{"id": "CLARIDEN-1", "start": "2026-10-01T00:00Z", "end": "2026-11-01T00:00Z", "family": "Target issue", "description": "The target P-300-B is rejected at every measurement of the batch: its recognition error stays almost at 1, its corrected curve is missing over the whole month. This has lasted since 29 September in the late afternoon, the time when the recognition error of other targets, including its neighbor P-301-B, also changes level all at once: a station setting changed that day. On the thumbnails (the 1st, the 15th and the 31st), the prism spot is sharp and bright, but next to the position where the system looks for it: the target seems badly configured or badly positioned, not hidden. Curve to ignore; correct the position of the target in the configuration or check the prism.", "review": "2026-11-04"} {"id": "CLARIDEN-2", "start": "2026-10-01T06:15Z", "end": "2026-10-01T08:45Z", "family": "Visibility", "description": "The recognition error of most targets rises together, first a little, then clearly around 07:50-08:00, and comes back down; at the same time the corrected curves of several targets make a bump that comes back: D-301-C horizontally, D-302-B and PR_BG (same prism) vertically, D-306-B, D-303-B, P-301-B, then around 08:00 D-301-A, D-302_A, D-304-A. The scene deforms a little (scale and rotation of the targets, references PR-291 and PR-293 moving away from the targets), without camera movement. Nothing on the 07:00 and 08:00 images, which are dark as always. Diffuse obstruction of the view in the tunnel, cause not established (the tunnel air?); same signature as the episodes of 2, 6, 18, 22 and 31 October. The structure does not move: do not trust the curves over the range.", "review": "2026-11-04"} {"id": "CLARIDEN-3", "start": "2026-10-01T17:45Z", "end": "2026-10-02T02:30Z", "family": "Displacement", "description": "The low targets of row B go down vertically from 18:00: D-306-B above all, which keeps going down into the night then stays low until the gap of 3 October, D-304-B and D-303-B (which, for its part, gradually rises until the 3rd). Raw positions almost motionless, no camera movement, ordinary recognition error, no image showing a cause. Cause not established, in a tunnel under construction: a movement of these targets is not excluded. To be checked against the other measurements of the site; monitor this row.", "review": "2026-11-04"} {"id": "CLARIDEN-4", "start": "2026-10-02T21:45Z", "end": "2026-10-02T23:00Z", "family": "Visibility", "description": "The recognition error of most targets rises together for one hour, and the corrected curves of D-304-B (vertical) above all, of D-301-C (horizontal), D-302-B and PR_BG, P-301-B, D-304-C make a bump that comes back; D-304-B is still shifted at the last measurement, before 23:00. The camera housing temperature drops clearly at the same time. Nothing visible on the 22:00 image. Diffuse obstruction of the view, cause not established, perhaps a change in the tunnel air. The structure does not move: curves to ignore over the range.", "review": "2026-11-04"} {"id": "CLARIDEN-5", "start": "2026-10-02T21:50Z", "end": "2026-10-02T23:20Z", "family": "Thermal displacement", "description": "The camera housing temperature drops clearly for one hour, and the camera scale deviates with it, then returns when the housing warms up; the strongest deviation comes after the curves have returned from the view obstruction of the same evening. The corrected curves do not follow this deviation: the compensation absorbs it. Camera movement by thermal effect, deduced from its pose against the housing temperature; normal, nothing to do.", "review": "2026-11-04"} {"id": "CLARIDEN-6", "start": "2026-10-03T07:40Z", "end": "2026-10-03T08:00Z", "family": "No data", "description": "One measurement is missing, for all sensors: the curves have a short gap. Cause not established.", "review": "2026-11-04"} {"id": "CLARIDEN-7", "start": "2026-10-03T17:30Z", "end": "2026-10-03T17:45Z", "family": "Visibility", "description": "Last measurement before the gap of 3 October: the same one-measurement bump on D-301-C, D-302-B and PR_BG, D-304-B, D-304-C, P-301-B, with the recognition error of many targets rising. Same signature as the episodes of view obstruction at the station; cause not established, perhaps linked to the station shutdown that follows. Point to ignore.", "review": "2026-11-04"} {"id": "CLARIDEN-8", "start": "2026-10-03T17:45Z", "end": "2026-10-05T10:30Z", "family": "No data", "description": "No measurement or image for almost two days, for all sensors, and the station metrics are missing too: the entire station stopped. Voltage and battery normal before and after the gap, so not the signature of a power cut; on resumption, the camera has moved and a blurred object is very close to the lens (10:30 image), which suggests an intervention on the station. Cause not established: the curves are missing over the range.", "review": "2026-11-04"} {"id": "CLARIDEN-9", "start": "2026-10-03T17:45Z", "end": "2026-10-05T10:45Z", "family": "Displacement", "description": "After the gap of 3 to 5 October, many targets resume at a different level, and do not return to the previous one until the end of the batch: D-304-C and D-303-C above all, in both directions, then D-302_A and D-301-A, P-299-B, D-300-C, D-303-B and D-304-B horizontally, D-301-C vertically; D-306-B, for its part, returns to its level from before its descent of the evening of the 1st. The raw positions of D-304-C and D-303-C have moved in the image relative to the other targets, the recognition error of several targets (D-302-C, D-301-C, D-303-C, D-304-C, D-301-A, D-306-B) also changes level, and the camera scale is no longer the same: the appearance of these targets and the camera pose changed during the shutdown. On resumption, a blurred object is very close to the lens (10:30 image). Cause not established: intervention or changed setting during the shutdown, or real movement; to be checked before trusting these new levels.", "review": "2026-11-04"} {"id": "CLARIDEN-10", "start": "2026-10-05T10:30Z", "end": "2026-10-05T11:20Z", "family": "Obstruction", "description": "First measurement after the gap: the whole scene, references included, is shifted by several pixels in the image and the camera is tilted, then it returns within twenty minutes; the compensation absorbs it poorly for the duration of one measurement, and the corrected curves of many targets jump then return (D-303-C, D-302-B and PR_BG, D-306-B, D-304-B, P-299-C above all; D-303-B stays slightly shifted until 11:10). D-304-C is rejected. The 10:30 image shows a large blurred object very close to the lens, on the right, which hides D-304-C, and a worker in reflective clothing in the tunnel, at the top left: work is going on around the camera. Points to ignore; the structure does not move.", "review": "2026-11-04"} {"id": "CLARIDEN-11", "start": "2026-10-05T12:10Z", "end": "2026-10-05T12:30Z", "family": "Obstruction", "description": "For the duration of one measurement, the whole right-hand row C (D-300-C, D-301-C, D-303-C, D-304-C, P-298-C, P-299-C) and the reference D-302-C are rejected, their recognition error almost at 1; the compensation runs without D-302-C and the targets that stayed under the threshold jump then return at the next measurement (D-306-B above all vertically, D-303-B, D-304-B, P-299-B, P-301-B, D-302-B and PR_BG). No image at 12:20: the cause is not seen, but the signature is that of something passing in front of the right-hand part of the scene. Point to ignore.", "review": "2026-11-04"} {"id": "CLARIDEN-12", "start": "2026-10-06T18:00Z", "end": "2026-10-06T22:10Z", "family": "Visibility", "description": "For four hours, the corrected curves of the same group of targets take a step that starts and ends sharply: D-301-C horizontally above all, D-302-B and PR_BG (same prism) horizontally then vertically, D-304-B vertically, and at times P-301-B, D-303-B, D-302_A, D-301-A, D-304-C. The recognition error of the references PR-293, PR-295, PR-296 and of a few targets rises a little; the references move away from each other in the image. The camera housing temperature drops clearly over these hours. Nothing visible on the 20:00 image. View obstruction of cause not established, probably the tunnel air (colder); the curves and the recognition error return at 22:00, before the camera scale (see the thermal label of the same evening). The structure does not move: curves to ignore over the range.", "review": "2026-11-04"} {"id": "CLARIDEN-13", "start": "2026-10-06T18:40Z", "end": "2026-10-06T22:40Z", "family": "Thermal displacement", "description": "The camera housing temperature drops clearly for four hours, and the camera scale deviates with it, then returns when the housing warms up, after the curves have returned from the view obstruction of the same evening. The corrected curves do not follow this deviation: the compensation absorbs it. Camera movement by thermal effect, deduced from its pose against the housing temperature; normal, nothing to do.", "review": "2026-11-04"} {"id": "CLARIDEN-14", "start": "2026-10-06T22:00Z", "end": "2026-10-11T06:00Z", "family": "Displacement", "description": "Slow drift of several targets over four days, made of small steps, then stabilization: D-303-B rises vertically, D-303-C and D-304-C rise vertically, D-301-C rises horizontally, D-306-B goes down horizontally. No camera movement, ordinary recognition error, nothing on the images; the position in the image of D-301-C and D-303-B moves slightly away from that of the other targets, in the direction of their curves. The camera housing temperature stays almost constant over these days: no link with it. Slow return from the 11th to the 19th, labeled separately. Cause not established, in a tunnel under construction: a movement of these targets is not excluded. To be checked against the other measurements of the site; monitor this row.", "review": "2026-11-04"} {"id": "CLARIDEN-15", "start": "2026-10-11T06:00Z", "end": "2026-10-20T00:20Z", "family": "Displacement", "description": "The targets of row C slowly come back after their drift of the 6th to the 11th: D-301-C goes back down horizontally from the 11th to the 15th, D-304-C and D-303-C go back down vertically from the 12th to the 19th, until the camera jump of the 20th shortly after midnight. No camera movement during these days, nothing in front of the targets on the 13th image at 12:00. The position in the image of D-301-C also partly returns toward that of the other targets. The camera housing temperature stays almost constant over these days: no link with it. This is the return of the drift of the 6th to the 11th, labeled separately. Cause not established, in a tunnel under construction: a movement of these targets is not excluded. To be checked against the other measurements of the site; monitor this row.", "review": "2026-11-04"} {"id": "CLARIDEN-16", "start": "2026-10-15T22:45Z", "end": "2026-10-16T10:30Z", "family": "No data", "description": "No measurement or image for almost twelve hours, on the night of 15 to 16, and no station metric. The gap starts at the same time, around 23:00, on the nine stations that were measuring then (LENZSPITZE only has its first measurements in the middle of that night, WILDSTRUBEL is already stopped), and their metrics stop at the same time on most of them; measurements and metrics resume at different times depending on the station, most of them in late morning. JUNGFRAU, whose metrics continue, accumulates unsent entries all night, sent in late morning, and yet its measurements for the night are missing from the data: a common cause outside the stations (transmission or reception of the data), not a shutdown of the stations; it is not established. In addition, at CLARIDEN, the station restarts on its battery: the voltage stays well below its usual level, without charge, until early afternoon, then charging resumes; its power supply was also missing that night. The curves are missing over the range; check the site power supply if it repeats.", "review": "2026-11-04"} {"id": "CLARIDEN-17", "start": "2026-10-16T14:20Z", "end": "2026-10-16T14:40Z", "family": "No data", "description": "One measurement is missing, for all sensors, a few hours after the resumption of the 16th: the curves have a short gap; normal voltage around it. The same gap falls at the same moment on the other stations measuring at that time (FLORIDA, LENZSPITZE, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-04"} {"id": "CLARIDEN-18", "start": "2026-10-18T09:00Z", "end": "2026-10-18T09:30Z", "family": "Visibility", "description": "For the duration of two measurements, the recognition error of several targets rises and the corrected curves of D-301-C (horizontal), D-302-B and PR_BG, P-301-B, D-302_A, D-304-B make a bump that comes back. The camera housing temperature drops at the same time. Same signature as the other episodes of view obstruction at the station, cause not established. Points to ignore.", "review": "2026-11-04"} {"id": "CLARIDEN-19", "start": "2026-10-18T13:45Z", "end": "2026-10-18T23:30Z", "family": "No data", "description": "No measurement or image for almost ten hours, nor station metric. On resumption, the battery is depleted and the voltage low, then they rise: signature of a power cut. The curves are missing over the range; check the power supply if it repeats.", "review": "2026-11-04"} {"id": "CLARIDEN-20", "start": "2026-10-19T09:00Z", "end": "2026-10-19T10:15Z", "family": "No data", "description": "Four measurements are missing within one hour, for all sensors, between isolated measurements: the curves have gaps; normal voltage around them. The same gap falls at the same moment on the other stations measuring at that time (FLORIDA, JUNGFRAU, LENZSPITZE, NIEDERHORN, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-04"} {"id": "CLARIDEN-21", "start": "2026-10-19T20:45Z", "end": "2026-10-19T21:30Z", "family": "No data", "description": "Three measurements are missing in less than an hour, for all sensors: the curves have a gap; normal voltage around it. The same gap falls at the same moment on the other stations measuring at that time (FLORIDA, JUNGFRAU, LENZSPITZE, NIEDERHORN, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station. The hourly metrics of BREITHORN, MICHIGAN and NEBRASKA are also missing at 21:00.", "review": "2026-11-04"} {"id": "CLARIDEN-22", "start": "2026-10-20T00:15Z", "end": "2026-10-20T00:45Z", "family": "Displacement", "description": "The whole scene, references included, suddenly shifts by a fraction of a pixel in the image: the camera has moved. The compensation absorbs it for most targets, but D-306-B keeps a jump vertically that remains, and D-303-C, D-302-B and PR_BG a smaller one. Cause of the camera movement not established; the jump of D-306-B is not an established movement of the structure: to be checked.", "review": "2026-11-04"} {"id": "CLARIDEN-23", "start": "2026-10-20T04:00Z", "end": "2026-10-25T18:00Z", "family": "Displacement", "description": "Slow drift of targets of row C, then stabilization at a new level: D-301-C rises horizontally from the 20th, D-304-C and D-303-C rise vertically mostly from the 22nd. No camera movement, ordinary recognition error. The rise of D-301-C starts before the work seen around the station on the 22nd (workers and a frame): no link established. The position in the image of D-301-C, D-304-C and D-303-C moves clearly away from that of the other targets, in the direction of their curves. The camera housing temperature stays almost constant over these days: no link with it. Partial return from the 26th to the 29th, labeled separately. Cause not established, in a tunnel under construction: a movement of these targets is not excluded. To be checked against the other measurements of the site; monitor this row.", "review": "2026-11-04"} {"id": "CLARIDEN-24", "start": "2026-10-20T06:10Z", "end": "2026-10-20T06:30Z", "family": "No data", "description": "One measurement is missing, for all sensors: the curves have a short gap; the station nevertheless synchronizes at that moment, normal voltage. The same moment is also missing at LENZSPITZE, and at no other station: a common cause outside the station is possible, not established. Nothing to do.", "review": "2026-11-04"} {"id": "CLARIDEN-25", "start": "2026-10-20T20:45Z", "end": "2026-10-20T21:45Z", "family": "No data", "description": "Five measurements are missing within one hour, for all sensors: the curves have a gap. The station is nevertheless running (continuous synchronizations, 21:00 image, normal voltage): the measurement is not made or not recorded. The 21:00 measurement is also missing at NIEDERHORN, and at no other station: a common cause is possible, not established. Nothing to do.", "review": "2026-11-04"} {"id": "CLARIDEN-26", "start": "2026-10-22T06:30Z", "end": "2026-10-22T08:45Z", "family": "Visibility", "description": "In two phases, from 06:40 to 06:50 then from 07:50 to 08:30, the recognition error of several targets and of the references D-302-C and PR-293 rises, and the corrected curves of the usual group make a bump that comes back: D-301-C horizontally, D-302-B and PR_BG vertically, P-301-B, D-304-B, D-304-C, and at the start D-302_A, P-298-A, D-304-A, D-303-A; between the two, D-302-B and PR_BG move once more. The camera housing temperature drops during these hours. The 08:00 image shows lights at the far end of the tunnel (machine or vehicle), nothing in front of the targets. Diffuse view obstruction of cause not established, the same as in the other episodes at the station. Curves to ignore over the range; the structure does not move.", "review": "2026-11-04"} {"id": "CLARIDEN-27", "start": "2026-10-22T08:00Z", "end": "2026-10-22T09:20Z", "family": "Thermal displacement", "description": "The camera housing temperature drops clearly on the morning of the 22nd, and the camera scale deviates with it, mostly after the curves have returned from the view obstruction of the same hour, then returns when the housing warms up. The corrected curves do not follow this deviation: the compensation absorbs it. Camera movement by thermal effect, deduced from its pose against the housing temperature; normal, nothing to do.", "review": "2026-11-04"} {"id": "CLARIDEN-28", "start": "2026-10-22T08:45Z", "end": "2026-10-22T17:00Z", "family": "Displacement", "description": "The low targets of row B rise vertically during the day: D-306-B above all, D-302-B and PR_BG, D-304-B, D-303-B; the recognition error of a few of them rises a little. Workers are visible in the tunnel on the 12:00 image, and a frame appears very close to the camera at the top of the image at 13:00 (it stays there until the end of the batch): work around the station. The position in the image of D-306-B rises a little relative to the other targets, in the direction of its curve. The link between this work and the rise is not established. Evening descent, labeled separately. Cause not established, in a tunnel under construction: a movement of these targets is not excluded. To be checked against the other measurements of the site; monitor this row.", "review": "2026-11-04"} {"id": "CLARIDEN-29", "start": "2026-10-22T17:00Z", "end": "2026-10-23T10:30Z", "family": "Displacement", "description": "The low targets of row B go back down vertically, all at once on the evening of the 22nd then more slowly on the morning of the 23rd, to below their level from before their rise of the day: D-306-B above all, D-304-B, D-303-B, D-302-B and PR_BG. No camera movement; the frame installed on the 22nd stays at the top of the image (19:00 image), nothing else. The position in the image of D-306-B also goes down relative to the other targets. This is the return of the rise of the day, labeled separately, and it goes beyond it. Cause not established, in a tunnel under construction: a movement of these targets is not excluded. To be checked against the other measurements of the site; monitor this row.", "review": "2026-11-04"} {"id": "CLARIDEN-30", "start": "2026-10-24T01:00Z", "end": "2026-10-24T05:00Z", "family": "Displacement", "description": "The low targets of row B (D-306-B above all, D-304-B, D-303-B) partly rise again vertically in the night of the 24th, toward their level from before the descent of the evening of the 22nd, without reaching it. No camera movement. Cause not established, in a tunnel under construction: a movement of these targets is not excluded. To be checked against the other measurements of the site; monitor this row.", "review": "2026-11-04"} {"id": "CLARIDEN-31", "start": "2026-10-24T18:20Z", "end": "2026-10-25T19:10Z", "family": "Displacement", "description": "The left targets of row A (D-302_A, D-303-A, D-304-A, D-301-A, P-299-A) and D-304-B, D-306-B, P-301-B fidget in jolts (around 18:30 and 21:30 on the 24th, 07:00 and 15:30 on the 25th): the vertical rises, the horizontal goes down; the recognition error of these targets and of the reference D-302-C rises during the first jolts, and the references PR-291 and PR-293 move slightly away from the targets in the image. Everything calms down on the evening of the 25th. After the agitation, the horizontal of the A targets stays shifted until the end of the batch. Workers are visible on the image of the 24th at 15:00 and the frame is still at the top of the image. Cause not established: shift to be checked.", "review": "2026-11-04"} {"id": "CLARIDEN-32", "start": "2026-10-25T18:00Z", "end": "2026-10-29T04:00Z", "family": "Displacement", "description": "After their rise of the 20th to the 25th, D-304-C and D-303-C slowly go back down vertically from the 26th to the 29th, without returning to their level from before the rise, then stabilize. No camera movement, nothing in front of the targets on the images of the 28th at 19:00 and 20:00. Their position in the image also partly returns toward that of the other targets. This is the partial return of the rise of the 20th to the 25th, labeled separately. Cause not established, in a tunnel under construction: a movement of these targets is not excluded. To be checked against the other measurements of the site; monitor this row.", "review": "2026-11-04"} {"id": "CLARIDEN-33", "start": "2026-10-26T14:30Z", "end": "2026-10-26T15:15Z", "family": "No data", "description": "Three measurements are missing in less than an hour, for all sensors: the curves have a gap; normal voltage around it. The same gap falls at the same moment on the other stations measuring at that time (FLORIDA, JUNGFRAU, LENZSPITZE, NIEDERHORN, NORDEND, SNCF01), and their metrics are also missing at the same minutes: a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station. The hourly metrics of BREITHORN, MICHIGAN and NEBRASKA are also missing at 15:00.", "review": "2026-11-04"} {"id": "CLARIDEN-34", "start": "2026-10-27T09:00Z", "end": "2026-10-27T09:30Z", "family": "No data", "description": "Two measurements are missing, for all sensors: the curves have a short gap; normal voltage around it. The same gap falls at the same moment on the other stations measuring at that time (FLORIDA, JUNGFRAU, LENZSPITZE, NORDEND): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-04"} {"id": "CLARIDEN-35", "start": "2026-10-27T12:00Z", "end": "2026-10-27T12:20Z", "family": "Target issue", "description": "For the duration of one measurement, the target PR-284 jumps by several pixels horizontally and vertically, then returns: the measured position has left its spot, with a high recognition error but under the threshold, so kept in the curve. Since 24 October around 14:20, the spot of PR-284 is clearly weaker (thumbnails of the 24th at 12:00 and 16:00, of the 27th at 12:00) and its recognition error has stayed high. False point to ignore; look at the state of the target PR-284 if the false points repeat.", "review": "2026-11-04"} {"id": "CLARIDEN-36", "start": "2026-10-28T19:20Z", "end": "2026-10-28T20:10Z", "family": "Displacement", "description": "On the evening of the 28th, the low targets of row B go down by a step vertically, D-306-B above all, then D-304-B, and stay at this new level until the end of the batch; D-303-B and D-304-B also go down a little horizontally. The position in the image of D-306-B goes down a little relative to the other targets, no camera movement, nothing on the 19:00 and 20:00 images (the frame at the top of the image is still there). Cause not established, in a tunnel under construction: a movement of these targets is not excluded. To be checked against the other measurements of the site; monitor this row.", "review": "2026-11-04"} {"id": "CLARIDEN-37", "start": "2026-10-29T14:50Z", "end": "2026-10-29T15:10Z", "family": "No data", "description": "One measurement is missing, for all sensors: the curves have a short gap; the station nevertheless synchronizes at that moment, normal voltage. The same gap falls at the same moment on the other stations measuring at that time (LENZSPITZE, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-04"} {"id": "CLARIDEN-38", "start": "2026-10-29T23:45Z", "end": "2026-10-30T00:15Z", "family": "Target issue", "description": "At midnight, D-302-B jumps vertically and a little horizontally and stays at this new level until the end of the batch; PR_BG, on the same prism, jumps in the opposite direction. The raw positions of the two sensors do not move, only their starting position has changed (the relative displacement jumps without any movement in the image): a configuration or processing change of these two sensors, not a movement of the structure. Check their configuration with the operator; do not read this jump as a movement, nor compare their curves before and after.", "review": "2026-11-04"} {"id": "CLARIDEN-39", "start": "2026-10-30T17:00Z", "end": "2026-10-30T17:45Z", "family": "No data", "description": "Four measurements are missing in less than an hour, for all sensors: the curves have a gap. Cause not established.", "review": "2026-11-04"} {"id": "CLARIDEN-40", "start": "2026-10-31T13:45Z", "end": "2026-10-31T15:10Z", "family": "Visibility", "description": "For one hour, the corrected curves of the usual group make a bump that comes back: D-301-C (horizontal), D-302-B and PR_BG (vertical), D-301-A, D-300-A, D-304-B, D-304-C, D-302_A, and for a moment the reference PR-295; the recognition error of a few sensors rises during the episode. Same signature as the other episodes of view obstruction at the station; cause not established. Curves to ignore over the range.", "review": "2026-11-04"} {"id": "CLARIDEN-41", "start": "2026-10-31T18:45Z", "end": "2026-10-31T20:00Z", "family": "Visibility", "description": "For the duration of a few measurements, the corrected curves of D-301-C, P-301-B, P-299-A, D-302-B and PR_BG, D-303-B make a bump that comes back, and the reference PR-295, which is seen less well from 18:50, leaves its level; it is rejected at 19:50 (its curve is missing at that measurement), without the targets moving because of it. View obstruction of cause not established; points to ignore.", "review": "2026-11-04"} {"id": "CLARIDEN-42", "start": "2026-10-31T22:15Z", "end": "2026-11-01T00:00Z", "family": "Visibility", "description": "The reference PR-295 is seen poorly: its spot is weaker (23:00 thumbnail), it is rejected at times and, between two rejections, it is poorly measured; the compensation changes basis, and at 22:50 many targets jump together then return, without any movement of their raw positions. Until 23:50, the curves of D-301-C, P-301-B, D-302-B and PR_BG stay shifted, then briefly cross to the other side, with the recognition error of several targets rising. The camera housing temperature drops clearly at that hour. Cause of the obstruction not established (same signature as the other episodes). The jumps are not a movement: curves to ignore over the range.", "review": "2026-11-04"} {"id": "CLARIDEN-43", "start": "2026-10-31T23:10Z", "end": "2026-11-01T00:10Z", "family": "Thermal displacement", "description": "The camera housing temperature drops clearly on the evening of the 31st, and the camera scale deviates with it, then partly returns when the housing warms up; the strongest deviation comes when the curves return from the view obstruction of the same hour. The corrected curves do not follow this deviation: the compensation absorbs it. Camera movement by thermal effect, deduced from its pose against the housing temperature; normal, nothing to do.", "review": "2026-11-04"}