auto: labels requalified under the 5-noise rules (only what stands out from the noise): 32 analyses refined, the 6 paused periods verified, the long labels requalified with the fixes the period analysts found; 1153 -> 961 labels
- 32 analyses: each label kept, rewritten or removed by its analyst (section Requalification of the report; mm magnitudes where the targets have them) - SNCF01 x3, WILDSTRUBEL 2026-09-01 -> 2026-10-06 x3: verified from their existing labels under the new rules - long labels (no analysis): auto/analyses/long-labels/<STATION>/; NORDEND-169 and -195 run to 07/11, so NORDEND-283 and -284 (their continuation) are removed - reading-rules.md, stations.md: the citations of removed or rewritten labels point to their successor, or to [expert] Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
c779de7720
commit
ddb17c2189
321 files changed
+18464
-3426
No files matched your search
@@ -1,5 +1,7 @@
|
||||
# Labels: CLARIDEN, 2026-10-20T04:00Z → 2026-11-01T00:10Z (UTC)
|
||||
|
||||
> **Requalified 2026-11-17** under the new rule (`labeling-rules.md`, section 1: only what stands out from the noise of the corrected curves, 5 noises). 21 labels kept unchanged, 0 rewritten, 3 removed (CLARIDEN-27, CLARIDEN-43, CLARIDEN-67); details in section 2 and in "Requalification". The verification text below is the earlier work. Two of its entries are out of date: the 30/10 18:10 → 18:30 label (later CLARIDEN-67) and the thermal entries kept under D-117 (CLARIDEN-27, -43).
|
||||
|
||||
The task was to verify the 21 labels already on the range (`work/existing.jsonl`, all reviewed 2026-11-17) and the one spanning label (CLARIDEN-1).
|
||||
|
||||
Result: 12 kept unchanged, 9 corrected, 0 removed, 3 added; 24 labels in `labels.jsonl`. Labels are built from `existing.jsonl` by `scripts/build_labels.py`, so the kept ones are byte-identical apart from the dropped `id`. `validate.py` reports 0 errors. Its 8 "overlaps to look at" are distinct events on different target rows (row C drift, row B moves, row A jolts and returns). A script checked that every bound is a measurement instant of the station (10 min rate, minutes :00 to :50).
|
||||
@@ -93,6 +95,43 @@ Kept and corrected labels are justified in the table above. Below are the three
|
||||
- **ranges --k 4 --instants 4**: every group instant falls inside a labelled moment. The 30/10 18:20 group stays under 4 noises per sensor there but was found by its coherence; it is labelled.
|
||||
- **Weather**: CLARIDEN has no `weather/` folder (a tunnel with no Swiss position), so no weather is available. The instruction in effect (re-read after it changed during the session) reads the weather from `data/<STATION>/weather/`.
|
||||
|
||||
- **Removed by the requalification (2026-11-17)**:
|
||||
- **CLARIDEN-27**, 2026-10-22T08:00Z → 09:20Z, Thermal displacement. Its own description says the camera moves and the compensation absorbs it. Level and noise taken outside the label, window 21/10 20:00 → 22/10 09:20: no target is beyond 5 noises over 08:50 → 09:20, the part after the view obstruction. Earlier in the label, the corrected curves do pass 5 noises (D-301-C corr_x −12.1, D-303-B corr_y −8.8, D-302-B/PR_BG corr_y +8.5, up to 08:50), but that is the bump of the Visibility label CLARIDEN-61, which stays. This is a compensated camera thermal movement, so it is not labelled.
|
||||
- **CLARIDEN-43**, 2026-10-31T23:10Z → 2026-11-01T00:10Z, Thermal displacement. Same case. Level from 31/10 12:00, no target beyond 5 noises over 23:20 → 00:10. The deviations of 22:40 → 23:20 (P-301-B corr_x +11.2, D-301-C −9.4, D-302-B corr_y +7.7, D-304-B −7.0) belong to the Visibility label CLARIDEN-71, which stays. Compensated thermal: removed.
|
||||
- **CLARIDEN-67**, 2026-10-30T18:10Z → 18:30Z, Displacement (the one-measurement jump through reference PR-291). Window 30/10 06:00 → 31/10 06:00, level and noise outside the label. The 18:20 jumps of row A in corr_x are D-300-A 4.2 noises (−0.094 px against a noise of 0.019), D-303-A 3.7, D-304-A 3.6, D-301-A about 3.7 and P-299-A about 1.8. They are the size of the ordinary jumps of the same day: largest jumps of 4.0 to 5.2 noises at other hours. `ranges.py --k 5` finds nothing in corr_x or corr_y, and `--k 2` finds nothing on the named targets at 18:20. It is under the threshold, so it is removed. The earlier analysis already noted "under 4 noises per sensor, found by its coherence".
|
||||
|
||||
## Requalification
|
||||
Commands, from the repository root:
|
||||
- `python3 scripts/requalify.py <folder> 5 outside`. For each non-No data label, this runs `tools/scripts/ranges.py data/CLARIDEN --columns corr_x,corr_y --k 5` on the label ± max(12 h, its length), with `--outside <label>` (level and noise outside the label). It keeps the ranges inside the label. Output: `work/rq/outside_k5.txt`.
|
||||
- For the steps and drifts, the level must be the one before the label, so the run uses `--outside <label start>/<window end>` on the named targets (`work/rq/before_level.txt`, `work/rq/extra.txt`, `work/rq/c36.txt`).
|
||||
- For the thermal labels, the level is the night: `--outside` the thermal hours, with the window starting the evening before (`work/rq/c68.txt`).
|
||||
|
||||
Values (largest deviation in noises of a named target inside the label):
|
||||
|
||||
| id | family | deviation | verdict |
|
||||
|---|---|---|---|
|
||||
| CLARIDEN-23 | Displacement | D-304-C corr_y +17.0, D-303-C +16.4, D-301-C corr_x +10.6 (level before 20/10) | kept |
|
||||
| CLARIDEN-24, -60, -64, -34, -37, -66 | No data | every sensor missing (inventory, earlier analysis) | kept |
|
||||
| CLARIDEN-61 | Visibility | D-301-C corr_x −13.7, D-302-B/PR_BG corr_y +9.0 | kept |
|
||||
| CLARIDEN-27 | Thermal displacement | nothing beyond 5 after the view obstruction; compensated | **removed** |
|
||||
| CLARIDEN-62 | Displacement | D-304-B corr_y +6.7 to +7.2, D-306-B +6.9 (window level), D-303-B +6.2 | kept |
|
||||
| CLARIDEN-29 | Displacement | D-304-B corr_y −7.6, D-302-B/PR_BG −7.5, D-303-B −6.0 (level before 17:00) | kept |
|
||||
| CLARIDEN-30 | Displacement | D-306-B corr_y +5.2 at 04:50 (level before 01:00); D-304-B +5.7 just after | kept, near the threshold |
|
||||
| CLARIDEN-31 | Displacement | D-306-B corr_y +13.4, D-302_A +8.4, D-304-B +8.4 | kept |
|
||||
| CLARIDEN-32 | Displacement | D-303-C corr_y −5.9, D-304-C −5.6, in repeated ranges 27/10 → 29/10 (level before 25/10 18:00) | kept, near the threshold |
|
||||
| CLARIDEN-63 | Displacement | P-298-A corr_y −12.8, D-301-A −10.6, D-304-A −9.6 (level before 25/10 19:10) | kept |
|
||||
| CLARIDEN-35 | Target issue | PR-284 corr_x +544, corr_y +449 | kept |
|
||||
| CLARIDEN-36 | Displacement | D-306-B corr_y −10.1 from 19:30, D-304-B −5.8 (level before) | kept |
|
||||
| CLARIDEN-65 | Target issue | D-302-B corr_y +20.2, corr_x −8.8, PR_BG corr_y −8.1 (level before) | kept |
|
||||
| CLARIDEN-67 | Displacement | row A corr_x 3.6 to 4.2 at 18:20 | **removed** |
|
||||
| CLARIDEN-68 | Thermal displacement | D-301-C corr_x +5.5 (09:40), +5.2 (10:20), +5.1 (11:20) against the night level, 4.1 to 4.7 in between until 13:00; D-304-C corr_y +5.2 (09:50); D-303-C corr_x −5.5 (10:50) | kept: the corrected curves keep part of the cycle, near the threshold |
|
||||
| CLARIDEN-69 | Visibility | D-301-C corr_x −9.7, D-302-B/PR_BG corr_y +6.2 | kept |
|
||||
| CLARIDEN-70 | Visibility | D-301-C corr_x −7.6, P-299-A +6.2, D-304-A +5.5 (reference PR-295 −10.0) | kept |
|
||||
| CLARIDEN-71 | Visibility | D-302-B/PR_BG corr_x +12.0, D-303-B +11.9, P-301-B +11.7 | kept |
|
||||
| CLARIDEN-43 | Thermal displacement | nothing beyond 5 after the view obstruction; compensated | **removed** |
|
||||
|
||||
No kept label rests in its description on what is no longer labelled, so none is rewritten. The kept ones are byte-identical to the input, without `id`, and keep their `review`. `validate.py`: 21 labels, 0 errors, 8 overlaps between distinct row events.
|
||||
|
||||
## 3. The documentation
|
||||
- **What helped**:
|
||||
- Rule 2 ("bounds are measurement instants, at the minute") drove 8 of the 9 corrections. The existing labels carried 15-minute-grid minutes (:15, :45) on a 10-minute station.
|
||||
@@ -108,4 +147,6 @@ Kept and corrected labels are justified in the table above. Below are the three
|
||||
- The instructions file and `tools/GUIDE.md` changed on disk during the session. The weather moved from a fetch command to `data/<STATION>/weather/`; CLARIDEN has neither a stations.txt place nor a weather folder, so the outcome is the same.
|
||||
|
||||
## Sources read
|
||||
`instructions/analyst.md` (twice), `tools/GUIDE.md`, `tools/DATA.md`, `labeling/families.md`, `labeling/labeling-rules.md`, `labeling/reading-rules.md`, `labeling/stations.md`, `labeling/auto/CLARIDEN.jsonl` (labels at and around the range: CLARIDEN-1, 5, 11–15, 20–22), `work/existing.jsonl`, `work/spanning.jsonl`, `request.json`, `~/aimsight-data/extraction/stations.txt` (CLARIDEN line, no place). Precedents: `precedents.py` (WYOMING-17, NIEDERHORN-126, CLARIDEN-11, NORDEND-65/89, SNCF01-42). Tools: inventory, overview (common, residuals, rigid at 10 min and 6 h, with --follow), ranges (--rolling 6, --instants 3 and 4), days --bounds --smoothing 5, metrics (3 h and 1 h), summary (10 min, 30 min, 1 h, 6 h), plot. Raw: displacement CSVs (instants of all stations around the gaps), `metrics/` BusVoltage, last_sync, link, GPU on 30/10. Images: 20261030T1800Z, 20261031T1200Z (whole). No quality metrics on this camera (empty columns).
|
||||
Requalification: `instructions/analyst.md`, `tools/GUIDE.md` (ranges), `labeling/labeling-rules.md` sections 1–3, `work/requalify_input.jsonl`, this analysis, `report.md`, `inventory.py` (distances, mm/px).
|
||||
|
||||
Earlier work: `instructions/analyst.md` (twice), `tools/GUIDE.md`, `tools/DATA.md`, `labeling/families.md`, `labeling/labeling-rules.md`, `labeling/reading-rules.md`, `labeling/stations.md`, `labeling/auto/CLARIDEN.jsonl` (labels at and around the range: CLARIDEN-1, 5, 11–15, 20–22), `work/existing.jsonl`, `work/spanning.jsonl`, `request.json`, `~/aimsight-data/extraction/stations.txt` (CLARIDEN line, no place). Precedents: `precedents.py` (WYOMING-17, NIEDERHORN-126, CLARIDEN-11, NORDEND-65/89, SNCF01-42). Tools: inventory, overview (common, residuals, rigid at 10 min and 6 h, with --follow), ranges (--rolling 6, --instants 3 and 4), days --bounds --smoothing 5, metrics (3 h and 1 h), summary (10 min, 30 min, 1 h, 6 h), plot. Raw: displacement CSVs (instants of all stations around the gaps), `metrics/` BusVoltage, last_sync, link, GPU on 30/10. Images: 20261030T1800Z, 20261031T1200Z (whole). No quality metrics on this camera (empty columns).
|
||||
@@ -2,7 +2,6 @@
|
||||
{"start": "2026-10-20T06:10Z", "end": "2026-10-20T06:30Z", "family": "No data", "description": "One measurement is missing, for all sensors: the curves have a short gap; the station nevertheless synchronizes at that moment, normal voltage. The same moment is also missing at LENZSPITZE, and at no other station: a common cause outside the station is possible, not established. Nothing to do.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-20T20:40Z", "end": "2026-10-20T21:40Z", "family": "No data", "description": "Five measurements are missing within one hour, for all sensors: the curves have a gap. The station is nevertheless running (continuous synchronizations, 21:00 image, normal voltage): the measurement is not made or not recorded. The 21:00 measurement is also missing at NIEDERHORN, and at no other station: a common cause is possible, not established. Nothing to do."}
|
||||
{"start": "2026-10-22T06:30Z", "end": "2026-10-22T08:50Z", "family": "Visibility", "description": "In two phases, from 06:40 to 06:50 then from 07:50 to 08:30, the recognition error of several targets and of the references D-302-C and PR-293 rises, and the corrected curves of the usual group make a bump that comes back: D-301-C horizontally, D-302-B and PR_BG vertically, P-301-B, D-304-B, D-304-C, and at the start D-302_A, P-298-A, D-304-A, D-303-A; between the two, D-302-B and PR_BG move once more. The camera housing temperature drops during these hours. The 08:00 image shows lights at the far end of the tunnel (machine or vehicle), nothing in front of the targets. Diffuse view obstruction of cause not established, the same as in the other episodes at the station. Curves to ignore over the range; the structure does not move."}
|
||||
{"start": "2026-10-22T08:00Z", "end": "2026-10-22T09:20Z", "family": "Thermal displacement", "description": "The camera housing temperature drops clearly on the morning of the 22nd, and the camera scale deviates with it, mostly after the curves have returned from the view obstruction of the same hour, then returns when the housing warms up. The corrected curves do not follow this deviation: the compensation absorbs it. Camera movement by thermal effect, deduced from its pose against the housing temperature; normal, nothing to do.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-22T08:50Z", "end": "2026-10-22T17:00Z", "family": "Displacement", "description": "The low targets of row B rise vertically during the day: D-306-B above all, D-302-B and PR_BG, D-304-B, D-303-B; the recognition error of a few of them rises a little. Workers are visible in the tunnel on the 12:00 image, and a frame appears very close to the camera at the top of the image at 13:00 (it stays there until the end of the batch): work around the station. The position in the image of D-306-B rises a little relative to the other targets, in the direction of its curve. The link between this work and the rise is not established. Evening descent, labeled separately. Cause not established, in a tunnel under construction: a movement of these targets is not excluded. To be checked against the other measurements of the site; monitor this row."}
|
||||
{"start": "2026-10-22T17:00Z", "end": "2026-10-23T10:30Z", "family": "Displacement", "description": "The low targets of row B go back down vertically, all at once on the evening of the 22nd then more slowly on the morning of the 23rd, to below their level from before their rise of the day: D-306-B above all, D-304-B, D-303-B, D-302-B and PR_BG. No camera movement; the frame installed on the 22nd stays at the top of the image (19:00 image), nothing else. The position in the image of D-306-B also goes down relative to the other targets. This is the return of the rise of the day, labeled separately, and it goes beyond it. Cause not established, in a tunnel under construction: a movement of these targets is not excluded. To be checked against the other measurements of the site; monitor this row.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-24T01:00Z", "end": "2026-10-24T05:00Z", "family": "Displacement", "description": "The low targets of row B (D-306-B above all, D-304-B, D-303-B) partly rise again vertically in the night of the 24th, toward their level from before the descent of the evening of the 22nd, without reaching it. No camera movement. Cause not established, in a tunnel under construction: a movement of these targets is not excluded. To be checked against the other measurements of the site; monitor this row.", "review": "2026-11-17"}
|
||||
@@ -16,9 +15,7 @@
|
||||
{"start": "2026-10-29T14:50Z", "end": "2026-10-29T15:10Z", "family": "No data", "description": "One measurement is missing, for all sensors: the curves have a short gap; the station nevertheless synchronizes at that moment, normal voltage. The same gap falls at the same moment on the other stations measuring at that time (LENZSPITZE, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-29T23:50Z", "end": "2026-10-30T00:10Z", "family": "Target issue", "description": "At midnight, D-302-B jumps vertically and a little horizontally and stays at this new level until the end of the batch; PR_BG, on the same prism, jumps in the opposite direction. The raw positions of the two sensors do not move, only their starting position has changed (the relative displacement jumps without any movement in the image): a configuration or processing change of these two sensors, not a movement of the structure. Check their configuration with the operator; do not read this jump as a movement, nor compare their curves before and after."}
|
||||
{"start": "2026-10-30T17:00Z", "end": "2026-10-30T17:50Z", "family": "No data", "description": "Four measurements are missing in less than an hour, for all sensors: the curves have a gap. The station's own record stops too: its minute-by-minute synchronizations are missing over the same half hour, while the 17:00 image exists and the voltage stays normal before and after, so it is not a lack of energy. The other stations measuring at that time (ALASKA, FLORIDA, JUNGFRAU, LENZSPITZE, NADELHORN, NORDEND, SNCF01, WYOMING) have their measurements: the cause is specific to the station, not established. The curves are missing over the range; nothing to do unless it repeats."}
|
||||
{"start": "2026-10-30T18:10Z", "end": "2026-10-30T18:30Z", "family": "Displacement", "description": "For the duration of one measurement, the left targets of row A (D-300-A, D-301-A, D-302_A, D-303-A, D-304-A, P-299-A, P-298-A) and PR-283, PR-284 jump together horizontally, then return at the next measurement; D-303-C and D-304-C move a little the other way. Their raw positions in the image do not move: it is the reference PR-291 that shifts alone horizontally for this measurement, its recognition error rising a little without reaching its threshold, and the compensation passes its shift into the targets. No image at that minute; nothing in front of the scene on the 18:00 and 19:00 images. Cause not established. Not a movement of the structure: point to ignore."}
|
||||
{"start": "2026-10-31T09:20Z", "end": "2026-10-31T15:00Z", "family": "Thermal displacement", "description": "The camera housing temperature rises a little in the late morning of the 31st, and the camera scale rises with it while the pan goes down, until early afternoon; they come back when the housing cools, mostly during the view obstruction of the early afternoon, labeled separately. The compensation absorbs most of it, but a few corrected curves follow a little over these hours and come back with it: D-301-C horizontally, D-304-C, D-303-C and D-304-B vertically. Only a light at the far end of the tunnel on the 12:00 image, nothing in front of the targets. Camera movement by thermal effect, deduced from its pose against the housing temperature; normal, nothing to do."}
|
||||
{"start": "2026-10-31T13:50Z", "end": "2026-10-31T15:10Z", "family": "Visibility", "description": "For one hour, the corrected curves of the usual group make a bump that comes back: D-301-C (horizontal), D-302-B and PR_BG (vertical), D-301-A, D-300-A, D-304-B, D-304-C, D-302_A, and for a moment the reference PR-295; the recognition error of a few sensors rises during the episode. Same signature as the other episodes of view obstruction at the station; cause not established. Curves to ignore over the range."}
|
||||
{"start": "2026-10-31T18:40Z", "end": "2026-10-31T20:00Z", "family": "Visibility", "description": "For the duration of a few measurements, the corrected curves of D-301-C, P-301-B, P-299-A, D-302-B and PR_BG, D-303-B make a bump that comes back, and the reference PR-295, which is seen less well from 18:50, leaves its level; it is rejected at 19:50 (its curve is missing at that measurement), without the targets moving because of it. View obstruction of cause not established; points to ignore."}
|
||||
{"start": "2026-10-31T22:20Z", "end": "2026-11-01T00:00Z", "family": "Visibility", "description": "The reference PR-295 is seen poorly: its spot is weaker (23:00 thumbnail), it is rejected at times and, between two rejections, it is poorly measured; the compensation changes basis, and at 22:50 many targets jump together then return, without any movement of their raw positions. Until 23:50, the curves of D-301-C, P-301-B, D-302-B and PR_BG stay shifted, then briefly cross to the other side, with the recognition error of several targets rising. The camera housing temperature drops clearly at that hour. Cause of the obstruction not established (same signature as the other episodes). The jumps are not a movement: curves to ignore over the range."}
|
||||
{"start": "2026-10-31T23:10Z", "end": "2026-11-01T00:10Z", "family": "Thermal displacement", "description": "The camera housing temperature drops clearly on the evening of the 31st, and the camera scale deviates with it, then partly returns when the housing warms up; the strongest deviation comes when the curves return from the view obstruction of the same hour. The corrected curves do not follow this deviation: the compensation absorbs it. Camera movement by thermal effect, deduced from its pose against the housing temperature; normal, nothing to do.", "review": "2026-11-17"}
|
||||
@@ -1,83 +1,83 @@
|
||||
# CLARIDEN: verification of the labels, 20 October to 1 November
|
||||
# CLARIDEN: labels requalified, 20 October to 1 November
|
||||
|
||||
You asked me to verify the 21 labels already placed on this range (keep, correct, remove, add).
|
||||
You asked me to requalify the labels of this range under the new rule: label only what stands out from the noise of the corrected curves.
|
||||
|
||||
## In short
|
||||
|
||||
The 21 labels hold. I removed none and moved no event; 9 needed fixes, mostly start and end times that fell between two measurements. I added 3 events they had missed.
|
||||
21 labels stay as they were and 3 are removed. Two of the removed ones were camera warmth movements that the correction cancels, and the third was a jump too small to stand out from the noise.
|
||||
|
||||
Outside the labelled moments the curves can be trusted. Inside them, the brief jumps (22nd morning, 30th evening, 31st) are not movements.
|
||||
Outside the labels, the curves can be trusted. Inside the view-obstruction labels (22nd morning, 31st afternoon and evening), they cannot.
|
||||
|
||||
Several target rows move slowly on their own, in the image, then partly come back; the cause is not established. A movement of these targets is not excluded.
|
||||
Rows of targets move slowly on their own, by up to about half a millimetre, then partly come back. The cause is unknown, and a real movement of these targets is not excluded.
|
||||
|
||||
## Verification
|
||||
## Requalification
|
||||
|
||||
Kept 12, corrected 9, removed 0, added 3. The one long label that crosses the range (CLARIDEN-1, target P-300-B always rejected) holds.
|
||||
Kept 21, rewritten 0, removed 3. The threshold: a target must move more than 5 times its own noise. A camera movement that the correction cancels is not labelled.
|
||||
|
||||
- CLARIDEN-25: 20:45 → 21:45 becomes 20:40 → 21:40, the measurements on either side of the gap.
|
||||
- CLARIDEN-26: end 08:45 becomes 08:50, the first measurement where the curves are back.
|
||||
- CLARIDEN-28: start 08:45 becomes 08:50, when the row B rise is first seen.
|
||||
- CLARIDEN-33: end 15:15 becomes 15:10, the first measurement after the gap.
|
||||
- CLARIDEN-38: 23:45 → 00:15 becomes 23:50 → 00:10. The jump is exactly at 00:00.
|
||||
- CLARIDEN-39: end 17:45 becomes 17:50. I also rewrote the description: the gap belongs to CLARIDEN alone. All the other stations measured. The station's own minute-by-minute record stops for half an hour, while the 17:00 image exists and the voltage is normal.
|
||||
- CLARIDEN-40: start 13:45 becomes 13:50, the measurement before the first jump at 14:00.
|
||||
- CLARIDEN-41: start 18:45 becomes 18:40, the measurement before the first jump at 18:50.
|
||||
- CLARIDEN-42: start 22:15 becomes 22:20, the measurement before reference PR-295 is first rejected at 22:30.
|
||||
- Added: the slow return of row A in the vertical, 25/10 19:10 → 29/10 04:00.
|
||||
- Added: a one-measurement jump of row A caused by reference PR-291, 30/10 18:10 → 18:30.
|
||||
- Added: the camera moving with the housing warmth on the 31st, 09:20 → 15:00.
|
||||
|
||||
The station measures every 10 minutes. The old bounds at :15 and :45 were not measurement times, which is why most of these fixes are a few minutes.
|
||||
- CLARIDEN-27 (22/10 08:00 → 09:20, camera warmth): removed. The correction cancels it. After the view obstruction of that morning, no target goes beyond 5 noises. The larger deviations earlier in the label belong to the view obstruction, which keeps its own label.
|
||||
- CLARIDEN-43 (31/10 23:10 → 01/11 00:10, camera warmth): removed for the same reason. Nothing goes beyond 5 noises after 23:20. The jumps before that belong to the view-obstruction label of that evening.
|
||||
- CLARIDEN-67 (30/10 18:10 → 18:30, one-measurement jump of row A through reference PR-291): removed. The jump is 3.6 to 4.2 noises, about 0.3 to 0.4 mm. Ordinary jumps of the same day are that size.
|
||||
|
||||
## What happened
|
||||
|
||||
**Rows of targets that move slowly, alone** (20th to 29th; likely real, cause unknown). Row C rises from the 20th to the 25th, then partly comes back. Row B rises on the 22nd, drops below its level, and partly recovers. Row B steps down on the 28th. Row A rises in jolts on the 24th and 25th. These were already labelled. What was missing is row A's vertical return: from the 26th to the 29th it comes back to about where it was before the jolts, while its horizontal stays shifted. These targets really move in the image against the others. The camera is not involved and the temperature is flat.
|
||||
**Rows of targets that move slowly, alone** (20th to 29th; likely real, cause unknown).
|
||||
- Row C rises from the 20th to the 25th: D-304-C, D-303-C and D-301-C, by about half a millimetre. It then comes back partway by the 29th.
|
||||
- The low row B (D-304-B, D-303-B, D-302-B) rises on the 22nd. It drops below its earlier level on the evening of the 22nd, by about 0.2 to 0.35 mm, then partly recovers in the night of the 24th. It steps down again on the evening of the 28th. D-306-B moves the most in the image, but it is only 2 m from the camera, so this is less than 0.1 mm.
|
||||
- Row A jolts on the 24th and 25th. From the 26th to the 29th its vertical comes back by about half a millimetre, while its horizontal stays shifted.
|
||||
|
||||
These targets really move in the image against the others. The camera does not move and the temperature is flat. Two of these labels sit just above the threshold: row B's partial rise on the 24th and row C's return.
|
||||
|
||||

|
||||
Look at the grey zone: the four row A targets drift back down after the jumps of the 24th and 25th.
|
||||
Look at the grey zone: the four row A targets drift back down after the jolts of the 24th and 25th.
|
||||
|
||||
**A reference that moves alone for one measurement** (30th, 18:20; mechanism confirmed, cause unknown). Reference PR-291 shifts slightly for one measurement. The correction carries that shift into the left-hand targets, which jump horizontally and come back at once. The targets themselves do not move in the image. One point to ignore.
|
||||
**View obstructions** (22nd morning; 31st early afternoon, evening and late evening; cause unknown). The corrected curves of the same group of targets bump and come back: D-301-C, D-302-B, P-301-B, and sometimes row A. On the 31st, reference PR-295 is also seen badly, and the correction makes many targets jump together. None of this is a movement.
|
||||
|
||||
**Camera warmth on the 31st** (likely). From late morning, the housing warms by less than a degree. The camera's apparent zoom and its horizontal angle drift with it, then come back in the early afternoon when it cools. The correction absorbs most of it, but D-301-C, D-304-C, D-303-C and D-304-B follow a little. This is normal.
|
||||
**Camera warmth on the 31st** (likely). In the late morning the camera housing warms by less than a degree. The correction does not cancel all of it: D-301-C stays shifted in the horizontal by just over 5 noises for a few hours, about a quarter of a millimetre, then comes back. This is normal. The two other camera warmth episodes, on the 22nd and the 31st evening, are fully cancelled by the correction and are no longer labelled.
|
||||
|
||||

|
||||
In the grey zone, D-304-C (bottom) and D-301-C (top) shift slightly, then come back. The sharp dips just after, at 19:00 and around 23:00 are the view-obstruction episodes already labelled.
|
||||
In the grey zone, D-301-C (top) and D-304-C (bottom) shift slightly, then come back.
|
||||
|
||||
**Other events.**
|
||||
- On the 27th at 12:10, PR-284 has one false point several pixels away. Its spot has been weak since the 24th.
|
||||
- At midnight on the 30th, D-302-B and PR_BG jump without moving in the image: their starting position was changed, so do not compare their curves before and after (about 0.9 mm on D-302-B).
|
||||
- Six gaps where the station delivers nothing. Four of them fall on several stations at once; the one of the 30th at 17:00 is CLARIDEN's alone.
|
||||
|
||||
No weather is available for this station (a tunnel without a weather folder).
|
||||
|
||||
## What to do
|
||||
|
||||
Compare rows A, B and C with the site's other measurement systems for 20–29 October.
|
||||
- Compare rows A, B and C with the site's other measurement systems for 20–29 October.
|
||||
- Check with the operator why the starting position of D-302-B and PR_BG changed on the 30th.
|
||||
- Look at target PR-284 if its false points repeat.
|
||||
|
||||
## Not established
|
||||
|
||||
- The cause of the slow row movements: the site's other measurements would settle whether the structure moved.
|
||||
- The cause of the PR-291 shift on the 30th: there is no image at that minute.
|
||||
- The cause of the view obstructions: an image during an episode would tell.
|
||||
- The cause of the station's half-hour silence on the 30th at 17:00: the station's logs would tell.
|
||||
|
||||
## Labels
|
||||
|
||||
| Start (UTC) | End (UTC) | Family | Targets | In a few words |
|
||||
|---|---|---|---|---|
|
||||
| 2026-10-20 04:00 | 2026-10-25 18:00 | Displacement | D-301-C, D-304-C, D-303-C | row C slow rise (kept) |
|
||||
| 2026-10-20 06:10 | 2026-10-20 06:30 | No data | all | one measurement missing (kept) |
|
||||
| 2026-10-20 20:40 | 2026-10-20 21:40 | No data | all | five missing (bounds fixed) |
|
||||
| 2026-10-22 06:30 | 2026-10-22 08:50 | Visibility | row B, D-301-C, P-301-B | view obstruction (end fixed) |
|
||||
| 2026-10-22 08:00 | 2026-10-22 09:20 | Thermal displacement | camera | housing cold dip (kept) |
|
||||
| 2026-10-22 08:50 | 2026-10-22 17:00 | Displacement | D-306-B, row B | row B rises (start fixed) |
|
||||
| 2026-10-22 17:00 | 2026-10-23 10:30 | Displacement | D-306-B, row B | row B drops back (kept) |
|
||||
| 2026-10-24 01:00 | 2026-10-24 05:00 | Displacement | D-306-B, D-304-B, D-303-B | row B partly rises (kept) |
|
||||
| 2026-10-24 18:20 | 2026-10-25 19:10 | Displacement | row A, D-304-B, D-306-B, P-301-B | jolts (kept) |
|
||||
| 2026-10-25 18:00 | 2026-10-29 04:00 | Displacement | D-304-C, D-303-C | row C partial return (kept) |
|
||||
| 2026-10-25 19:10 | 2026-10-29 04:00 | Displacement | D-304-A, D-303-A, D-302_A, D-301-A | row A vertical return (added) |
|
||||
| 2026-10-26 14:30 | 2026-10-26 15:10 | No data | all | gap common to the stations (end fixed) |
|
||||
| 2026-10-27 09:00 | 2026-10-27 09:30 | No data | all | gap common to the stations (kept) |
|
||||
| 2026-10-27 12:00 | 2026-10-27 12:20 | Target issue | PR-284 | one false point (kept) |
|
||||
| 2026-10-28 19:20 | 2026-10-28 20:10 | Displacement | D-306-B, D-304-B, D-303-B | row B steps down (kept) |
|
||||
| 2026-10-29 14:50 | 2026-10-29 15:10 | No data | all | gap common to the stations (kept) |
|
||||
| 2026-10-29 23:50 | 2026-10-30 00:10 | Target issue | D-302-B, PR_BG | configuration jump (bounds fixed) |
|
||||
| 2026-10-30 17:00 | 2026-10-30 17:50 | No data | all | station silent on its own (rewritten) |
|
||||
| 2026-10-30 18:10 | 2026-10-30 18:30 | Displacement | row A via PR-291 | one-point jump (added) |
|
||||
| 2026-10-31 09:20 | 2026-10-31 15:00 | Thermal displacement | camera; D-301-C, D-304-C | housing warmth (added) |
|
||||
| 2026-10-31 13:50 | 2026-10-31 15:10 | Visibility | D-301-C, D-302-B, PR_BG | view obstruction (start fixed) |
|
||||
| 2026-10-31 18:40 | 2026-10-31 20:00 | Visibility | D-301-C, PR-295 | view obstruction (start fixed) |
|
||||
| 2026-10-31 22:20 | 2026-11-01 00:00 | Visibility | PR-295, many targets | reference seen poorly (start fixed) |
|
||||
| 2026-10-31 23:10 | 2026-11-01 00:10 | Thermal displacement | camera | housing cold dip (kept) |
|
||||
| 2026-10-20 04:00 | 2026-10-25 18:00 | Displacement | D-301-C, D-304-C, D-303-C | row C slow rise |
|
||||
| 2026-10-20 06:10 | 2026-10-20 06:30 | No data | all | one measurement missing |
|
||||
| 2026-10-20 20:40 | 2026-10-20 21:40 | No data | all | five measurements missing |
|
||||
| 2026-10-22 06:30 | 2026-10-22 08:50 | Visibility | D-301-C, D-302-B, PR_BG, P-301-B | view obstruction |
|
||||
| 2026-10-22 08:50 | 2026-10-22 17:00 | Displacement | D-306-B, D-304-B, D-303-B, D-302-B | row B rises |
|
||||
| 2026-10-22 17:00 | 2026-10-23 10:30 | Displacement | D-306-B, D-304-B, D-303-B, D-302-B | row B drops back, below its level |
|
||||
| 2026-10-24 01:00 | 2026-10-24 05:00 | Displacement | D-306-B, D-304-B, D-303-B | row B partly rises again |
|
||||
| 2026-10-24 18:20 | 2026-10-25 19:10 | Displacement | row A, D-304-B, D-306-B, P-301-B | jolts |
|
||||
| 2026-10-25 18:00 | 2026-10-29 04:00 | Displacement | D-304-C, D-303-C | row C partial return |
|
||||
| 2026-10-25 19:10 | 2026-10-29 04:00 | Displacement | D-304-A, D-303-A, D-302_A, D-301-A | row A vertical return |
|
||||
| 2026-10-26 14:30 | 2026-10-26 15:10 | No data | all | gap common to several stations |
|
||||
| 2026-10-27 09:00 | 2026-10-27 09:30 | No data | all | gap common to several stations |
|
||||
| 2026-10-27 12:00 | 2026-10-27 12:20 | Target issue | PR-284 | one false point |
|
||||
| 2026-10-28 19:20 | 2026-10-28 20:10 | Displacement | D-306-B, D-304-B, D-303-B | row B steps down |
|
||||
| 2026-10-29 14:50 | 2026-10-29 15:10 | No data | all | gap common to several stations |
|
||||
| 2026-10-29 23:50 | 2026-10-30 00:10 | Target issue | D-302-B, PR_BG | starting position changed |
|
||||
| 2026-10-30 17:00 | 2026-10-30 17:50 | No data | all | station silent on its own |
|
||||
| 2026-10-31 09:20 | 2026-10-31 15:00 | Thermal displacement | camera; D-301-C, D-304-C | housing warmth, partly kept by the curves |
|
||||
| 2026-10-31 13:50 | 2026-10-31 15:10 | Visibility | D-301-C, D-302-B, PR_BG | view obstruction |
|
||||
| 2026-10-31 18:40 | 2026-10-31 20:00 | Visibility | D-301-C, P-299-A, PR-295 | view obstruction |
|
||||
| 2026-10-31 22:20 | 2026-11-01 00:00 | Visibility | PR-295, many targets | reference seen badly, targets jump |
|
||||
@@ -0,0 +1,34 @@
|
||||
"""Requalify: per label, ranges.py at --k K in a margin window, level/noise outside the label
|
||||
(and optionally --rolling); keep the ranges overlapping the label; print the max |noises|."""
|
||||
import json, subprocess, sys, re
|
||||
from datetime import datetime, timedelta
|
||||
D = sys.argv[1]; K = sys.argv[2]; mode = sys.argv[3] # mode: outside | rolling:<N>
|
||||
ids = sys.argv[4].split(',') if len(sys.argv) > 4 else None
|
||||
F = '%Y-%m-%dT%H:%MZ'
|
||||
p = lambda s: datetime.strptime(s, F)
|
||||
for l in open(f'{D}/work/requalify_input.jsonl'):
|
||||
L = json.loads(l)
|
||||
if ids and L['id'] not in ids: continue
|
||||
if L['family'] == 'No data': continue
|
||||
s, e = p(L['start']), p(L['end'])
|
||||
m = max(timedelta(hours=12), (e - s))
|
||||
cmd = ['python3', 'tools/scripts/ranges.py', 'data/CLARIDEN', '--columns', 'corr_x,corr_y', '--k', K,
|
||||
'--start', (s - m).strftime(F), '--end', (e + m).strftime(F)]
|
||||
if mode == 'outside': cmd += ['--outside', f"{L['start']}/{L['end']}"]
|
||||
else: cmd += ['--rolling', mode.split(':')[1]]
|
||||
out = subprocess.run(cmd, capture_output=True, text=True).stdout
|
||||
col = None; hits = []
|
||||
for line in out.splitlines():
|
||||
mm = re.match(r'(corr_[xy]): ranges', line)
|
||||
if mm: col = mm.group(1); continue
|
||||
if line.startswith('=='): col = None; continue
|
||||
f = line.split()
|
||||
if col and len(f) >= 7 and re.match(r'\d{4}-', f[1] if len(f) > 1 else ''):
|
||||
rs, re_ = p(f[1]), p(f[2])
|
||||
if re_ < s or rs > e: continue
|
||||
# skip ranges touching the label edges only (start/end = untouched by rule)
|
||||
if re_ <= s or rs >= e: continue
|
||||
hits.append((abs(float(f[5])), f[0], col, f[1], f[2], f[3], f[5]))
|
||||
hits.sort(reverse=True)
|
||||
print(f"{L['id']} {L['start']}→{L['end']} {L['family']} [{mode} k{K}]: {len(hits)} ranges")
|
||||
for h in hits[:6]: print(' ', h[1], h[2], h[3], h[4], 'n=' + h[5], h[6], 'noises')
|
||||
Reference in new issue