the 15th to the 16th, then stay at that level until the 17th: the return is over. Their later movements are not part of it: the dip of the 18th and 19th follows the slow tilting of the camera and comes back at its jump of the 20th (both labeled separately). These movements do not follow the slow straightening of the camera of the 11th to the 13th (labeled separately) either: they continue while the camera is still. Nothing in front of the targets on the image of the 13th. The housing temperature stays almost constant over these days: no link with it. This is the return of the drift of the 6th to the 11th, labeled separately. Cause not established, in a tunnel under construction: a movement of these targets is not excluded. To be checked against the other measurements of the site; monitor this row."}
|
||||
{"start": "2026-10-11T06:00Z", "end": "2026-10-16T12:00Z", "family": "Displacement", "description": "The targets of row C slowly come back after their drift of the 6th to the 11th: D-301-C goes back down horizontally from the 11th to the 15th, D-304-C and D-303-C go back down vertically from the 12th until the first measurements after the gap of the night of the 15th to the 16th, then stay at that level until the 17th: the return is over. Their later movements are not part of it: the dip of the 18th and 19th follows the slow tilting of the camera and comes back at its jump of the 20th (both labeled separately). These movements do not follow the slight straightening of the camera of the 11th to the 13th either, which leaves only a remainder within the noise on the curves: they continue while the camera is still. Nothing in front of the targets on the image of the 13th. The housing temperature stays almost constant over these days: no link with it. This is the return of the drift of the 6th to the 11th, labeled separately. Cause not established, in a tunnel under construction: a movement of these targets is not excluded. To be checked against the other measurements of the site; monitor this row."}
|
||||
{"start": "2026-10-11T08:50Z", "end": "2026-10-11T09:10Z", "family": "Displacement", "description": "For one measurement, the corrected vertical curves of many targets drop together, then come back at the next one. D-304-A, D-301-A, D-303-A and D-302_A drop the most; D-301-C, D-302-B and PR_BG (same prism), P-299-B, P-301-B and P-299-A drop less. At that measurement, the whole scene shifts slightly in the image and the camera pose jumps (rotation, tilt), but the reference D-302-C does not follow the other references: the compensation is skewed for one measurement. The recognition error does not move. The image of that instant shows nothing in front of the targets. Cause not established; points to ignore, not a movement of the structure."}
|
||||
{"start": "2026-10-11T14:00Z", "end": "2026-10-13T02:00Z", "family": "Displacement", "description": "From the 11th to the 13th, the camera slowly straightens: its tilt rises, and the raw positions of all sensors, references included, move together vertically in the image. The compensation does not render this movement evenly. The corrected vertical curves of D-306-B, D-304-B and D-303-B rise a little, following the tilt step by step, then stay at their new level, the camera being still from the 13th; those of D-302-B and PR_BG (same prism) go down a little during the movement and come back soon after. These are the same targets as in the tilting of the 17th to the 19th (labeled separately), moving in the opposite direction. The recognition error stays at its level, and the images of the 11th and the 13th show nothing in front of the targets. The housing temperature rises a little over these days, but on other days the tilt is not the same at equal temperature: link not established. This is not a movement of the structure but the remainder of an incomplete compensation of the camera movement; the camera is to be monitored."}
|
||||
{"start": "2026-10-15T22:50Z", "end": "2026-10-16T10:30Z", "family": "No data", "description": "No measurement or image for almost twelve hours, on the night of 15 to 16, and no station metric. The gap starts at the same time, around 23:00, on the nine stations that were measuring then (LENZSPITZE only has its first measurements in the middle of that night, WILDSTRUBEL is already stopped), and their metrics stop at the same time on most of them; measurements and metrics resume at different times depending on the station, most of them in late morning. JUNGFRAU, whose metrics continue, accumulates unsent entries all night, sent in late morning, and yet its measurements for the night are missing from the data: a common cause outside the stations (transmission or reception of the data), not a shutdown of the stations; it is not established. In addition, at CLARIDEN, the station restarts on its battery: the voltage stays well below its usual level, without charge, until early afternoon, then charging resumes; its power supply was also missing that night. The curves are missing over the range; check the site power supply if it repeats."}
|
||||
{"start": "2026-10-16T14:20Z", "end": "2026-10-16T14:40Z", "family": "No data", "description": "One measurement is missing, for all sensors, a few hours after the resumption of the 16th: the curves have a short gap; normal voltage around it. The same gap falls at the same moment on the other stations measuring at that time (FLORIDA, LENZSPITZE, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-17T16:00Z", "end": "2026-10-20T00:30Z", "family": "Displacement", "description": "From the 17th to the 19th, the camera slowly tilts the other way: its tilt goes down, more and more after the restart that follows the outage of the 18th; it partly comes back during the 19th, then suddenly jumps back on the 20th (labeled separately). The raw positions of all sensors, references included, move together vertically in the image with it. The compensation does not render this movement evenly. The corrected vertical curves of D-302-B and PR_BG (same prism) rise. Those of D-303-B, D-304-B, P-301-B, D-306-B, D-303-C and D-304-C go down, and D-301-C rises a little horizontally. They follow the tilt step by step, come back partly with it on the 19th, and return at once at the camera jump of the 20th. The recognition error stays at its level, and the image of the 19th shows nothing in front of the targets. The housing temperature drops a little on the 18th and is low at the restart after the outage; but the tilt keeps going down after the housing has warmed again, and it does not come back at equal temperature: link not established. This is not a movement of the structure but the remainder of an incomplete compensation of the camera movement; the camera is to be monitored."}
|
||||
|
||||
@@ -1,65 +1,55 @@
|
||||
# CLARIDEN: verification of the labels, 11–20 October
|
||||
# CLARIDEN: labels of 11–20 October, requalified
|
||||
|
||||
You asked me to verify the 8 existing labels of 11 October 00:00 → 20 October 04:00 (UTC): keep, correct, remove or add.
|
||||
You asked me to requalify the labels of 11 October 00:00 → 20 October 04:00 (UTC) under the new rule: only what stands out from the noise is labelled.
|
||||
|
||||
## In short
|
||||
|
||||
One label holds as is, seven needed corrections (mostly bounds), and four labels were added. The main miss: the camera slowly tilts on the 11th–13th and the 17th–20th, and the corrected curves of a few targets follow it. Between the 17th and the 20th, do not read the vertical drift of D-302-B, D-303-B, D-304-B, P-301-B, D-306-B, D-303-C and D-304-C as a movement. No real movement of the structure is established; the jumps of D-306-B and D-302-B on the 20th remain to be checked.
|
||||
11 of the 12 labels stay. The slight straightening of the camera on the 11th–13th leaves too little on the curves to label, so it is removed. The curves cannot be trusted during the camera tilt of the 17th to the 20th, in a few short bumps, and in the gaps. No real movement of the structure is established. Row C comes back slowly on the 11th–16th, and D-306-B and D-302-B keep a jump after the 20th: both are still to be checked.
|
||||
|
||||
## Verification
|
||||
## Requalification
|
||||
|
||||
Kept 1, corrected 7, removed 0, added 4.
|
||||
Kept 10, rewritten 1, removed 1.
|
||||
|
||||
- CLARIDEN-15: the end moves from the 20th 00:20 to the 16th 12:00. The return of row C is complete on the 16th; after that the curves are flat. Their dip of the 18th–19th follows the camera tilt (new label). The description no longer says "no camera movement".
|
||||
- CLARIDEN-16: start 22:45 → 22:50, the last measurement before the gap (the station measures every 10 min).
|
||||
- CLARIDEN-18: start 09:00 → 08:50. At 09:00 the row A targets already jump vertically. The description now names them and says that the 09:00 image shows nothing in front.
|
||||
- CLARIDEN-19: start 13:45 → 13:50, the last measurement before the gap.
|
||||
- CLARIDEN-20: end 10:15 → 10:10, the first measurement after the gaps.
|
||||
- CLARIDEN-21: start 20:45 → 20:40, the last measurement before the gap.
|
||||
- CLARIDEN-22: bounds 00:15→00:45 → 00:10→00:40 (measurement instants; the scene starts moving at 00:20). The old description was wrong on most of the jumps. Most of them bring D-303-C, D-304-C, D-304-B, D-303-B and P-301-B back to where they were before the 17th. Only D-306-B (vertically) and D-302-B/PR_BG (horizontally) keep a new level.
|
||||
- Added: the camera straightens slowly, 11th 14:00 → 13th 02:00.
|
||||
- Added: the camera tilts slowly, 17th 16:00 → 20th 00:30.
|
||||
- Added: a one-measurement jump of many targets, 11th 09:00 (vertical).
|
||||
- Added: a one-measurement jump of many targets, 18th 06:40 (horizontal).
|
||||
- Spanning CLARIDEN-1 (P-300-B always rejected): correct in the range.
|
||||
- Spanning CLARIDEN-14: correct in the range (11th 00:00–06:00). Just before the range, though, its "no camera movement" is contradicted: the camera tilts from the 9th to the 11th, and D-306-B follows it.
|
||||
- CLARIDEN-51 (11th 14:00 → 13th 02:00, camera straightens slowly): removed. No target goes beyond 5 noises, measured against the level before, the level after, or the label's own range. The largest remainder, D-306-B in vertical, is about 3 noises (about 0.03 mm).
|
||||
- CLARIDEN-49 (11th 06:00 → 16th 12:00, slow return of row C): rewritten. Its description said the straightening of the 11th–13th was "labeled separately", which is no longer true. The label stays: against the level reached after the return, D-301-C stays beyond 5 noises for two hours on the 11th (up to about 6 noises).
|
||||
|
||||
## What happened
|
||||
|
||||
**The camera tilts slowly, and the compensation does not follow evenly.** From the 11th to the 13th the camera straightens a little. From the 17th to the 19th it tilts the other way, more strongly after the power cut of the 18th, then partly comes back on the 19th. All raw positions, references included, move together. A few targets do not get the same correction as the others. Vertically, D-302-B rises while D-303-B, D-304-B, P-301-B, D-306-B, D-303-C and D-304-C go down, by a few hundredths of a pixel, following the tilt step by step. They come back at once when the camera jumps back on the 20th. The housing temperature varies little, and the tilt does not come back at equal temperature, so a thermal link is not established. Cause: likely an incomplete compensation of a camera movement, as at BREITHORN.
|
||||
**The camera tilts slowly from the 17th to the 20th, and the correction does not follow evenly.** All targets and references move together in the image as the camera tilts. After the correction, a few targets keep part of the movement in vertical: D-302-B rises, while D-303-B, D-304-B, P-301-B, D-303-C and D-304-C go down. The error reaches about 0.1 to 0.2 mm at its deepest, on the 19th (up to about 7 noises). They come back at once when the camera jumps back on the 20th. On the 11th–13th the camera straightened a little the other way, but that time the correction absorbed it. Cause: likely an incomplete correction of a camera movement. The temperature does not explain it.
|
||||
|
||||

|
||||
|
||||
Top: the camera tilt; bottom: the vertical curves of five targets. In the grey zones they move with the tilt, and they jump back with it on the 20th.
|
||||
Top: the camera tilt. Bottom: the vertical curves of five targets. In the second grey zone (17th–20th) they follow the tilt and jump back with it on the 20th. In the first one (11th–13th) they stay within the noise.
|
||||
|
||||
**The camera jumps on the 20th, shortly after midnight.** The whole scene shifts in two measurements. Most targets come back to their normal level (see above). D-306-B jumps up beyond its usual level and stays there; D-302-B/PR_BG jump sideways and stay there. Work lights are visible at the far end of the tunnel on the images around it. The cause is unknown.
|
||||
**The camera jumps on the 20th, shortly after midnight.** The whole scene shifts in two measurements, and most targets return to where they were before the 17th. D-306-B jumps up and stays there: only about 0.06 mm, because it is 2 m from the camera. D-302-B/PR_BG jumps sideways by about 0.14 mm and stays there. Cause of the camera jump: unknown.
|
||||
|
||||
**Short disturbances.** On the 18th 08:50–09:30, a three-measurement bump on many targets comes with a rise of the recognition error on most sensors: likely reduced visibility, not seen on the image. On the 11th 09:00 and the 18th 06:40, many targets jump together for a single measurement. The references move slightly against each other, which skews the correction. The cause is unknown; these points are to be ignored.
|
||||
**Row C comes back slowly, 11th–16th.** After their drift of the 6th–11th, D-301-C comes back sideways by about 0.2 mm, and D-304-C and D-303-C come back down by about 0.13–0.15 mm. The camera is still while they move. This is just above the threshold. Cause: not established. In a tunnel under construction, a movement of these targets is possible.
|
||||
|
||||
**Gaps.** Four gaps: the night of the 15th–16th, a short one on the 16th, and two on the 19th. They are common to several stations. A power cut on the 18th from 13:50 to 23:30. All as already labeled; only the bounds were set on the measurement instants.
|
||||
**Short disturbances.** On the 18th from 08:50 to 09:30, a short bump on many targets (up to about 0.6 mm on D-301-C, 0.3 mm on D-302-B) comes with a rise of the recognition error on most sensors. Reduced visibility is likely, but it is not seen on the image. On the 11th at 09:00 and the 18th at 06:40, many targets jump together for one measurement (about 0.3–0.5 mm on row A). The references move slightly against each other, which skews the correction. Cause unknown; ignore these points.
|
||||
|
||||
**Gaps.** No measurement at all on the night of the 15th–16th, for one measurement on the 16th, and twice on the 19th: these gaps fall at the same time at other stations. On the 18th from 13:50 to 23:30 there was a power cut. The station is in a tunnel and has no weather station nearby.
|
||||
|
||||
## What to do
|
||||
|
||||
Check the camera mount and its fixing, since its tilt wanders by small amounts over days and jumped on the 20th. Compare D-306-B and D-302-B after the 20th with the other measurements of the site.
|
||||
Check the camera mount and its fixing: its tilt wanders a little over days and jumped on the 20th. Compare row C (11th–16th), D-306-B and D-302-B (after the 20th) with the other measurements of the site.
|
||||
|
||||
## Not established
|
||||
|
||||
- The cause of the slow tilt: a thermal effect with a delay is possible, but the temperature does not explain it at equal value. Watching the tilt against the housing temperature over more weeks would settle it.
|
||||
- The cause of the jump of the 20th, and whether the new level of D-306-B and D-302-B is real. Tunnel work at that time is the hypothesis to check with the site.
|
||||
- The cause of the slow tilt and of the jump of the 20th. Tunnel work at that time should be checked with the site.
|
||||
- Whether the slow return of row C and the new levels of D-306-B and D-302-B are real movements. The other measurements of the site would settle it.
|
||||
|
||||
## Labels
|
||||
|
||||
| Start (UTC) | End (UTC) | Family | Targets | In a few words |
|
||||
|---|---|---|---|---|
|
||||
| 2026-10-11 06:00 | 2026-10-16 12:00 | Displacement | D-301-C, D-303-C, D-304-C | slow return of row C, ends on the 16th (corrected) |
|
||||
| 2026-10-11 08:50 | 2026-10-11 09:10 | Displacement | row A, D-301-C, D-302-B/PR_BG, P-299-B… | one measurement, compensation skewed (added) |
|
||||
| 2026-10-11 14:00 | 2026-10-13 02:00 | Displacement | D-306-B, D-304-B, D-303-B, D-302-B/PR_BG | camera straightens slowly, remainder on a few targets (added) |
|
||||
| 2026-10-15 22:50 | 2026-10-16 10:30 | No data | all | night gap, common to the stations (bounds corrected) |
|
||||
| 2026-10-16 14:20 | 2026-10-16 14:40 | No data | all | one missing measurement (kept) |
|
||||
| 2026-10-17 16:00 | 2026-10-20 00:30 | Displacement | D-302-B/PR_BG, D-303-B, D-304-B, P-301-B, D-306-B, D-303-C, D-304-C | camera tilts slowly, remainder on a few targets (added) |
|
||||
| 2026-10-18 06:30 | 2026-10-18 06:50 | Displacement | row A, D-302-B/PR_BG | one measurement, compensation skewed (added) |
|
||||
| 2026-10-18 08:50 | 2026-10-18 09:30 | Visibility | row A, D-302-B/PR_BG, D-301-C, P-301-B, D-303-B | short bump with recognition error up (corrected) |
|
||||
| 2026-10-18 13:50 | 2026-10-18 23:30 | No data | all | power cut (bounds corrected) |
|
||||
| 2026-10-19 09:00 | 2026-10-19 10:10 | No data | all | common gaps (bounds corrected) |
|
||||
| 2026-10-19 20:40 | 2026-10-19 21:30 | No data | all | common gaps (bounds corrected) |
|
||||
| 2026-10-20 00:10 | 2026-10-20 00:40 | Displacement | D-306-B, D-302-B/PR_BG, D-303-C, D-304-C, D-304-B, D-303-B, P-301-B | camera jump; most targets come back, D-306-B and D-302-B keep a jump (corrected) |
|
||||
| 2026-10-11 06:00 | 2026-10-16 12:00 | Displacement | D-301-C, D-303-C, D-304-C | slow return of row C after its drift of the 6th–11th |
|
||||
| 2026-10-11 08:50 | 2026-10-11 09:10 | Displacement | row A, D-301-C, D-302-B/PR_BG, P-299-B… | one measurement, correction skewed |
|
||||
| 2026-10-15 22:50 | 2026-10-16 10:30 | No data | all | night gap, common to the stations |
|
||||
| 2026-10-16 14:20 | 2026-10-16 14:40 | No data | all | one missing measurement |
|
||||
| 2026-10-17 16:00 | 2026-10-20 00:30 | Displacement | D-302-B/PR_BG, D-303-B, D-304-B, P-301-B, D-306-B, D-303-C, D-304-C | camera tilts slowly, part left on a few targets |
|
||||
| 2026-10-18 06:30 | 2026-10-18 06:50 | Displacement | row A, D-302-B/PR_BG | one measurement, correction skewed |
|
||||
| 2026-10-18 08:50 | 2026-10-18 09:30 | Visibility | row A, D-302-B/PR_BG, D-301-C, P-301-B, D-303-B | short bump with recognition error up |
|
||||
| 2026-10-18 13:50 | 2026-10-18 23:30 | No data | all | power cut |
|
||||
| 2026-10-19 09:00 | 2026-10-19 10:10 | No data | all | common gaps |
|
||||
| 2026-10-19 20:40 | 2026-10-19 21:30 | No data | all | common gaps |
|
||||
| 2026-10-20 00:10 | 2026-10-20 00:40 | Displacement | D-306-B, D-302-B/PR_BG, D-303-C, D-304-C, D-304-B, D-303-B, P-301-B | camera jump; most come back, D-306-B and D-302-B keep a jump |
|
||||
Reference in new issue
Block a user