{"start": "2026-10-10T16:15Z", "end": "2026-10-11T07:30Z", "family": "Thermal displacement", "description": "Cooling of the night: the corr_y of the bridge targets rises steadily until morning, the camera tilt follows. Deduced from the curves and the camera housing temperature, which drops: the bridge rises as it cools. Normal, nothing to do.", "review": "2026-11-17"} {"start": "2026-10-11T07:30Z", "end": "2026-10-11T16:15Z", "family": "Thermal displacement", "description": "Warming of the day: the corr_y of the bridge targets sinks until the middle of the afternoon, then stays flat until nightfall; the camera pose follows. Deduced from the curves and the camera housing temperature. Normal, nothing to do.", "review": "2026-11-17"} {"start": "2026-10-11T16:15Z", "end": "2026-10-12T07:30Z", "family": "Thermal displacement", "description": "Cooling of the evening and the night: from late afternoon the camera tilt rises again while the corr_y of the bridge targets stays at its trough, then from nightfall the corr_y of the bridge targets rises until morning, the camera tilt too; references stable, very stable error_value. Deduced from the curves and the camera housing temperature, which drops from late afternoon: the bridge rises as it cools, and the camera fixed to it compensates it poorly. Normal, nothing to do.", "review": "2026-11-18"} {"start": "2026-10-12T07:30Z", "end": "2026-10-12T17:45Z", "family": "Thermal displacement", "description": "Warming of the day: the corr_y of the bridge targets sinks strongly all day, the corr_x of most rises in the afternoon then returns; the camera pose follows. References stable, ordinary error_value. Deduced from the curves and the camera housing temperature. Normal, nothing to do.", "review": "2026-11-17"} {"start": "2026-10-12T15:45Z", "end": "2026-10-12T16:15Z", "family": "Visibility", "description": "Small one-measurement jump on the corr_x of several targets (BJ_C, BJ_G, BL_G, PBJ_C, PBL_D, PM_D), then return. The error_value of the reference REF_G rises for the duration of one measurement, under its threshold: on the 16:00 thumbnail, the background behind it is lit by the sun and its spot drowns in it; the compensation is slightly distorted by it. This is not a movement; nothing to do.", "review": "2026-11-17"} {"start": "2026-10-12T17:45Z", "end": "2026-10-13T07:15Z", "family": "Thermal displacement", "description": "Cooling of the night: the corr_y of the bridge targets rises steadily until morning, the camera tilt follows. Deduced from the curves and the camera housing temperature, which drops: the bridge rises as it cools. Normal, nothing to do.", "review": "2026-11-17"} {"start": "2026-10-13T01:00Z", "end": "2026-10-13T02:45Z", "family": "Visibility", "description": "The references REF_G and REF_D are seen less well at night: their error_value rises clearly, under the threshold, and the reprojection error increases; the corr_x of several targets (BL_C, BL_G, PBJ_C, PBL_C, PM_C, BJ_G) shifts a little, then returns when REF_G becomes sharp again. Nothing visible on the thumbnails; the cause of the obstruction is not established. This is not a movement; do not trust these small deviations.", "review": "2026-11-17"} {"start": "2026-10-13T07:15Z", "end": "2026-10-13T18:15Z", "family": "Thermal displacement", "description": "Warming of the day: from sunrise, the corr_y of the bridge targets sinks all day; references very stable in position and error_value, error_value of the targets stable; the camera tilt drops faster than the targets. Deduced from the curves and the camera housing temperature. The bridge expands, poorly compensated by the camera fixed to it: normal, nothing to do.", "review": "2026-11-17"} {"start": "2026-10-13T18:15Z", "end": "2026-10-14T07:45Z", "family": "Thermal displacement", "description": "Weak cooling of the night: the corr_y of the bridge targets stays almost flat until the middle of the night, then rises until morning; the camera tilt rises too. Deduced from the curves and the camera housing temperature, which drops. Normal, nothing to do.", "review": "2026-11-17"} {"start": "2026-10-13T23:45Z", "end": "2026-10-14T05:30Z", "family": "Visibility", "description": "The references REF_G and REF_D are seen poorly at night: their error_value rises strongly, under the threshold, the reprojection error rises; the corr_x of several targets (BJ_G, PBJ_C, BJ_C, BL_G) shifts, first in one direction then in the other when REF_G becomes sharp again. The 02:15 image is slightly veiled (halo around the spots), perhaps mist; cause not established. This is not a movement. The shifts stay small and do not all return before daylight; according to the expert (the same night, his label of PS_DES_COUDRES, which is this station), two references veiled at night, condensation or mist, negligible deviations: nothing to do.", "review": "2026-11-17"} {"start": "2026-10-14T07:45Z", "end": "2026-10-14T16:45Z", "family": "Thermal displacement", "description": "Warming of the day: the corr_y of the bridge targets sinks strongly, the corr_x of most rises in the afternoon; the camera pose follows. References stable, ordinary error_value of the targets. Deduced from the curves and the camera housing temperature, which rises clearly. Normal, nothing to do.", "review": "2026-11-17"} {"start": "2026-10-14T09:15Z", "end": "2026-10-14T09:45Z", "family": "No data", "description": "One measurement is missing for all sensors, and the image of that moment too; the station nevertheless synchronizes at that moment and its voltage is normal (metrics): it is running, the measurement is not made or not recorded; only station affected that day at that hour, cause not established. The curves resume at the next measurement: nothing to do.", "review": "2026-11-17"} {"start": "2026-10-14T15:45Z", "end": "2026-10-14T16:15Z", "family": "Visibility", "description": "Small one-measurement jump on the corr_x of several targets (BJ_G, BL_G, PBJ_C, PM_C, PM_D), then return. The error_value of the reference REF_G rises for the duration of one measurement: on the 16:00 thumbnail, the background behind it is in full sun and its spot drowns in it. This is not a movement; nothing to do.", "review": "2026-11-17"} {"start": "2026-10-14T16:45Z", "end": "2026-10-15T08:30Z", "family": "Thermal displacement", "description": "Cooling of the night: the corr_y of the bridge targets rises steadily until morning, the camera tilt follows; the loss of the references in the middle of the night is superimposed on it (separate label), and the underlying trend remains this cooling. Deduced from the curves and the camera housing temperature, which drops. Normal, nothing to do.", "review": "2026-11-17"} {"start": "2026-10-14T23:00Z", "end": "2026-10-15T08:00Z", "family": "Visibility", "description": "Two references lost, the camera is blind: the error_value of REF_G then REF_D rises strongly, the reprojection error rises first; REF_G is rejected, then REF_D too (the camera is no longer registered at all for two hours), then REF_G comes back alone with REF_CT (reprojection at zero, two references) before REF_D comes back. All the targets jump in steps on corr_x and corr_y at each switch, then return. Once accepted again, REF_D is still seen poorly, in jolts, until early morning, and the targets (BJ_D, BJ_G, PBJ_C above all) stay a little shifted until it becomes sharp again. The cause of the poor visibility of the references is not established (very humid night at the nearby MeteoSwiss station, no rain). Every measurement of the range is invalid; if it repeats, check the state of the reference prisms.", "review": "2026-11-18"} {"start": "2026-10-15T08:30Z", "end": "2026-10-15T17:00Z", "family": "Thermal displacement", "description": "Warming of the day: the corr_y of the bridge targets sinks strongly, the corr_x rises in the afternoon; the camera pose follows. References stable, ordinary error_value. Deduced from the curves and the camera housing temperature. Normal, nothing to do.", "review": "2026-11-17"} {"start": "2026-10-15T09:30Z", "end": "2026-10-15T10:00Z", "family": "No data", "description": "One measurement is missing for all sensors, and the image of that moment too; the station nevertheless synchronizes at that moment and its voltage is normal (metrics): it is running, the measurement is not made or not recorded; only station affected that day at that hour, cause not established. The curves resume at the next measurement: nothing to do.", "review": "2026-11-17"} {"start": "2026-10-15T15:30Z", "end": "2026-10-15T16:15Z", "family": "Visibility", "description": "Small one-measurement jumps on the corr_x of a few targets (BJ_C, BJ_G, BL_G, PBJ_C), then return: the error_value of the reference REF_G rises for the duration of one measurement, like the other afternoons when the sun lights the background behind it (seen on the 15:45 thumbnail: the background behind it is in full sun and its spot drowns in it). This is not a movement; nothing to do.", "review": "2026-11-17"} {"start": "2026-10-15T17:00Z", "end": "2026-10-15T22:45Z", "family": "Thermal displacement", "description": "Start of the night cooling: the corr_y of the bridge targets rises steadily from late afternoon, until the measurements stop. Deduced from the curves and the camera housing temperature, which drops. Normal, nothing to do.", "review": "2026-11-17"} {"start": "2026-10-15T22:45Z", "end": "2026-10-16T10:30Z", "family": "No data", "description": "No measurement for any sensor, and no image, for almost twelve hours, on the night of 15 to 16: all the curves are missing. The station metrics continue (normal voltage, regular synchronizations), and the number of unsent entries in its database rises all night then drops to zero in late morning: the station kept running and kept its data, but its measurements for the night are missing from the data. The gap starts at the same time, around 23:00, on the nine stations that were measuring then (LENZSPITZE only has its first measurements in the middle of that night, WILDSTRUBEL is already stopped), and their metrics stop at the same time on most of them; measurements and metrics resume at different times depending on the station, most of them in late morning. It is a common cause outside the stations (transmission or reception of the data), not a shutdown of the stations; it is not established. The curves are missing over the range; nothing to do on the station if it does not repeat.", "review": "2026-11-17"} {"start": "2026-10-16T10:30Z", "end": "2026-10-16T16:45Z", "family": "Thermal displacement", "description": "Warming of the day: when the measurements resume, the corr_y of the bridge targets sinks until late afternoon, the corr_x rises; the camera housing temperature rises clearly in the early afternoon. Deduced from the curves and the temperature. Normal, nothing to do.", "review": "2026-11-18"} {"start": "2026-10-16T13:30Z", "end": "2026-10-16T14:00Z", "family": "No data", "description": "One measurement is missing for all sensors, and the image of that moment too; the station nevertheless synchronizes at that moment, normal voltage. The same gap falls at the same moment on the other stations measuring at that time (FLORIDA, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-17"} {"start": "2026-10-16T15:30Z", "end": "2026-10-16T16:15Z", "family": "Visibility", "description": "Small one-measurement jumps on the corr_x of several targets (BJ_G, BL_C, BL_G, PBJ_C, PM_C, PM_D), in one direction then the other: the error_value of the reference REF_G rises, under its threshold; on the 15:45 thumbnail, the background behind it is in full sun and its spot drowns in it. This is not a movement; nothing to do.", "review": "2026-11-17"} {"start": "2026-10-16T16:45Z", "end": "2026-10-18T08:15Z", "family": "Thermal displacement", "description": "Rise over several days with the drop in temperature: after the last warm day, the corr_y of the bridge targets rises almost without stopping for two nights and the day between them, with only a weak dip during the day; the clear thermal phases fade out, then the targets stabilize. The camera housing temperature drops over the whole range, with no more daytime peak. Deduced from the temperature: the bridge rises as it cools. A real movement can reasonably be ruled out; nothing to do.", "review": "2026-11-17"} {"start": "2026-10-17T00:15Z", "end": "2026-10-17T04:45Z", "family": "Visibility", "description": "The references REF_G and REF_D are seen less well at night: their error_value rises clearly, under the threshold; the corr_x and corr_y of several targets (BJ_C, BJ_G, BL_C, BL_G, PBJ_C, PBL_C, PBL_D) make small common jumps, then return when the references become sharp again. Nothing visible on the thumbnails; cause not established. This is not a movement.", "review": "2026-11-17"} {"start": "2026-10-18T10:00Z", "end": "2026-10-19T10:15Z", "family": "Visibility", "description": "Visibility drops over the whole scene during a long rain: the error_value of almost all the targets and of the references REF_G and REF_CT rises clearly; PM_C is rejected almost all the time and disappears from the curves, PM_D and PBL_C are at times; the corrections become agitated, with common jumps and a shift of BJ_G, BJ_D, PBJ_C that are not movements. Rain measured at the nearby MeteoSwiss station from late morning to the early hours of 19/10, air close to saturation; seen on the 14:00 image: the road is wet and the scene slightly veiled; on the 21:00 image the background is veiled in grey and the spots have halos, nothing in front of the targets. The error_values stay high until the morning cutoff, after which everything returns. Do not trust the curves over the range.", "review": "2026-11-18"} {"start": "2026-10-19T08:45Z", "end": "2026-10-19T10:15Z", "family": "No data", "description": "No measurement for any sensor for more than an hour: all the curves are missing; the station nevertheless takes its image at the first missing measurement and synchronizes within the hour, normal voltage around it. The same gap falls at the same moment on the other stations measuring at that time (CLARIDEN, FLORIDA, LENZSPITZE, NIEDERHORN, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-18"} {"start": "2026-10-19T10:15Z", "end": "2026-10-19T20:00Z", "family": "Thermal displacement", "description": "Weak warming of the day: the corr_y of the bridge targets goes down slowly until evening, the camera housing temperature rises a little; the camera tilt goes down and stays low. Deduced from the curves and the temperature. Normal, nothing to do.", "review": "2026-11-17"} {"start": "2026-10-19T16:15Z", "end": "2026-10-20T11:00Z", "family": "Visibility", "description": "The three large spots nearest the camera, BJ_C, BJ_G and BJ_D, are seen less well from late afternoon and all night: their error_value rises clearly, and measurement by measurement, in step with it, the corr_x of BJ_G goes down and that of BJ_D rises (the two targets at the edges move apart in opposite directions) and the corr_y of all three goes down, then they come back together when it drops; the error_value of the other targets rises a little, the references stay calm, the camera pose and the housing temperature stay almost flat. The night after the rain is very humid at the nearby MeteoSwiss station; the 00:00 image is slightly veiled in grey, nothing in front of the spots. Cause deduced: a poorer view of these near spots in the humid air, not a thermal movement (the temperature does not change). Everything returns in the late morning of 20/10 as their error_value comes down. This is not a movement; do not trust the curves of BJ_C, BJ_G and BJ_D over the range.", "review": "2026-11-18"} {"start": "2026-10-19T20:30Z", "end": "2026-10-19T21:30Z", "family": "No data", "description": "Two measurements are missing half an hour apart, with a single measurement between them, for all sensors, and no image at those moments; normal voltage around them. The same gap falls at the same moment on the other stations measuring at that time (CLARIDEN, FLORIDA, LENZSPITZE, NIEDERHORN, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station. The hourly metrics of BREITHORN, MICHIGAN and NEBRASKA are also missing at 21:00.", "review": "2026-11-17"} {"start": "2026-10-20T11:00Z", "end": "2026-10-20T16:00Z", "family": "Thermal displacement", "description": "Weak warming of the day: the corr_y of the bridge targets (BJ_C, BJ_G, BJ_D above all) goes down until mid-afternoon and BJ_D and BJ_G move apart again in corr_x; the camera housing temperature rises a little. From mid-afternoon, the drop in visibility (separate label) is mixed in and accentuates it. Deduced from the curves and the temperature. Normal, nothing to do.", "review": "2026-11-17"} {"start": "2026-10-20T14:15Z", "end": "2026-10-21T09:15Z", "family": "Visibility", "description": "Visibility drops over the whole scene, mostly at night, during the rain: the error_value of almost all the targets and of the three references rises, very clearly for REF_D (peak in the evening) and REF_G (in jolts all night), without any reference being discarded; PM_C is rejected all evening then at times in the early morning. Seen on the 20:00 image: the background is veiled in gray, like a mist lit by the infrared, and the spots of REF_G and PM_C are smaller than on a clear night. The raw position of REF_G moves away from that of the other references, the camera pose computed from them is distorted and the corrections of many targets move slightly (corr_x of BL_C and PM_D, corr_y of the BJ targets); the thermal cycle of the evening is added and makes the case hard to read. Everything returns in the morning of 21/10. Cause: the rain, measured at the nearby MeteoSwiss station from late afternoon of 20/10 to the morning of 21/10 with air close to saturation, consistent with the grey veil of the night images; the structure does not move, data of the range less reliable, nothing to do.", "review": "2026-11-18"} {"start": "2026-10-20T16:00Z", "end": "2026-10-21T10:30Z", "family": "Thermal displacement", "description": "Cooling of the evening and the night: the corr_y of the bridge targets (BJ_C, BJ_G, BJ_D, PBJ_C above all) rises until the middle of the morning of 21/10, BJ_D and BJ_G move closer in corr_x; the drop in visibility of the night (separate label) is superimposed and makes reading difficult. Deduced from the curves and the camera housing temperature, which drops. The bridge rises as it cools: normal, nothing to do.", "review": "2026-11-17"}