auto: labels requalified under the 5-noise rules (only what stands out from the noise): 32 analyses refined, the 6 paused periods verified, the long labels requalified with the fixes the period analysts found; 1153 -> 961 labels

- 32 analyses: each label kept, rewritten or removed by its analyst (section Requalification of the report; mm magnitudes where the targets have them)
- SNCF01 x3, WILDSTRUBEL 2026-09-01 -> 2026-10-06 x3: verified from their existing labels under the new rules
- long labels (no analysis): auto/analyses/long-labels/<STATION>/; NORDEND-169 and -195 run to 07/11, so NORDEND-283 and -284 (their continuation) are removed
- reading-rules.md, stations.md: the citations of removed or rewritten labels point to their successor, or to [expert]

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
maximeandClaude Opus 5.5 committed 2026-11-17 23:58:00 +01:00
1 parent c779de7720
commit ddb17c2189
321 files changed
+18464 -3426

No files matched your search

@@ -2,7 +2,6 @@
{"start": "2026-10-20T06:10Z", "end": "2026-10-20T06:30Z", "family": "No data", "description": "One measurement is missing, for all sensors: the curves have a short gap; the station nevertheless synchronizes at that moment, normal voltage. The same moment is also missing at LENZSPITZE, and at no other station: a common cause outside the station is possible, not established. Nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-20T20:40Z", "end": "2026-10-20T21:40Z", "family": "No data", "description": "Five measurements are missing within one hour, for all sensors: the curves have a gap. The station is nevertheless running (continuous synchronizations, 21:00 image, normal voltage): the measurement is not made or not recorded. The 21:00 measurement is also missing at NIEDERHORN, and at no other station: a common cause is possible, not established. Nothing to do."}
{"start": "2026-10-22T06:30Z", "end": "2026-10-22T08:50Z", "family": "Visibility", "description": "In two phases, from 06:40 to 06:50 then from 07:50 to 08:30, the recognition error of several targets and of the references D-302-C and PR-293 rises, and the corrected curves of the usual group make a bump that comes back: D-301-C horizontally, D-302-B and PR_BG vertically, P-301-B, D-304-B, D-304-C, and at the start D-302_A, P-298-A, D-304-A, D-303-A; between the two, D-302-B and PR_BG move once more. The camera housing temperature drops during these hours. The 08:00 image shows lights at the far end of the tunnel (machine or vehicle), nothing in front of the targets. Diffuse view obstruction of cause not established, the same as in the other episodes at the station. Curves to ignore over the range; the structure does not move."}
{"start": "2026-10-22T08:00Z", "end": "2026-10-22T09:20Z", "family": "Thermal displacement", "description": "The camera housing temperature drops clearly on the morning of the 22nd, and the camera scale deviates with it, mostly after the curves have returned from the view obstruction of the same hour, then returns when the housing warms up. The corrected curves do not follow this deviation: the compensation absorbs it. Camera movement by thermal effect, deduced from its pose against the housing temperature; normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-22T08:50Z", "end": "2026-10-22T17:00Z", "family": "Displacement", "description": "The low targets of row B rise vertically during the day: D-306-B above all, D-302-B and PR_BG, D-304-B, D-303-B; the recognition error of a few of them rises a little. Workers are visible in the tunnel on the 12:00 image, and a frame appears very close to the camera at the top of the image at 13:00 (it stays there until the end of the batch): work around the station. The position in the image of D-306-B rises a little relative to the other targets, in the direction of its curve. The link between this work and the rise is not established. Evening descent, labeled separately. Cause not established, in a tunnel under construction: a movement of these targets is not excluded. To be checked against the other measurements of the site; monitor this row."}
{"start": "2026-10-22T17:00Z", "end": "2026-10-23T10:30Z", "family": "Displacement", "description": "The low targets of row B go back down vertically, all at once on the evening of the 22nd then more slowly on the morning of the 23rd, to below their level from before their rise of the day: D-306-B above all, D-304-B, D-303-B, D-302-B and PR_BG. No camera movement; the frame installed on the 22nd stays at the top of the image (19:00 image), nothing else. The position in the image of D-306-B also goes down relative to the other targets. This is the return of the rise of the day, labeled separately, and it goes beyond it. Cause not established, in a tunnel under construction: a movement of these targets is not excluded. To be checked against the other measurements of the site; monitor this row.", "review": "2026-11-17"}
{"start": "2026-10-24T01:00Z", "end": "2026-10-24T05:00Z", "family": "Displacement", "description": "The low targets of row B (D-306-B above all, D-304-B, D-303-B) partly rise again vertically in the night of the 24th, toward their level from before the descent of the evening of the 22nd, without reaching it. No camera movement. Cause not established, in a tunnel under construction: a movement of these targets is not excluded. To be checked against the other measurements of the site; monitor this row.", "review": "2026-11-17"}
@@ -16,9 +15,7 @@
{"start": "2026-10-29T14:50Z", "end": "2026-10-29T15:10Z", "family": "No data", "description": "One measurement is missing, for all sensors: the curves have a short gap; the station nevertheless synchronizes at that moment, normal voltage. The same gap falls at the same moment on the other stations measuring at that time (LENZSPITZE, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-17"}
{"start": "2026-10-29T23:50Z", "end": "2026-10-30T00:10Z", "family": "Target issue", "description": "At midnight, D-302-B jumps vertically and a little horizontally and stays at this new level until the end of the batch; PR_BG, on the same prism, jumps in the opposite direction. The raw positions of the two sensors do not move, only their starting position has changed (the relative displacement jumps without any movement in the image): a configuration or processing change of these two sensors, not a movement of the structure. Check their configuration with the operator; do not read this jump as a movement, nor compare their curves before and after."}
{"start": "2026-10-30T17:00Z", "end": "2026-10-30T17:50Z", "family": "No data", "description": "Four measurements are missing in less than an hour, for all sensors: the curves have a gap. The station's own record stops too: its minute-by-minute synchronizations are missing over the same half hour, while the 17:00 image exists and the voltage stays normal before and after, so it is not a lack of energy. The other stations measuring at that time (ALASKA, FLORIDA, JUNGFRAU, LENZSPITZE, NADELHORN, NORDEND, SNCF01, WYOMING) have their measurements: the cause is specific to the station, not established. The curves are missing over the range; nothing to do unless it repeats."}
{"start": "2026-10-30T18:10Z", "end": "2026-10-30T18:30Z", "family": "Displacement", "description": "For the duration of one measurement, the left targets of row A (D-300-A, D-301-A, D-302_A, D-303-A, D-304-A, P-299-A, P-298-A) and PR-283, PR-284 jump together horizontally, then return at the next measurement; D-303-C and D-304-C move a little the other way. Their raw positions in the image do not move: it is the reference PR-291 that shifts alone horizontally for this measurement, its recognition error rising a little without reaching its threshold, and the compensation passes its shift into the targets. No image at that minute; nothing in front of the scene on the 18:00 and 19:00 images. Cause not established. Not a movement of the structure: point to ignore."}
{"start": "2026-10-31T09:20Z", "end": "2026-10-31T15:00Z", "family": "Thermal displacement", "description": "The camera housing temperature rises a little in the late morning of the 31st, and the camera scale rises with it while the pan goes down, until early afternoon; they come back when the housing cools, mostly during the view obstruction of the early afternoon, labeled separately. The compensation absorbs most of it, but a few corrected curves follow a little over these hours and come back with it: D-301-C horizontally, D-304-C, D-303-C and D-304-B vertically. Only a light at the far end of the tunnel on the 12:00 image, nothing in front of the targets. Camera movement by thermal effect, deduced from its pose against the housing temperature; normal, nothing to do."}
{"start": "2026-10-31T13:50Z", "end": "2026-10-31T15:10Z", "family": "Visibility", "description": "For one hour, the corrected curves of the usual group make a bump that comes back: D-301-C (horizontal), D-302-B and PR_BG (vertical), D-301-A, D-300-A, D-304-B, D-304-C, D-302_A, and for a moment the reference PR-295; the recognition error of a few sensors rises during the episode. Same signature as the other episodes of view obstruction at the station; cause not established. Curves to ignore over the range."}
{"start": "2026-10-31T18:40Z", "end": "2026-10-31T20:00Z", "family": "Visibility", "description": "For the duration of a few measurements, the corrected curves of D-301-C, P-301-B, P-299-A, D-302-B and PR_BG, D-303-B make a bump that comes back, and the reference PR-295, which is seen less well from 18:50, leaves its level; it is rejected at 19:50 (its curve is missing at that measurement), without the targets moving because of it. View obstruction of cause not established; points to ignore."}
{"start": "2026-10-31T22:20Z", "end": "2026-11-01T00:00Z", "family": "Visibility", "description": "The reference PR-295 is seen poorly: its spot is weaker (23:00 thumbnail), it is rejected at times and, between two rejections, it is poorly measured; the compensation changes basis, and at 22:50 many targets jump together then return, without any movement of their raw positions. Until 23:50, the curves of D-301-C, P-301-B, D-302-B and PR_BG stay shifted, then briefly cross to the other side, with the recognition error of several targets rising. The camera housing temperature drops clearly at that hour. Cause of the obstruction not established (same signature as the other episodes). The jumps are not a movement: curves to ignore over the range."}
{"start": "2026-10-31T23:10Z", "end": "2026-11-01T00:10Z", "family": "Thermal displacement", "description": "The camera housing temperature drops clearly on the evening of the 31st, and the camera scale deviates with it, then partly returns when the housing warms up; the strongest deviation comes when the curves return from the view obstruction of the same hour. The corrected curves do not follow this deviation: the compensation absorbs it. Camera movement by thermal effect, deduced from its pose against the housing temperature; normal, nothing to do.", "review": "2026-11-17"}