auto: labels requalified under the 5-noise rules (only what stands out from the noise): 32 analyses refined, the 6 paused periods verified, the long labels requalified with the fixes the period analysts found; 1153 -> 961 labels

- 32 analyses: each label kept, rewritten or removed by its analyst (section Requalification of the report; mm magnitudes where the targets have them)
- SNCF01 x3, WILDSTRUBEL 2026-09-01 -> 2026-10-06 x3: verified from their existing labels under the new rules
- long labels (no analysis): auto/analyses/long-labels/<STATION>/; NORDEND-169 and -195 run to 07/11, so NORDEND-283 and -284 (their continuation) are removed
- reading-rules.md, stations.md: the citations of removed or rewritten labels point to their successor, or to [expert]

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
maximeandClaude Opus 5.5 committed 2026-11-17 23:58:00 +01:00
1 parent c779de7720
commit ddb17c2189
321 files changed
+18464 -3426

No files matched your search

@@ -1,44 +1,42 @@
# NEBRASKA: check of the labels from 13 to 22 October
# NEBRASKA: labels from 13 to 22 October, rechecked under the new rule
You asked for a check of the four existing labels between 13 and 22 October (UTC): keep, correct, remove or add.
## Verification
Kept: 4. Corrected: 0. Removed: 0. Added: 0.
- NEBRASKA-3: kept. The bounds, the targets named, the camera movement and the link with the other two cameras of the building all match the data.
- NEBRASKA-4: kept. The gap starts at 23:00 on all nine stations that were measuring that night. The voltage is normal on both sides.
- NEBRASKA-5: kept. COLJ19 jumps alone at midnight on 17 October and is about half way back at 20:00.
- NEBRASKA-7: kept. The coldest morning so far brings the camera peak at 08:00 on 19 October, then it comes back.
- Long labels crossing the range: NEBRASKA-2 and NEBRASKA-6 hold within the range. One wording slip in NEBRASKA-6: it names a tool that does not exist ("ensemble.py --rigide"; the tool is the rigid view of overview.py). The data are right.
You asked to requalify the four labels of 13 to 22 October (UTC) under the new rule: label only what stands out from the noise of the corrected curves.
## In short
All four labels are right, and nothing is missing. From 13 October the curves can only be trusted with caution: one reference is lost and the camera tilts. No movement of the structure is established.
All four labels stay as they are, because each one stands out from the noise. From 13 October the curves should be trusted with caution: one reference is lost and the camera tilts. No movement of the structure is established.
## What happened
**The camera straightens, then tilts again (13 to 22 October).** From 13 to 16 October the camera stops nodding forward and straightens slightly. The corrected curves in y of the top targets (COLJ20, POUJ20, POUJ19, COLJ19) rise by a notch over these days, then drop back on 17 October. After that the camera tilts forward again, quickly until 19 October, and the corrected curves in x of all the targets drift up. Only two references remain, so the correction cannot follow the camera properly. The two other cameras of the building move on the same days. The camera movement is certain. Its cause is unknown.
**The camera straightens, then tilts again (13 to 17 October).** The camera stops nodding forward and straightens slightly. The corrected curves in y of the top targets (COLJ20, POUJ19, POUH19, COLH19) rise by about 0.3 to 0.4 mm. That is up to almost 8 times their usual noise. They drop back on 17 October. Only two references remain, so the correction cannot follow the camera properly. The two other cameras of the building move on the same days. The camera movement is confirmed, but its cause is unknown.
**A night without data (15 to 16 October).** Three measurements are missing, from 20:00 to 12:00. The same gap hits every station that was measuring. The likely cause is the transmission of the data, not the station.
**A night without data (15 to 16 October).** The station delivers nothing for three measurements, from 20:00 to 12:00. The same gap hits every station that was measuring. The likely cause is the transmission of the data, not the station.
**COLJ19 jumps alone (17 October).** At midnight its corrected curve in x jumps, while its neighbours do not. It is about half way back that evening. Nothing is seen on the image. The cause is unknown.
**COLJ19 jumps alone (17 October).** At midnight its corrected curve in x jumps by about 0.3 mm (COLJ19 is 11 m from the camera). That is about 10 times its noise. Its neighbours do not move. It is about half way back that evening. Nothing is seen on the image. The cause is unknown.
**Cold morning (19 October).** The housing temperature reaches its lowest so far. The camera nods forward most at 08:00, and the curves have a peak, then come back by 16:00. The cause, the cold acting on the camera, is likely.
**Cold morning (19 October).** The camera housing reaches its lowest temperature so far, and the camera nods forward most at 08:00. The corrected curves follow it. Compared with the night before, POUH20 (31 m away) rises by about 1 mm in y, and POUJ19 (12 m away) by about 0.5 mm, 6 to 7 times their noise. The curves are back by 16:00. The cold acting on the camera is the likely cause. This label clears the threshold, but only just: the curves come back a little higher than they left, because a slow tilt continues underneath.
![Corrected curves of the top targets](curves.png)
Grey bands, from left to right: the bump of 13 to 17 October, the night without data, the cold morning of 19 October. Look at the step in x of COLJ19 (red) on 17 October, and at the drift in x of all the targets after it.
Grey bands, from left to right: the bump of 13 to 17 October, the night without data, the cold morning of 19 October. Look at the step in x of COLJ19 (red) on 17 October.
## What to do
Nothing more than the long labels already say: restore the lost reference REFCOLH22 on site, and keep watching the camera tilt.
## Not established
The cause of COLJ19's jump on 17 October. Looking at the target on site, and following its curve, would settle it.
## Requalification
Kept: 4. Rewritten: 0. Removed: 0. There is no weather data for this station, which is indoors.
## Labels
| Start (UTC) | End (UTC) | Family | Targets | In a few words |
|---|---|---|---|---|
| 2026-10-13 04:00 | 2026-10-17 04:00 | Displacement | COLJ20, POUJ20, POUJ19, COLJ19 | The camera straightens; the curves in y of the top targets rise, then drop back (kept) |
| 2026-10-15 20:00 | 2026-10-16 12:00 | No data | all | Night gap common to all stations (kept) |
| 2026-10-16 20:00 | 2026-10-17 20:00 | Displacement | COLJ19 | Jump alone in x, half way back in the evening (kept) |
| 2026-10-18 16:00 | 2026-10-19 16:00 | Thermal displacement | POUJ19, COLJ20, POUH20, most targets in x | Cold morning, camera peak at 08:00 (kept) |
| 2026-10-13 04:00 | 2026-10-17 04:00 | Displacement | COLJ20, POUJ19, POUH19, COLH19 | The camera straightens; the curves in y of the top targets rise, then drop back |
| 2026-10-15 20:00 | 2026-10-16 12:00 | No data | all | Night gap common to all stations |
| 2026-10-16 20:00 | 2026-10-17 20:00 | Displacement | COLJ19 | Jumps alone in x, half way back in the evening |
| 2026-10-18 16:00 | 2026-10-19 16:00 | Thermal displacement | POUH20, POUJ19, COLJ19, most targets in x | Cold morning, camera peak at 08:00 |