{"id": "FLORIDA-1", "start": "2026-10-01T00:00Z", "end": "2026-11-01T00:00Z", "family": "Target issue", "description": "Sellette 6 is a constantly problematic target: its error_value stays just above the threshold, a large part of its measurements are rejected all month, day and night, whatever the weather: its curve has gaps every day and its kept measurements jump. Seen on the thumbnails: a very small spot, almost invisible by day, very close to the halo of Sellette 5, which is much brighter; on the morning of the 20th, the measurement of Sellette 5 even latched onto the spot of Sellette 6. Ignore its curve; check the orientation or cleanliness of the prism.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-01T0000_2026-11-01T0000"} {"id": "FLORIDA-14", "start": "2026-10-06T10:15Z", "end": "2026-11-01T00:00Z", "family": "Target issue", "description": "Massif 2 becomes a problematic target: by day, its spot is only a point (noon thumbnails of the 3rd and the 6th), and from the 6th its error_value goes above the threshold at times, measurements rejected by day; from the rain episode of the 8th, its spot also weakens at night and does not come back, the majority of its measurements are rejected day and night until the 29th, and its kept measurements change level (corr_y clearly going downward, corr_x going down at the end of the month). On the 30th and 31st, it is kept again, but just under the threshold and with a corr_y much lower than at the start of the month. Seen on the thumbnails: wide and bright spot at night in early October, small and weak afterwards, invisible by day on the 12th, 30th and 31st. Cause not established (prism tarnished, dirty or veiled). Ignore its curve; check the prism.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-01T0000_2026-11-01T0000"} {"id": "FLORIDA-46", "start": "2026-10-22T03:15Z", "end": "2026-10-22T03:45Z", "family": "Displacement", "description": "The corr_x of Sellette 4 alone jumps slightly upward from one measurement to the next, on the night of the 22nd at 3h30, and stays there until the end of the month; at the same moment its error_value goes down a little and stays lower. Sellette 5, its neighbors and the two references show nothing, the camera does not move and nothing hides it at that hour (no other episode). Its level joins the one it had from the 9th to the 15th. The housing temperature drops clearly on those days, as from the 9th to the 15th, but the jump happens from one measurement to the next, with a step in its error_value: link not established. Cause not established: the spot of Sellette 4 may have changed appearance, or the target may have moved. Small, without established movement of the structure: to be monitored.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-22T0315_2026-11-01T0000"} {"id": "FLORIDA-48", "start": "2026-10-22T11:15Z", "end": "2026-10-22T13:30Z", "family": "Visibility", "description": "r1_r, one of the only two references of the station, sees its error_value rise above the threshold in late morning, one measurement then four: it is rejected and the camera is no longer registered. The corrected curves are then computed on p1_r alone: the corr_x of Sellette 5 and Sellette 4 jump a little and return at the next registration. Pont Ernen, the twin of r1_r, leaves its usual zero when it is not rejected too. Raw positions of the targets without a step. Cause not established; r1_r is a tiny spot, day and night. With a single reference, no measurement is possible: data of the range not to be trusted; this is not a movement. If it repeats, check the prism r1_r.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-22T0315_2026-11-01T0000"} {"id": "FLORIDA-49", "start": "2026-10-23T03:45Z", "end": "2026-10-23T09:15Z", "family": "Visibility", "description": "r1_r, one of the only two references of the station, sees its error_value rise above the threshold at the end of the night then all morning, after a slow rise of its error_value in the night: it is rejected and the camera is no longer registered. The corrected curves are then computed on p1_r alone: the corr_x of Sellette 5 and Sellette 4 jump a little and return at the next registration. Pont Ernen, the twin of r1_r, leaves its usual zero when it is not rejected too. Raw positions of the targets without a step. Cause not established (dampness on the prism or morning light, without proof); r1_r is a tiny spot, day and night. With a single reference, no measurement is possible: data of the range not to be trusted; this is not a movement. If it repeats, check the prism r1_r.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-22T0315_2026-11-01T0000"} {"id": "FLORIDA-50", "start": "2026-10-23T12:15Z", "end": "2026-10-23T20:15Z", "family": "Visibility", "description": "Mist in the afternoon: the error_value of p1_r rises and the camera pose goes wrong, the corr_x of Sellette 4, Sellette 5 and Sellette 6 jumps clearly; then r1_r (with Pont Ernen), p1_r (with Sellette 3), Sellette 4 and Sellette 5 are rejected at times until the evening, the camera is often no longer registered. Seen on the 15:00 image: mist over the valley, milky scene. Back in the evening. Not a movement: curves of the range to ignore.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-22T0315_2026-11-01T0000"} {"id": "FLORIDA-51", "start": "2026-10-23T22:00Z", "end": "2026-10-24T01:45Z", "family": "Visibility", "description": "At night, the error_value of the two references, p1_r and r1_r, rises without exceeding the threshold: the camera pose goes wrong (mostly the tilt) and the corr of Sellette 4 and Sellette 5 shifts (corr_x upward, corr_y downward, clearly on Sellette 4), then returns around 1h30 when p1_r becomes sharp again. Thumbnails of 21:00, 23:00, 00:30 and 03:00: nothing in front of the spots, that of r1_r, tiny, getting weaker and weaker; r1_r stays poorly seen until its loss in the morning. Cause not established (dampness probable, like the neighboring episodes). Not a movement: curves of the range to ignore.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-22T0315_2026-11-01T0000"} {"id": "FLORIDA-53", "start": "2026-10-24T07:00Z", "end": "2026-10-24T14:45Z", "family": "Visibility", "description": "r1_r, one of the only two references of the station, sees its error_value rise above the threshold all morning and the early afternoon: it is rejected and the camera is no longer registered. The corrected curves are then computed on p1_r alone: the corr_x of Sellette 5 and Sellette 4 jump a little and return at the next registration. Pont Ernen, the twin of r1_r, leaves its usual zero when it is not rejected too. Raw positions of the targets without a step. Cause not established (dampness on the prism or morning light, without proof); r1_r is a tiny spot, day and night. With a single reference, no measurement is possible: data of the range not to be trusted; this is not a movement. If it repeats, check the prism r1_r.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-22T0315_2026-11-01T0000"} {"id": "FLORIDA-54", "start": "2026-10-24T21:45Z", "end": "2026-10-25T21:15Z", "family": "Visibility", "description": "Rain on the night of the 24th to the 25th and during the day of the 25th: the error_value of all the sensors rises very high; r1_r (with Pont Ernen) is rejected almost throughout the episode, p1_r (with Sellette 3) at night, Sellette 4, Sellette 5, Massif 2 and Sellette 6 almost always: the camera is almost no longer registered, almost all the curves are missing, and the kept measurements jump (clearly on Sellette 4 in late morning). Seen on the 03:00 image: drops lit by the infrared in front of the lens, a single visible spot. Back on the evening of the 25th, Sellette 4 the last, an hour after the others. Not a movement: curves of the range to ignore.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-22T0315_2026-11-01T0000"} {"id": "FLORIDA-55", "start": "2026-10-26T08:30Z", "end": "2026-10-26T12:00Z", "family": "Visibility", "description": "r1_r, one of the only two references of the station, sees its error_value rise above the threshold in the morning, after a slow rise of its error_value all night: it is rejected and the camera is no longer registered. The corrected curves are then computed on p1_r alone: the corr_x of Sellette 5 and Sellette 4 jump a little and return at the next registration. Pont Ernen, the twin of r1_r, leaves its usual zero when it is not rejected too. Raw positions of the targets without a step. Cause not established (dampness on the prism or morning light, without proof); r1_r is a tiny spot, day and night. With a single reference, no measurement is possible: data of the range not to be trusted; this is not a movement. If it repeats, check the prism r1_r.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-22T0315_2026-11-01T0000"} {"id": "FLORIDA-56", "start": "2026-10-26T11:45Z", "end": "2026-10-26T19:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_y of Sellette 5 rises during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-22T0315_2026-11-01T0000"} {"id": "FLORIDA-57", "start": "2026-10-26T14:30Z", "end": "2026-10-26T15:15Z", "family": "No data", "description": "Two measurements absent for all sensors, and no image; normal voltage around them. The same gap falls at the same moment on the other stations measuring at that time (CLARIDEN, JUNGFRAU, LENZSPITZE, NIEDERHORN, NORDEND, SNCF01), and their metrics are also missing at the same minutes: a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station. The hourly metrics of BREITHORN, MICHIGAN and NEBRASKA are also missing at 15:00.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-22T0315_2026-11-01T0000"} {"id": "FLORIDA-58", "start": "2026-10-27T01:45Z", "end": "2026-10-27T11:45Z", "family": "Visibility", "description": "r1_r, one of the only two references of the station, sees its error_value rise slowly from the evening of the 26th, then pass above the threshold in the morning. During the night, its position in the image slides relative to the targets (ensemble.py --rigide) and distorts the camera pose, while the housing temperature stays stable: this is not the return of the thermal cycle of the 26th; from 02:00, the corr_x of Sellette 4 and Sellette 5 deviates at times, and their corr_y at 05:00. In the morning, r1_r is rejected and the camera is no longer registered. The corrected curves are then computed on p1_r alone: the corr_x of Sellette 6, Sellette 5 and Sellette 4 jump a little and return at the next registration. Pont Ernen, the twin of r1_r, leaves its usual zero when it is not rejected too. Raw positions of the targets without a step. One measurement is missing for all sensors at 09:15. Seen on the thumbnails: the spot of r1_r weakens in the night, disappears at 08:00 and 10:00 and returns in the afternoon; no obstacle; dampness on the prism or morning light, cause not established. With a single reference, no measurement is possible: data of the range not to be trusted; this is not a movement. If it repeats, check the prism r1_r.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-22T0315_2026-11-01T0000"} {"id": "FLORIDA-59", "start": "2026-10-27T09:00Z", "end": "2026-10-27T09:30Z", "family": "No data", "description": "One measurement absent for all sensors; normal voltage around it. The same gap falls at the same moment on the other stations measuring at that time (CLARIDEN, JUNGFRAU, LENZSPITZE, NORDEND): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-22T0315_2026-11-01T0000"} {"id": "FLORIDA-60", "start": "2026-10-27T11:30Z", "end": "2026-10-27T20:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 6 goes down clearly in the afternoon, that of Sellette 5 a little, the corr_y of Sellette 5 rises a little, and everything returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-22T0315_2026-11-01T0000"} {"id": "FLORIDA-61", "start": "2026-10-28T07:00Z", "end": "2026-10-28T10:30Z", "family": "Visibility", "description": "r1_r, one of the only two references of the station, sees its error_value rise above the threshold in the morning, one measurement then nine, after a slow rise of its error_value all night: it is rejected and the camera is no longer registered. The corrected curves are then computed on p1_r alone: the corr_x of Sellette 5 and Sellette 4 (and of Sellette 6 at the first loss) jump a little and return at the next registration. Pont Ernen, the twin of r1_r, leaves its usual zero when it is not rejected too. Raw positions of the targets without a step. Same scenario as the previous mornings; cause not established. With a single reference, no measurement is possible: data of the range not to be trusted; this is not a movement. If it repeats, check the prism r1_r.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-22T0315_2026-11-01T0000"} {"id": "FLORIDA-79", "start": "2026-10-28T10:15Z", "end": "2026-10-28T19:45Z", "family": "Thermal displacement", "description": "Thermal cycle of the day, small: with the clear rise of the housing temperature in the morning, the camera pose turns (mostly the rotation, the tilt a little, the pan hardly moves) until the early afternoon, then returns in the late afternoon; the corr_y of Sellette 5 rises during the day and comes back toward its night level in the evening, the corr_x of Sellette 5 and Sellette 4 rise a little with it. The start is hidden under the loss of r1_r of the morning (separate label); the pose has already turned at the first registration after it. Deduced: the pose and the curves follow the housing temperature and come back with it, error_value at its level, the references calm. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-18", "analysis": "FLORIDA_2026-10-22T0315_2026-11-01T0000"} {"id": "FLORIDA-62", "start": "2026-10-29T06:45Z", "end": "2026-10-29T18:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_y of Sellette 5 rises during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-22T0315_2026-11-01T0000"} {"id": "FLORIDA-63", "start": "2026-10-30T07:45Z", "end": "2026-10-30T19:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_y of Sellette 5 rises during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-22T0315_2026-11-01T0000"} {"id": "FLORIDA-64", "start": "2026-10-31T06:45Z", "end": "2026-10-31T19:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_y of Sellette 5 rises during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-22T0315_2026-11-01T0000"} {"id": "FLORIDA-23", "start": "2026-10-11T09:45Z", "end": "2026-10-11T10:15Z", "family": "Visibility", "description": "r1_r, one of the only two references of the station, sees its error_value rise above the threshold for the duration of one measurement, in the morning: it is rejected and the camera is no longer registered. The corrected curves are then computed on p1_r alone: the corr_x of Sellette 5 and Sellette 4 jump a little and return at the next registration. Pont Ernen, the twin of r1_r, leaves its usual zero when it is not rejected too. Raw positions of the targets without a step. Cause not established. With a single reference, no measurement is possible: data of the range not to be trusted; this is not a movement. If it repeats, check the prism r1_r.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-11T0945_2026-10-22T0315"} {"id": "FLORIDA-24", "start": "2026-10-11T09:45Z", "end": "2026-10-11T22:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 5 goes down a little during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-11T0945_2026-10-22T0315"} {"id": "FLORIDA-74", "start": "2026-10-12T00:30Z", "end": "2026-10-12T01:00Z", "family": "Obstruction", "description": "At night, the raw position of the reference p1_r, one of the only two references of the station, shifts for one measurement while the targets do not move in the image (rigid fit on the targets) and its error_value does not rise: the camera pose jumps (pan, tilt, scale) and the corr_x of Sellette 4 and Sellette 5 jump clearly upward together, their corr_y a little, then come back at the next one. On the thumbnails of the hours of this night, a small bright point just beside the spot of p1_r is there at the measurements without a jump and absent at those with a jump: the measurement of p1_r is disturbed by this neighbouring point; its nature is not established. Same jumps later this night, labeled apart. It is not a movement of the structure: points to ignore.", "review": "2026-11-18", "analysis": "FLORIDA_2026-10-11T0945_2026-10-22T0315"} {"id": "FLORIDA-75", "start": "2026-10-12T01:45Z", "end": "2026-10-12T03:00Z", "family": "Obstruction", "description": "At night, the raw position of the reference p1_r, one of the only two references of the station, shifts for one measurement, then again a little later while the targets do not move in the image (rigid fit on the targets) and its error_value does not rise: the camera pose jumps (pan, tilt, scale) and the corr_x of Sellette 4 and Sellette 5 jump clearly upward together, their corr_y a little, then come back in between only halfway, fully after the second. On the thumbnails of the hours of this night, a small bright point just beside the spot of p1_r is there at the measurements without a jump and absent at those with a jump: the measurement of p1_r is disturbed by this neighbouring point; its nature is not established. Seen on the thumbnails of 01:00, 02:00 and 03:00. It is not a movement of the structure: points to ignore.", "review": "2026-11-18", "analysis": "FLORIDA_2026-10-11T0945_2026-10-22T0315"} {"id": "FLORIDA-76", "start": "2026-10-12T03:45Z", "end": "2026-10-12T04:30Z", "family": "Obstruction", "description": "At night, the raw position of the reference p1_r, one of the only two references of the station, shifts for one measurement while the targets do not move in the image (rigid fit on the targets) and its error_value does not rise: the camera pose jumps (pan, tilt, scale) and the corr_x of Sellette 4 and Sellette 5 jump clearly upward together, their corr_y a little, then come back over the next two. On the thumbnails of the hours of this night, a small bright point just beside the spot of p1_r is there at the measurements without a jump and absent at those with a jump: the measurement of p1_r is disturbed by this neighbouring point; its nature is not established. Seen on the thumbnails of 03:00 and 04:00. It is not a movement of the structure: points to ignore.", "review": "2026-11-18", "analysis": "FLORIDA_2026-10-11T0945_2026-10-22T0315"} {"id": "FLORIDA-77", "start": "2026-10-12T06:15Z", "end": "2026-10-12T06:45Z", "family": "Obstruction", "description": "At night, the raw position of the reference p1_r, one of the only two references of the station, shifts for one measurement while the targets do not move in the image (rigid fit on the targets) and its error_value does not rise: the camera pose jumps (pan, tilt, scale) and the corr_x of Sellette 4 and Sellette 5 jump clearly upward together, their corr_y a little, then come back at the next one. On the thumbnails of the hours of this night, a small bright point just beside the spot of p1_r is there at the measurements without a jump and absent at those with a jump: the measurement of p1_r is disturbed by this neighbouring point; its nature is not established. Same jumps earlier this night, labeled apart. It is not a movement of the structure: points to ignore.", "review": "2026-11-18", "analysis": "FLORIDA_2026-10-11T0945_2026-10-22T0315"} {"id": "FLORIDA-25", "start": "2026-10-12T07:45Z", "end": "2026-10-12T22:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 5 goes down during the day, the corr_y of Sellette 4 a little, and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-11T0945_2026-10-22T0315"} {"id": "FLORIDA-78", "start": "2026-10-12T22:15Z", "end": "2026-10-12T22:45Z", "family": "Obstruction", "description": "At night, the raw position of the reference p1_r, one of the only two references of the station, shifts for one measurement while the targets do not move in the image (rigid fit on the targets) and its error_value does not rise: the camera pose jumps (pan, tilt, scale) and the corr_x of Sellette 4 and Sellette 5 jump clearly upward together, their corr_y a little, then come back at the next one. On the thumbnails of the hours of this night, a small bright point just beside the spot of p1_r is there at the measurements without a jump and absent at those with a jump: the measurement of p1_r is disturbed by this neighbouring point; its nature is not established. Same signature as the jumps of the previous night; no image at that minute. It is not a movement of the structure: points to ignore.", "review": "2026-11-18", "analysis": "FLORIDA_2026-10-11T0945_2026-10-22T0315"} {"id": "FLORIDA-26", "start": "2026-10-13T08:45Z", "end": "2026-10-13T23:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 5 goes down during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-11T0945_2026-10-22T0315"} {"id": "FLORIDA-27", "start": "2026-10-14T01:15Z", "end": "2026-10-14T01:45Z", "family": "No data", "description": "One measurement absent for all sensors, and no image at that moment; the station nevertheless synchronizes at that moment and its voltage is normal: it is running, the measurement is missing; measurements resume at the next one. This one-measurement gap in the night, around 02:00 UTC, falls on the same measurement at FLORIDA and SNCF01 on 09, 14 and 15/10, and only on them; other stations have the same night gap around the same hour in other weeks (JUNGFRAU and NORDEND in early September): a common cause outside the station, at night, is probable; it is not established. Nothing to do on the station if it does not get worse.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-11T0945_2026-10-22T0315"} {"id": "FLORIDA-28", "start": "2026-10-14T08:45Z", "end": "2026-10-14T20:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 5 goes down during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-11T0945_2026-10-22T0315"} {"id": "FLORIDA-29", "start": "2026-10-15T01:45Z", "end": "2026-10-15T02:45Z", "family": "No data", "description": "Two measurements absent half an hour apart, with a single measurement between them, for all sensors, and no image at those moments; the station nevertheless synchronizes at those moments and its voltage is normal: it is running, the measurements are missing. This one-measurement gap in the night, around 02:00 UTC, falls on the same measurement at FLORIDA and SNCF01 on 09, 14 and 15/10, and only on them; other stations have the same night gap around the same hour in other weeks (JUNGFRAU and NORDEND in early September): a common cause outside the station, at night, is probable; it is not established. Nothing to do on the station if it does not get worse.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-11T0945_2026-10-22T0315"} {"id": "FLORIDA-31", "start": "2026-10-15T07:45Z", "end": "2026-10-15T22:45Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 5 and, a little, that of Sellette 4 go down during the day, until the measurements stop in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-11T0945_2026-10-22T0315"} {"id": "FLORIDA-32", "start": "2026-10-15T22:45Z", "end": "2026-10-16T10:45Z", "family": "No data", "description": "No measurement for any sensor during the night of 15 to 16, all the curves are missing; no image either, and no system metric over the range. The voltage is normal just before and just after; when the metrics return, a few entries were waiting to be sent. The gap starts at the same time, around 23:00, on the nine stations that were measuring then (LENZSPITZE only has its first measurements in the middle of that night, WILDSTRUBEL is already stopped), and their metrics stop at the same time on most of them; measurements and metrics resume at different times depending on the station, most of them in late morning. JUNGFRAU, whose metrics continue, accumulates unsent entries all night, sent in late morning, and yet its measurements for the night are missing from the data: a common cause outside the stations (transmission or reception of the data), not a shutdown of the stations; it is not established. The curves are missing over the range; nothing to do on the station if it does not repeat.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-11T0945_2026-10-22T0315"} {"id": "FLORIDA-34", "start": "2026-10-16T13:30Z", "end": "2026-10-16T14:00Z", "family": "No data", "description": "One measurement absent for all sensors, a few hours after the resumption of the 16th, and no image at that moment; the station nevertheless synchronizes at that moment, normal voltage. The same gap falls at the same moment on the other stations measuring at that time (JUNGFRAU, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-11T0945_2026-10-22T0315"} {"id": "FLORIDA-35", "start": "2026-10-16T14:15Z", "end": "2026-10-16T14:45Z", "family": "No data", "description": "One measurement absent for all sensors, three quarters of an hour after the previous one, and no image at that moment; normal voltage around it. The same gap falls at the same moment on the other stations measuring at that time (CLARIDEN, LENZSPITZE, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-11T0945_2026-10-22T0315"} {"id": "FLORIDA-37", "start": "2026-10-18T05:00Z", "end": "2026-10-18T08:00Z", "family": "Visibility", "description": "End of a night with reduced visibility: the error_value of all the targets and of p1_r rises; p1_r (with Sellette 3), Sellette 4, Sellette 5, Massif 2 and Sellette 6 are rejected at times, the camera is no longer registered for four measurements, and the kept measurements jump. 06:00 thumbnails: all the spots smaller and weaker than the night before, nothing in front; probably dampness or mist, cause not established. Back at daybreak, Sellette 4 the last. Not a movement: curves of the range to ignore.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-11T0945_2026-10-22T0315"} {"id": "FLORIDA-39", "start": "2026-10-18T19:30Z", "end": "2026-10-19T02:15Z", "family": "Visibility", "description": "Start of a night with reduced visibility: from 19h45, the error_value of p1_r rises, the camera pose goes wrong and the corr of Sellette 4 and Sellette 5 jumps; from 21h, Sellette 4, Sellette 5 and Sellette 6 are rejected almost over the whole range, p1_r (with Sellette 3) and Massif 2 most of the time, r1_r twice: the camera is almost no longer registered and the curves are missing; the kept measurements of Massif 2 and Sellette 6 jump. After the rejections end, the corr of Sellette 4 and Sellette 5 stay agitated until about 2h. 22:00 thumbnails: smaller and weaker spots, image of that hour without obstacle; cause not established (dampness probable). Not a movement: curves of the range to ignore.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-11T0945_2026-10-22T0315"} {"id": "FLORIDA-40", "start": "2026-10-19T09:00Z", "end": "2026-10-19T10:15Z", "family": "No data", "description": "Four measurements absent for all sensors, and no image; the station nevertheless synchronizes within the hour and the voltage is normal. The same gap falls at the same moment on the other stations measuring at that time (CLARIDEN, JUNGFRAU, LENZSPITZE, NIEDERHORN, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-11T0945_2026-10-22T0315"} {"id": "FLORIDA-41", "start": "2026-10-19T10:45Z", "end": "2026-10-19T22:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 5 goes down a little during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-11T0945_2026-10-22T0315"} {"id": "FLORIDA-42", "start": "2026-10-19T20:45Z", "end": "2026-10-19T21:15Z", "family": "No data", "description": "One measurement absent for all sensors, and no image at that moment; measurements resume at the next one. The same gap falls at the same moment on the other stations measuring at that time (CLARIDEN, JUNGFRAU, LENZSPITZE, NIEDERHORN, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station. The hourly metrics of BREITHORN, MICHIGAN and NEBRASKA are also missing at 21:00.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-11T0945_2026-10-22T0315"} {"id": "FLORIDA-44", "start": "2026-10-20T09:45Z", "end": "2026-10-20T15:15Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 5 and Sellette 6 goes down a little during the day, until the poor-visibility episode of the afternoon. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-11T0945_2026-10-22T0315"} {"id": "FLORIDA-45", "start": "2026-10-20T15:15Z", "end": "2026-10-21T18:30Z", "family": "Visibility", "description": "Long episode of poor visibility while the housing temperature drops: Sellette 4 and Sellette 5 rejected from the afternoon of the 20th, then through the night and the whole day of the 21st p1_r (with Sellette 3) and r1_r (with Pont Ernen) are rejected in turn: the camera is almost no longer registered, most of the curves are missing, and the kept measurements (Massif 2, Sellette 6, Pont Ernen) jump strongly. Seen on the 06:00 image on the 21st: scene veiled, wet leaves; 10:00 thumbnails: weak spots. Rain or mist. Not a movement: curves of the range to ignore.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-11T0945_2026-10-22T0315"} {"id": "FLORIDA-3", "start": "2026-10-01T09:45Z", "end": "2026-10-01T19:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 6, Massif 2 and Sellette 4 rises a little during the day, the corr_y of Sellette 6 too, and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-01T0000_2026-10-11T0945"} {"id": "FLORIDA-65", "start": "2026-10-01T20:30Z", "end": "2026-10-02T08:45Z", "family": "Visibility", "description": "Night of rain or mist: from 20:45 the error_value of all the targets and of both references rises together and the corrected curves of Sellette 4 and Sellette 5 already shift a little; from 21:00 p1_r (and its twin Sellette 3), Sellette 4 and Sellette 5 are rejected all night and the camera is no longer registered until the morning. From 21:00 to 22:30 the kept measurements of Massif 2 and Sellette 6 jump strongly downward in corr_y (compensation on r1_r alone); from 22:45 to about 02:00 almost all the sensors are rejected, then only rare points remain, still shifted. Seen on the 00:00 image: very weak spots, drops on the leaves in the foreground. Everything comes back in the morning, Sellette 4 last. The structure does not move: nothing to do, curves of the range to ignore.", "review": "2026-11-18", "analysis": "FLORIDA_2026-10-01T0000_2026-10-11T0945"} {"id": "FLORIDA-5", "start": "2026-10-02T01:45Z", "end": "2026-10-02T02:15Z", "family": "No data", "description": "One measurement absent for all sensors, although the image of that moment exists; the station synchronizes at that moment and its voltage is normal: it is running, the measurement is missing; measurements resume at the next one. SNCF01 has no data yet that day. This one-measurement gap in the night, around 02:00 UTC, falls on the same measurement at FLORIDA and SNCF01 on 09, 14 and 15/10, and only on them; other stations have the same night gap around the same hour in other weeks (JUNGFRAU and NORDEND in early September): a common cause outside the station, at night, is probable; it is not established. Nothing to do on the station if it does not get worse.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-01T0000_2026-10-11T0945"} {"id": "FLORIDA-66", "start": "2026-10-02T08:30Z", "end": "2026-10-02T09:45Z", "family": "Visibility", "description": "The morning after the rain, the reference r1_r, one of the only two references of the station, loses its light without being rejected: on the 09:00 thumbnail its spot is barely visible, much fainter than on the 11:00 thumbnail and than the 3rd at 09:00, nothing in front of it. Its measured position slides against the targets, the camera pose (pan, scale) goes off, and the compensation passes it into all the targets: the corr_x of Massif 2 and Sellette 5 rise, that of Sellette 4 drops, the corr_y of Sellette 6 drops, then everything comes back at 09:45. Deduced cause: a reference that loses its brightness after the rain, without obstacle. With two references, the slightest error of one passes into all the points: points to ignore; this is not a movement.", "review": "2026-11-18", "analysis": "FLORIDA_2026-10-01T0000_2026-10-11T0945"} {"id": "FLORIDA-67", "start": "2026-10-02T09:45Z", "end": "2026-10-02T10:30Z", "family": "Visibility", "description": "r1_r, one of the only two references of the station, sees its error_value rise above the threshold for two measurements, in the morning: it is rejected and the camera is no longer registered. The corrected curves are then computed on p1_r alone: the corr_x of Massif 2, Sellette 4 and Sellette 5, and the corr_y of Massif 2 and Sellette 5, jump a little and return at the next registration. Pont Ernen, the twin of r1_r, is rejected with it. Raw positions of the targets without a step. Seen on the 10:00 thumbnail: the background behind r1_r, a tiny spot, is in full sun and its spot drowns in it; the same sunlit background comes back on the other sunny mornings at that hour. Not a movement: data of the range not to be trusted, nothing to do on the structure.", "review": "2026-11-18", "analysis": "FLORIDA_2026-10-01T0000_2026-10-11T0945"} {"id": "FLORIDA-68", "start": "2026-10-02T10:30Z", "end": "2026-10-02T11:00Z", "family": "Visibility", "description": "For one measurement in late morning, the error_value of the reference p1_r (and of its twin Sellette 3) rises clearly, under its threshold: the compensation, on two references only, is distorted and the corr_x of Sellette 4, Sellette 5 and Sellette 6 jump down together, then return at the next measurement; Massif 2 is rejected at the same instant (labeled separately). No image at that instant; the scene is in full daylight at 10:00 and 11:00. Cause not established, probably the morning light on the reference. Not a movement: points to ignore.", "review": "2026-11-18", "analysis": "FLORIDA_2026-10-01T0000_2026-10-11T0945"} {"id": "FLORIDA-8", "start": "2026-10-02T10:45Z", "end": "2026-10-02T18:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 6, Massif 2 and Sellette 4 rises a little during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-01T0000_2026-10-11T0945"} {"id": "FLORIDA-70", "start": "2026-10-02T18:00Z", "end": "2026-10-02T18:30Z", "family": "Visibility", "description": "At nightfall, Massif 2 alone keeps one measurement with its error_value just under the threshold, and its corr_y jumps clearly upward, then returns at the next measurement; the other targets do not move. On the 18:00 thumbnail its spot is as usual. Deduced cause: a weak spot at the change of light, as at its other isolated rejections before its Target issue (from the 6th, labeled separately). Point to ignore; this is not a movement.", "review": "2026-11-18", "analysis": "FLORIDA_2026-10-01T0000_2026-10-11T0945"} {"id": "FLORIDA-71", "start": "2026-10-02T18:30Z", "end": "2026-10-02T23:30Z", "family": "Visibility", "description": "At the start of the night, the reference r1_r, one of the only two references of the station, weakens: on the thumbnails from 19:00 to 22:00 its spot is smaller than at 18:00 and 23:00, nothing in front. Its measured position slides against the targets and the camera pose follows it; the compensation passes it into the targets: the corr_x of Massif 2, Sellette 5 and Sellette 6 rise a little from 18:45 to 21:45. In the middle of it, the error_value of p1_r (and of its twin Sellette 3) rises for one measurement at 21:00, Sellette 4 jumps down; Massif 2 is rejected for two measurements, its curve is missing, and its corr_y stays low at the next one. Then p1_r flickers: at 22:30, 22:45 and 23:15 the corr_x of Sellette 4, Sellette 5 and Massif 2 drop together and come back at 23:30. Deduced cause: references that lose part of their light at night, without obstacle. Points to ignore; this is not a movement.", "review": "2026-11-18", "analysis": "FLORIDA_2026-10-01T0000_2026-10-11T0945"} {"id": "FLORIDA-10", "start": "2026-10-03T08:45Z", "end": "2026-10-03T19:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 6, Massif 2 and Sellette 4 rises a little during the day, the corr_y of Sellette 4 goes down a little, and everything returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-01T0000_2026-10-11T0945"} {"id": "FLORIDA-72", "start": "2026-10-04T08:30Z", "end": "2026-10-04T09:00Z", "family": "Perturbation", "description": "One-measurement jump of the corr_x of Sellette 5, Massif 2 and Sellette 6 (Sellette 4 a little), all downward, then back at the next measurement: in the raw image the targets do not move against each other, while the reference r1_r is measured slightly shifted alone for this measurement, without its error_value rising; the camera pose (tilt, scale) jumps with it and the compensation, on two references only, passes the jump into the targets. No image at that instant; on the 08:00 and 09:00 thumbnails r1_r looks as usual. Cause not established. Not a movement: points to ignore.", "review": "2026-11-18", "analysis": "FLORIDA_2026-10-01T0000_2026-10-11T0945"} {"id": "FLORIDA-11", "start": "2026-10-04T11:45Z", "end": "2026-10-04T18:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 6, Massif 2 and Sellette 4 rises a little during the day, the corr_y of Sellette 4 goes down a little, and everything returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-01T0000_2026-10-11T0945"} {"id": "FLORIDA-12", "start": "2026-10-05T07:45Z", "end": "2026-10-05T19:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 6, Massif 2 and Sellette 4 rises a little during the day, the corr_y of Sellette 4 goes down a little, and everything returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-01T0000_2026-10-11T0945"} {"id": "FLORIDA-13", "start": "2026-10-06T09:45Z", "end": "2026-10-06T22:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 6 rises during the day, that of Sellette 5 and the corr_y of Sellette 4 go down a little, and everything returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-01T0000_2026-10-11T0945"} {"id": "FLORIDA-80", "start": "2026-10-07T08:45Z", "end": "2026-10-07T20:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day. Most of it is absorbed by the compensation, but not all: the corr_y of Sellette 6 rises clearly above its night level in the afternoon and comes back in the evening, and the corr_y of Massif 2 dips around midday; the other targets stay close to their night level. Deduced: the camera movement follows the housing temperature, ordinary error_value. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-18", "analysis": "FLORIDA_2026-10-01T0000_2026-10-11T0945"} {"id": "FLORIDA-16", "start": "2026-10-08T03:15Z", "end": "2026-10-09T08:00Z", "family": "Visibility", "description": "Rainy day and damp night: the error_value of the targets and the references rises from 3h30, and the targets jump from that measurement; p1_r (and its twin Sellette 3) is rejected at times until the evening, Sellette 4 and Sellette 5 almost over the whole range, Massif 2 and Sellette 6 often. When p1_r is kept but poorly seen, the camera pose goes off (tilt, scale) and the corr of all the targets jumps strongly; when it is rejected, no more registration. Seen on the images: drops on the leaves at 05:00, scene veiled at 14:00, smaller spots. Back on the morning of the 9th. Not a movement: curves of the range to ignore.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-01T0000_2026-10-11T0945"} {"id": "FLORIDA-17", "start": "2026-10-09T01:45Z", "end": "2026-10-09T02:15Z", "family": "No data", "description": "One measurement absent for all sensors, and no image at that moment; the station nevertheless synchronizes at that moment and its voltage is normal: it is running, the measurement is missing; measurements resume at the next one. This one-measurement gap in the night, around 02:00 UTC, falls on the same measurement at FLORIDA and SNCF01 on 09, 14 and 15/10, and only on them; other stations have the same night gap around the same hour in other weeks (JUNGFRAU and NORDEND in early September): a common cause outside the station, at night, is probable; it is not established. Nothing to do on the station if it does not get worse.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-01T0000_2026-10-11T0945"} {"id": "FLORIDA-18", "start": "2026-10-09T08:00Z", "end": "2026-10-09T13:30Z", "family": "Perturbation", "description": "After the rain episode of the 8th, the corr_x of Sellette 5, already shifted upward at the end of the rain, and that of Sellette 4, which joins it in the early afternoon of the 9th, take a slightly higher level and stay there until the morning of the 15th; at the same time the camera pose has changed level (tilt, scale) and the error_value of r1_r is lower than before the rain. A reference spot that changes appearance changes the basis; the housing temperature also drops on those days and rises again when the shift fades, but at equal temperature, on the 17th and 18th, Sellette 5 does not have this level: link not established. Cause not established. The shift fades on the morning of the 15th: nothing to do, points to ignore.", "analysis": "FLORIDA_2026-10-01T0000_2026-10-11T0945"} {"id": "FLORIDA-81", "start": "2026-10-10T06:45Z", "end": "2026-10-10T20:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day. Apart from the p1_r episode of the morning (labeled separately), the corrected curves keep part of it: the corr_x of Sellette 6 and Massif 2 rise above their night level in the afternoon, then at the end of the day the corr_x of Sellette 5 and the corr_y of Sellette 6 go below it before returning to it in the night. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the morning episode. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-18", "analysis": "FLORIDA_2026-10-01T0000_2026-10-11T0945"} {"id": "FLORIDA-22", "start": "2026-10-10T07:15Z", "end": "2026-10-10T11:30Z", "family": "Visibility", "description": "In the morning, the error_value of p1_r rises from 7h30 and the corr_y of Sellette 4 and Sellette 5 shifts; then p1_r (and its twin Sellette 3) goes above the threshold and is rejected for several measurements, Sellette 5 and Sellette 6 too: the camera is no longer registered, and at the kept measurements the corr_x of Sellette 4 jumps clearly then returns. Thumbnails: the spot of p1_r has a wider halo at 09:00 than at 13:00, scene in full daylight without obstacle; probably the morning light, cause not established. Not a movement: curves of the range to ignore.", "review": "2026-11-17", "analysis": "FLORIDA_2026-10-01T0000_2026-10-11T0945"}