# The stations What each station is: its structure, its camera, its references, its neighbours. Context for reading a station's data, not a rule: what happens at a station is in its labels (`auto/.jsonl`, `precedents.py`). The kind of structure says whether a thermal movement of the structure is possible (`reading-rules.md`, section 3). Cases are cited by label id; `[expert]`: the expert's word. Maintained by hand: a new station gets its row when its first range is analysed. | Station | Structure | Camera | References | Neighbouring cameras | |---|---|---|---|---| | BREITHORN | in a building (a factory, indoors) [expert] | one measurement every four hours; COLJ19 and POUI19 much closer to the camera than the other targets [expert]; the camera nods forward over October, compensation incomplete [expert] | REFH22, REFPOU22 among the sensors at the bottom of the image | MICHIGAN and NEBRASKA, in the same building: a drift common to the three [BREITHORN-2] | | CLARIDEN | a tunnel under construction, with other measurement systems [expert] | images always dark; on mains | four references, D-302-C, PR-291, PR-293, PR-295; PR-284 is a local reference, read as a target; D-302-B and PR_BG on the same prism [CLARIDEN-38] | — | | FLORIDA | — | — | two references only, p1_r and r1_r, each with its twin target (Sellette 3, Pont Ernen) [expert] | its one-measurement gaps at night fall at the same instants as SNCF01's | | JUNGFRAU | a bridge, which rises as it cools [expert] | under the deck, fixed to the bridge | three references off the bridge, REF_D, REF_G, REF_CT | — | | LENZSPITZE | a railway seen from under a bridge, a work site and machines next to it | recent camera, with image quality; `x`, `y` relative in the export (`tools/DATA.md`); only `temperature_deg_c` is filled | nine references, including the distant 8011 to 8014 | — | | MICHIGAN | in the same building as BREITHORN, indoors [expert] | one measurement every four hours | two references since the loss of REFPOU22 on 09.10 [MICHIGAN-3]; COLH21' and REFH22' on the same point until 05.10 [MICHIGAN-1] | BREITHORN, NEBRASKA: lost a reference at the same measurement as NEBRASKA | | NEBRASKA | in the same building as BREITHORN [expert] | one measurement every four hours | two references since the loss of REFCOLH22 [NEBRASKA-2] | BREITHORN, MICHIGAN | | NIEDERHORN | railway tracks | floodlight at night | higher up, on the road above the tracks (PWD_REF08 to PWD_REF12) | — | | NORDEND | a quarry: a rock face too massive to move with the temperature [expert] | infrared lighting at night; DIFF images | three references, CTR02, CTR03, CTR04; CTR01 is a local reference, read as a target | — | | SNCF01 | a masonry wall along railway tracks | no system metrics, hence no temperature | three references, BG.3.1, R1, R2 | FLORIDA (gaps at the same instants) | | WILDSTRUBEL | a road, in a town [WILDSTRUBEL-102] | solar battery | six references, R1 and R2 at the edge of the road; R3 invisible by day [WILDSTRUBEL-130] | — |