auto: labels requalified under the 5-noise rules (only what stands out from the noise): 32 analyses refined, the 6 paused periods verified, the long labels requalified with the fixes the period analysts found; 1153 -> 961 labels

- 32 analyses: each label kept, rewritten or removed by its analyst (section Requalification of the report; mm magnitudes where the targets have them)
- SNCF01 x3, WILDSTRUBEL 2026-09-01 -> 2026-10-06 x3: verified from their existing labels under the new rules
- long labels (no analysis): auto/analyses/long-labels/<STATION>/; NORDEND-169 and -195 run to 07/11, so NORDEND-283 and -284 (their continuation) are removed
- reading-rules.md, stations.md: the citations of removed or rewritten labels point to their successor, or to [expert]

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
maximeandClaude Opus 5.5 committed 2026-11-17 23:58:00 +01:00
1 parent c779de7720
commit ddb17c2189
321 files changed
+18464 -3426

No files matched your search

@@ -1,68 +1,90 @@
# Labels: NEBRASKA, 2026-10-13T00:00Z → 2026-10-22T00:00Z (UTC)
Verification of the 4 existing labels of the range (work/existing.jsonl), all reviewed by the user on 2026-11-17. Cadence: one measurement every 4 h (52 instants in the range, 3 missing). REFCOLH22 rejected at every measurement of the range: the compensation runs on REFH22 and REFP''21 only (their reprojection error stays at zero), as NEBRASKA-2 says. No image quality metrics on this camera (the export columns from peak to snr are empty). **Weather**: NEBRASKA has no `weather/` folder, so there is no MeteoSwiss data. The station is indoors anyway (stations.md, and the images show a dark indoor scene).
Requalification, under the new rules (`labeling-rules.md` section 1: only what stands out from the noise of the corrected curves), of the 4 labels of this analysis (`work/requalify_input.jsonl`, all reviewed by the user on 2026-11-17). The reading was not redone: the verdicts of the previous analysis (kept in `work/analysis.before-requalify.md`) stand. Each label was checked against the 5-noise threshold only. Result: **4 kept unchanged, 0 rewritten, 0 removed**. `labels.jsonl` is the input without the id field, review fields included.
## Verdict per old id
- **NEBRASKA-3** (13-10 04:00 → 17-10 04:00, Displacement): **kept**. The corr_y of the top targets steps up between 04:00 and 08:00 on 13 Oct. COLJ20 goes from −0.051 to −0.002 to +0.032, POUJ20 from 0.047 to 0.084, POUJ19 from −0.007 to 0.032, POUH19 from 0.123 to 0.143. It stays high through 17-10 00:00 (COLJ20 0.041, POUJ20 0.082, COLH19 0.108, POUH19 0.145). At 17-10 04:00 every one of these targets is back at its 12 Oct level (COLJ20 −0.010, POUJ19 −0.025, POUJ20 0.053, COLJ19 0.034, COLH19 0.064, POUH19 0.120). So both bounds sit on the measurement before the first touched point and the measurement after the last. Pose: the tilt drops from its 12 Oct peak (29.66e-3 deg at 12-10 04:00) to 23.9e-3 at 15-10 20:00. The pan reaches its October minimum (−3.25e-3 deg at 15-10 16:00), then both go up again from 17 Oct. Housing temperature: 33.5 to 34 °C, stable. BREITHORN and MICHIGAN show the same pause in tilt (stations.py).
- **NEBRASKA-4** (15-10 20:00 → 16-10 12:00, No data): **kept**. Three measurements are missing (16-10 00:00, 04:00, 08:00), with no image between 20:00 and 12:00. NEBRASKA's metrics stop after 22:00 and come back at 11:00. The voltage is 14.14 V before the gap and 14.31 V after. stations.py over all the stations: from 23:00 there is no measurement on BREITHORN, CLARIDEN, FLORIDA, JUNGFRAU, MICHIGAN, NEBRASKA, NIEDERHORN, NORDEND and SNCF01 (nine stations). LENZSPITZE starts at 02:10, WILDSTRUBEL has no data, and the stations ALASKA, NADELHORN, SUSTENHORN and WYOMING have no data in this window. On JUNGFRAU, DB_not_uploaded climbs from 17 to 124 between 00:00 and 09:00, then falls to 0 at 11:00. Every claim in the description holds.
- **NEBRASKA-5** (16-10 20:00 → 17-10 20:00, Displacement): **kept**. COLJ19 corr_x goes 0.199 → 0.273 at 17-10 00:00 (largest jump of the range, 7.2 noises, ranges.py) and stays at 0.257–0.272 until 16:00. The raw x of COLJ19 moves +0.06 px while its neighbours move 0.00 to 0.01 px. Its rigid residual dx (overview.py --rigid, base 13-10 00:00) goes from 0.0015 to 0.070 and stays at 0.061–0.076 until 16:00. At 17-10 20:00 it is down to 0.033 in the residual and to 0.247 in corr_x: about half way back, so 20:00 is a defensible end. At 18-00 it is 0.020, then the long drift of NEBRASKA-6 takes over. The y of COLJ19 also falls on 17 Oct, but POUJ19, COLJ20 and POUJ20 fall with it (this is the end of NEBRASKA-3), so that part is not specific to COLJ19 and the description is right to mention only corr_x. COLJ19's error_value stays flat (0.071–0.074). The pose shows no step at 17-10 00:00 that the other targets do not absorb. Fixed thumbnails of COLJ19, with POUJ19 and COLJ20 as witnesses, at 16-10 16:00 and 20:00, 17-10 00:00, 12:00 and 20:00, and 18-10 00:00: the spot keeps the same shape and nothing is in front of it. The shift is a few hundredths of a pixel, too small to see.
- **NEBRASKA-7** (18-10 16:00 → 19-10 16:00, Thermal displacement): **kept**. The housing temperature has its October minimum so far on 19 Oct, 29.75 °C at 07:00 (the minimum before 19 Oct was 31.0 °C at 18-10 22:00). From 18-10 20:00, the corr_y rises: POUJ19 0.045 → 0.073 → 0.110 → 0.128 → 0.151 (08:00) → 0.130 → 0.077 (16:00), COLJ20 0.021 → 0.102 → 0.017, POUH20 to 0.069 at 08:00. At 19-10 08:00 the corr_x has its peak: COLH19 0.182, COLH20 0.142, COLH21 0.070, POUH19 0.266, COLJ20 0.573, POUH21 0.084. At the same moment the tilt peaks at 37.14e-3, the pan jumps to 2.08e-3 and the scale drops to its lowest (−42.1e-5). In days.py --bounds, 18 and 19 Oct are the only days of the range where the pose goes past 5 noises (tilt, rotation, scale). The references stay well seen: REFH22 error_value 0.155–0.168, REFP''21 0.028–0.040. The 08:00 peak returns at 12:00 to 16:00 with the temperature (32.5 °C at 12:00). The tilt does not come all the way back, because the long drift of NEBRASKA-6 keeps going underneath. The whole image at 19-10 08:00 shows the scene intact, with no obstacle.
Context. One measurement every 4 h (52 instants in the range, 3 missing). REFCOLH22 is rejected at every measurement, so the compensation runs on REFH22 and REFP''21 only (the long label NEBRASKA-2). The image quality columns are empty on this camera. **Weather**: NEBRASKA has no `weather/` folder, so there is no MeteoSwiss data. The station is indoors anyway. Distances and mm per px (`inventory.py`): POUJ20 7.9 m (3.10 mm/px), COLJ20 8.6 m (3.37), COLJ19 10.9 m (4.21), POUJ19 11.7 m (4.64), POUH19 16.8 m (6.72), POUH20 30.8 m (12.14), POUH21 37.8 m (14.87). COLH19, COLH20 and COLH21 have no sure factor (`?`), so they are given in px only.
## 1. My labels
The four labels are kept unchanged (labels.jsonl is identical to existing.jsonl, without the id field). The evidence for each is in the verdicts above. I add no label.
### 2026-10-13T04:00Z → 2026-10-17T04:00Z (NEBRASKA-3, kept)
- **Phenomenon of the catalogue**: "The camera tilts little by little" (here, a pause and slight backward movement), with "A compensation on two references".
- **Phenomenon of the catalogue**: "The camera tilts little by little" (here a pause and a slight backward movement), with "A compensation on two references".
- **Precedents**: NEBRASKA-1 and NEBRASKA-6 (the same camera before and after).
- **Family**: Displacement. It does not come back at equal temperature and its cause is not established, so it is not Thermal.
- **Measured**: see the verdict.
- **Images**: 13-10 04:00 and 08:00. Same scene, nothing in front.
- **Confidence**: high on the bounds; the cause remains not established.
- **Family**: Displacement. It does not come back at equal temperature, and its cause is not established, so it is not Thermal.
- **Measured**: `ranges.py --k 5` over 10-10 → 17-10 20:00 with the level computed outside the label (`--outside 2026-10-13T04:00Z/2026-10-17T04:00Z`). In corr_y: COLJ20 +7.7 noises (14-10 00:00, +0.100 px, about 0.34 mm), COLH19 +7.4 (14-10 00:00), POUJ19 +6.7 (14-10 00:00, +0.071 px, about 0.33 mm), POUH19 +6.4 (14-10 00:00, about 0.42 mm). COLJ20 and COLH19 stay beyond 5 noises at several instants up to 16-10 16:00. COLJ23's ranges come from its quantised corr_y (noise 0.0014 px, values on two levels): they are not part of the event. Previous verdict (bounds, pose, link with BREITHORN and MICHIGAN): unchanged.
- **Images**: 13-10 04:00 and 08:00 (previous analysis). Same scene, nothing in front.
- **Confidence**: high on the threshold and the bounds. The cause stays not established.
### 2026-10-15T20:00Z → 2026-10-16T12:00Z (NEBRASKA-4, kept)
- **Phenomenon of the catalogue**: "A gap common to several stations".
- **Precedents**: none needed.
- **Family**: No data.
- **Measured**: see the verdict.
- **Images**: none between 20:00 and 12:00 (the image gap is 960 min).
- **Family**: No data. The station delivers no measurement at all.
- **Measured**: `inventory.py --start 2026-10-15T12:00Z --end 2026-10-16T16:00Z`: 3 missing instants, between 15-10 20:00 and 16-10 12:00, for all the sensors (no partial curve). This is still a real No data under the new rule.
- **Images**: none between 20:00 and 12:00.
- **Confidence**: high.
### 2026-10-16T20:00Z → 2026-10-17T20:00Z (NEBRASKA-5, kept)
- **Phenomenon of the catalogue**: "A target or a small group jumps and stays shifted" (here a partial return).
- **Precedents**: none useful (precedents.py returns FLORIDA and WYOMING reference jumps, which are not this case).
- **Phenomenon of the catalogue**: "A target or a small group jumps and stays shifted" (here with a partial return).
- **Precedents**: none useful.
- **Family**: Displacement, because no cause is seen.
- **Measured**: see the verdict.
- **Images**: fixed thumbnails, see the verdict.
- **Confidence**: high on the jump. The end at 20:00 is within one measurement of the alternative (18-10 00:00).
- **Measured**: the COLJ19 corr_x jump from 16-10 20:00 to 17-10 00:00 is +0.074 px, 6.6 noises with the noise of the whole range and 11.1 noises with the noise outside NEBRASKA-3 (`ranges.py`). Against the level outside NEBRASKA-3, COLJ19 corr_x stays out: +10.5 noises at 17-10 00:00, 8.0 to 10.3 from 04:00 to 16:00, +6.5 at 20:00 (half way back). That is about +0.29 mm at its peak (4.21 mm/px). `ranges.py --rolling 3` does not flag it, because a step that lasts five measurements is followed by a level of ±3 measurements. A lasting jump is measured against its level before, so the outside run is the right one here.
- **Images**: fixed thumbnails (previous analysis). Nothing in front, and the shift is too small to see.
- **Confidence**: high.
### 2026-10-18T16:00Z → 2026-10-19T16:00Z (NEBRASKA-7, kept)
- **Phenomenon of the catalogue**: "The camera drifts away when the temperature of its housing drops" (sheltered, in a building).
- **Precedents**: NEBRASKA-8 to NEBRASKA-11 (the cold mornings at the end of the month).
- **Family**: Thermal displacement. It follows the temperature trough and comes back with it.
- **Measured**: see the verdict.
- **Images**: 19-10 00:00 and 08:00, indoor scene intact.
- **Confidence**: medium to high. The peak sits on top of the long drift.
- **Measured**: the corrected curves keep the movement beyond 5 noises.
- `ranges.py --k 5` over the whole range, with no rolling, at 19-10 08:00: POUH20 corr_y +7.0 noises, COLH21 corr_x +6.5, POUJ19 corr_y +5.7, COLJ20 corr_x +5.2. corr_y has no drift over the range that would bias this level. corr_x does: POUH20, COLJ20 and POUJ20 stay above it from 18-10 to the end, which is NEBRASKA-6.
- Against the night level before the cold morning (17-10 20:00 and 18-10 00:00, read in `work/corr_y.txt`, noise of the whole range), at 19-10 08:00: POUH20 corr_y +6.7 noises (+0.083 px, about 1.0 mm), POUJ19 corr_y +6.5 (+0.111 px, about 0.5 mm), COLJ19 corr_y +5.6 (about 0.23 mm).
- Against the daytime level of 18-10 (04:00 to 16:00; `scripts/thermal_dev.py`, `work/requal/n7_dev_preday.txt`): POUH21 corr_x +6.6, POUJ19 corr_y +6.0, POUH20 corr_y +5.6, COLJ19 corr_y +5.5.
- Against a level that brackets the event (18-10 16:00, 19-10 20:00 and 20-10 00:00), which also removes the drift underneath (`n7_dev_bracket.txt`): COLJ19 corr_y +5.0, COLH21 and POUH21 corr_x +4.9. This is at the threshold, because the curves come back a little higher than they left.
- `ranges.py --rolling 3`, `--rolling 6` and `--rolling 1d` flag nothing. The bump lasts about six measurements, as long as the rolling windows, so these windows absorb it. They do not measure this event.
- So the label holds, but only just. I keep it unchanged.
- **Images**: 19-10 00:00 and 08:00 (previous analysis). Indoor scene intact.
- **Confidence**: medium. The label is above the threshold against the levels before the event, and at the threshold against a level that brackets it.
## 2. What I left without a label
- **20-10 04:00 and 08:00**: a small dip of the top targets' corr_y (COLJ20 0.065 → 0.010 → 0.000 → 0.031) and a slight scale move (−39.7e-5). The temperature has a small trough here (31.0 °C at 06:00). days.py --bounds puts it under 5 noises on both the pose and the corr medians (scale −2.4, corr_y −2.9), so by the rule there is no thermal cycle to label. It sits under NEBRASKA-6. Note that the readings at 04:00 and 08:00 are identical on most sensors, and so is the pose.
- **17-10 08:00**: a small corr_x peak (COLJ20 0.466, POUH19 0.217) with a mild temperature dip (31.75 °C at 07:00). It is under NEBRASKA-5 and NEBRASKA-6, and below 5 noises.
- **17-10 00:00**: a one-measurement corr_y rise on COLH21, POUH21 and COLH20 (about 4 to 5 noises on COLH21 and COLH20). It falls inside NEBRASKA-3 and NEBRASKA-6, at the moment the camera turns from straightening to tilting again. POUH20 then stays up, which is the deformation NEBRASKA-6 describes. ranges.py --rolling 3 --instants 3 finds no instant in the range where three sensors deviate together.
- **18-10**: POUH20 corr_x steps up by a little (0.073 → 0.094) and stays. NEBRASKA-6 describes this explicitly (POUH20 rising fast with the tilt from 17 to 19 Oct).
- **error_value**: small slow drifts (COLH19 0.097 → 0.126) that do not affect the corr.
**No label was removed.** None of the four labels rests on missing points, and none is a camera movement that the compensation absorbs:
- NEBRASKA-3: up to 7.7 noises (COLJ20 corr_y). Kept.
- NEBRASKA-4: no measurement at all on the station. Kept.
- NEBRASKA-5: up to 10.5 noises (COLJ19 corr_x). Kept.
- NEBRASKA-7: up to 7.0 noises against the range level, and up to 6.7 against the night before (POUH20 corr_y); 5.0 against a bracketing level. Kept.
What the previous analysis left without a label is still below the threshold, and was not looked at again (no search for new events):
- 20-10 04:00–08:00: a small corr_y dip of the top targets, under 5 noises (median corr_y −2.9).
- 17-10 08:00: a small corr_x peak, below 5 noises.
- 17-10 00:00: a corr_y rise on COLH21 and COLH20, about 4 to 5 noises.
- 18-10: a small step of POUH20 corr_x. In `ranges.py --rolling 3` it reaches 5.3 and −5.4 noises at 18-10 04:00 and 16:00, single points inside the drift of the long label NEBRASKA-6, which describes POUH20 rising with the tilt.
## 3. The documentation
- `families.md` and `labeling-rules.md` were enough. Two rules settled the "nothing to add" calls: no thermal label below 5 noises, and a bump that is only the trace of a slow camera movement follows the cutting of that movement.
- `reading-rules.md` section 5 ("drift specific to a few targets that follows the camera… [NEBRASKA-6, NEBRASKA-5]") matches the data.
- `stations.md`: the NEBRASKA row is accurate.
- The rigid residual alone made COLJ19's y look specific on 17 Oct. Reading the raw y target by target showed the whole top group moving. On a scene that deforms, the similarity fitted on the median of the targets marks a group as a residual.
- The spanning labels: NEBRASKA-2 holds within the range. NEBRASKA-6 holds within the range (the drift from 17 Oct; corr_y down on COLH19, POUH19, POUJ20, and a little on COLJ19 and COLH20; up on POUH20 and COLH21; tilt rising fast until 19 Oct). Its description cites "ensemble.py --rigide", which is not the name of the tool (it is overview.py --rigid). This is a wording slip, not an error on the data.
- `labeling-rules.md` section 1 was clear on the threshold. One gap: for a thermal bump that lasts about one day at a 4 h cadence, `--rolling` (named for thermal cycles) absorbs the bump itself. The night level asked for by the rule had to be computed by hand from the per-instant tables. A `ranges.py` option for "level = the night before" (like `days.py --bounds`, but per target) would settle such cases directly. `days.py --bounds` works on the median of the targets, which hides a deviation carried by two or three targets (there: never above 3.7 noises).
- The full-range level of `ranges.py` without rolling is biased in corr_x by the long drift (NEBRASKA-6). It is usable in corr_y here, which has no drift.
- No precedent was looked up again: the families and the bounds are unchanged.
## Requalification
Commands (output in `work/requal/`):
- `python3 tools/scripts/ranges.py data/NEBRASKA --columns corr_x,corr_y --k 5 --start 2026-10-13T00:00Z --end 2026-10-22T00:00Z` → `full.txt`: at 19-10 08:00, POUH20 cy +7.0, COLH21 cx +6.5, POUJ19 cy +5.7, COLJ20 cx +5.2; the COLJ19 cx jump at 17-10 00:00 is 6.6 noises.
- `… --start 2026-10-10T00:00Z --end 2026-10-17T20:00Z --outside 2026-10-13T04:00Z/2026-10-17T04:00Z` → `n3_outside.txt`: NEBRASKA-3, COLJ20 cy +7.7, COLH19 cy +7.4, POUJ19 cy +6.7, POUH19 cy +6.4; NEBRASKA-5, COLJ19 cx +10.5 (17-10 00:00) to +6.5 (17-10 20:00).
- `… --start 2026-10-17T00:00Z --end 2026-10-21T00:00Z --rolling 1d --instants 2` → `n7_rolling1d.txt`: no range.
- `… --start 2026-10-13T00:00Z --end 2026-10-22T00:00Z --rolling 3|6 --instants 2` → `full_rolling3.txt`, `full_rolling6.txt`: only POUH20 cx ±5.3–5.4 on 18-10 (under NEBRASKA-6).
- `python3 scripts/thermal_dev.py <folder> <reference instants> <span>` → `n7_dev_preday.txt`, `n7_dev_bracket.txt`: NEBRASKA-7 per target, see section 1.
- `python3 tools/scripts/inventory.py data/NEBRASKA --start 2026-10-15T12:00Z --end 2026-10-16T16:00Z` → `n4_inventory.txt`: 3 instants missing for all the sensors.
| id | bounds | family | max deviation (noises) | decision |
|---|---|---|---|---|
| NEBRASKA-3 | 13-10 04:00 → 17-10 04:00 | Displacement | 7.7 (COLJ20 cy, level outside) | kept |
| NEBRASKA-4 | 15-10 20:00 → 16-10 12:00 | No data | no measurement at all | kept |
| NEBRASKA-5 | 16-10 20:00 → 17-10 20:00 | Displacement | 10.5 (COLJ19 cx, level outside) | kept |
| NEBRASKA-7 | 18-10 16:00 → 19-10 16:00 | Thermal displacement | 7.0 (POUH20 cy, range level); 6.7 vs the night before; 5.0 bracketing | kept |
`validate.py`: 0 errors. It reports 1 overlap to look at, NEBRASKA-3 with NEBRASKA-5. These are two distinct events (a camera bump of the top group, and COLJ19's own jump), and the overlap already existed.
## Difficulties
- none
- The prescribed `--rolling` cannot measure a one-day thermal bump at a 4 h cadence (see section 3). I used the night level by hand instead.
## Sources read
tools/GUIDE.md, tools/DATA.md, labeling/families.md, labeling/labeling-rules.md, labeling/reading-rules.md, labeling/stations.md, labeling/auto/NEBRASKA.jsonl, work/existing.jsonl, work/spanning.jsonl, instructions/analyst.md. Tools: inventory.py, overview.py (--rigid 2026-10-13T00:00Z), days.py --bounds, ranges.py --rolling, metrics.py (NEBRASKA, JUNGFRAU), stations.py (the building, then all stations on the gap), thumbnails.py --fixed, plot.py, precedents.py. Whole images 2026-10-13T08:00Z and 2026-10-19T08:00Z. My script scripts/table.py (per-instant tables of corr, x, y, error_value with the pose).
instructions/analyst.md; tools/GUIDE.md (ranges, days, the reading steps); labeling/labeling-rules.md (sections 1 to 5); the analysis folder: `work/requalify_input.jsonl`, `labels.jsonl`, `analysis.md` and `report.md` (previous versions, copied to `work/*.before-requalify.md`), `work/corr_x.txt`, `work/corr_y.txt`, `work/days.txt`. Tools: ranges.py (full range, outside, rolling 3, 6, 1d), inventory.py (distances, mm/px, the gap). Script: `scripts/thermal_dev.py`. `data/NEBRASKA/` listing (no `weather/`).
@@ -1,44 +1,42 @@
# NEBRASKA: check of the labels from 13 to 22 October
# NEBRASKA: labels from 13 to 22 October, rechecked under the new rule
You asked for a check of the four existing labels between 13 and 22 October (UTC): keep, correct, remove or add.
## Verification
Kept: 4. Corrected: 0. Removed: 0. Added: 0.
- NEBRASKA-3: kept. The bounds, the targets named, the camera movement and the link with the other two cameras of the building all match the data.
- NEBRASKA-4: kept. The gap starts at 23:00 on all nine stations that were measuring that night. The voltage is normal on both sides.
- NEBRASKA-5: kept. COLJ19 jumps alone at midnight on 17 October and is about half way back at 20:00.
- NEBRASKA-7: kept. The coldest morning so far brings the camera peak at 08:00 on 19 October, then it comes back.
- Long labels crossing the range: NEBRASKA-2 and NEBRASKA-6 hold within the range. One wording slip in NEBRASKA-6: it names a tool that does not exist ("ensemble.py --rigide"; the tool is the rigid view of overview.py). The data are right.
You asked to requalify the four labels of 13 to 22 October (UTC) under the new rule: label only what stands out from the noise of the corrected curves.
## In short
All four labels are right, and nothing is missing. From 13 October the curves can only be trusted with caution: one reference is lost and the camera tilts. No movement of the structure is established.
All four labels stay as they are, because each one stands out from the noise. From 13 October the curves should be trusted with caution: one reference is lost and the camera tilts. No movement of the structure is established.
## What happened
**The camera straightens, then tilts again (13 to 22 October).** From 13 to 16 October the camera stops nodding forward and straightens slightly. The corrected curves in y of the top targets (COLJ20, POUJ20, POUJ19, COLJ19) rise by a notch over these days, then drop back on 17 October. After that the camera tilts forward again, quickly until 19 October, and the corrected curves in x of all the targets drift up. Only two references remain, so the correction cannot follow the camera properly. The two other cameras of the building move on the same days. The camera movement is certain. Its cause is unknown.
**The camera straightens, then tilts again (13 to 17 October).** The camera stops nodding forward and straightens slightly. The corrected curves in y of the top targets (COLJ20, POUJ19, POUH19, COLH19) rise by about 0.3 to 0.4 mm. That is up to almost 8 times their usual noise. They drop back on 17 October. Only two references remain, so the correction cannot follow the camera properly. The two other cameras of the building move on the same days. The camera movement is confirmed, but its cause is unknown.
**A night without data (15 to 16 October).** Three measurements are missing, from 20:00 to 12:00. The same gap hits every station that was measuring. The likely cause is the transmission of the data, not the station.
**A night without data (15 to 16 October).** The station delivers nothing for three measurements, from 20:00 to 12:00. The same gap hits every station that was measuring. The likely cause is the transmission of the data, not the station.
**COLJ19 jumps alone (17 October).** At midnight its corrected curve in x jumps, while its neighbours do not. It is about half way back that evening. Nothing is seen on the image. The cause is unknown.
**COLJ19 jumps alone (17 October).** At midnight its corrected curve in x jumps by about 0.3 mm (COLJ19 is 11 m from the camera). That is about 10 times its noise. Its neighbours do not move. It is about half way back that evening. Nothing is seen on the image. The cause is unknown.
**Cold morning (19 October).** The housing temperature reaches its lowest so far. The camera nods forward most at 08:00, and the curves have a peak, then come back by 16:00. The cause, the cold acting on the camera, is likely.
**Cold morning (19 October).** The camera housing reaches its lowest temperature so far, and the camera nods forward most at 08:00. The corrected curves follow it. Compared with the night before, POUH20 (31 m away) rises by about 1 mm in y, and POUJ19 (12 m away) by about 0.5 mm, 6 to 7 times their noise. The curves are back by 16:00. The cold acting on the camera is the likely cause. This label clears the threshold, but only just: the curves come back a little higher than they left, because a slow tilt continues underneath.
![Corrected curves of the top targets](curves.png)
Grey bands, from left to right: the bump of 13 to 17 October, the night without data, the cold morning of 19 October. Look at the step in x of COLJ19 (red) on 17 October, and at the drift in x of all the targets after it.
Grey bands, from left to right: the bump of 13 to 17 October, the night without data, the cold morning of 19 October. Look at the step in x of COLJ19 (red) on 17 October.
## What to do
Nothing more than the long labels already say: restore the lost reference REFCOLH22 on site, and keep watching the camera tilt.
## Not established
The cause of COLJ19's jump on 17 October. Looking at the target on site, and following its curve, would settle it.
## Requalification
Kept: 4. Rewritten: 0. Removed: 0. There is no weather data for this station, which is indoors.
## Labels
| Start (UTC) | End (UTC) | Family | Targets | In a few words |
|---|---|---|---|---|
| 2026-10-13 04:00 | 2026-10-17 04:00 | Displacement | COLJ20, POUJ20, POUJ19, COLJ19 | The camera straightens; the curves in y of the top targets rise, then drop back (kept) |
| 2026-10-15 20:00 | 2026-10-16 12:00 | No data | all | Night gap common to all stations (kept) |
| 2026-10-16 20:00 | 2026-10-17 20:00 | Displacement | COLJ19 | Jump alone in x, half way back in the evening (kept) |
| 2026-10-18 16:00 | 2026-10-19 16:00 | Thermal displacement | POUJ19, COLJ20, POUH20, most targets in x | Cold morning, camera peak at 08:00 (kept) |
| 2026-10-13 04:00 | 2026-10-17 04:00 | Displacement | COLJ20, POUJ19, POUH19, COLH19 | The camera straightens; the curves in y of the top targets rise, then drop back |
| 2026-10-15 20:00 | 2026-10-16 12:00 | No data | all | Night gap common to all stations |
| 2026-10-16 20:00 | 2026-10-17 20:00 | Displacement | COLJ19 | Jumps alone in x, half way back in the evening |
| 2026-10-18 16:00 | 2026-10-19 16:00 | Thermal displacement | POUH20, POUJ19, COLJ19, most targets in x | Cold morning, camera peak at 08:00 |
@@ -0,0 +1,32 @@
"""Deviation of each target, in its own noise (ranges.py full-range noise),
from a reference level (median of chosen instants), over the instants of a label.
Reads the per-instant tables work/corr_x.txt, work/corr_y.txt written by table.py."""
import re, statistics, sys
D = sys.argv[1]
ref = sys.argv[2].split(',') # reference instants 'MM-DD HH:MM'
span = sys.argv[3].split('/') # 'MM-DD HH:MM/MM-DD HH:MM'
noise = {}
col = None
for line in open(f"{D}/work/requal/full.txt"):
if line.startswith('== corr_x'): col = 'corr_x'
elif line.startswith('== corr_y'): col = 'corr_y'
m = re.match(r'^(\S+)\s+52\s+\S+\s+(\S+)\s', line)
if col and m and not m.group(1).startswith('REF'):
noise[(col, m.group(1))] = float(m.group(2))
for c in ('corr_x', 'corr_y'):
rows = [l.rstrip('\n') for l in open(f"{D}/work/{c}.txt")]
head = rows[0].split()[1:13]
data = {}
for r in rows[1:]:
p = r.split()
if len(p) < 14: continue
t = p[0] + ' ' + p[1]
try: data[t] = [float(v) for v in p[2:14]]
except ValueError: pass
times = sorted(data)
sel = [t for t in times if span[0] <= t <= span[1]]
print(f"== {c} reference {ref}")
print('time ' + ' '.join(f"{h:>7}" for h in head))
lev = [statistics.median(data[t][i] for t in ref if t in data) for i in range(12)]
for t in sel:
print(t + ' ' + ' '.join(f"{(data[t][i]-lev[i])/noise[(c, head[i])]:7.1f}" for i in range(12)))