{"id": "CLARIDEN-1", "start": "2026-10-01T00:00Z", "end": "2026-11-01T00:00Z", "family": "Target issue", "description": "The target P-300-B is rejected at every measurement of the batch: its recognition error stays almost at 1, its corrected curve is missing over the whole month. This has lasted since 29 September in the late afternoon, the time when the recognition error of other targets, including its neighbor P-301-B, also changes level all at once: a station setting changed that day. On the thumbnails (the 1st, the 15th and the 31st), the prism spot is sharp and bright, but next to the position where the system looks for it: the target seems badly configured or badly positioned, not hidden. Curve to ignore; correct the position of the target in the configuration or check the prism.", "review": "2026-11-17"} {"id": "CLARIDEN-14", "start": "2026-10-06T22:00Z", "end": "2026-10-11T06:00Z", "family": "Displacement", "description": "Slow drift of several targets over four days, made of small steps, then stabilization: D-303-B rises vertically, D-303-C and D-304-C rise vertically, D-301-C rises horizontally, D-306-B goes down horizontally. No camera movement, ordinary recognition error, nothing on the images; the position in the image of D-301-C and D-303-B moves slightly away from that of the other targets, in the direction of their curves. The camera housing temperature stays almost constant over these days: no link with it. Slow return from the 11th to the 19th, labeled separately. Cause not established, in a tunnel under construction: a movement of these targets is not excluded. To be checked against the other measurements of the site; monitor this row.", "review": "2026-11-17"}