{"id": "MICHIGAN-1", "start": "2026-10-03T00:00Z", "end": "2026-10-05T16:00Z", "family": "Target issue", "description": "From the start of the data to 5 October at noon, COLH21' and REFH22' give exactly the same positions, the same error_value and the same corrected curves: the two sensors are placed on the same point of a group of spots, and their corr_y is clearly lower than that of their neighbors. At the 16:00 measurement on 5 October, they separate: on the 12:00 and 16:00 thumbnails, the scene is the same, but COLH21' is now centered on the top of the group and REFH22' on the bottom; their corr_y jumps toward that of their neighbors and stays there, their error_value drops. At the same moment, the raw positions of several other targets, including COLH18', change a little without their corrected curves moving, and the camera does not move. Cause deduced, not established: the sensors were reconfigured, and COLH21' and REFH22' were badly configured before, placed on the same point; the jump at 16:00 is the return to normal. For the customer: this is not a movement of the structure; the curves of COLH21' and REFH22' from before 5 October at 16:00 are not to be trusted and cannot be compared with those after; check that the current configuration of these two targets is the right one.", "review": "2026-11-04"} {"id": "MICHIGAN-2", "start": "2026-10-06T00:00Z", "end": "2026-10-06T08:00Z", "family": "Thermal displacement", "description": "For the duration of one measurement, on 6 October at 04:00, the corr_y of most targets goes down together, a little, then returns at the next measurement. At the same moment, the camera housing temperature makes a brief drop, at the end of the night, the camera nods forward slightly (tilt rising, scale dropping) and the raw positions of all the sensors, references included, slide together: it is the camera that moves, not the targets; the compensation, still on three references, does not erase all of this movement. Cause deduced from the curves and the camera housing temperature; nothing in front of the targets on the 04:00 image. Small deviation. For the customer: this is not a movement of the structure, nothing to do.", "review": "2026-11-04"} {"id": "MICHIGAN-3", "start": "2026-10-09T08:00Z", "end": "2026-11-01T00:00Z", "family": "Target issue", "description": "The reference REFPOU22 is lost on 9 October between the 08:00 measurement and the 12:00 one, and does not come back until the end of the month: its error_value rises almost to the maximum, it is rejected at every measurement and its raw positions wander far from its place. On the thumbnails, its spot, sharp at 04:00 and 08:00 on 9 October, has disappeared at 12:00 and does not come back (also seen on 12 October, 20 October and 31 October), while the neighboring spots and REF42, REFG43N are intact; no obstacle is visible. At 12:00 on 9 October, corr_x and corr_y of all the targets jump together and stay shifted, without a step in the raw positions: the compensation now only runs on REF42 and REFG43N, its reprojection error drops to zero and the basis changes. With these two references only, close to each other and far from the targets, the compensation is fragile: the curves of all the targets are more agitated than before, and the slightest deviation of these two references relative to the targets passes, amplified, into all the targets. At the same measurement, NEBRASKA, in the same building as MICHIGAN according to the expert, also loses one of its references (REFCOLH22), whose spot disappears in the same way with no visible obstacle: a cause common to both, in the building, is to be looked for; it is not established. The reference of the same name seen by BREITHORN stays sharp on its images. Cause of the loss not established (prism masked, turned or removed). For the customer: the jump is not a movement, and the corrected curves since 9 October are not very reliable; check the prism of REFPOU22 on site and restore it.", "review": "2026-11-04"} {"id": "MICHIGAN-4", "start": "2026-10-09T12:00Z", "end": "2026-10-12T16:00Z", "family": "Displacement", "description": "From 9 to 12 October, the camera gradually nods forward, rotates and its scale drops; all the targets slide together in the image, without moving relative to each other. With three references, until 9 October, this movement was compensated; since the loss of REFPOU22 (separate label), the corr_x of all the targets rises slowly. The compensation on REF42 and REFG43N alone, since the loss of REFPOU22, passes this movement into all the targets. Deduced from the curves and the camera pose; nothing on the images. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of the three stations tilt together, in the same direction and on the same dates (advance until 12 October, stop and slight backward movement from 13 to 16, resumption from the 17th to the end of the month), which points to a cause common to the building rather than a fault of this camera alone; at equal housing temperature, the cameras are more tilted at the end of the month than in the middle: temperature does not explain it alone, link not established. For the customer: the targets do not move relative to each other, this is not a movement of the structure; the camera tilt is to be monitored, and restoring a third reference will make the curves reliable again.", "review": "2026-11-04"} {"id": "MICHIGAN-5", "start": "2026-10-12T16:00Z", "end": "2026-10-16T16:00Z", "family": "Displacement", "description": "From the evening of 12 October to 16 October, the corr_x of all the targets goes back down together, lowest on 15 October at the end of the day, then goes up again: the camera stops nodding forward and straightens a little. The compensation on REF42 and REFG43N alone, since the loss of REFPOU22, passes this movement into all the targets. Deduced from the curves and the camera pose; nothing on the images. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of BREITHORN and NEBRASKA stop and move back on the same days, when the housing temperature stops dropping, link not established. For the customer: the targets do not move relative to each other, this is not a movement of the structure; the camera tilt is to be monitored, and restoring a third reference will make the curves reliable again.", "review": "2026-11-04"} {"id": "MICHIGAN-6", "start": "2026-10-15T20:00Z", "end": "2026-10-16T12:00Z", "family": "No data", "description": "No measurement for any sensor in the night of 15 to 16 October: three measurements are missing, all the curves are cut, then everything resumes at the same level. The station metrics are also missing over these hours (temperatures, voltage, synchronization); the voltage is normal just before and just after, the battery full: no sign of a power cut. The same gap affects the two other stations of the building (BREITHORN, NEBRASKA, in the same building according to the expert), but also all the other stations. The gap starts at the same time, around 23:00, on the nine stations that were measuring then (LENZSPITZE only has its first measurements in the middle of that night, WILDSTRUBEL is already stopped), and their metrics stop at the same time on most of them; measurements and metrics resume at different times depending on the station, most of them in late morning. JUNGFRAU, whose metrics continue, accumulates unsent entries all night, sent in late morning, and yet its measurements for the night are missing from the data: a common cause outside the stations (transmission or reception of the data), not a shutdown of the stations; it is not established. The cause is therefore not specific to the building. The curves are missing over the range; nothing to do on the station if it does not repeat.", "review": "2026-11-04"} {"id": "MICHIGAN-7", "start": "2026-10-16T12:00Z", "end": "2026-11-01T00:00Z", "family": "Displacement", "description": "From 16 October to the end of the month, the camera nods forward again, rotates and its scale drops, faster from 17 October with the drop in the camera housing temperature; all the targets slide together in the image, without moving relative to each other. The corr_x of all the targets rises by a step on 17 and 18 October and stays high until the 28th; after the cold mornings of 29 and 30 October, it ends up lower and stays there until the end of the month; the corr_y of all the targets goes down slowly over the whole range. The compensation on REF42 and REFG43N alone, since the loss of REFPOU22, passes this movement into all the targets. Deduced from the curves and the camera pose; nothing on the images. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of the three stations tilt together, in the same direction and on the same dates (advance until 12 October, stop and slight backward movement from 13 to 16, resumption from the 17th to the end of the month), which points to a cause common to the building rather than a fault of this camera alone; at equal housing temperature, the cameras are more tilted at the end of the month than in the middle: temperature does not explain it alone, link not established. The station is in a factory, indoors, according to the expert: it is not a day/night cycle. For the customer: the targets do not move relative to each other, this is not a movement of the structure; the camera tilt is to be monitored, and restoring a third reference will make the curves reliable again.", "review": "2026-11-04"} {"id": "MICHIGAN-8", "start": "2026-10-17T12:00Z", "end": "2026-10-18T08:00Z", "family": "Displacement", "description": "All the targets become agitated together for three measurements: the corr_x goes down at 16:00 on 17 October, the corr_y plunges at 20:00, then corr_x and corr_y rise above their level on 18 October at 04:00, and everything returns. The camera pose computed on REF42 and REFG43N swings back and forth (tilt, rotation) without the raw positions of the targets moving clearly, and the gap between the two references changes a little: it is the two-reference compensation that carries this gap over to all the targets. The temperatures then drop in steps, but without a brief variation at the time of these deviations. Cause not established, nothing on the images. For the customer: this is not a movement of the structure, the points of this range are to be ignored.", "review": "2026-11-04"} {"id": "MICHIGAN-9", "start": "2026-10-19T00:00Z", "end": "2026-10-19T12:00Z", "family": "Thermal displacement", "description": "On 19 October in the morning, the corr_y of all the targets plunges together for two measurements, the corr_x too at the second, then everything returns at noon. The camera housing temperature makes a brief drop at the same moment, at the end of the night, and the camera moves: it nods forward, rotates, its scale drops, the raw positions of all the targets and of the two references slide almost together; the targets do not move relative to each other. The compensation on two references only, REF42 and REFG43N, carries their small gap relative to the targets over to all the targets. The first affected measurement slightly precedes the temperature drop. Cause deduced from the curves and the camera housing temperature; nothing in front of the targets on the 08:00 image. For the customer: this is not a movement of the structure, nothing to do.", "review": "2026-11-04"} {"id": "MICHIGAN-10", "start": "2026-10-23T20:00Z", "end": "2026-10-24T20:00Z", "family": "Thermal displacement", "description": "The corr_y of all the targets goes down together on 24 October at midnight, partly rises again in the morning, stays low in the afternoon and returns in the evening; their corr_x stays slightly lower over the whole range. The camera housing temperature drops at the same moment and stays low until evening; the camera nods forward and the raw positions of all the targets and of the two references slide almost together, the targets do not move relative to each other. The compensation on REF42 and REFG43N alone carries their small gap relative to the targets over to all the targets. Cause deduced from the curves and the camera housing temperature, not a day/night cycle; nothing in front of the targets on the midnight image. Small deviation. For the customer: this is not a movement of the structure, nothing to do.", "review": "2026-11-04"} {"id": "MICHIGAN-11", "start": "2026-10-25T16:00Z", "end": "2026-10-26T16:00Z", "family": "Thermal displacement", "description": "The corr_y of all the targets goes down together from the evening of 25 October until the morning of the 26th, the corr_x goes down in turn on the morning of the 26th, then everything returns in the afternoon. The camera housing temperature drops at the same moment and rises again on the afternoon of the 26th; the camera nods forward, its scale drops, the raw positions of all the targets and of the two references slide almost together, the targets do not move relative to each other. The compensation on REF42 and REFG43N alone carries their small gap relative to the targets over to all the targets. Cause deduced from the curves and the camera housing temperature; nothing in front of the targets on the 04:00 image on the 26th. For the customer: this is not a movement of the structure, nothing to do.", "review": "2026-11-04"} {"id": "MICHIGAN-12", "start": "2026-10-26T20:00Z", "end": "2026-10-27T20:00Z", "family": "Displacement", "description": "On 27 October, the corr_y of all the targets rises together above its level, mostly at night and in the morning, then goes back down in the evening; the corr_x hardly moves. The camera pose computed on REF42 and REFG43N swings (tilt dropping clearly) without the raw positions of the targets moving: it is the two references that move slightly away from the targets, and the compensation on them alone carries this gap over to all the targets. The component temperatures show neither a dip nor a clear bump, and according to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of BREITHORN and NEBRASKA do not move that day. Cause not established, like the agitation of 17 and 18 October; nothing on the images. For the customer: this is not a movement of the structure, the points of this range are to be ignored.", "review": "2026-11-04"} {"id": "MICHIGAN-13", "start": "2026-10-28T00:00Z", "end": "2026-10-28T16:00Z", "family": "Thermal displacement", "description": "On 28 October in the morning, the corr_x of all the targets goes down a little at 04:00 and plunges at 08:00, the corr_y too, then the corr_x returns at noon and the corr_y at the next measurement. The camera housing temperature drops sharply at the same moment, at the end of the night, and rises again in late morning; the camera nods forward, its scale drops, the raw positions of all the targets and of the two references slide almost together, the targets do not move relative to each other. The compensation on REF42 and REFG43N alone carries their small gap relative to the targets over to all the targets. Cause deduced from the curves and the camera housing temperature; nothing in front of the targets on the 08:00 image. For the customer: this is not a movement of the structure, nothing to do; the point is to be ignored.", "review": "2026-11-04"} {"id": "MICHIGAN-14", "start": "2026-10-28T16:00Z", "end": "2026-10-29T16:00Z", "family": "Thermal displacement", "description": "From the evening of 28 October to the morning of 29 October, the corr_x of all the targets goes down clearly, together, with the corr_y, then rises all at once at the noon measurement, but stays clearly under its previous level, and does not regain it until the end of the month; the corr_y, partly returned at noon, only returns at the next measurement. The camera housing temperature makes the strongest drop of the month at the same time and rises all at once in late morning of the 29th; the camera nods forward clearly and its scale drops, the raw positions of all the targets slide together, without moving relative to each other, and REFG43N moves slightly away from their movement; the error_value of a few targets rises, far from the threshold. The compensation on REF42 and REFG43N alone carries over and amplifies this gap on all the targets. Cause deduced from the curves and the camera housing temperature; nothing in front of the targets on the 08:00 image. For the customer: this is not a movement of the structure, nothing to do; the curves of this range are not to be trusted.", "review": "2026-11-04"} {"id": "MICHIGAN-15", "start": "2026-10-29T16:00Z", "end": "2026-10-30T12:00Z", "family": "Thermal displacement", "description": "From the evening of 29 October to the morning of 30 October, the corr_y of all the targets already goes down a little at 20:00, then the corr_x goes back down clearly, together, with the corr_y touching its lowest in late morning, then everything rises again at noon. As the day before, the camera housing temperature drops at the same moment and rises again on the morning of the 30th; the camera nods forward and its scale drops, the raw positions of all the targets slide together, without moving relative to each other, and REFG43N moves slightly away from their movement; the error_value of a few targets rises, far from the threshold. The compensation on REF42 and REFG43N alone carries over and amplifies this gap on all the targets. Cause deduced from the curves and the camera housing temperature; nothing in front of the targets on the 04:00 image. For the customer: this is not a movement of the structure, nothing to do; the curves of this range are not to be trusted.", "review": "2026-11-04"}