auto: labels requalified under the 5-noise rules (only what stands out from the noise): 32 analyses refined, the 6 paused periods verified, the long labels requalified with the fixes the period analysts found; 1153 -> 961 labels

- 32 analyses: each label kept, rewritten or removed by its analyst (section Requalification of the report; mm magnitudes where the targets have them)
- SNCF01 x3, WILDSTRUBEL 2026-09-01 -> 2026-10-06 x3: verified from their existing labels under the new rules
- long labels (no analysis): auto/analyses/long-labels/<STATION>/; NORDEND-169 and -195 run to 07/11, so NORDEND-283 and -284 (their continuation) are removed
- reading-rules.md, stations.md: the citations of removed or rewritten labels point to their successor, or to [expert]

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
maximeandClaude Opus 5.5 committed 2026-11-17 23:58:00 +01:00
1 parent c779de7720
commit ddb17c2189
321 files changed
+18464 -3426

No files matched your search

@@ -1,6 +1,6 @@
# Labels: MICHIGAN, 2026-10-03T00:00Z → 2026-10-12T16:00Z (UTC)
Request: verify the three existing labels of the range (`work/existing.jsonl`: MICHIGAN-1, MICHIGAN-2, MICHIGAN-4) and the spanning label MICHIGAN-3; keep, correct, remove, add. DETECTORS: no.
Requalification of 2026-11-17 (new rule: only what stands out from the noise of the corrected curves, 5 own noises; `labeling-rules.md` §1): all four labels hold and are kept as they are, see section 2 and "Requalification" below. First request: verify the three existing labels of the range (`work/existing.jsonl`: MICHIGAN-1, MICHIGAN-2, MICHIGAN-4) and the spanning label MICHIGAN-3; keep, correct, remove, add. DETECTORS: no.
Station: indoors, in the same building as BREITHORN and NEBRASKA (`stations.md`); one measurement every 4 h (59 instants in the range, none missing, a pose at every instant); no image-quality metrics (export columns peak to snr empty); **no weather** (`data/MICHIGAN/weather/` does not exist: no MeteoSwiss data for this station). Images: one per measurement, uniformly dark indoor scene, so no moment of the day can be judged from them.
@@ -25,7 +25,7 @@ Added: one label, 04/10 20:00 → 05/10 12:00, Thermal displacement (below). Rem
- **Images**: thumbnails 05/10 12:00 and 16:00 (`pair.png`), as the label says
- **Confidence**: high for the facts; the cause stays deduced, as written
### 2026-10-04T20:00Z → 2026-10-05T12:00Z (added)
### 2026-10-04T20:00Z → 2026-10-05T12:00Z (MICHIGAN-17, added)
- **Phenomenon of the catalogue**: The camera drifts away when the temperature of its housing drops, without a daily cycle (sheltered)
- **Precedents**: MICHIGAN-2 (reviewed, same station, the next night: same signature; the sign of the corr_y is opposite because the pose moves the other way at that instant); MICHIGAN-9, MICHIGAN-10 (reviewed, same station later in October: brief housing drop, camera nods, corr of all targets move together, Thermal displacement); BREITHORN-29 (not reviewed, the same morning at the neighbouring camera, thermal). They gave the family and the way of writing it.
- **Family**: Thermal displacement: follows a drop of the housing temperature and comes back with it, nothing on the images, error_value at its level; not Displacement (it returns at equal temperature), not Visibility (no error rise, no nuisance)
@@ -33,7 +33,7 @@ Added: one label, 04/10 20:00 → 05/10 12:00, Thermal displacement (below). Rem
- **Images**: whole images 05/10 00:00 and 08:00: dark indoor scene, all spots present, nothing in front
- **Confidence**: medium: a small deviation (a few noises) at a 4 h cadence, but common to all the targets, with the signature of the reviewed MICHIGAN-2 of the next night
### 2026-10-06T00:00Z → 2026-10-06T20:00Z (MICHIGAN-2, corrected)
### 2026-10-06T00:00Z → 2026-10-06T20:00Z (MICHIGAN-18, the former MICHIGAN-2, corrected)
- **Phenomenon of the catalogue**: The camera drifts away when the temperature of its housing drops, without a daily cycle
- **Precedents**: MICHIGAN-2 itself (reviewed); MICHIGAN-9, -10 for the shape (dip, slow return)
- **Family**: Thermal displacement (unchanged)
@@ -41,7 +41,7 @@ Added: one label, 04/10 20:00 → 05/10 12:00, Thermal displacement (below). Rem
- **Images**: whole image 06/10 04:00: dark, nothing in front of the spots
- **Confidence**: medium for the end at 20:00 (one target clearly, two weakly), high for the event
### 2026-10-08T00:00Z → 2026-10-12T16:00Z (MICHIGAN-4, corrected)
### 2026-10-08T00:00Z → 2026-10-12T16:00Z (MICHIGAN-19, the former MICHIGAN-4, corrected)
- **Phenomenon of the catalogue**: The camera tilts little by little; then A compensation on two references
- **Precedents**: NEBRASKA-1 and BREITHORN-2 (reviewed, the neighbouring cameras, Displacement, same drift; NEBRASKA-1 dates the clearer step of 7-8 October and says its three references absorbed it, which is not fully the case here); MICHIGAN-4 itself for the expert sentence
- **Family**: Displacement: a drift of several days that does not come back at equal temperature (expert sentence), the targets do not move relative to each other; not Thermal displacement
@@ -51,11 +51,32 @@ Added: one label, 04/10 20:00 → 05/10 12:00, Thermal displacement (below). Rem
## 2. What I left without a label
**Requalification: no label removed.** Each of the four labels has at least one target beyond 5 of its own noises over its range (values in "Requalification"). The thermal labels MICHIGAN-17 and MICHIGAN-18 pass only just (5.0 to 6.1 noises at a single measurement); the corrected curves keep them, so they are not a camera movement fully absorbed by the compensation. None of the four is a label of missing points: the loss of REFPOU22 (MICHIGAN-3, spanning, outside this requalification) is only referred to by MICHIGAN-19.
The moments below were already left without a label; at the 5-noise threshold they stay so (the deviations given were at 3 noises or less):
- **03/10 08:00**: corr_x of COLH18', POUH18', POUH20' about −2.5 noises (5 targets beyond −3 noises on the whole-batch noise of `ranges.py --k 3`, at most −2.7 on the window noise), back at 12:00; the corr_y of the three references alternate around this instant (±4 to 6 noises at 00:00, 04:00, 08:00: jitter of the three-reference fit, REF42 off the targets by a few hundredths of a pixel in the rigid fit); housing temperature dip under half a degree, pose within 3 noises. One measurement, below the deviations of 05/10 and 06/10 and below the 5-noise threshold the rules use for cold mornings: not labelled.
- **04/10 08:00**: corr of the references ±3.4 noises, targets within 1.7: nothing on the curves of the targets.
- **The agitation after 09/10 12:00** (swings of all the targets from one measurement to the next, largest on 11/10 08:00-12:00 in corr_x, 11/10 20:00 and 12/10 08:00 in corr_y): the two-reference fragility described by MICHIGAN-3 and MICHIGAN-4. The largest swing (11/10 08:00 → 12:00) is about 4 noises of the post-loss step-to-step noise in corr_x, about 2 from the local level; smaller in corr_y than MICHIGAN-8 (17-18 October, labelled apart for a corr_y plunge). Not labelled apart; a reviewer may decide otherwise for 11/10 04:00 → 16:00.
- **Cold measurements of 11/10 04:00 and 12/10 00:00-08:00** (housing 31.75-31.9 °C): on two references the pose and the corr are too agitated to isolate a thermal response (tilt and corr_y within 1.5 noises of the post-loss noise); BREITHORN-31 labels 12 October at the neighbouring camera. No label here.
## Requalification
Commands (from the repository root; outputs in `work/requalify/`):
- `python3 tools/scripts/ranges.py data/MICHIGAN --columns corr_x,corr_y --k 5 --start 2026-10-03T00:00Z --end 2026-10-12T16:00Z` (`ranges_k5_full.txt`)
- the same on 2026-10-03T00:00Z → 2026-10-09T08:00Z (before the loss of REFPOU22, whose two-reference agitation inflates the noise of the full window), on the 14 targets, `--instants 1` (`ranges_k5_before_loss.txt`), then with `--rolling 6` (±1 day of measurements, under the drift; `ranges_k5_before_loss_rolling6.txt`)
| Id | Bounds | Family | Largest deviation (own noises) | Verdict |
|---|---|---|---|---|
| MICHIGAN-1 | 03/10 00:00 → 05/10 16:00 | Target issue | corr_y COLH21' −10.3 to −13.5 and REFH22' −8.6 to −11.5 at every measurement of the range (full window); jump at 05/10 12:00 → 16:00 of +16.0 (COLH21') and +15.8 (REFH22') noises (window before the loss) | kept as is (reviewed) |
| MICHIGAN-17 | 04/10 20:00 → 05/10 12:00 | Thermal displacement | corr_y COLH19N' +5.9 (plain) / +5.8 (rolling) at 05/10 00:00; POUH19N' +5.0 (plain) | kept as is |
| MICHIGAN-18 | 06/10 00:00 → 06/10 20:00 | Thermal displacement | corr_y at 06/10 04:00: POUH21'' −5.5 / −6.1 (rolling), COLH21'' −5.2 / −5.6, COLH20' −5.5 (rolling) | kept as is |
| MICHIGAN-19 | 08/10 00:00 → 12/10 16:00 | Displacement | corr_x before the loss: POUH18' +5.2 (08/10 08:00), COLH18' +5.5 (09/10 04:00); after it, every target beyond 5 noises almost at every measurement, up to COLH19N' +22.5, POUH20' +21.9, POUH19N' +19.7 at 11/10 12:00 (full window) | kept as is |
Counts: 4 kept, 0 rewritten, 0 removed. In mm (factors of `targets.csv`): the jump of the pair on 05/10 about 2.4 mm (COLH21', 40.5 m) and 3.0 mm (REFH22', 50.6 m); MICHIGAN-17 about 0.3 mm (COLH19N', POUH19N', 19 m); MICHIGAN-18 about 0.6 to 1.0 mm (COLH20' 30.5 m, POUH21'' and COLH21'' 40-42 m); MICHIGAN-19 at 11/10 12:00 about 0.6 mm at 9 m (COLH18') up to 4.7 mm at 41 m (COLH21) for corr_x deviations of 0.18 to 0.29 px: similar px, mm growing with the distance, the signature of a camera that turns, not of the structure.
## 3. The documentation
- `labeling-rules.md` §2 ("each edge checked sensor by sensor"; a camera cycle ends at the later return of the pose and of the curves) moved the end of MICHIGAN-2; §1 ("a signature found once is searched over the whole batch") found 05/10; §3 ("an event in one piece over several days makes one label; a change of speed does not cut it") kept MICHIGAN-4 as one label across the base change.
@@ -67,10 +88,14 @@ Added: one label, 04/10 20:00 → 05/10 12:00, Thermal displacement (below). Rem
## Difficulties
- Requalification: `ranges.py` has no `--out`; given it, argparse reads it as an abbreviation of `--outside` and fails on the folder path. The outputs were redirected to `work/requalify/` instead.
- `tools/GUIDE.md` (Conventions) restricts Bash to the tools; the trade allows scripts in `scripts/`: I used `scripts/steps.py`, `common.py`, `pertarget.py`, `pose.py`, `refgap.py`, `write_labels.py` (from the summary tables and the raw exports, read-only).
## Sources read
- Requalification: `instructions/analyst.md`, `work/requalify_input.jsonl`, this analysis, `labeling/labeling-rules.md` §1-2, `tools/GUIDE.md` (ranges), `inventory.py` (distances, mm/px), `ranges.py --k 5` ×3, `labeling/auto/MICHIGAN.jsonl` (labels of the range)
- `agents/agents/analyst.md`, `instructions/analyst.md`, `work/prompt.txt`, `work/existing.jsonl`, `work/spanning.jsonl`, `request.json`
- `tools/GUIDE.md`, `tools/DATA.md`; `labeling/families.md`, `labeling/labeling-rules.md`, `labeling/reading-rules.md`, `labeling/stations.md` (in full)
- `labeling/auto/MICHIGAN.jsonl` (labels of the range and edges); `labeling/auto/BREITHORN.jsonl`, `NEBRASKA.jsonl` (labels of 3-16 October)
@@ -1,32 +1,22 @@
# MICHIGAN: check of the labels from 3 to 12 October
# MICHIGAN: a misplaced pair of targets, two cold nights and a slowly tilting camera, 3 to 12 October
You asked to verify the three existing labels of 3 October 00:00 → 12 October 16:00 (UTC): keep, correct, remove, add.
## Verification
Kept: 1. Corrected: 2. Removed: 0. Added: 1.
- **MICHIGAN-1** (COLH21' and REFH22' on the same point until 5 October): kept as it is. The images of 12:00 and 16:00 on 5 October confirm it.
- **MICHIGAN-2** (6 October): end moved from 08:00 to 20:00. Most curves are back at 08:00, but COLH18S''' stays low until 16:00, as the camera and its temperature come back slowly. "At the end of the night" removed: the indoor images cannot show the time of day.
- **MICHIGAN-4** (camera tilt): start moved from 9 October 12:00 to 8 October 00:00. From 8 October 04:00, the camera tilts a little faster, and three references no longer hide all of it: the corrected curve in x of six targets already rises a little. The description now says so, and that the scale seen by the two remaining references rises after 9 October. The expert's words are kept.
- **Added** (4 October 20:00 → 5 October 12:00): the same cold-night camera movement as on 6 October, one night earlier.
- **MICHIGAN-3** (loss of REFPOU22, longer than the range): right within the range, nothing to change.
You asked to requalify the labels of 3 October 00:00 → 12 October 16:00 (UTC) under the new rule: keep only what stands out from the noise.
## In short
The labels were right in substance. Two had bounds that were too short, and one cold night was missing. Nothing in this range is a movement of the structure. From 9 October, with only two references left, the curves cannot be fully trusted.
All four labels stand out from the noise and stay as they were. None of them is a movement of the structure. Do not trust COLH21' and REFH22' before 5 October 16:00, or any target after 9 October 12:00, when only two references are left.
## What happened
**A badly placed pair of targets (3 to 5 October, confirmed).** COLH21' and REFH22' both measured the gap between two spots. At 16:00 on 5 October they were set back on their own spots. Their curves before then cannot be compared with those after.
**A badly placed pair of targets (3 to 5 October, confirmed).** COLH21' and REFH22' both measured the gap between two spots, not their own spots. Their corrected curve in y sat about 2 to 3 mm below their neighbours'. At 16:00 on 5 October they were set back on their own spots, and the curve jumped by about 2.4 mm (COLH21', 40 m away) and 3 mm (REFH22', 51 m away). Their curves from before cannot be compared with those from after.
![The pair before and after 16:00 on 5 October](pair.png)
Look at the red cross: between the two spots at 12:00, on its own spot at 16:00.
**The camera moves when its housing cools (5 and 6 October, likely).** On both nights the housing temperature dropped by about one degree. The camera nodded a little, and the curves of all the targets moved together, a little, for a few hours. They came back when the temperature rose. The targets did not move relative to each other.
**The camera moves when its housing cools (5 and 6 October, likely).** Both nights, the temperature in the camera housing dropped by about one degree. The camera nodded a little, and the corrected curves of all the targets moved together for a few hours. They came back when the temperature rose. The deviation is small: about 0.3 mm on the 5th (targets 19 m away), 0.6 to 1 mm on the 6th (targets 30 to 42 m away). That is just above the station's ordinary noise. The targets did not move relative to each other.
**The camera tilts slowly forward (8 to 12 October, likely).** The camera keeps nodding forward over these days, as do the cameras of BREITHORN and NEBRASKA in the same building. Up to 9 October, the three references cancel most of this movement. From 8 October they leave a small part of it. After REFPOU22 is lost (9 October at 12:00), only two references remain. Then the corrected curve in x of every target climbs steadily, and all curves jump back and forth from one measurement to the next.
**The camera slowly tilts forward (8 to 12 October, likely).** Over these days the camera keeps nodding forward. The cameras of BREITHORN and NEBRASKA, in the same building, do the same. With three references, the correction cancels most of this movement, and from 8 October a small part gets through. On 9 October at 12:00 the reference REFPOU22 is lost. From then on, with only two references left, the corrected curve in x of every target climbs steadily and jumps back and forth from one measurement to the next. At its worst (11 October 12:00), the curves are off by about 0.6 mm for the nearest targets (9 m) and up to about 4.7 mm for the farthest (41 m). The shift in the image is about the same for every target, so the error in mm grows with distance. That is what a turning camera does, not a moving structure. No weather data exist for this station (it is indoors).
![Six targets, corrected curves in x (top) and y (bottom); grey: the cold nights and the tilt](curves.png)
@@ -34,20 +24,25 @@ Look at the top panel: the small rise from 8 October, then the steady climb afte
## What to do
- Restore the prism of REFPOU22 on site, or add a third reference. Until then the curves since 9 October are not reliable.
- Restore the prism of REFPOU22 on site, or add a third reference. Until then, the curves since 9 October are not reliable.
- Check that COLH21' and REFH22' are configured as they are now.
- Keep watching the camera tilt, together with BREITHORN and NEBRASKA.
## Not established
- Why the cameras of the building tilt. Temperature does not explain it alone. Comparing the three cameras over several months would settle it.
- Whether the largest back-and-forth swing (11 October, 08:00 to 16:00) deserves its own label. It is left inside the two-reference labels for now.
- Why the cameras of the building tilt. Temperature does not explain it on its own. Comparing the three cameras over several months would settle it.
## Requalification
Kept: 4. Rewritten: 0. Removed: 0.
Each label has at least one target more than 5 times its own noise away from its usual level. The pair on 5 October: 16 noises. The night of 5 October: 5 to 6. The night of 6 October: 5.5 to 6. The tilt: up to 22 noises after 9 October.
## Labels
| Start (UTC) | End (UTC) | Family | Targets | In a few words |
|---|---|---|---|---|
| 2026-10-03 00:00 | 2026-10-05 16:00 | Target issue | COLH21', REFH22' | Both on the same point, reconfigured at 16:00 (kept) |
| 2026-10-04 20:00 | 2026-10-05 12:00 | Thermal displacement | all | Cold night, camera moves, small common shift (added) |
| 2026-10-06 00:00 | 2026-10-06 20:00 | Thermal displacement | all, COLH18S''' last | Cold night, camera moves, slow return (corrected) |
| 2026-10-08 00:00 | 2026-10-12 16:00 | Displacement | all | Camera tilts forward; the curves follow it, clearly after 9 October (corrected) |
| 2026-10-03 00:00 | 2026-10-05 16:00 | Target issue | COLH21', REFH22' | Both on the same point, reconfigured at 16:00 |
| 2026-10-04 20:00 | 2026-10-05 12:00 | Thermal displacement | all, COLH19N' and POUH19N' most | Cold night, camera moves, small common shift |
| 2026-10-06 00:00 | 2026-10-06 20:00 | Thermal displacement | all, POUH21'', COLH21'', COLH20' most | Cold night, camera moves, slow return |
| 2026-10-08 00:00 | 2026-10-12 16:00 | Displacement | all | Camera tilts forward; the curves follow it, clearly after 9 October |